首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A capillary electrophoresis-mass spectrometry (CE-MS) method using sheath liquid electrospray ionization interfacing was studied and optimized for the analysis of intact basic proteins. To prevent protein adsorption, capillaries with a noncovalent positively charged coating were utilized. Capillaries were coated by subsequent rinsing with solutions of Polybrene, dextran sulfate and Polybrene. The coating proved to be fully compatible with MS detection, causing no background signals and ionization suppression. The composition of the sheath liquid and BGE was optimized using the model proteins α-chymotrypsinogen A, ribonuclease A, lysozyme and cytochrome c. A sheath liquid of isopropanol-water-acetic acid (75:25:0.1, v/v/v) at 2 μL min−1 resulted in optimal signal intensities for most proteins, but caused dissociation of the heme group of cytochrome c. Optimum protein responses were obtained with a BGE of 50 mM acetic acid (pH 3.0), which allowed a baseline separation of the test protein mixture. Several minor impurities present in the mixture could be detected and provisionally identified using accurate mass and a protein modification database. The selectivity of the CE-MS system was investigated by the analysis of acetylated lysozyme. Eight highly related species, identified as non-acetylated lysozyme and lysozyme acetylated in various degrees, could be distinguished. The CE-MS system showed good reproducibility yielding interday (three weeks period) RSDs for migration time and peak area within 2% and 10%, respectively. With the CE-MS system, determination coefficients (R2) for protein concentration and peak area were higher than 0.996, whereas detection limits were between 11 and 19 nM.  相似文献   

2.
CE coupled to MS has proven to be a powerful analytical tool for the characterization of intact proteins, as it combines the high separation efficiency of CE with the selectivity of MS. This review provides an overview of the development and application of CE-MS methods within the field of intact protein analysis as published between January 2007 and June 2010. Ongoing technological developments with respect to CE-MS interfacing, capillary coatings for CE-MS, coupling of CIEF with MS and chip-based CE-MS are treated. Furthermore, CE-MS of intact proteins involving ESI, MALDI and ICP ionization is outlined and overviews of the use of the various CE-MS methods are provided by tables. Representative examples illustrate the applicability of CE-MS for the characterization of proteins, including glycoproteins, biopharmaceuticals, protein-ligand complexes, biomarkers and dietary proteins. It is concluded that CE-MS is a valuable technique with high potential for intact protein analysis, providing useful information on protein identity and purity, including modifications and degradation products.  相似文献   

3.
The performance of a prototype porous tip sprayer for sheathless capillary electrophoresis-mass spectrometry (CE-MS) of intact proteins was studied. Capillaries with a porous tip were inserted in a stainless steel needle filled with static conductive liquid and installed in a conventional electrospray ionization (ESI) source. Using a BGE of 100 mM acetic acid (pH 3.1) and a positively charged capillary coating, a highly reproducible and efficient separation of four model proteins (insulin, carbonic anhydrase II, ribonuclease A and lysozyme) was obtained. The protein mass spectra were of good quality allowing reliable mass determination of the proteins and some of their impurities. Sheath-liquid CE-MS using the same porous tip capillary and an isopropanol-water-acetic acid sheath liquid showed slightly lower to similar analyte responses. However, as noise levels increased with sheath-liquid CE-MS, detection limits were improved by a factor 6.5-20 with sheathless CE-MS. The analyte response in sheathless CE-MS could be enhanced using a nanoESI source and adding 5% isopropanol to the BGE, leading to improved detection limits by 50-fold to 140-fold as compared to sheath liquid interfacing using the same capillary - equivalent to sub-nM detection limits for three out of four proteins. Clearly, the sheathless porous tip sprayer provides high sensitivity CE-MS of intact proteins.  相似文献   

4.
Developments in the fields of protein chemistry, proteomics and biotechnology have increased the demand for suitable analytical techniques for the analysis of intact proteins. In 1989, capillary electrophoresis (CE) was combined with mass spectrometry (MS) for the first time and its potential usefulness for the analysis of intact (i.e. non-digested) proteins was shown. This article provides an overview of the applications of CE-MS within the field of intact protein analysis. The principles of the applied CE modes and ionization techniques used for CE-MS of intact proteins are shortly described. It is shown that separations are predominantly carried out by capillary zone electrophoresis and capillary isoelectric focusing, whereas electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) are the most popular ionization techniques used for interfacing. The combination of CE with inductively coupled plasma (ICP) MS for the analysis of metalloproteins is also discussed. The various CE-MS combinations are systematically outlined and tables provide extensive overviews of the applications of each technique for intact protein analysis. Selected examples are given to illustrate the usefulness of the CE-MS techniques. Examples include protein isoform assignment, single cell analysis, metalloprotein characterization, proteomics and biomarker screening. Finally, chip-based electrophoresis combined with MS is shortly treated and some of its applications are described. It is concluded that CE-MS represents a powerful tool for the analysis of intact proteins yielding unique separations and information.  相似文献   

