首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method was developed for the simultaneous determination of selenomethionine (SeMet) and selenocysteine (SeCys) in meat (chicken and lamb muscles) and different offal tissues (heart, liver, kidney). The analytical procedure was based on the protein extraction with urea under reducing conditions (dithiothreitol), derivatization of SeCys and SeMet by carbamidomethylation with iodoacetamide (IAM) followed by quantitative proteolysis. The mixture of the derivatized Se-amino acids was purified by size-exclusion liquid chromatography (LC) and analysed by ion-paring reversed-phase HPLC–inductively coupled plasma mass spectroscopy (ICP MS). The quantification of SeCys and SeMet was carried out by the method of standard additions. 77SeMet was used to control the SeMet derivatization efficiency and recovery. The method was validated by the determination of the Se mass balance. The Se-amino acids accounted for 91 ± 8% of the total selenium (mean of 95 samples of seven tissues analysed over a period of 18 months). The method was applied to the discrimination of the contribution of selenoproteins (containing SeCys) and other Se-containing proteins (containing SeMet) in tissues of animals during supplementation studies (dose–effect and tolerance).  相似文献   

2.
Selenium (Se) is an essential trace element, which represents an integral part of glutathione peroxidase and other selenoproteins involved in the protection of cells against oxidative damage. Selenomethionine (SeMet), selenocysteine (SeCys), and methylselenocysteine (MeSeCys) are the forms of Se that occur in living systems. Se-containing compounds have been found to reduce carcinogenesis of animal models, and dietary supplemental Se might decrease cancer risk. Se is mainly taken up by plant roots in the form of selenate via high-affinity sulfate transporters. Consequently, owing to the chemical similarity between Se and sulfur (S), the availability of S plays a key role in Se accumulation owing to competition effects in absorption, translocation, and assimilation. Moreover, naturally occurring S-containing compounds have proven to exhibit anticancer potential, in addition to other bioactivities. Therefore, it is important to understand the interaction between Se and S, which depends on Se/S ratio in the plant or/and in the growth medium. Brassicaceae (also known as cabbage or mustard family) is an important family of flowering plants that are grown worldwide and have a vital role in agriculture and populations’ health. In this review we discuss the distribution and further interactions between S and Se in Brassicaceae and provide several examples of Se or Se/S biofortifications’ experiments in brassica vegetables that induced the chemopreventive effects of these crops by enhancing the production of Se- or/and S-containing natural compounds. Extensive further research is required to understand Se/S uptake, translocation, and assimilation and to investigate their potential role in producing anticancer drugs.  相似文献   

3.
Speciation analysis of selenomethylcysteine (SeMeCys), selenomethionine (SeMet) and selenocystine (SeCys) has been performed using a direct amino acid analysis method with high-performance anion-exchange chromatography (HPAEC) coupled with integrated pulsed amperometric detection (IPAD). Three selenoamino acids could be baseline-separated from 19 amino acids using gradient elution conditions for amino acids and determined under new six-potential waveform. Detection limits for SeMeCys, SeMet and SeCys were 0.25, 1 and 20 microg/L (25 microL injection, 10 times of the baseline noise), respectively. The relative standard deviations (RSDs) of 200 microg/L SeMeCys, SeMet and SeCys were 3.1, 4.1 and 2.8%, respectively (n=9, 25 microL injection). The proposed method has been applied for determination of selenoamino acids in extracts of garlic and selenious yeast granule samples. No selenoamino acids were found in garlic. Both SeMet and SeCys were detected in selenious yeast tablet with the content of 45 and 129 microg Se/g, respectively. Selenoamino acids standards were spiked in garlic and yeast granule samples and the recovery ranged from 90 to 106%.  相似文献   

