1.
Preliminary results of 2‐D separation of test dye mixture using high‐performance thin‐layer chromatography (HPTLC) and pressurized planar electrochromatography (PPEC) are demonstrated. The advantage of 2‐D HPTLC/PPEC separation is based on different separation selectivities obtained in both HPTLC and PPEC systems. HPTLC RP18 W plates of 5×20 cm from Merck were used in the investigations. In the first dimension, a HPTLC process was performed using 5 cm length of the plate and in the second dimension PPEC separation was obtained applying plate of 20 cm length. PPEC process followed prewetting the chromatographic plate with sample zones on it, which were partly separated after first dimensional (HPTLC) separation. In the experiments, the modified version of PPEC device for 20 cm long chromatographic plate and the reservoir for prewetting the adsorbent layer were applied.  相似文献   

2.
Theoretical backgrounds, development, examples of separations, constructional details and principle of action of devices of pressurized planar electrochromatography (PPEC) are presented. Development of the mode is described in respect of operating variables (composition of the mobile phase, pressure exerted on adsorbent layer, mobile phase flow velocity, temperature of separating system, etc.) influencing separation efficiency (kinetic performance, repeatability, separation time). Advantages of PPEC such as high kinetic performance, short separation time and different separation selectivities, especially relative to conventional thin-layer chromatography, are described. Examples of two-dimensional separations are demonstrated to show high separation potential of the mode when combined with conventional thin-layer chromatography (TLC). The PPEC mode is in infancy stage of development, so its challenges are presented as well.  相似文献   

3.
Influence of buffer pH, buffer concentration and ratio of methanol to acetonitrile in ternary mobile phase on migration distance of enantiomers of phenylalanine, tyrosine and DOPA in pressurized planar electrochromatography (PPEC) and thin-layer chromatography (TLC) systems is presented and compared. The applied operating variables in PPEC system more strongly influence on separation selectivity of investigated solutes than those in TLC one. Higher separation efficiency of PPEC system relative to TLC one is also demonstrated.  相似文献   

4.
In a series of our previous papers we have investigated the influence of various variables on retention/migration of peptides in various high-performance thin-layer chromatography (HPTLC) and pressurized planar electrochromatography (PPEC) systems. Here we present a correlation of the selectivity of peptide separation in similar, as well as in various HPTLC and PPEC systems investigated before. Our results show that the selectivity in similar HPTLC and PPEC systems is quite different. This results from the share of electrophoresis in separation of solutes by PPEC. The results suggest that combination of HPTLC and PPEC, with properly selected separation conditions (the same, or even better—different for each technique), may be used for efficient two-dimensional separation of peptides. The best separation can be obtained if PPEC is carried out in two opposite directions (toward the cathode and the anode) simultaneously.  相似文献   

5.
In our previous paper we have presented the new prototype equipment and introduced a new analytical technique—high-performance/high-pressure layer electrochromatography (HPLEC), a combination of overpressured-layer chromatography (OPLC) and pressurized planar electrochromatography (PPEC). In this paper, the work of the equipment in various operational modes is investigated. Some difficulties and challenges related to various aspects of separation are discussed. The OPLC and HPLEC techniques are compared in terms of selectivity and performance. The results show that our equipment can be successfully used for singe- and multichannel OPLC and HPLEC separations in various sample application and detection modes. It includes the high-throughput, multichannel, and fully automated online separation of multiple samples simultaneously. The equipment allows for the independent optimization of various operational parameters. HPLEC combines the advantages of column/capillary and planar separation techniques while overcoming their limitations. It also combines the advantages and overcomes the drawbacks of OPLC and PPEC. It provides hydrodynamic flow of the mobile phase, irrespective of the voltage used and/or the mobile phase composition. Thus, any optimization of the composition and the voltage can be used independently. Both can be used to obtain the required selectivity of separation. The voltage can be used to facilitate the mobile phase flow and accelerate the analysis.  相似文献   

6.
ABSTRACT

Pressurized planar electrochromatography (PPEC) was applied to support qualitative toxicological chemical analysis performed with thin-layer chromatography (TLC) and UV–Vis spectrometry. Based on retention/migration distance data of substances obtained in TLC and PPEC systems and database of their wavelength maxima of remission UV–Vis spectra as well, a combined fit factor was calculated for substance identification. The involvement of PPEC, TLC, and UV–Vis spectral data together in calculation of the combined fit factor lead to its lower values for substances, which were not identical with reference, in comparison with those when the combined fit factor was calculated using TLC and spectral data only. The results evidence that involvement of PPEC data in qualitative toxicological chemical analysis performed with TLC and UV–Vis spectrometry enhances reliability of it.  相似文献   

