首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
ANi(AsF6)3 (A = O2+, NO+, NH4+) compounds could be prepared by reaction between corresponding AAsF6 salts and Ni(AsF6)2. When mixtures of AF (A = Li, Na, K, Rb, Cs) and NiF2 are dissolved in aHF acidified with an excess of AsF5 the corresponding AAsF6 and Ni(AsF6)2 were formed in situ. For A = Li and Na only mixtures of AAsF6 and Ni(AsF6)2 were obtained, while for A = K, Rb and Cs, the final products were ANi(AsF6)3 (A = K-Cs) compounds contaminated with AAsF6 (A = K-Cs) and Ni(AsF6)2.ANi(AsF6)3 (A = H3O+, O2+, NO+, NH4+ and K+) compounds are structurally related to previously known H3OCo(AsF6)3. The main features of the structure of these compounds are rings of NiF6 octahedra sharing apexes with AsF6 octahedra connected into infinite tri-dimensional network. In this arrangement cavities are formed where single charged cations are placed.In O2Ni(AsF6)3 the vibrational band belonging to O2+ vibration is found at 1866 cm−1, which is according to the literature data one of the highest known values, and it is only 10 cm−1 lower than the value for free O2+.  相似文献   

2.
The use of ion chromatography (IC) in conjunction with ultrasonic extraction is described for the routine analysis of water-soluble major inorganic ions and organic acids in atmospheric fine particles (PM2.5). Both the extraction method and the IC analysis were validated using NIST SRM 1648 (urban particulate matter). In addition, the reliability of the IC method was established by intercomparison of results obtained with those from suitable alternative analytical techniques (atomic absorption spectrometry (AAS), proton-induced X-ray emission (PIXE) spectrometry, and UV-Visible spectrophotometry). The validated IC method was successfully applied for field monitoring of PM2.5 particles collected in Singapore over an extended period of time. The IC analysis revealed that the concentrations of individual ions were in the order, SO42− > NH4+ > NO3 > Na+ > K+ > Cl, respectively. Among the major ionic components, SO42− contributed 50% to the measured water-soluble aerosol mass followed by NH4+ (16.5%) and NO3 (9.0%). The cations Na+, K+, Mg2+, and Ca2+ accounted for 24% of the total water-soluble mass. The IC analysis was performed to quantify the organic acids, which typically account for a small fraction of water-soluble organic compounds in PM2.5. Oxalate was found to be the dominant species among the organic acids measured in this work.  相似文献   

3.
A novel nonchromatographic speciation technique for the speciation of mercury by sequential cloud point extraction (CPE) combined with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed. The method based on Hg2+ was complexed with I to form HgI42−, and the HgI42− reacted with the methyl green (MG) cation to form hydrophobic ion-associated complex, and the ion-associated complex was then extracted into the surfactant-rich phase of the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114), which are subsequently separated from methylmercury (MeHg+) in the initial solution by centrifugation. The surfactant-rich phase containing Hg(II) was diluted with 0.5 mol L− 1 HNO3 for ICP-OES determination. The supernatant is also subjected to the similar CPE procedure for the preconcentration of MeHg+ by the addition of a chelating agent, ammonium pyrrolidine dithiocarbamate (APDC), in order to form water-insolvable complex with MeHg+. The MeHg+ in the micelles was directly analyzed after disposal as describe above. Under the optimized conditions, the extraction efficiency was 93.5% for Hg(II) and 51.5% for MeHg+ with the enrichment factor of 18.7 for Hg(II) and 10.3 for MeHg+, respectively. The limits of detection (LODs) were 56.3 ng L− 1 for Hg(II) and 94.6 ng L− 1 for MeHg+ (as Hg) with the relative standard deviations (RSDs) of 3.6% for Hg(II) and 4.5% for MeHg+ (C = 10 μg L−1, n = 7), respectively. The developed technique was applied to the speciation of mercury in real seafood samples and the recoveries for spiked samples were found to be in the range of 93.2–108.7%. For validation, a certified reference material of DORM-2 (dogfish muscle) was analyzed and the determined values are in good agreement with the certified values.  相似文献   

4.
The current work focuses on the application of nanofiltration (NF) to the isolation of a pharmaceutical product, clavulanate (CA), from clarified fermentation broths, which show a complex composition with five main identified ions (K+, Cl, NH4+, SO42− and CA). Our aim is to predict the rejection rates of these five ions, with the NF membrane Desal-DK, which may influence the separation of CA and play a role in the whole downstream process.  相似文献   