4.
A procedure was developed for the quantitative recovery of selenomethionine (SeMet) and selenocysteine (SeCys) from whole milk. It was based on the protein unfolding, carbamidomethylation of the aminoacid residues using iodoacetamide and proteolysis using Protease XIV. The selenoaminoacids were specifically determined by ion-paring reversed phase HPLC-ICP MS after their isolation from the post-reaction mixture by size-exclusion LC. Se(IV) present in the sample was derivatized as well and was determined along with the selenoaminoacids. The origin and identity of species were identified by the co-elution with the Se(IV), isotopically labelled selenomethionine, and with the synthetic standard of carbamidomethylated selenocysteine. The method development for SeCys was assisted by using glutathione peroxidise as the SeCys standard. SeMet, SeCys and Se(IV) were quantified by the method of standard additions. The mass balance provided a measure of the method validation. The method was applied to monitoring selenium speciation during supplementation of cows (dose-effect study) with Se-rich yeast containing feed and during milk processing.  相似文献   

5.
A method for the simultaneous determination of selenomethionine (SeMet), selenocysteine (SeCys), and selenite [Se(IV)] in chicken eggs was developed. A sample preparation protocol including defatting, protein denaturation, and carbamidomethylation was optimized in order to achieve complete protein digestion and to avoid SeCys losses. Quantification was carried out by reversed-phase HPLC–inductively coupled plasma mass spectrometry (ICP MS) after quantitative isolation of the selenium-containing fraction by size-exclusion liquid chromatography. The detection limits were 0.06, 0.003, and 0.01 μg g−1 (dry weight) for SeCys, Se(IV) and SeMet, respectively, and the precision was 5–10%. The end products of carbamidomethylation of the different selenium species were identified for the first time by electrospray QTOF MS after custom-designed 2D HPLC purification. Differences in selenium speciation in egg yolk and white were highlighted, the yolk containing more SeCys and the white more SeMet. An insight into selenium bioaccessibility in eggs was obtained by digestion with simulated gastric and gastrointestinal juices and size-exclusion HPLC-ICP MS.  相似文献   

6.
Speciation of selenocysteine (SeCys), selenomethionine (SeMet), selenoethionine (SeET), selenite (Se(IV)) and selenate (Se(VI)) has been accomplished using high-performance liquid chromatography, with the aid of an anion exchange column and a reversed-phase column, both connected through a six-port switching valve. On-line microwave-assisted digestion and hydride generation steps were performed prior to the atomic fluorescence detection. The elution of the seleno amino acids was accomplished in the reversed-phased column using water as mobile phase. Selenite and selenate were separated in the anion exchange column, using gradient elution with an acetate buffer. The separation of the five selenium compounds took place in 15 min. The detection limits obtained ranged between 0.6 and 0.9 microg l(-1). Values of r>0.998 were obtained for linear fit graphs. A commercial available urine sample was analyzed, in which SeCys and Se(IV) were quantified.  相似文献   

7.
A novel, fast, and cheap nonchromatographic method for direct speciation of dissolved inorganic and organic selenium species in environmental and biological samples was developed by flow injection (FI) dual-column preconcentration/separation on-line coupled with ICP-MS determination. In the developed technique, the first column packed with nanometer-sized Al(2)O(3) could selectively adsorb the inorganic selenium [Se(IV), Se(VI)], and the retained inorganic selenium could be eluted by 0.2 mol l(-1) NaOH, while the organic Se [selenocystine (SeCys(2)) and selenomethionine (Se-Met)] was not retained. On the other hand, the second column packed with mesoporous TiO(2) chemically modified by dimercaptosuccinic acid (DMSA) could selectively adsorb Se(IV) and SeCys(2) and barely adsorb Se(VI) and Se-Met. When the sample solution was passed through the column 1, separation of inorganic selenium and organic selenium could be achieved first. Then, the effluent from column 1 was successively introduced into the column 2 and the speciation of organic selenium could be attained due to the different adsorption behaviors of Se-Met and SeCys(2) on DMSA modified TiO(2). After that, the eluent from column 1 contained Se(IV), and Se(VI) was adjusted to desired pH and injected into column 2, and the speciation of Se(IV) and Se(VI) could also be realized thanks to their different retention on column 2. The parameters affecting the separation were investigated systematically and the optimal separation conditions were established. The detection limits obtained for Se(IV), Se(VI), Se-Met and SeCys(2) were 45-210 ng l(-1) with precisions of 3.6-9.7%. The proposed method has been successfully applied for the speciation of dissolved inorganic and organic selenium in environmental and biological samples. In order to validate the methodology, the developed method was also applied to the speciation of selenium in certified reference material of SELM-1 yeast, and the determined values were in good agreement with the certified values.  相似文献   

