首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到11条相似文献,搜索用时 15 毫秒
1.
2.
Di Chen  Junru Wu 《Ultrasonics》2010,50(8):744-749
A liposome with a diameter ranging from 150 to 200 nm has been considered to be one of the optimal vehicles for targeted drug delivery in vivo since it is able to encapsulate drug and also circulate in the blood stream stably. Its small size, however, makes controlled release of its encapsulated content difficult. A feasibility study for applications of high intensity focused ultrasound (HIFU) of the mega-hertz frequency to induce controlled release of its content was carried out. This study, using the dynamic light scattering and transmission electron microscopic observation, demonstrated 21.2% of encapsulated fluorescent materials (FITC) could be released from liposomes with an average diameter of 210 nm when exposed to continuous (cw) ultrasound at 1.1 MHz (ISPTA = 900 W/cm2) for 10 s and the percentage release efficiency can reach to 70% after 60 s irradiation. This result also reveals that rupture of relatively large liposomes (>100 nm) and generation of pore-like defects in the membrane of small liposomes (<100 nm) due to HIFU excitation might be the main causes of the release; the inertial cavitation took place during the irradiation. The controlled drug release from liposomes by HIFU may be proven to be a potential useful modality for clinical applications.  相似文献   

3.
高强聚焦超声(HIFU)加热活体组织中的温度分布   总被引:2,自引:1,他引:1       下载免费PDF全文
钱祖文 《应用声学》2010,29(4):269-272
在高强聚焦超声(HIFU)加热的情况下,利用多针射频(RF)测温装置测量活体组织内的温度分布,结果表明,温度梯度依赖于局部温度,温度越高,梯度越大。此外,本文还研究了血流对温度梯度的影响,结果似乎证实了理论预测,即血流(或血液灌注)减缓了温度(梯度)的变化。  相似文献   

4.
在高强度聚焦的超声场检测中,与一般的传感器相比,光纤在这一领域有着其特有的优势。本文从光纤的角度详细分析了各种可能的方法,比如端面法,声光衍射法,光纤光栅法等。  相似文献   

5.
高强度聚焦超声(High Intensity Focused Ultrasound,HIFU)治疗肿瘤时,为了保证治疗的安全性和有效性,需要对组织温度分布进行实时监测.磁共振成像(Magnetic Resonance Imaging,MRI)具有对温度敏感的成像参数,可以无创检测组织温度.本文结合组织相变对测温的影响,探讨了磁共振测温(Magnetic Resonance Thermometry,MRT)技术能否用于实时监控HIFU治疗.利用两态快速交换模型,提出在组织凝固性坏死的相变前后,MRI的纵向弛豫时间(T1)参数与组织温度之间具有不同关系.并通过实验验证了上述假设.相对于传统的磁共振测温方法模型,本文考虑了HIFU治疗过程中组织相变对检测温度的影响,对利用磁共振测温引导HIFU治疗具有重要的参考价值.  相似文献   

6.
Raman spectroscopy is a powerful optical technique capable of providing the structural information at the molecular level. Thus, the technique can be used to detect biochemical changes associated with carcinogenesis and identify the biomolecules involved in cancer. We studied the Raman spectral characteristics of normal, carcinoma in situ, and invasive squamous cell carcinoma (SCC) tissues of tongue, and identified the spectral features that can discriminate these three tissue types. We found that the intensities of Raman bands assignable to tryptophan increase while those attributable to protein keratin decrease when tissue changes from normal to invasive SCC. The variation observed in the intensity of many discriminating peaks including those of tryptophan and keratin as tissue changes from normal to carcinoma in situ and then to invasive SCC suggests that Raman spectroscopy can be used to monitor progression of the disease. We have also analyzed the data with multivariate statistical methods such as principal component analysis and discriminant function analysis. These chemometric methods clearly separate the whole data into three distinct groups consistent with results of pathology. We were able to detect with 91% success rate the normal and carcinoma in situ tissues and with 89% accuracy the invasive SCC tissues of the tongue. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.

Purpose

To investigate the correlation between perfusion-related parameters obtained with intravoxel incoherent motion (IVIM) and classical perfusion parameters obtained with dynamic contrast-enhanced (DCE) magnetic resonance imaging in patients with head and neck squamous cell carcinoma (HNSCC), and to compare direct and asymptotic fitting, the pixel-by-pixel approach, and a region of interest (ROI)-based approach respectively for IVIM parameter calculation.

Materials and methods

Seventeen patients with HNSCC were included in this retrospective study. All magnetic resonance (MR) scanning was performed using a 3 T MR unit. Acquisition of IVIM was performed using single-shot spin-echo echo-planar imaging with three orthogonal gradients with 12 b-values (0, 10, 20, 30, 50, 80, 100, 200, 400, 800, 1000, and 2000). Perfusion-related parameters of perfusion fraction ‘f’ and the pseudo-diffusion coefficient ‘D*’ were calculated from IVIM data by using least square fitting with the two fitting methods of direct and asymptotic fitting, respectively. DCE perfusion was performed in a total of 64 dynamic phases with a 3.2-s phase interval. The two-compartment exchange model was used for the quantification of tumor blood volume (TBV) and tumor blood flow (TBF). Each tumor was delineated with a polygonal ROI for the calculation of f, f ? D* performed using both the pixel-by-pixel approach and the ROI-based approach. In the pixel-by-pixel approach, after fitting each pixel to obtain f, f ? D* maps, the mean value in the delineated ROI on these maps was calculated. In the ROI-based approach, the mean value of signal intensity was calculated within the ROI for each b-value in IVIM images, and then fitting was performed using these values. Correlations between f in a total of four combinations (direct or asymptotic fitting and pixel-by-pixel or ROI-based approach) and TBV were respectively analyzed using Pearson's correlation coefficients. Correlations between f ? D* and TBF were also similarly analyzed.

