首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Influence of transport properties in electric field gradient focusing   总被引:1,自引:0,他引:1  
Miniaturized devices for electric field gradient focusing (EFGF) were developed that consist of a cylindrical separation channel surrounded by an acrylic-based polymer hydrogel. The ionic transport properties of the hydrogel enable the manipulation of the electric field inside the separation channel. A changing cross-section design was used in which the hydrogel is shaped such that an electric field gradient is established in the separation channel. One of the challenges with this type of EFGF device has been that experimental resolution between protein analytes is lower than theoretically predicted. In order to investigate this phenomenon, a mathematical transport model was developed using FEMLAB. Model results and experimental observations showed that the reduced performance was caused by concentration gradients formed in the EFGF channel, and that these concentration gradients were the result of an imbalance in cation transport between the open separation channel and the hydrogel. Removing acidic impurities from the monomers that form the hydrogel reduced this tendency and improved the resolution. These transport-induced concentration gradients can be used to establish electric field gradients that may be useful for sample pre-concentration. Both the results of simulation and experiments demonstrate how transport-induced concentration gradients lead to the establishment of electric field gradients.  相似文献   

2.
Electric field gradient focusing (EFGF) uses an electric field gradient and a hydrodynamic counter flow to simultaneously separate and focus charged analytes in a channel. Previously, most EFGF devices were designed to form a linear field gradient in the channel. However, the peak capacity obtained using a linear gradient is not much better than what can be obtained using conventional CE. Dynamic improvement of peak capacity in EFGF can be achieved by using a nonlinear gradient. Numerical simulation results indicate that the peak capacity in a 4-cm long channel can be increased from 20 to 150 when changing from a linear to convex bilinear gradient. To demonstrate the increased capacity experimentally, an EFGF device with convex bilinear gradient was fabricated from poly(ethylene glycol) (PEG)-functionalized acrylic copolymers. The desired gradient profile was confirmed by measuring the focusing positions of a standard protein for different counter flow rates at constant voltage. Dynamically controlled elution of analytes was demonstrated using a monolith-filled bilinear EFGF channel. By increasing the flow rate, stacked proteins that were ordered but not resolved after focusing in the steep gradient segment were moved into the shallow gradient segment, where the analyte peak resolution increased significantly. In this way, the nonlinear field gradient was used to realize a dynamic increase in the peak capacity of the EFGF method.  相似文献   

3.
Recently the use electric field gradient focusing (EFGF) to enhance focusing of proteins has been proposed and explored to provide significant improvement in separation resolution. The objective of EFGF is to focus proteins of specific electrophoretic mobilities at distinct stationary locations in a column or channel. This can be accomplished in a capillary by allowing the electric potential to vary in the streamwise direction. Because the electric field is varying, so also is the electrokinetic force exerted on the proteins and the electroosmotic velocity of the buffer solution. Due to the varying electric field, the Taylor diffusion characteristics will also vary along the column, causing a degradation of peak widths of some proteins, dependent on their equilibrium positions and local velocity distributions. The focus of this paper is an analysis that allows characterization of the local Taylor diffusion and resulting protein band peak width as a function of the local magnitude of the EOF relative to the average fluid velocity for both cylindrical and rectangular channels. In general the analysis shows that as the ratio of the local electroosmotic velocity to the average velocity deviates from unity, the effective diffusion increases significantly. The effectiveness of EFGF devices over a range of protein diffusivities, capillary diameters, flow velocities, and electric field gradient is discussed.  相似文献   

4.
Electric field gradient focusing (EFGF) uses a hydrodynamic flow and an electric field gradient to focus proteins in order of electrophoretic mobility. In this paper, we describe several bioanalytical applications using voltage-controlled hollow dialysis fiber-based EFGF with online UV detection. Using bovine serum albumin (BSA) as a model protein, a concentration factor as high as 15,000 and a concentration limit of detection as low as 30 pM were achieved. We also demonstrate the potential of using fiber-based EFGF for protein quantitative analysis. Simultaneous desalting and protein concentration were performed by mixing BSA with 2 M NaCl in a cell culture medium. Online concentration of ferritin and simultaneous removal of albumin from a sample matrix were performed using this EFGF system.  相似文献   