8.
For selenium speciation analysis, the hyphenation of chromatographic separation with element-specific detection has proved a useful technique. A powerful separation system, which is capable of resolving several biologically and environmentally important selenium compounds in a single column, is greatly needed. However, that has been difficult to achieve. In this paper eight selenium compounds, namely, selenite [Se(IV)], selenate [Se(VI)], selenocystine (SeCys), selenourea (SeUr), selenomethionine (SeMet), selenoethionine (SeEt), selenocystamine (SeCM) and trimethylselenonium ion (TMSe+), were separated by using mixed ion-pair reagents containing 2.5 mM sodium 1-butanesulfonate and 8 mM tetramethylammonium hydroxide as a mobile phase. The separation of these anionic, cationic and neutral organic selenium compounds on a LiChrosorb RP18 reversed-phase column took only 18 min at a flow-rate of 1.0 ml/min with isocratic elution, and baseline separation among the six organic Se compounds was achieved. Inductively coupled plasma mass spectrometry (ICP-MS) was employed as element-specific detection. A comparison of ICP-MS signal intensity obtained with a Barbington-type nebulizer and with an ultrasonic nebulizer (USN) was made. Different signal enhancement factors were observed for the various selenium compounds when a USN was used. The speciation technique was successfully applied to the study on chemical forms of selenium in a selenium nutritional supplement. Selenomethionine was found to be the predominant constituent of selenium in the supplement.  相似文献   

9.
This work addresses a metrological approach for the assessment of Se status in humans in terms of serum selenomethionine (SeMet). The quantification of SeMet was carried out using a primary method of chemical analysis, namely species-specific isotope dilution (SSID) in combination with HPLC coupled to collision/reaction cell inductively coupled plasma-mass spectrometry. SeMet was released from the serum selenoalbumin (a seleno-containing protein where SeMet is randomly incorporated) by enzymatic hydrolysis of the whole serum. This study is a follow-up of the analytical method development reported previously, and it focuses primarily on the evaluation of the uncertainty budget and the main uncertainty sources for SeMet determination in three commercial serums, namely BCR-637 (certified for total Se) and two serum standards, SERONORM level 1 (SERO-L1) and 2 (SERO-L2) (with indicative concentrations of total Se). The metrological approach reported here could be considered as a pilot study in terms of metrological determination of SeMet in human serum, hence being suitable for method validation and inter-laboratory comparison.  相似文献   

10.
王振华  何滨  史建波  阴永光  江桂斌 《色谱》2009,27(5):711-716
建立了一种利用高效液相色谱-双通道原子荧光检测联用同时进行砷和硒形态分析的方法。以10 mmol/L NH4H2PO4溶液(pH 5.6)(添加2.5%(体积分数)的甲醇)为流动相,在12 min内同时分离了三价砷(As(III))、一甲基砷(MMA)、二甲基砷(DMA)、五价砷(As(V))、硒代胱氨酸(SeCys)、硒代蛋氨酸(SeMet)和四价硒[Se(IV)]等化合物。As(III)、DMA、MMA、As(V)、SeCys、SeMet和Se(IV)的检出限分别为1,3,2,3,4,18和3 μg/L (进样量为200 μL),5次测定的相对标准偏差为1.9%~6.1%(As 100 μg/L, Se 300 μg/L)。应用该方法对人体尿样及硒酵母片中砷和硒的形态进行了分析,目标物在尿样中的加标回收率为83%~108%,在硒酵母片中的加标回收率为88%~105%。实验结果表明,该方法可用于尿样及药品中砷和硒形态的日常分析。该方法减少了样品的分析时间和试剂用量,降低了工作强度,提高了工作效率。  相似文献   

