首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
In a canine model the signal dynamics of a new oligomer-based MR contrast agent (NMS60, 2158 Da) were compared to Gd-DTPA to investigate the agents' potential for magnetic resonance angiography (MRA). Twelve male mongrel dogs were imaged sequentially under anesthesia with two different MRA sequences (Tlw 3DSPGR). Initial enhancement was measured every 9 s for eight points in time. Thereafter, spatial highly resolved MRAs were obtained at 5, 10, 15, 20, 30, 45, and 60 min post-injection of two different dosages. Over the first 20 s following bolus administration the average arterial enhancement of 0.1 mmol(Gd)kg NMS60 was 44% greater than Gd-DTPA. Twenty minutes post-injection the relative signal intensity of NMS60 was as high as the peak signal intensity with Gd-DTPA at the same dosage level (0.1 mmol(Gd)/kg). In the animals that received NMS60 injections the vascular conspicuity was overly superior to those who received Gd-DTPA. No significant toxicity effects were noted for either dosage level. The intermediate weight contrast agent NMS60 offers greater vascular enhancement and retention time than Gd-DTPA. For a given set of optimized imaging parameters this offers improved spatial details, less arterial/venous overlap, and better vascular contrast.  相似文献   

2.
A novel mechanism of MRI contrast enhancement, based on the detection by a balanced steady-state free precession (SSFP) sequence of the proton resonance frequency shift induced by bulk magnetic susceptibility (BMS) contrast agents, was investigated. The potential for this contrast mechanism to image blood vessels was explored. The relaxation time and the frequency shift effects of gadolinium- and dysprosium-DOTA on SSFP signal was first simulated and evaluated on a water phantom at 1.5 T. In vitro, a 5-mM concentration in contrast agent induced a 20-Hz frequency shift, leading to a signal increase of 92% for Dy-DOTA, and a 10-Hz frequency shift, leading to a signal increase of 58% for Gd-DOTA at the reference frequency, taking into account the nonlinear SSFP signal response on frequency offset. The concept was then evaluated in vivo on anesthetized rabbits. Low doses of dysprosium-DOTA were injected in their vascular system, and imaging was performed at the level of neck vessels. Following a bolus injection, mean signal changes of 31%, 20% and 14% were observed in the carotid arteries, the vertebral veins and the jugular veins, respectively. The bolus peak times in arteries and veins were consistent with the rabbit vascular circulation. This frequency-shift based contrast mechanism presents interesting potential for contrast-enhanced MR angiography (CE-MRA) compared to usual relaxation-based contrast, but further investigations on reproducibility will be necessary.  相似文献   

3.
We describe the use of perfusion-permeability magnetic resonance imaging (ppMRI) to study hemodynamic parameters in human prostate tumor xenografts, following treatment with the vascular endothelial growth factor-A (VEGF) receptor tyrosine kinase inhibitor, ZD4190. Using a macromolecular contrast agent (P792), a fast MR imaging protocol and a compartmental data analysis, we were able to demonstrate a significant simultaneous reduction in tumor vascular permeability, tumor vascular volume and tumor blood flow (43%, 30% and 42%, respectively) following ZD4190 treatment (100 mg/kg orally, 24 h and 2 h prior to imaging). This study indicates that MR imaging can be used to measure multiple hemodynamic parameters in tumors, and that tumor vascular permeability, volume and flow, can change in response to acute treatment with a VEGF signaling inhibitor.  相似文献   

4.
Quantitative magnetic resonance (MR) images of flow velocities in intact corn plants were acquired using magnetization-prepared MR microscopy. A phase contrast flow imaging technique was used to quantitate water flow velocities and total volume flow rates in small xylem vessels. The simultaneous measurement of the transpiration of the whole plant was achieved by using a closed climate chamber within the MR magnet. The total volume flow rate and the transpiration values were in close correlation. Functional magnetic resonance imaging in intact plants was performed by light stimulation of the transpiration inside of the magnet. The change in the flow velocities in the xylem vessels of single vascular bundles was in correlation with the changes in the transpiration. Significant differences were observed between the xylem vessels in different vascular bundles. Furthermore, flow velocity measurements were performed on excised plant stems and visualized by the uptake of the MR contrast agent, gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA). A comparison between the phase contrast flow imaging and the contrast media uptake showed to be in good agreement with each other.  相似文献   