5.
Electric field gradient focusing (EFGF) is a technique used to simultaneously separate and concentrate biomacromolecules, such as proteins, based on the opposing forces of an electric field gradient and a hydrodynamic flow. Recently, we reported EFGF devices fabricated completely from copolymers functionalized with poly(ethylene glycol), which display excellent resistance to protein adsorption. However, the previous devices did not provide the predicted linear electric field gradient and stable current. To improve performance, Tris–HCl buffer that was previously doped in the hydrogel was replaced with a phosphate buffer containing a salt (i.e., potassium chloride, KCl) with high mobility ions. The new devices exhibited stable current, good reproducibility, and a linear electric field distribution in agreement with the shaped gradient region design due to improved ion transport in the hydrogel. The field gradient was calculated based on theory to be approximately 5.76 V/cm2 for R-phycoerythrin when the applied voltage was 500 V. The effect of EFGF separation channel dimensions was also investigated; a narrower focused band was achieved in a smaller diameter channel. The relationship between the bandwidth and channel diameter is consistent with theory. Three model proteins were resolved in an EFGF channel of this design. The improved device demonstrated 14,000-fold concentration of a protein sample (from 2 ng/mL to 27 μg/mL).  相似文献   

6.
Electromobility focusing (EMF) is a relatively new protein separation technique that utilizes an electric field gradient and a hydrodynamic flow. Proteins are focused in order of electrophoretic mobility at points where their electrophoretic migration velocities balance the hydrodynamic flow velocity. Steady state bands are formed along the separation channel when equilibrium is reached. Further separation and detection can be easily achieved by changing the electric field profile. In this paper. we describe an EMF system with on-line UV absorption detection in which the electric field gradient was formed using a dialysis hollow fiber. Protein focusing and preconcentration were performed with this system. Voltage-controlled separation was demonstrated using bovine serum albumin and myoglobin as model proteins. The limitations of the current method are discussed, and possible solutions are proposed.  相似文献   

7.
Electric fields are often used to transport fluids (by electroosmosis) and separate charged samples (by electrophoresis) in microfluidic devices. However, there exists inevitable Joule heating when electric currents are passing through electrolyte solutions. Joule heating not only increases the fluid temperature, but also produces temperature gradients in cross-stream and axial directions. These temperature effects make fluid properties non-uniform, and hence alter the applied electric potential field and the flow field. The mass species transport is also influenced. In this paper we develop an analytical model to study Joule heating effects on the transport of heat, electricity, momentum and mass species in capillary-based electrophoresis. Close-form formulae are derived for the temperature, applied electrical potential, velocity, and pressure fields at steady state, and the transient concentration field as well. Also available are the compact formulae for the electric current and the volume flow rate through the capillary. It is shown that, due to the thermal end effect, sharp temperature drops appear close to capillary ends, where sharp rises of electric field are required to meet the current continuity. In order to satisfy the mass continuity, pressure gradients have to be induced along the capillary. The resultant curved fluid velocity profile and the increase of molecular diffusion both contribute to the dispersion of samples. However, Joule heating effects enhance the sample transport velocity, reducing the analysis time in capillary electrophoretic separations.  相似文献   