5.
In this work, a new physically adsorbed coating for capillary electrophoresis (CE) is presented. The coating is based on a N,N-dimethylacrylamide-ethylpyrrolidine methacrylate (DMA-EPyM) copolymer synthesized in our laboratory. The capillary coating is simple and easy to obtain as only requires flushing the capillary with a polymer aqueous solution for 2 min. It is shown that by using these coated capillaries the electrostatic adsorption of a group of basic proteins onto the capillary wall is significantly reduced allowing their analysis by CE. Moreover, the DMA-EPyM coating provides reproducible separations of the basic proteins with RSD values for migration times lower than 0.75% for the same day (n = 5) and lower than 3.90% for three different days (n = 15). Interestingly, the electrical charge of the coated capillary wall can be modulated by varying the pH of the running buffer which makes possible the analysis of basic and acidic proteins in the same capillary. The usefulness of this coating is further demonstrated via the reproducible separation of whey (i.e. acidic) proteins from raw milk. The coating protocol should be compatible with both CE in microchips and CE-MS of different types of proteins.  相似文献   

6.
To simplify capillary electrophoresis-mass spectrometry (CE-MS) operation, a background electrolyte (BGE) containing a polymer additive is introduced that allows the analysis of peptides and protein mixtures in underivatized fused-silica capillaries without any pretreatment, thereby increasing throughput. The most important characteristic of these polymer additives is that they do not significantly suppress the signals of the proteins and peptides under electrospray ionization, thereby allowing them to be used as an additive to common BGEs that are used for CE-MS analysis of peptide and protein mixtures. In addition, because the fused-silica capillary inner wall is continuously coated with the polymer additive, migration irreproducibility, due to the degradation of the capillary inner wall coating, under CE-MS is minimized. High sensitivity of detection, migration reproducibility, and ease of fabrication allow CE-MS analyses that require long analysis time, such as (CE-MS/MS)n, to be performed with ease. The utility of this background electrolyte has been demonstrated for the analysis of complex protein digests and intact proteins.  相似文献   

7.
Mass spectrometry (MS) has become a key tool for the characterization of biologically relevant molecules in the last decade. Due to the complexity of most biological samples an upstream separation is essential. Capillary electrophoresis (CE) has gained much interest due to its high separation efficiency, speed, and often complementary selectivity to liquid chromatography. We describe the state-of-the-art of on-line CE-MS for the analysis of molecules of biological origin. The characterization of peptides, including the study of post-translational modifications, intact proteins, oligonucleotides, and related interaction studies are reviewed. Relevant publications are summarized in tables, including some important method parameters. Key applications are discussed with respect to the advantages and limitations of CE-MS. Coupling interfaces, preconcentration techniques, capillary coatings, and the different CE techniques, e.g., capillary zone electrophoresis, capillary isoelectric focusing, capillary gel electrophoresis, etc. are briefly discussed against the background of their bioanalytical applications.  相似文献   

8.
A new physically adsorbed capillary coating for capillary electrophoresis-mass spectrometry (CE-MS) of basic proteins is presented, which is easily obtained by flushing the capillary with a polymer aqueous solution for two min. This coating significantly reduces the electrostatic adsorption of a group of basic proteins (i.e., cytochrome c, lysozyme, and ribonuclease A) onto the capillary wall allowing their analysis by CE-MS. The coating protocol is compatible with electrospray inonization (ESI)-MS via the reproducible separation of the standard basic proteins (%RSD values (n = 5) < 1% for analysis time reproducibility and < 5% for peak heights, measured from the total ion electropherograms (TIEs) within the same day). The LODs determined using cytochrome c with total ion current and extracted ion current defection were 24.5 and 2.9 fmol, respectively. Using this new coating lysozymes from chicken and turkey egg white could be easily distinguished by CE-MS, demonstrating the usefulness of this method to differentiate animal species. Even after sterilization at 120 degrees C for 30 min, lysozyme could be detected, as well as in wines at concentrations much lower than the limit marked by the EC Commission Regulation. Adulteration of minced meat with 5% of egg-white could also be analysed by our CE-MS protocol.  相似文献   