11.
In-vivo and in-vitro gastrointestinal (GI) extractions, also known as oral bioaccessibility and bioavailability, are important approaches to assess chemical risk to humans. We give an overview of in-vivo and in-vitro bioaccessibility and bioavailability assays for testing arsenic, selenium and mercury (As, Se and Hg) species from food samples. We critically evaluate the parameters affecting in-vivo and in-vitro processes. In addition, we consider the effect of cooking food on bioaccessibility and bioavailability, and stability and transformation, of species during in-vivo or in-vitro processes. The bioaccessibility and bioavailability of As, Se and Hg species are affected by the sample matrix, cooking food and the experimental conditions applied (gastric and intestinal pH, incubation temperature and residence time). Regarding species degradation and transformation during in-vitro procedures, good stability has been observed for most As species, except for certain arsenosugars. Important transformations during in-vitro processes have been reported for Se species [e.g., conversion of γ-glu-Se-MeSeCys to Se-MeSeCys, and organic Se species (MeSeCys, SeCys2 and SeMet) degradation to inorganic Se]. Finally, we summarize speciation and detection conditions for As, Se and Hg speciation, and quality control to assure reliable measurements.  相似文献   

12.
A technique for the speciation of selenomethylcysteine (SeMeCys), selenocystine (SeCys), selenite [Se(IV)] and selenomethionine (SeMet) was established in this paper using high-performance anion-exchange chromatography coupled with atomic fluorescence spectrometry (HPAEC-AFS). Analytes were separated on an AminoPac PA10 column and then digested by on-line ultraviolet (UV) irradiation, which destroyed organic compound structure. Hydride generation was used as an available sample introduction technique for atomic fluorescence detection. The detection limits of four compounds were 1-5 microg/L (250 microL injection, 10 times of the baseline noise). The relative standard deviations (RSDs), calculated from seven consecutive injections of 100 microg/L standard mixtures, were from 2 to 4%. Selenious yeast tablet, which had been proposed as selenium supplement, and human urine collected from a volunteer were analyzed. Good spiked recoveries from 86 to 103% were obtained.  相似文献   

13.
硒酵母中有机硒及硒代氨基酸含量的测定方法   总被引:32,自引:0,他引:32  
报道了人工培养硒酵母中有机硒及硒代胱氨酸(SeCys)和硒代蛋氨酸(SeMet)含量的测定方法。采用透析处理法使硒酵母中的无机硒和有机硒得以分离,并采用催化分光光度法测定了硒酵母中有机硒的含量;采用氨基酸自动分析仪测定了硒酵母中SeCys和SeMet的含量。  相似文献   

14.
建立了用离子抑制色谱法分析二(2,2,6,6-四甲基-4-哌啶基)马来酸酯合成反应液的方法。平均回收率为98.8%,相对标准偏差为0.56%,测量的平均相对偏差不大于5.0%,方法简单,快速,可用于工艺条件的选择和质量检测。  相似文献   

15.
Electrochemical oxidation of selenocystine (SeCys) and selenomethionine (SeMet), on a gold electrode was studied by cyclic voltammetry (CV), rotating disk electrode technique (RDE) and chronocoulometry (CC). In 0.2 mol/L HAc-NaAc (pH = 3.90) supporting electrolyte, anodic peak I potential of SeCys and SeMet was 810 mV and 638 mV, respectively, and this electrode process was diffused controlled. The electrochemical oxidation process of SeCys, in which six electron-transfers were involved, yielded selenocystine selenoxide. The electrochemical oxidation process of SeMet, in which two electron-transfers were involved, yielded selemethionine selenoxide.  相似文献   

16.
硒代胱氨酸和硒代蛋氨酸电化学检测的比较   总被引:7,自引:0,他引:7  
对硒代胱氨酸 (SeCys)和硒代蛋氨酸 (SeMet)在银电极上的电化学性质、电极反应机理及检测灵敏度等方面进行比较研究。实验表明 ,两者在pH9.5的硼砂 氢氧化钠介质中 ,于 -0 .62V和 -0 .68V(vs.SCE)处均存在一对氧化还原峰 ,电化学行为相似 ,两者具有良好的线性范围和低检出限 ,SeMet比SeCys具有更高的检测灵敏度。在相同的实验条件下 ,比较了含硫氨基酸与含硒氨基酸的电化学响应 ,含硫氨基酸的检测灵敏度远低于含硒氨基酸  相似文献   