8.
Electric field gradient focusing (EFGF) methods have received increased attention in recent years, with potential applications demonstrated by several research groups. In order to move EFGF from the research stage to routine use in application areas, a more detailed understanding of practical aspects of device performance is required. Useful theoretical models for EFGF are available but have not been verified through systematic checks under a variety of conditions. In this paper, we compare modeled and experimental results for an EFGF device with the goal of optimizing the time sequence of voltages applied to the device for maximum resolution of analytes with close electrophoretic mobilities. Measured peak profiles depend strongly on the sequence of voltages applied to the device. We investigate the characteristic behavior of the elution profile under various voltage programs. Rapid voltage drops lead to fast elution of closely spaced protein peaks with narrow widths, whereas a carefully designed voltage program can be used to increase the separation between analytes and achieve higher resolution. Simulated and experimental results demonstrate that the behavior of analyte diffusion at an electric field singularity associated with the transition from the EFGF device to elution capillary can be used to separate analyte peaks which may not be resolved within the EFGF device itself, thereby increasing the achievable resolution of the EFGF technique.  相似文献   

9.
The electric field and flow field gradients near an electrified converging channel are amenable to separating and focusing specific classes of electrokinetic material, but the detailed local electric field and flow dynamics in this region have not been thoroughly investigated. Finite elemental analysis was used to develop a model of a buffer reservoir connected to a smaller channel to simulate the electrophoretic and flow velocities (which correspond directly to the respective electric and flow fields) at a converging entrance. A detailed PTV (Particle Tracking Velocimetry) study using charged fluorescent microspheres was performed to assess the model validity both in the absence and presence of an applied electric field. The predicted flow velocity gradient from the model agreed with the PTV data when no electric field was present. Once the additional forces that act on the large particles required for tracing (dielectrophoresis) were included, the model accurately described the velocity of the charged particles in electric fields.  相似文献   

10.
Xuan X  Li D 《Electrophoresis》2005,26(1):166-175
It is widely accepted that Joule heating effects yield radial temperature gradients in capillary zone electrophoresis (CZE). The resultant parabolic profile of electrophoretic velocity of analyte molecules is believed to increase the band-broadening via Taylor-Aris dispersion. This typically insignificant contribution, however, cannot explain the decrease in separation efficiency at high electric fields. We show that the additional band-broadening due to axial temperature gradients may provide the answer. These axial temperature variations result from the change of heat transfer condition along the capillary, which is often present in CZE with thermostating. In this case, the electric field becomes nonuniform due to the temperature dependence of fluid conductivity, and hence the induced pressure gradient is brought about to meet the mass continuity. This modification of the electroosmotic flow pattern can cause significant band-broadening. An analytical model is developed to predict the band-broadening in CZE with axial temperature gradients in terms of the theoretical plate height. We find that the resultant thermal plate height can be very high and even comparable to that due to molecular diffusion. This thermal plate height is much higher than that due to radial temperature gradients alone. The analytical model explains successfully the phenomena observed in previous experiments.  相似文献   

11.
Bipolar electrode (BPE) focusing is a developing technique for enrichment and separation of charged analytes in a microfluidic channel. The technique employs a bipolar electrode that initiates faradaic processes that subsequently lead to formation of an ion depletion zone. The electric field gradient resulting from this depletion zone focuses ions on the basis of their individual electrophoretic mobilities. The nature of the gradient is of primary importance to the performance of the technique. Here, we report dynamic measurements of the electric field gradient showing that it is stable over time and that its axial position in the microchannel is directly correlated to the location of an enriched tracer band. The position of the gradient can be tuned with pressure-driven flow. We also show that a steeper electric field gradient decreases the breadth of the enriched tracer band and therefore enhances the enrichment process. The slope of the gradient can be tuned by altering the buffer concentration: higher concentrations result in a steeper gradient. Coating the channel with the neutral block co-polymer Pluronic also results in enhanced enrichment.  相似文献   

12.
A mathematical study of the effect of non-uniform electric fields on the width of DNA electrophoretic bands is presented. Using a simple model, we show that field gradients sharpen these bands during an experiment if the corresponding gradient of electrophoretic velocity is large enough. This is in agreement with experimental results indicating that narrower bands form when pulsed field electrophoresis is carried out in the presence of field gradients. Moreover, it is shown that there is in fact an optimal experimental duration that maximizes separation. Finally, gradients are also predicted to reduce the relative mobilities of the DNA fragments, which is a serious drawback of this technique.  相似文献   