9.
Erny GL  Marina ML  Cifuentes A 《Electrophoresis》2007,28(22):4192-4201
In this work, an original CE-MS method has been developed to analyze the complex zein protein fractions from maize. A thorough optimization of: (i) zein protein extraction, (ii) CE separation, and (iii) electrospray-MS (ESI-MS) detection is carried out in order to obtain highly informative CE-MS profiles of this fraction. The developed CE-MS method provides good separation of multiple zein proteins based on their electrophoretic mobilities as well as adequate characterization of these proteins based on their M(r). Zein proteins with small M(r) differences (below 100 Da) were easily separated and successfully analyzed by CE-MS. Thus, apart of the so-called 15-kDa-beta-zein and 16-kDa-gamma-zein, which are demonstrated to be formed by a heterogeneous group of proteins, numerous alpha-zeins belonging to the 19- and 22-kDa fraction were also identified for the first time in this work. The usefulness of this CE-MS method was corroborated by comparing the zein-protein fingerprints of various maize lines including transgenic and their corresponding nontransgenic isogenic lines cultivated under the same conditions.  相似文献   

10.
Over the last two decades, coupled capillary electrophoresis (CE)–mass spectrometry (MS) has developed into a generally accepted technique with a wide applicability. A growing number of CE-MS applications make use of capillaries where the internal wall is modified with surface coating agents. In CE-MS, capillary coatings are used to prevent analyte adsorption and to provide appropriate conditions for CE-MS interfacing. This paper gives an overview of the various capillary coating strategies used in CE-MS. The main attention is devoted to the way coatings can contribute to a proper CE-MS operation. The foremost capillary coating methods are discussed with emphasis on their compatibility with MS detection. The role of capillary coatings in the control of the electroosmotic flow and the consequences for CE-MS coupling are treated. Subsequently, an overview of reported applications of CE-MS employing different coating principles is presented. Selected examples are given to illustrate the usefulness of the coatings and the overall applicability of the CE-MS systems. It is concluded that capillary coatings can enhance the performance and stability of CE-MS systems, yielding a highly valuable and reproducible analytical tool.  相似文献   

11.
梁玉  张丽华  张玉奎 《色谱》2020,38(10):1117-1124
蛋白质组学研究在生物学、精准医学等方面发挥着重要的作用。然而研究面临的巨大挑战来自生物样品的复杂性,因此在质谱(MS)鉴定技术不断革新的同时,发展分离技术以降低样品复杂度尤为重要。毛细管电泳(CE)技术具有上样体积小、分离效率高、分离速度快等优势,其与质谱的联用在蛋白质组学研究中越来越受到关注。低流速鞘流液和无鞘流液接口的发展及商品化推动了CE-MS技术的发展。目前毛细管区带电泳(CZE)、毛细管等电聚焦(CIEF)、毛细管电色谱(CEC)等分离模式已与质谱联用,其中CZE-MS应用最广泛。目前被广泛采用的蛋白质组学研究策略主要是基于酶解肽段分离鉴定的"自下而上(bottom-up)"策略。首先,CE-MS技术对酶解肽段的检测灵敏度高达1 zmol,已成功应用于单细胞蛋白质组学;其次,毛细管电泳技术与反相液相色谱互补,为疏水性质相近的肽段(尤其是翻译后修饰肽段)的分离鉴定提供了新的途径。基于整体蛋白质分离鉴定的自上而下"top-down"策略可以直接获得更精准、更完整的蛋白质信息。CE技术在蛋白质大分子的分离方面具有分离效率高、回收率高的优势,其与质谱的联用提高了整体蛋白质的鉴定灵敏度和覆盖度。非变性质谱(native MS)是一种在近生理条件下从完整蛋白质复合物水平上进行分析的质谱技术。CE与非变性质谱联用已被尝试用于蛋白质复合体的分离鉴定。该文引用了与CE-MS和蛋白质组学应用相关的93篇文献,综述了以上介绍的CE-MS的研究进展以及在蛋白质组学分析中的应用优势,并总结和展望了其应用前景。  相似文献   