5.
The diffusion-controlled rate constants, kd, of various quenching reactions, [Ru(L)3]2+∗ (L = bpy, phen and 4,7-(CH3)2phen) + [Fe(CN)6]3−, were measured through fluorescence measurements. From them, the effective values of viscosity coefficients for several methanol + water mixtures were calculated. These coefficients were checked through calculations of the rate constants of the reaction [IrCl6]2− + [Ru(bpy)3]2+∗, which were also obtained by fluorescence quenching measurements. The agreement between the two sets of data (experimental and predicted) is excellent. Besides, the trends of association, kd, and dissociation, kd, rate constants for 2+/3−, 2+/2− and 2+/2+ reactions in methanol-water mixtures are discussed. The use of effective diffusion coefficients for estimating kd and kd allowed us to obtain the intrinsic electron transfer rate constant, ket, for the activation-diffusion-controlled process between [Ru(bpy)3]2+∗ and [Co(NH3)5Cl]2+ complexes from the observed (quenching) rate constant. The influence of methanol-water mixtures on ket was rationalized by using the Marcus electron-transfer treatment.  相似文献   

6.
We report the results of a calorimetric study on the hydrolysis of UO22+ in different ionic media (NaClO4 aq, NaClaq) at 25 °C. Experiments in NaCl were performed at different ionic strength, at I≤1 mol l−1. The species considered in both ionic media were UO2(OH)+, (UO2)2(OH)22+ and (UO2)3(OH)5+, and in addition (UO2)3(OH)42+ and (UO2)3(OH)7 in NaClaq. The dependence on ionic strength of enthalpy changes in NaClaq was expressed by the simple linear equation ΔHpqH°pq+aI1/2 (a, empirical parameter). Comparison with literature findings is given and some recommended values are reported.  相似文献   

7.
A gas chromatography–tandem mass spectrometric (GC–MS/MS) method has been established for the determination of cyanide in surface water. This method is based on the derivatization of cyanide with 2-(dimethylamino)ethanethiol in surface water. The following optimum reaction conditions were established: reagent dosage, 0.7 g L−1 of 2-(dimethylamino)ethanethiol; pH 6; reaction carried out for 20 min at 60 °C. The organic derivative was extracted with 3 mL of ethyl acetate, and then measured by using GC–MS/MS. Under the established conditions, the detection and quantification limits were 0.02 μg L−1 and 0.07 μg L−1 in 10-mL of surface water, respectively. The calibration curve had a linear relationship relationship with y = 0.7140x + 0.1997 and r2 = 0.9963 (for a working range of 0.07–10 μg L−1) and the accuracy was in a range of 98–102%; the precision of the assay was less than 7% in surface water. The common ions Cl, F, Br, NO3, SO42−, PO43−, K+, Na+, NH4+, Ca2+, Mg2+, Ba2+, Mn4+, Mn2+, Fe3+, Fe2+ and sea water did not interfere in cyanide detection, even when present in 1000-fold excess over the species. Cyanide was detected in a concentration range of 0.07–0.11 μg L−1 in 6 of 10 surface water samples.  相似文献   

8.
A method for estimation of uranium in seawater by using steady state laser flourimetry is described. Uranium present in seawater, in concentration of approximately 3 ng ml−1 was estimated without prior separation of matrix. Quenching effect of major ions (Cl, Na+, SO4, Mg+, Ca+, K+, HCO3, Br) present in seawater on fluorescence intensity of uranium was studied. The concentration of phosphoric acid required for maximum enhancement of fluorescence intensity was optimized and was found to be 5%. Similarly the volume of concentrated nitric acid required to eliminate the quenching effect of chloride and bromide completely from 5 ml of seawater were optimized and was found to be 3 ml. A simple equation was derived using steady state fluorescence correction method and was used for calculation of uranium concentration in seawater samples. The method has a precesion of 1% (1 s, n = 3). The values obtained from laser fluorimetry were validated by analyzing the same samples by linear sweep adsorptive stripping voltametry (LSASV) of the uranium-chloranilic acid (2,5-dichloro-3,6-dihydroxy-1,4-benzoquinone) complex. Both the values are well in agreement.  相似文献   