7.
Pressurized planar electrochromatography (PPEC) is a separating technique in which an electric field is applied to force the mobile phase movement through a porous media (electroosmotic effect). High separation efficiency, fast separations and changes in separation selectivity in comparison to liquid chromatography, especially thin layer chromatography (planar chromatography, TLC), are features of this technique. Constructional methodological challenges to PPEC are obstacles to its development and application in laboratory practice. In this article, an attempt to overcome the challenges related to device construction and sample application/injection is described. The introduced device enables both prewetting of the adsorbent layer and electrochromatogram development with a single PPEC device. It also enables simultaneous application/injection of six samples on a chromatographic plate in a stream of the mobile phase (on-line application/injection). In addition, the PPEC chamber was equipped with a thermostat. The device is characterized by an impressive throughput in comparison to the other planar technique, TLC/HPTLC. Although the developed device still needs improvement, it is, in our opinion, a considerable step toward possible automation of this planar separation technique.  相似文献   

8.
JPC – Journal of Planar Chromatography – Modern TLC - We have investigated the use of pressurized planar electrochromatography (PPEC) and planar chromatography (TLC) for reversed-phase...  相似文献   

9.
In this work, separation of multicomponent mixtures containing components with the same and different electrophoretic mobility by using orthogonal pressurised planar electrochromatography is studied theoretically. Additionally, a simple way for determination of a maximum amount of mixture causing volume overload of flat/planar columns used in this technique is presented. In the next stage, effects of change in different parameters on process performance by simulation case studies are investigated. A comparative study of separation productivity of orthogonal pressurised planar electrochromatography with the continuous and periodic modes of mixture delivery and column chromatography is carried out.  相似文献   

10.
Planar electrochromatography (PEC) is an emerging technique for thin-layer chromatography (TLC) where electroosmosis is the driving force for the solvent, not capillary action. This allows for much faster and constant flow rates in turn yielding increased zone capacities and efficiencies. Instrumental designs have changed greatly over the last few years solving many of the initial instrumentation challenges. We have previously shown that low applied pressure (or no applied pressure) PEC instruments do not give linear voltage drops across the separation path length of a TLC plate, which in turn results in non-stable electroosmotic flow (EOF). By the use of our unique reader electrode grid we have the ability to monitor the potential at eight discrete positions throughout the 10-cm separation path length. We now show that high-pressure PEC instruments, most commonly referred to as pressurized planar electrochromatography (PPEC) do show a linear voltage drop and constant EOF. We compare plate equilibration times of PPEC and low-pressure PEC, use of increased field strengths, as well as sample application designs. In addition, we discuss the use of rhodamine B as a visual marker for reproducible migration and calculation of theoretical plates.  相似文献   

11.
JPC – Journal of Planar Chromatography – Modern TLC - Pressurized planar electrochromatography (PPEC) of dansyl (DNS) derivatives of amino acids in normal- and reversed-phase systems is...  相似文献   

12.
Examples of separations of four mixtures of pesticides by pressurized planar electrochromatography (PPEC) under different operating conditions are presented. The samples were separated on a prewetted RP-18W chromatographic plate in a system with acetonitrile-buffer as the mobile phase. A potential of 2.3 kV was applied to a 10 cm long plate to create the electric field. Reproducible retention of pesticides was obtained during PPEC in the closed system when the sorbent layer of the plate was prewetted and equilibrated with the mobile phase. The reported separations of pesticides by PPEC are over 10 times faster than the corresponding separations by TLC.  相似文献   

13.
Three modes of sample application on the chromatographic plate are applied at present investigations of pressurized planar electrochromatography (PPEC) systems taking into special attention their influence on performance of the separating system. These modes are as follows: application of the sample solution directly on the chromatographic plate with microsyringe, deposition of sample solution on scrap of adsorbent layer followed by location oft this scrap on the chromatographic plate, application of the sample solution with commercially available aerosol applicator. These modes were combined with prewetting procedures of the chromatographic plates which lead to an accomplishment of equilibration of the stationary phase-mobile phase system. The plots of plate height versus linear flow rate of the mobile phase are presented for PPEC systems for the first time. The best separation performance has been obtained in PPEC system when prewetting of the chromatographic plate followed the sample application with commercially available aerosol applicator. The higher repeatability of migration distance of the solute bands has been obtained in PPEC experiments when the sample application was followed by prewetting the chromatographic plate in comparison to the experiments when these operations were performed in reversed order.  相似文献   

14.
薄层电色谱技术将电场力的作用引入薄层色谱的分离过程中,具有分离时间短、分辨率高等特点,将可能在物质分析分离中发挥重要作用.本文介绍了薄层电色谱仪器装置的设计、固定相和流动相的类型、薄层电色谱的应用等内容,总结了目前的研究工作中存在的主要问题,并展望了该技术未来的发展趋势,还介绍了与薄层电色谱有相似的毛细管电色谱和自由流电泳技术.引文献50篇.  相似文献   