13.
Huber DE  Santiago JG 《Electrophoresis》2007,28(14):2333-2344
Microfluidic temperature gradient focusing (TGF) uses an axial temperature gradient to induce a gradient in electrophoretic flux within a microchannel. When balanced with an opposing fluid flow, charged analytes simultaneously focus and separate according to their electrophoretic mobilities. We present a theoretical and experimental study of dispersion in TGF. We model the system using generalized dispersion analysis that yields a 1-D convection-diffusion equation that contains dispersion terms particular to TGF. We consider analytical solutions for the model under uniform temperature gradient conditions. Using a custom TGF experimental setup, we compare focusing measurements with the theoretical predictions. We find that the theory well represents the focusing behavior for flows within the Taylor-Aris dispersion regime.  相似文献   

14.
Two electric field gradient focusing (EFGF) systems, one based on a hollow dialysis fiber and the other based on a shaped ionically conductive polymer were serially integrated to trap and concentrate selected proteins while simultaneously desalting and removing other unwanted proteins from the sample. A series of experiments were performed to test the EFGF systems individually and after integration. Online concentration of amyloglucosidase indicated a concentration limit of detection of approximately 20 ng mL(-1) (200 pM) from a sample volume of 100 microL. Concentration of human alpha1-acid glycoprotein with simultaneous removal of human serum albumin was also demonstrated. Elimination of small buffer components while concentrating trypsin inhibitor, and selective concentration and separation of myoglobin from a mixture were performed using the integrated EFGF system.  相似文献   

15.
A microchannel device is presented which separates and focuses charged proteins based on electric field gradient focusing. Separation is achieved by setting a constant electroosmotic flow velocity against step changes in electrophoretic velocity. Where these two velocities are balanced for a given analyte, the analyte focuses at that point because it is driven to it from all points within the channel. We demonstrate the separation and focusing of a binary mixture of bovine serum albumin and phycoerythrin. The device is constructed of intersecting microchannels in poly(dimethylsiloxane)(PDMS) inlaid with hollow dialysis fibers. The device uses no exotic chemicals such as antibodies or synthetic ampholytes, but operates instead by purely physical means involving the independent manipulation of electrophoretic and electroosmotic velocities. One important difference between this apparatus and most other devices designed for field-gradient focusing is the injection of current at discrete intersections in the channel rather than continuously along the length of a membrane-bound separation channel.  相似文献   

16.
This paper reports rapid microfluidic electrokinetic concentration of deoxyribonucleic acid (DNA) with the Joule heating induced temperature gradient focusing (TGF) by using our proposed combined AC and DC electric field technique. A peak of 480-fold concentration enhancement of DNA sample is achieved within 40 s in a simple poly-dimethylsiloxane (PDMS) microfluidic channel of a sudden expansion in cross-section. Compared to a sole DC field, the introduction of an AC field can reduce DC field induced back-pressure and produce sufficient Joule heating effects, resulting in higher concentration enhancement. Within such microfluidic channel structure, negative charged DNA analytes can be concentrated at a location where the DNA electrophoretic motion is balanced with the bulk flow driven by DC electroosmosis under an appropriate temperature gradient field. A numerical model accounting for a combined AC and DC field and back-pressure driven flow effects is developed to describe the complex Joule heating induced TGF processes. The experimental observation of DNA concentration phenomena can be explained by the numerical model.  相似文献   