9.
A comprehensive thermodynamic model based on the electrolyte NRTL (eNRTL) activity coefficient equation is developed for the NaCl + H2O binary, the Na2SO4 + H2O binary and the NaCl + Na2SO4 + H2O ternary. The NRTL binary parameters for pairs H2O-(Na+, Cl) and H2O-(Na+, SO42−), and the aqueous phase infinite dilution heat capacity parameters for ions Cl and SO42− are regressed from fitting experimental data on mean ionic activity coefficient, heat capacity, liquid enthalpy and dissolution enthalpy for the NaCl + H2O binary and the Na2SO4 + H2O binary with electrolyte concentrations up to saturation and temperature up to 473.15 K. The Gibbs energy of formation, enthalpy of formation and heat capacity parameters for solids NaCl(s), NaCl·2H2O(s), Na2SO4(s) and Na2SO4·10H2O(s) are obtained by fitting experimental data on solubilities of NaCl and Na2SO4 in water. The NRTL binary parameters for the (Na+, Cl)-(Na+, SO42−) pair are regressed from fitting experimental data on dissolution enthalpies and solubilities for the NaCl + Na2SO4 + H2O ternary.  相似文献   

10.
A robotic method has been established for the determination of bromate in sea water and drinking deep-sea water. Bromate in water was converted into volatile derivative, which was measured with headspace solid-phase micro extraction and gas chromatography–mass spectrometry (HS-SPME GC–MS). Derivatization reagent and the HS-SPME parameters (selection of fibre, extraction/derivatization temperature, heating time and; the morality of HCl) were optimized and selected. Under the established conditions, the detection and the quantification limits were 0.016 μg L−1 and 0.051 μg L−1, respectively, and the intra- and inter-day relative standard deviation was less than 7% at concentrations of 1.0 and 10.0 μg L−1. The calibration curve showed good linearity with r2 = 0.9998. The common ions Cl, NO3, SO42−, HPO42−, H2PO4, K+, Na+, NH4+, Ca2+, Mg2+, Ba2+, Mn4+, Mn2+, Fe3+ and Fe2+ did not interfere even when present in 1000-fold excess over the active species. The method was successfully applied to the determination of bromate in sea water and drinking deep-sea water.  相似文献   

11.
Closed-vessel microwave digestion of nine standard reference plant materials (NIST, BCR, IAEA) and a laboratory standard of plant material with different Si contents assisted by HNO3 + H2O2 (procedure A), HNO3 + H2O2 + HF + H3BO3 (procedure B) and HNO3 + H2O2 + HBF4 (procedure C) were used to determine the recovery of 36 elements by ICP-MS: Ag, Al, As, Ba, Be, Bi, Cd, Ce, Co, Cr, Cs, Cu, Fe, Ga, Ge, In, La, Li, Mn, Mo, Nd, Ni, Pb, Pr, Rb, Sb, Se, Sn, Sr, Th, Tl, U, V, W, Y, Zn. Additions of HF + H3BO3 and HBF4 in procedures B and C exceeded by 10% (B1, C1) and 100% (B2, C2) the equivalent concentrations of Si in the samples determined by ICP-OES. Most recoveries of certified elements (e.g., Al*, Cu, Mo*, Rb*, Sb*, Th) decreased significantly (*p ≤ 0.05) with increasing Si content in plant reference materials digested by procedure A, while the recoveries from procedures B and C decreased insignificantly only for Mo and Sb. Digestions B and C gave significantly higher recoveries of Al, Sb, W and REEs, which were tighter to the reference values of these elements. A similar effect was found for Cu, Fe, Li, Ni, Sn, Th, Tl, V, Zn, Ba, Rb and Sr recoveries in samples with Si contents exceeding 2000 μg g−1. If the Si content in plant samples is less than 10 mg g−1, digestion of 0.5 g of plant samples through 0.05 mL of HF and 0.5 mL of 4% H3BO3 or 0.1 mL of HBF4 is recommended to get satisfactory results for most of the elements. For materials with Si content exceeding 10 mg g−1 the weight of the sample for digestion should be reduced to 0.25 g. However, the operation of potential interferences should be taken into account and eliminated through correction equations and adequate dilution of the samples.  相似文献   