17.
18.
A new derivatization–extraction method for preconcentration of seleno amino acids using hollow fiber liquid phase microextraction (HF‐LPME) was developed for the separation and determination of seleno amino acids in biological samples by gas chromatography–inductively coupled plasma mass spectrometry (GC–ICP‐MS). Derivatization was performed with ethyl chloroformate (ECF) to improve the volatility of seleno amino acids. Parameters influencing microextraction, including extraction solvent, pH of sample solution, extraction time, stirring speed, and inorganic salt concentration have been investigated. Under the optimal conditions, the limits of detection (LODs) obtained for Se‐methyl‐selenocysteine (SeMeCys), selenomethionine (SeMet), and selenoethionine (SeEth) were 23, 15, and 11 ng Se l−1, respectively. The relative standard deviations (RSDs) were 14.6%, 16.4%, and 19.4% for SeMeCys, SeMet, and SeEth (c = 1.0 ng ml−1, n = 7), respectively, and the RSDs for SeMeCys, SeMet could be improved obviously if SeEth was utilized as the internal standard. The proposed method was applied for the determination of seleno amino acids in extracts of garlic, cabbage, and mushroom samples, and the recoveries for the spiked samples were in the range of 96.8–108% and 93.4–115% with and without the use of SeEth as internal standard. The developed method was also applied to the analysis of SeMet in a certified reference material of SELM‐1 yeast and the determined value is in good agreement with the certified value. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
J. Zheng  W. Kosmus 《Chromatographia》2000,51(5-6):338-344
Summary Separation of seven inorganic and organic selenium compounds, namely selenic acid [Se(VI)], selenous acid [Se(IV)], trimethylselenonium iodide (TMSe+), selenocystine (SeCys), selenomethionine (SeMet), selenoethionine (Seet), and selenocystamine (SeCM), has been performed on a LiChrosorb C 18 column by using mixed ion-pair reagents; 1-butanesulfonic acid and tetramethylammonium hydroxide. Flame atomic absorption spectrometry (FAAS) was used as an element-specific detector. The retention behaviors of selenium compounds in terms of several chromatographic parameters, such as pH of the mobile phase, the concentrations of ion-pair reagents, and the content of organic modifier (methanol) were investigated. It was found that the separation of both inorganic and organic selenium compounds can be achieved within 12 min with a mobile phase of 10 mM 1-butanesulfonic acid −4 mM tetramethylammonium hydroxide −4 mM malonic acid −0.05% methanol adjusted to pH 4.5 at a flow rate of 1.0 mL min−1. The results obtained in this study showed that the use of mixed ion-pair reagents is very useful to improve the separation of selenium compounds. The applicability of this technique for the speciation of selenium compounds in real samples was demonstrated by the determination of selenium compounds in a selenium nutritional supplement. The results were found to be in good agreement with those obtained by ion-exchange HPLC-ICP-MS.  相似文献   

20.
Wang B  Xie L  Lin Y  Yan Z  Wang L 《色谱》2011,29(3):223-227
建立了高效液相色谱-电感耦合等离子体质谱(HPLC-ICP-MS)联用检测硒酸盐(SeVI)、亚硒酸盐(SeIV)、硒代蛋氨酸(SeMet)、硒代胱氨酸(SeCys2)和硒代乙硫氨酸(SeEt)的方法。采用Hamilton PRP X-100色谱柱(250 mm×4.6 mm, 5 μm),使用5 mmol/L的柠檬酸溶液(pH 4.5)作为流动相,电感耦合等离子体质谱(ICP-MS)检测,在21 min内可以完全分离5种硒形态。各形态硒的线性相关系数均大于0.9995, SeVI、SeIV、SeMet、SeCys2、SeEt的检出限分别为0.4、0.4、5.6、0.9、1.2 μg/L。探讨了不同提取方法的提取效果,鲜蘑菇和猪肉样品加标回收实验表明,对水溶性良好的无机硒和硒代蛋氨酸而言,采用柠檬酸溶液提取的效果非常好,SeIV和SeVI的回收率均在100%左右,SeMet的回收率为85.0%~95.3%;用蛋白酶水解提取,SeCys2和SeEt的回收率为79.9%~91.5%。该方法可完全满足食品中这5种硒形态的准确定量分析。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号