5.
Comparison of the effectiveness of various gastrointestinal (GI) contrast agents for magnetic resonance (MR) imaging is often complicated by varying amounts intraluminal filling with the orally administered agents. To achieve more uniform and reproducible imaging results with GI contrast agents for MR imaging (GICMR), we evaluated a radiographic method for monitoring intraluminal filling and distribution. Solutions of Mn-DPDP (2 mM), to which a small amount of barium sulfate (6 wt/vol%) was added, were administered orally to dogs. Gastric emptying and small bowel transit were monitored fluoroscopically. MR imaging was performed either 1) at a fixed time after administration of the contrast agent or 2) at a variable interval when the contrast agent was observed fluoroscopically to be in the terminal ileum. When initiation of MR imaging was guided by fluoroscopic monitoring of intestinal contrast distribution, uniform and reproducible intestinal contrast enhancement by GICMR was achieved. However, when MR imaging was performed at a fixed time interval after oral administration, non-uniform and variable GI visualization was obtained, and this corresponded to the variable intestinal distribution observed fluoroscopically. We conclude that reproducible intestinal filling with orally administered contrast agents can be accomplished with a radiographic monitoring technique, and this promotes more consistent GI visualization on MR images. Such standardized and reproducible methods are necessary for studies in which the effectiveness of GI contrast media for MR imaging is evaluated and compared.  相似文献   

6.
We have synthesized a surface functionalized superparamagnetic iron oxide colloid whose clearance from the vascular compartment was inhibited by asialofetuin but not fetuin. Unlike other particulate or colloidal magnetic resonance (MR) contrast agents, the agent of the current communication is not withdrawn from the vascular compartment by cells of the macrophage-monocyte phagocytic system, as indicated by its selective increase in hepatic relaxation rates. Because of this we refer to this colloid as a hepatic selective (HS) MR contrast agent. At 20 mumol Fe/kg the HS MR agent darkened MR images of liver. The HS MR agent exhibited no acute toxicity when injected into rats at 1800 mumol Fe/kg. Based on these observations, surface functionalized superparamagnetic iron oxide colloids may be the basis of MR contrast agents internalized by receptor mediated endocytosis generally, and by the asialoglycoprotein receptor in particular.  相似文献   

7.
In 3-D contrast-enhanced magnetic resonance (MR) angiography of the lower extremities the goal is most often to enhance arterial structures while keeping veins and surrounding tissue unenhanced. Imaging during steady-state concentration of a blood pool agent or during poor timing of an extra-cellular contrast medium may result in simultaneous venous enhancement, making interpretation of the angiogram difficult. The aim of this study was to develop a post-processing method to separate the arteries from the veins in standard contrast-enhanced MR angiograms. The method was based on the different accumulation of flow-induced phase in the arteries and veins of the lower extremities. The method was tested in both phantom experiments and volunteers undergoing 3-D contrast-enhanced MR angiography using both an extra-cellular contrast medium and a blood pool agent. In the phantom studies, opposite directional flow was successfully separated at mean flow velocities as low as 9 cm/s. In the volunteer studies, the larger veins were successfully extinguished while the larger arteries were left unaffected. In smaller vessels with low flow velocities the separation was less successful. This was most apparent in vessels not oriented superior-inferior. The method developed here is promising for separating arteries from veins in contrast-enhanced MR angiography although the results could be further improved by either a different pulse sequence design or combining this method with other segmentation methods.  相似文献   

8.
Fast magnetic resonance (MR) imaging provides a consistent and predictable appearance of vascular abnormalities as shown by four patients with thrombi, dissection and aneurysm. Fast MR images are obtained during breath-holding, resulting in an absence of respiratory motion artifacts. The time of MR study is much less with fast MR than with spin echo sequences.  相似文献   