12.
A simple coating procedure for generation of a high and pH-independent electroosmotic flow in capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) is described. The bilayer coating was formed by noncovalent adsorption of the ionic polymers Polybrene and poly(vinylsulfonate) (PVS). A stable dynamic coating was formed when PVS was added to the background electrolyte. Thus, when the PVS concentration in the background electrolyte was optimized for CZE (0.01%), the EOF differed less than 0.3% after 54 runs. The electroosmotic mobility in the coated capillaries was (4.9+/-0.1) x 10(-4) cm2V(-1)s(-1) in a pH-range of 2-10 (ionic strength = 30 mM). When alkaline compounds were used as test substances intracapillary and intercapillary migration time variations (n = 6) were less than 1% relative standard deviation (RSD) and 2% RSD, respectively in the entire pH range. The coating was fairly stable in the presence of sodium dodecyl sulfate, and this made it possible to perform fast MEKC separations at low pH. When neutral compounds were used as test substances, the intracapillary migration time variations (n = 6) were less than 2% RSD in a pH range of 2-9. In addition to fast CZE and MEKC separations at low pH, analysis of the alkaline compounds by CE-MS was also possible.  相似文献   

13.
Protein glycosylation can impact the efficacy, safety, and pharmacokinetics of therapeutic proteins. Achieving uniform and consistent protein glycosylation is an important requirement for product quality control at all stages of therapeutic protein drug discovery and development. The development of a new microfluidic CE device compatible with MS offers a fast and sensitive orthogonal mode of high-resolution separation with MS characterization. Here, we describe a fast and robust chip-based CE-MS method for intact glycosylation fingerprinting of a therapeutic fusion protein with complex sialylated N and O-linked glycoforms. The method effectively separates multiple sialylated glycoforms and offers a rapid detection of changes in glycosylation profile in 6 min.  相似文献   

14.
In this work, the determination of a group of triazolopyrimidine sulfoanilide herbicides (cloransulam-methyl, metosulam, flumetsulam, florasulam, and diclosulam) in soy milk by capillary electrophoresis-mass spectrometry (CE-MS) is presented. The main electrospray interface (ESI) parameters (nebulizer pressure, dry gas flow rate, dry gas temperature, and composition of the sheath liquid) are optimized using a central composite design. To increase the sensitivity of the CE-MS method, an off-line sample preconcentration procedure based on solid-phase extraction (SPE) is combined with an on-line stacking procedure (i.e. normal stacking mode, NSM). Samples could be injected for up to 100 s, providing limits of detection (LODs) down to 74 microg/L, i.e., at the low ppb level, with relative standard deviation values (RSD,%) between 3.8% and 6.4% for peak areas on the same day, and between 6.5% and 8.1% on three different days. The usefulness of the optimized SPE-NSM-CE-MS procedure is demonstrated through the sensitive quantification of the selected pesticides in soy milk samples.  相似文献   

15.
Moini M  Huang H 《Electrophoresis》2004,25(13):1981-1987
We introduce capillary electrophoresis-mass spectrometry (CE-MS) as an efficient means for the on-line separation and identification of protein mixtures. It was found that while CE/electrospray ionization (ESI)-MS analysis of whole-cell lysate was too complicated for the one-dimensional CE-MS analysis, the technique was useful for the analysis of protein mixtures of moderate complexity (approximately 50 intact proteins). CE/ESI-MS was applied to the subcellular proteomics of ribosomal Escherichia coli. 55 out of the 56 ribosomal proteins were detected with ease by using only approximately 3.4 ng of ribosomal proteins. In addition, it was found that the mass accuracy of the conventional MS (such as quadrupole ion traps) was good enough to identify many post-translational modifications of the intact proteins by simply comparing their measured average molecular weight with the average molecular weight predicted from gene banks.  相似文献   

16.
In this work, two different CE-MS instruments, namely, CE-ESI-IT-MS and CE-ESI-TOF-MS, applied to analyse intact proteins from complex samples are investigated. The aim of this work was to compare both instruments in terms of LOD, number of proteins detected, and precision and repeatability in the determination of the protein relative molecular mass. Results show that although CE-ESI-IT-MS provides cleaner MS spectra of intact proteins, CE-ESI-TOF-MS allows the identification of a higher number of proteins from complex matrices in an easier way. Performance in terms of peak area reproducibility, LOD and precision in the determination of the molecular mass were similar for both instruments. The usefulness of the optimised CE-ESI-IT-MS and CE-ESI-TOF-MS conditions was demonstrated by studying the zein-proteins composition of three natural maize lines and their corresponding transgenic lines, showing no significant differences.  相似文献   