12.
An artificial neural network (ANN) procedure was used in the development of a catalytic spectrophotometric method for the determination of Cu(II) and Ni(II) employing a stopped-flow injection system. The method is based on the catalytic action of these ions on the reduction of resazurin by sulfide. ANNs trained by back-propagation of errors allowed us to model the systems in a concentration range of 0.5-6 and 1-15 mg l−1 for Cu(II) and Ni(II), respectively, with a low relative error of prediction (REP) for each cation: REPCu(II) = 0.85% and REPNi(II) = 0.79%. The standard deviations of the repeatability (sr) and of the within-laboratory reproducibility (sw) were measured using standard solutions of Cu(II) and Ni(II) equal to 2.75 and 3.5 mg l−1, respectively: sr[Cu(II)] = 0.039 mg l−1, sr[Ni(II)] = 0.044 mg l−1, sw[Ni(II)] = 0.045 mg l−1 and sw[Ni(II)] = 0.050 mg l−1. The ANNs-kinetic method has been applied to the determination of Cu(II) and Ni(II) in electroplating solutions and provided satisfactory results as compared with flame atomic absorption spectrophotometry method. The effect of resazurin, NaOH and Na2S concentrations and the reaction temperature on the analytical sensitivity is discussed.  相似文献   

13.
In this paper, we describe a validation procedure for chemical fractionation analysis of elements (Al, As, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, S, Sb, Si, Sr, Ti and V) and soluble ions (Cl, NO3, SO42−, Na+, NH4+, Mg2+, Ca2+) in suspended particulate matter (PM). The procedure applies three distinct measurement techniques (XRF, IC and ICP-OES) to the analysis of individual samples. The techniques used generate different outputs at different stages in the procedure. This makes it possible to identify the contributions of specific parameters to measurement uncertainty. On this basis, we propose a scheme for controlling the analytical quality of data from individual samples in which inter-technique comparisons is used in the same way many analytical methods use surrogates. We apply this scheme to about 310 samples of PM10 and PM2.5 identifying and assessing the main factors contributing to measurement uncertainty. This procedure successfully resolved a number of difficulties frequently encountered during the analysis of PM, including lack of appropriate reference materials and the low reliability of alternative techniques of quality control. The results demonstrate the critical importance of sample treatment prior to destructive analysis by IC and ICP.  相似文献   

14.
Cellulose acetate fibers with supported highly dispersed aluminum phosphate were prepared by reacting aluminum-containing cellulose acetate (Al2O3=3.5 wt.%; 1.1 mmol g−1 aluminum atom per gram of the material) with phosphoric acid. Solid-state NMR spectra (CPMAS 31P NMR) data indicated that HPO42− is the species present on the fiber surface. The specific concentration of acidic centers, determined by ammonia gas adsorption, is 0.50 mmol g−1. The ion exchange capacities for Li+, Na+ and K+ ions were determined from ion exchange isotherms at 298 K and showed the following values (in mmol g−1): Li+=0.03, Na+=0.44 and K+=0.50. The H+/Li+ exchange corresponds to the model of the ideal ion exchange with a small value of the corresponding equilibrium constant K=1.1×10−2. Due to the strong cooperative effect, the H+/Na+ and H+/K+ ion exchange is non-ideal. These ion exchange equilibria were treated with the use of models of fixed bi- or tridentate centers, which consider the surface of the sorbent as an assemblage of polyfunctional sorption centers. Both the observed ion exchange capacities with respect to the alkaline metal ions and the equilibrium constants were discussed by taking into consideration the sequence of the ionic hydration radii for Li+, Na+ and K+. The matrix affinity order for the ions decreases as the hydration radii of the cations increase, i.e. Li+>Na+>K+. The high values of the separation factors SNa+/Li+ and SK+/Li+ (up to several hundred) provide quantitative separation of Na+ and K+ from Li+ from a mixture containing these three ions.  相似文献   

15.
A new ion-pair complex, [1-(4′-chlorobenzyl)-4-aminopyridinium](+)bis(maleonitrile-dithiolato)nickel(−),[ClbzPyNH2][Ni(mnt)2] (1), has been prepared and characterized. X-ray single crystal structure conforms that the Ni(mnt)2 anions and [ClbzPyNH2]+ cations of 1 form completely segregated uniform stacking columns with the Ni?Ni distance 3.944 Å in the Ni(mnt)2 stacking column. The temperature dependence of the magnetic susceptibility reveals that 1 undergoes a magnetic transition, and exhibits ferromagnetic interaction in the high-temperature phase and spin gap system in the low-temperature phase.  相似文献   