9.
This case report is a unique presentation of a new potential indication for Gadofosvest (Ablavar), a blood pool contrast agent for magnetic resonance angiography (MRA). Ablavar is an excellent MRA contrast agent because it provides optimal contrast opacification of both the arterial and venous system, unlike the conventional extracellular agents that are used for arterial imaging only. The present case report demonstrates the ability of Ablavar to demonstrate pulmonary arteriovenous malformation (AVM), showing both its arterial feeders as well as its venous drainage tract.  相似文献   

10.
MRI of blood volume with MS 325 in experimental choroidal melanoma   总被引:2,自引:0,他引:2  
Functional magnetic resonance imaging (MRI) allows quantitative blood volume imaging in vivo at high tissue resolution. The purpose is to apply this technique for untreated and hyperthermia-treated experimental choroidal melanoma. MS 325 was used as new intravascular albumin-bound gadolinium-based contrast agent. Pigmented choroidal melanomas were established in albino rabbits. MRI was performed in 7 untreated eyes and 7 eyes treated with a Neodymium:Yttrium-Lanthanum-Fluoride-laser at 1047 nm. 3D-spoiled gradient echo pulse sequences were used to acquire T' weighted axial images. First, a set of images was collected without contrast agent. MS 325 was then injected i.v. and images were obtained within 12 min after injection. Signal intensities were measured within tumor, ciliary body, choroid, and iris and relative signal intensities were determined for these tissues in relation to vitreous. In untreated tumors, the relative signal intensity was higher after injection of MS 325 (5.61+0.70) than without MS 325 (2.90+0.33; p = 0.0002). In contrast, the relative signal intensity of treated tumors did not differ significantly before and after MS 325 (6.19+1.59 and 6.13+1.64). Histopathological sections indicated vascular occlusion in treated tumors. All other studied tissues of untreated and treated eyes showed a significant increase of relative signal intensities in the presence of MS 325. An animal model for the research on contrast agents in MRI is presented. Blood volume measurement with MS 325 was adapted for experimental choroidal melanomas. Reduced change of relative signal intensity indicates compromised blood volume after vascular occlusion in hyperthermia-treated melanoma. Further studies are needed to investigate whether this technique allows the evaluation of tumor viability following treatments.  相似文献   

11.
To evaluate efficacy and safety of a superparamagnetic iron oxide contrast agent (ferristene) as an endoluminal contrast medium for magnetic resonance (MR) enteroclysis in a phase III trial. Twenty-three patients with history of known or suspected small bowel Crohn's disease underwent MR imaging of the abdomen at 0.5 T unit. The imaging protocol included two phases: the first one without administration of any contrast agent and the second one, where the small bowel was filled by enteroclysis with 800 ml of the luminal iron oxide contrast medium and Gd-DTPA (0.1 mmol/Kg) was administered intravenously. Axial Spin-Echo (SE) T1-weighted (T1w), proton-density and T2w images, sagittal and coronal SE T1w and Short TI Inversion Recovery (STIR) sequences were subsequently obtained. Three investigators blindly evaluated images to determine small bowel distribution of ferristene, presence of artifacts, delineation of bowel lesion/wall and the diagnostic value of ferristene combined with gadolinium. Pre- and postcontrast signal intensity measurements of bowel lesion/wall, bowel lumen and background noise were also calculated. Three patients withdrew before the procedure, therefore 20 patients were effectively included in the study. No significant difference between the three investigators' evaluations of the improvement of the diagnostic information was found (percentage of improvement of 90% with 95% confidence limits of 68% and 99%). A statistically significant difference between the first and third investigators was found for grading of quality of delineation of bowel lesion/wall. Signal intensity measures showed a significant increase of the bowel lesion/wall and background noise/lesion for the SE T1w images. No serious adverse event was reported in our series. MR enteroclysis using ferristene as an endoluminal contrast agent appears to be a safe and efficient procedure for the study of the small bowel.  相似文献   