Results

In all combinations of f and TBV, f ? D* and TBF, there was a significant correlation. In the comparison of f and TBV, a moderate correlation was observed only between f obtained by direct fitting with the pixel-by-pixel approach, whereas a good correlation was observed in the comparisons using the other three combinations. In the comparison of f ? D* and TBF, a good correlation was observed only with f ? D* obtained by asymptotic fitting with the ROI-based approach. In contrast, moderate correlations were observed in the comparisons using the other three combinations.

Conclusion

IVIM was found to be feasible for the analysis of perfusion-related parameters in patients with HNSCC. Especially, the combination of asymptotic fitting with the ROI-based approach was better correlated with DCE perfusion.  相似文献   

8.
Early diagnosis of oral carcinomas is essential for successful treatment. The purpose of the present study is to apply near‐infrared Raman spectroscopy to detect oral squamous cell carcinoma (SCC) and leukoplakia (OLK), in order to establish the diagnostic model of the Raman spectra of oral diseases. We collected Raman spectra of normal, OLK and SCC by near‐infrared Fourier transform Raman spectroscopy. The biochemical variations between different lesions were analyzed by the characteristic bands in the subtracted mean spectra. Gaussian radial basis function support vector machines (SVM) were used to classify spectra and establish the diagnostic models. Major differences were observed in the range between 800 and 1800 cm−1. Compared with normal mucosa, high contents of protein, DNA and lipid in SCC and OLK were observed, but the difference between OLK and normal tissue was not as much as that between normal and SCC. SVM displayed a powerful ability in the classifying of normal and SCC, and the specificity, sensitivity and accuracy were 100, 97.56 and 98.75%, respectively. In discriminating between the OLK and normal groups, the three parameters were 85, 68 and 72.5%. The algorithm showed good ability in grouping and modeling of OLK and SCC, and the three parameters were 95, 97.43 and 96.25%. Combined with SVM, near‐infrared Raman spectroscopy can detect biochemical variations in oral normal mucosa, OLK and SCC, and establish diagnostic models accurately. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Higher perfusion of uterine fibroids at baseline is recognized as cause for poor efficacy of MR-guided high intensity focused ultrasound (HIFU) ablation, and higher acoustic power has been suggested for the treatment of high-perfused areas inside uterine fibroids. However, considering the heterogeneously vascular distribution inside the uterine fibroids especially with hyper vascularity, it is not easy to choose the correct therapy acoustic power for every part inside fibroids. In our study, we presented two cases of fibroids with hyper vascularity, to show the differences between them with different outcomes. Selecting higher therapy acoustic powers to ablate high-perfused areas efficiently inside fibroids might help achieving good ablation results. Volume transfer constant (Ktrans) maps from dynamic contrast-enhanced (DCE) imaging at baseline helps visualizing perfusion state inside the fibroids and locating areas with higher-perfusion. In addition, with the help of Ktrans maps, appropriate therapy acoustic power could be selected by the result of initial test and therapy sonications at different areas with significantly different perfusion state inside fibroids.  相似文献   

10.
We have employed low energy electron diffraction (LEED) and X-ray photoelectron spectroscopy to follow the epitaxial growth of thin films of TiO2 on W(1 0 0). The films were grown both by metal vapour deposition of titanium onto the substrate in UHV with subsequent annealing in a low partial pressure of oxygen, and by metal vapour deposition in a low partial pressure of oxygen. LEED patterns showed the characteristic patterns of (1 1 0) oriented rutile. A systematic spot splitting was observed and attributed to a stepped surface. The calculated step height was found to be in good agreement with that expected for rutile TiO2(1 1 0), 3.3 Å. Titanium core level shifts were used to identify oxidation states as a function of film thickness allowing the interpretation in terms of a slightly sub-stoichiometric interface layer in contact with the substrate. In combination with the LEED patterns, the film structure is therefore determined to be (1 1 0) oriented rutile with a comparable level of stoichiometry to UHV prepared bulk crystals. The ordered step structure indicates considerable structural complexity of the surface.  相似文献   

11.
The simultaneous Ag loaded and N-doped TiO2 hollow nanorod arrays with various contents of silver (Ag/N-THNAs) were successfully synthesized on glass substrates by one-pot liquid phase deposition (LPD) method using ZnO nanorod arrays as template. The catalysts were characterized by Raman spectrum, field-emission scanning electron microscopy (FESEM), high-resolution transmission electron microscope (HRTEM), ultraviolet-vis (UV-vis) absorption spectrum and X-ray photoelectron spectroscopy (XPS). The results suggest that AgNO3 additive in the precursor solutions not only can promote the anatase-to-rutile phase transition, but also influence the amount of N doping in the samples. The photocatalytic activity of all the samples was evaluated by photodegradation of methylene blue (MB) in aqueous solution. The sample exhibited the highest photocatalytic activity under UV light illumination when the AgNO3 concentration in the precursor solution was 0.03 M, due to Ag nanoparticles acting as electron sinks; When the AgNO3 concentration was 0.07 M, the sample performed best under visible light illumination, attributed to the synergetic effects of Ag loading, N doping, and the multiphase structure (anatase/rutile).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号