17.
Study of the deformation dynamics of cells and other sub‐micron vesicles, such as virus and neurotransmitter vesicles are necessary to understand their functional properties. This mechanical characterization can be done by submerging the vesicle in a fluid medium and deforming it with a controlled electric field, which is known as electrodeformation. Electrodeformation of biological and artificial lipid vesicles is directly influenced by the vesicle and surrounding media properties and geometric factors. The problem is compounded when the vesicle is naturally charged, which creates electrophoretic forcing on the vesicle membrane. We studied the electrodeformation and transport of charged vesicles immersed in a fluid media under the influence of a DC electric field. The electric field and fluid‐solid interactions are modeled using a hybrid immersed interface‐immersed boundary technique. Model results are verified with experimental observations for electric field driven translocation of a virus through a nanopore sensor. Our modeling results show interesting changes in deformation behavior with changing electrical properties of the vesicle and the surrounding media. Vesicle movement due to electrophoresis can also be characterized by the change in local conductivity, which can serve as a potential sensing mechanism for electrodeformation experiments in solid‐state nanopore setups.  相似文献   

18.
The electrophoretic motion of a long dielectric circular cylinder with a general angular distribution of its surface potential under a transversely imposed electric field in the vicinity of a large plane wall parallel to its axis is analyzed. The thickness of the electric double layers adjacent to the solid surfaces is assumed to be much smaller than the particle radius and the gap width between the surfaces, but the applied electric field can be either perpendicular or parallel to the plane wall. The presence of the confining wall causes three basic effects on the particle velocity: (1) the local electric field on the particle surface is enhanced or reduced by the wall; (2) the wall increases viscous retardation of the moving particle; (3) an electroosmotic flow of the suspending fluid may exist due to the interaction between the charged wall and the tangentially imposed electric field. Through the use of cylindrical bipolar coordinates, the Laplace and Stokes equations are solved analytically for the two-dimensional electric potential and velocity fields, respectively, in the fluid phase, and explicit formulas for the quasisteady electrophoretic and angular velocities of the cylindrical particle are obtained. To apply these formulas, one has only to calculate the multipole moments of the zeta potential distribution at the particle surface. It is found that the existence of a plane wall near a nonuniformly charged particle can cause its translation or rotation which does not occur in an unbounded fluid with the same applied electric field.  相似文献   

19.
Earlier studies of electric field assisted LC (EF-LC) have shown that the effect on charged analytes of the application of an electric field over a capillary LC column is relatively small. Charged analytes can only be affected by the electric field while present in the mobile phase, which makes the effective time for influence of the electric field t(0) independent of retention time. Because the charged analytes only can be affected for a short time the electric field strength ought to be high in order to increase the impact of the electric field on the separation. We have, however, found that only a relatively low electric field strength can be used in EF-LC when pressure is used as main driving force. The useful field strength was limited by a dramatic increase in the current. This increase in current was found to origin from an increased concentration of buffer ions that have an electrophoretic mobility towards the pumped flow.  相似文献   

20.
Burke JM  Ivory CF 《Electrophoresis》2008,29(5):1013-1025
Dynamic field gradient focusing (DFGF) is an equilibrium gradient method that utilizes an electric field gradient to simultaneously separate and concentrate charged analytes based on their individual electrophoretic mobilities. This work describes the use of a 2-D nonlinear, numerical simulation to examine the impact of voltage loss from the electrodes to the separation channel, termed voltage degradation, and distortions in the electric field on the performance of DFGF. One of the design parameters that has a large impact on the degree of voltage degradation is the placement of the electrodes in relation to the separation channel. The simulation shows that a distance of about 3 mm from the electrodes to the separation channel gives the electric field profile with least amount of voltage degradation. The simulation was also used to describe the elution of focused protein peaks. The simulation shows that elution under constant electric field gradient gives better performance than elution through shallowing of the electric field. Qualitative agreement between the numerical simulation and experimental results is shown. The simulation also illustrates that the presence of a defocusing region at the cathodic end of the separation channel causes peak dispersion during elution. The numerical model is then used to design a system that does not suffer from a defocusing region. Peaks eluted under this design experienced no band broadening in our simulations. Preliminary experimental results using the redesigned chamber are shown.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号