12.
Gadolinium DTPA was evaluated as an intravenous contrast agent for magnetic resonance imaging in 15 patients with primary or secondary intracranial neoplastic disease. T1 and T2 weighted images were obtained prior to contrast administration. T1 weighted spin echo 35/800 (TE/TR) images were utilized to detect enhancement. The increase in signal intensity observed, identifying areas of breakdown of the blood-brain barrier (BBB), was similar in magnitude to the contrast enhancement observed on CT. This permitted differentiation of neoplastic tissue from surrounding cerebral edema on MRI. Direct visualization of otherwise "isomagnetic" lesions was also demonstrated. The use of intravenous contrast media should significantly extend the diagnostic potential and specificity of magnetic resonance imaging.  相似文献   

13.
Gradient eddy currents, induced in the surrounding conductive structures in a magnetic resonance (MR) magnet, are a major problem in MR imaging, in localized MR spectroscopy and in many other MR experiments. We present a comparison of three methods of measuring the gradient time characteristics and the time changes of basic magnetic fieldB 0 after the gradient is switched off. The methods are based on the selective excitation of a thin layer of the sample and on acquiring the MR signal obtained after the end of the gradient pulse and on the computation of the instantaneous frequency of the signal. At this point, the time gradient characteristic is proportional to the instantaneous frequency of the MR signal, which has a small signal-to-noise ratio. We use the characteristics measured to set the pre-emphasis parameters in a 200 MHz/200 mm MR scanner. From the results obtained by measurement it follows that all methods are convenient for simple and quick characterization of magnetic field gradient in MR tomographic magnets.  相似文献   

14.
Functional magnetic resonance imaging (fMRI) has become the method of choice for mapping brain activity in human subjects and detects changes in regional blood oxygenation and volume associated with local changes in neuronal activity. While imaging based on blood oxygenation level dependent (BOLD) contrast has good spatial resolution and sensitivity, the hemodynamic signal develops relatively slowly and is only indirectly related to neuronal activity. An alternative approach termed magnetic source magnetic resonance imaging (msMRI) is based on the premise that neural activity may be mapped by magnetic resonance imaging (MRI) with greater temporal resolution by detecting the local magnetic field perturbations associated with local neuronal electric currents. We used a hybrid ms/BOLD MRI method to investigate whether msMRI could detect signal changes that occur simultaneously at the time of the production of well-defined event-related potentials, the P300 and N170, in regions that previously have been identified as generators of these electrical signals. Robust BOLD activations occurred after some seconds, but we were unable to detect any significant changes in the T2*-weighted signal in these locations that correlated temporally with the timings of the evoked response potentials (ERPs).  相似文献   

15.
This study was to describe the synthesis of complexes of gadolinium diethylenetriaminepentaacetic acid conjugates of low-molecular-weight chitosan oligosaccharide Gd-DTPA-CSn (n = 6, 8, 11) as a new class of contrast agent as well as its magnetic property in a pilot magnetic resonance imaging. The efficacy of the contrast agent was assessed by measuring the longitudinal relaxivity (r1), FLASH imaging in phantoms in vitro and signal intensity in vivo of the rat abdominal axial imaging. The r1 of Gd-DTPA-CS11 was up to 11.65 mM− 1·s− 1, which was 3 times higher than that of the analogous MRI contrast agent Gd-DTPA in commercial use. In vivo MR images of rat obtained with Gd-DTPA-CS11 showed strong signal enhancement in liver and the vessels of the liver parenchyma during the extended period of time. The present study suggests that the new synthesized gadolinium complexes can be used as a new class of practical liver-specific MRI contrast agent because of its superior performance compared with Gd-DTPA.  相似文献   

16.
Contrast-enhanced magnetic resonance angiography (MRA) is a promising technique for coronary artery imaging. The blood signal changes during the contrast injection will result in image artifacts, blurring and relatively low signal-to-noise ratio, when the k-space segments from different cardiac cycles are combined to reconstruct the final image as “time averaged.” Thus, it is important to acquire data during maximal blood signal enhancement for first-pass, contrast-enhanced MRA, and relatively high temporal resolution is required. This work demonstrated the feasibility of highly constrained backprojection reconstruction for time-resolved, contrast-enhanced coronary MRA. With this method, the temporal resolution can be increased. In addition, coronary artery images around blood signal enhancement peak have significantly improved contrast-to-noise ratio and suppressed artifacts compared to the composite images which were collected during a much longer acquisition time during substantial blood signal changes.  相似文献   