17.
A stir bar coated with β-cyclodextrin-bonded-silica (CDS) as novel sorbent has been developed and used to analyze seven phenolic compounds in aqueous samples, followed by thermal desorption and gas chromatography-mass spectrometric detection. Significant parameters affecting sorption process such as the time and temperature of sorption and desorption, ionic strength, pH and stirring rate have been optimized and discussed. The coating has a high thermal stability up to 300°C and long application lifetime (80 times). The porous structure of CDS coating provides high surface area and allows high extraction efficiency. Under the selected conditions, linearity range of 0.1-400 μg/L, limit of quantifications of 0.08-3.3 μg/L and method detection limits of 0.02-1.00 μg/L have been obtained. A satisfactory repeatability (RSD ≤ 6.5, n = 7) with good linearity (0.9975 ≤ r(2) ≤ 0.9996) of results illustrated a good performance of the present method. The recovery of different natural water samples was higher than 81.5%.  相似文献   

18.
The sol-gel method is a widely used technique for the synthesis of various functional coating films. Alkoxysilanes such as (3-methacryloxypropyl)trimethoxysilane (MEMO) are largely used as precursors for inorganic-organic hybrid sol-gel materials. Indeed, these compounds can form complex network, through hydrolysis and condensation reactions. The latter have to be perfectly controlled to obtain the required properties. In such a context, we have studied the potentialities of capillary electrophoresis-ion-trap mass spectrometry (CE-MS) coupling to resolve both separation and characterization of the synthesized compounds as a function of the hydrolysis time. The study of acid hydrolysis of MEMO was carried out as an example. After optimization of the running electrolyte in capillary zone electrophoresis (CZE) with UV detection, we characterized the synthesized compounds in CE-MS by using positive detection mode. The obtained resolution in CZE-UV was not entirely satisfactory because of the very closed charge/mass ratio of formed solute but also because of the interaction between the solutes and the capillary walls. Nevertheless, several oligomers were characterized in CE-MS. The absence of detection with regard to oligomers that possess higher molecular masses than octamer is discussed in this work.  相似文献   

19.
Fused-silica capillaries chemically derivatized with silane/poly(vinylpyrrolidone) (PVP) or dynamically modified with plexiglas [poly(methyl methacrylate)] were prepared and evaluated with regard to column stability and separation performance for capillary isoelectric focusing of standard proteins. The PVP coating showed the better stability and was good for at least 100 runs while the plexiglas coating started to deteriorate after about 30 runs. The time spent for the plexiglas coating is about 40 minutes while the PVP coating requires two days. The migration time reproducibility was better with the PVP capillary (RSD 0.7-1.6%, n = 5) compared to the plexiglas-coated column (RSD 1.2-2.9%, n = 5) while peak area and height varied over a similar interval (RSD 2-28.1% area; 0.9-22.7% height, n = 5). The two most consistent proteins in this evaluation, viz. myoglobin A and carbonic anhydrase II, showed linear dynamic ranges between 5-150 and 5-50 microg/mL, and limits of detections at 2 and 1 microg/mL, respectively, employing UV detection at 280 nm.  相似文献   

20.
A new type of monolithic trapping columns with high mechanical strength was prepared by thin-layer sol–gel coating method and applied to trapping intact proteins for on-line capillary liquid chromatography. Monolithic trapping columns were fabricated by entrapping C8 reversed-phase particles into the capillary columns through a sol–gel network, which was formed by hydrolysis and polycondensation of methyltriethoxysilane. Hundreds times of trapping/untrapping for intact proteins were carried out. The trapping columns showed long-term stability up to 300 bar. Recovery, loading capacity and reproducibility of trapping columns were evaluated using four proteins. The recovery of four protein mixtures for the C8 monolithic trapping columns was 99.3% on average. The loading capacity of 5 mm × 320 μm i.d. C8 trapping columns for the protein mixtures was 30 μg. Day-to-day relative standard deviation (RSD) values for recoveries of protein mixtures on the same C8 trapping column ranged from 2.34 to 5.87%, column-to-column RSD values were from 3.01 to 6.81%. The C8 trapping columns were used to trap normal mouse liver intact proteins in a capillary liquid chromatography system. Results demonstrated high efficiency of the monolithic trapping columns for trapping intact proteins for proteomic analysis in on-line capillary liquid chromatography system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号