15.
Kinetic performance, measured by plate height, of High-Performance Thin-Layer Chromatography (HPTLC), High-Performance Liquid Chromatography (HPLC) and Pressurized Planar Electrochromatography (PPEC) was compared for the systems with adsorbent of the HPTLC RP18W plate from Merck as the stationary phase and the mobile phase composed of acetonitrile and buffer solution. The HPLC column was packed with the adsorbent, which was scrapped from the chromatographic plate mentioned. An additional HPLC column was also packed with adsorbent of 5 μm particle diameter, C18 type silica based (LiChrosorb RP-18 from Merck). The dependence of plate height of both HPLC and PPEC separating systems on flow velocity of the mobile phase and on migration distance of the mobile phase in TLC system was presented applying test solute (prednisolone succinate). The highest performance, amongst systems investigated, was obtained for the PPEC system. The separation efficiency of the systems investigated in the paper was additionally confirmed by the separation of test component mixture composed of six hormones.  相似文献   

16.
A mixture of unsaturated fatty acid methyl esters was separated with a new splitless capillary set-up. With the employed apparatus configuration different capillary separation techniques such as capillary high-performance liquid chromatography (cHPLC), capillary electrochromatography (CEC) and pressurized capillary electrochromatography (pCEC) could be applied. The detection and identification of the sample compounds were accomplished by hyphenating these capillary separation techniques with nuclear magnetic resonance (NMR) spectroscopy using a novel configuration of the detection capillary set-up. Using modified electrokinetically driven separation techniques, the electric field was applied solely across the separation column. With this improved interface for capillary liquid chromatography-NMR on-line coupling, the stereochemical assignment of the cis and trans configuration of unsaturated fatty acids could be easily accomplished. Finally, the results of cHPLC-NMR, CEC-NMR and pCEC-NMR coupling experiments were compared.Dedicated to Professor Günter Häfelinger on the occasion of his 65th birthday  相似文献   

17.
谢敏杰  冯钰锜  达世禄 《色谱》2000,18(6):503-507
 毛细管电色谱是近年发展起来的高效、高选择性的微分离技术。与一般的毛细管电泳和使用ODS反相填料的毛细管电色谱相比 ,含离子涂层柱的毛细管电泳和毛细管电色谱能提供较大且可控的电渗流 ,便于拓宽分离对象 ,优化分离条件。对使用含离子涂层柱的毛细管电泳和电色谱的特点、发展和应用状况进行了综述。  相似文献   

18.
The aim of this work was to find a relationship between electroosmotic flow (EOF) velocity of the mobile phase in pressurized planar electrochromatography (PPEC) and physicochemical properties like zeta potential, dielectric constant, and viscosity of the mobile phase as well as its composition. The study included different types of organic modifiers (acetonitrile, methanol, ethanol, acetone, formamide, N-methylformamide and N,N-dimethylformamide) in the full concentration range. In all experiments, chromatographic glass plates HPTLC RP-18 W from Merck (Darmstadt) were used as a stationary phase. During the study we found that there is no linear correlation between EOF velocity of the mobile phase and single variables such as zeta potential or dielectric constant or viscosity. However, there is quite strong linear correlation between EOF velocity of the mobile phase and variable obtained by multiplying zeta potential of the stationary phase–mobile phase interface, by dielectric constant of the mobile phase solution and dividing by viscosity of the mobile phase. Therefore, it could be concluded that the PPEC system fulfilled the Helmholtz–Smoluchowski equation.  相似文献   

19.
纳米粒子以其较大的比表面积、良好的生物相容性而被广泛应用于分离科学领域. 纳米粒子毛细管电色谱(NPCEC)是纳米材料技术与毛细管电泳/电色谱(CE/CEC)技术相结合的产物.NPCEC技术是将不同基质的功能化纳米粒子加入电泳的运行缓冲液中,纳米粒子不仅可以通过动态吸附于毛细管壁而改变(或逆转)电渗流,还可作为准固定相(PSPs)参与样品在柱内的分配和保留,从而提高柱效和改善分离的选择性.该技术因无需填充和柱塞制备等步骤而日益受到关注.此外,NPCEC技术还可实现良好的柱更换,避免了进行复杂样品分析时所造成的柱污染.该文重点讨论在NPCEC实验中常用的几种纳米粒子的合成及应用,包括聚合物纳米粒子、二氧化硅纳米粒子、金纳米粒子、碳纳米管和树状聚合物,并对其发展前景进行了展望.  相似文献   

20.
毛细管电色谱中缓冲液离子强度对ODS柱分离行为的影响   总被引:1,自引:0,他引:1  
介绍了毛细管电色谱中流动相的选择以及缓冲液的不同离子强度对ODS柱分离行为的影响。  相似文献   