17.
The purpose of this study was to evaluate the potential of superparamagnetic iron oxide particles (SPIO) as tissue specific contrast agent in magnetic resonance (MR) imaging in detection and characterization of focal hepatic lesions. We investigated 45 patients with focal hepatic lesions. T1-weighted SE (TR 650/TE 15 ms) and T2-weighted SE (TR 2015-2030/TE 45 and 90 ms) unenhanced images were obtained. After SPIO application we performed T1-weighted images with and T2-weighted images with and without fat suppression using the same image parameters. Liver signal intensity decreased by 74% (min 47%, max 83%) on T2-weighted images after application of the contrast agent. Benign lesions (FNH, adenoma) showed an average signal drop of 40% (min 20%, max 47%) whereas malignant lesions showed no significant change of signal intensity on post-contrast images. The mean tumor-to-liver contrast-to-noise ratio (C/N) was improved in all post-contrast sequences irrespective of the lesion type. An additional increase of tumor-to-liver contrast by use of fat suppression technique could be established in the slightly T2-weighted sequence (TE 45 ms). In metastases, divided in different size groups, we could determine a significant size relation of tumor-to-liver C/N. After SPIO application the number of detected lesions increased distinctly, especially small foci are more easily demonstrated. SPIO particles are a efficacious contrast agent for MR examinations of the liver. For tumor characterization T1- and T2-weighted pre- and post-contrast images are necessary. The T1-weighted sequences are helpful to differentiate benign lesions such as cysts and hemangiomas from malignant lesions. Detection and differential diagnoses of hepatic lesions are improved by use of the SPIO-particles.  相似文献   

18.
Sixteen magnetic resonance (MR) studies were performed in eight patients with mucopolysaccharidosis (MPS). In patients with Hunter, Hurler, and Scheie syndromes, multiple areas of increased signal intensity were noted in the periventricular white matter. Computerized tomography (CT) frequently failed to demonstrate these white matter lesions. Other findings included spinal cord compression, hydrocephalus and airway obstruction due to soft tissue thickening around pharynx. In patients with Morquio syndrome, cervical spine dislocation, spinal cord compression and hydrocephalus were diagnosed by MR. MR was superior compared to CT, plain films and plain tomography, as the narrowing caused by bone and soft tissue changes were better seen with MR. Our experience suggests that MR should be the primary imaging modality for the detection of cranial abnormalities in patients with MPS. High resolution surface coil imaging may be preferable to invasive procedures such as myelography and CT with intrathecal contrast agents for the evaluation of cervical spine disease.  相似文献   

19.
利用近红外光激发的光声血管造影成像   总被引:2,自引:0,他引:2       下载免费PDF全文
杨思华  阴广志 《物理学报》2009,58(7):4760-4765
利用近红外光结合对应波长的光吸收增强对照剂来实现在体小鼠脑皮层血管的光声成像.近红外光在生物组织上有较深的穿透能力;而作为光吸收增强剂的外源染料吲哚菁绿注射到血液系统后则增加了血管对光的选择性吸收,从而增强了血管光声信号的强度.实验在不破坏脑头皮和头盖骨的前提下,通过静脉注射吲哚菁绿,获得小鼠脑皮层血管的光声造影成像.光声重建的血管网络与小鼠脑部解剖照片相当符合.实验结果证明近红外光结合光吸收增强剂的光声血管造影技术对于开展光声脑功能成像,光声分子成像提供了潜在的可行性. 关键词: 光声成像 光吸收增强剂 血管造影 光声信号  相似文献   

20.
Currently, magnetic resonance (MR) is most useful as a means of providing distinct images of gross abnormalities in major blood vessels. While new advances and further refinements will continue, MR has proven its value as a convenient and effective diagnostic tool for the recognition and delineation of vascular abnormalities, such as acquired arteriovenous fistulae (AVFs). We report a case of a chronic, post-traumatic AVF, in which MR angiography provided excellent anatomic detail and angiographic correlation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号