16.
Silica gel chemically bonded with aminothioamidoanthraquinone was synthesized and characterized. The metal sorption properties of modified silica were studied towards Pb(II), Cu(II), Ni(II), Co(II) and Cd(II). The determination of metal ions was carried out on FAAS. For batch method, the optimum pH ranges for Pb(II), Cu(II) and Cd(II) extraction were ≥3 but for Ni(II) and Co(II) extraction were ≥4. The contact times to reach the equilibrium were less than 10 min. The adsorption isotherm fitted the Langmuir's model showed the maximum sorption capacities of 0.56, 0.30, 0.15, 0.12 and 0.067 mmol/g for Pb(II), Cu(II), Ni(II), Co(II) and Cd(II), respectively. In the flow system, a column packed modified silica at 20 mg for Pb(II) and Cu(II), 50 mg for Cd(II), 60 mg for Co(II), Ni(II) was studied at a flow rate of 4 and 2.5 mL/min for Ni(II). The sorbed metals were quantitatively eluted by 1% HNO3. No interference from Na+, K+, Mg2+, Ca2+, Cl and SO42− at 10, 100 and 1000 mg/L was observed. The application of this modified silica gel to preconcentration of pond water, tap water and drinking water gave high accuracy and precision (%R.S.D. ≤ 9). The method detection limits were 22.5, 1.0, 2.9, 0.95, 1.1 μg/L for Pb(II), Cu(II), Ni(II), Co(II) and Cd(II), respectively.  相似文献   

17.
The synthesis, X-ray structure, magnetic and transport properties of the compound Ni(dmf)6[Ni(dsit)2]2 (dmf=dimethylformamide, dsit=1,3-dithiole-2-thione-4,5-diselenolate) are described. This compound crystallizes in the monoclinic space group P21/c, with a=18.709(6), b=22.975(5), c=20.418(5) Å, β=99.31(2)° and Z=6; its structure consists of [Ni(dsit)2]22− dimers and isolated [Ni(dmf)6]2+ cations both centrosymmetric and non-centrosymmetric. The dimers are packed forming chains along the [101] direction with short Se·Se interdimer contacts. Additional interchains S·S contacts render this structure a three-dimensional character, never observed so far in other [Ni(dsit)2] salts. This compound exhibits semiconducting behavior with a room temperature conductivity (1 S cm−1) much higher than those reported for other salts of the [Ni(dsit)2] anion. Tight-binding band structure calculations were used to analyze the origin of the semiconducting properties of this salt. The magnetic susceptibility shows Curie behavior with C=1.25 emu K mol−1, typical of isolated Ni(II) ions as expected for the octahedrally coordinated [Ni(dmf)6]2+ cations.  相似文献   

18.
Dimethyl-4,4-dimethoxy-5,6,5′,6′-dimethylene dioxy biphenyl-2,2-dicarboxylate (DDB) liver drug is used as a novel ionophore in plasticized poly (vinyl chloride) (PVC) matrix membrane sensors for barium ions. Optimum performance characteristics are displayed by membrane sensor incorporating DDB ionophore, potassium tetrakis(4-chlorophenyl)borate as lipophilic salt, and o-nitrophenyloctyl ether as plasticizer. The sensor exhibits a linear response over the concentration range 10−1-10−5 mol l−1 BaCl2 with a Nernstian slope of 30 mV per decade and high selectivity towards Ba2+ with respect to Li+, Na+, K+, Rb+, NH4+, Mg2+, Ca2+, Sr2+, Mn2+, Co2+, Ni2+, Cd2+, Al3+, La3+, and Ce3+ ions. The sensor response is stable over a wide pH range (4-9) and the lifetime is about 2 months. The proposed sensor is successfully applied to the determination of Ba2+contents of some rocks.  相似文献   

19.
Vapor-liquid equilibria (VLE) have been measured for five 1-hexene/n-hexane/ionic liquid systems and 1-hexene/n-hexane/NMP (N-methyl-2-pyrrolidone) system with a headspace-gas chromatography (HSGC) apparatus at 333.15 K. The ionic liquids investigated were 1,3-dimethylimidazolium tetrafluoroborate [C2MIM]+[BF4], 1-butyl-3-methylimidazolium tetrafluoroborate [C4MIM]+[BF4], 1-methyl-3-octylimidazolium tetrafluoroborate [C8MIM]+[BF4], 1,3-dimethylimidazolium dicyanamide [C2MIM]+[N(CN)2] and 1-octylquinolinium bis(trifluoromethylsulfonyl)amide [C8Chin]+[BTA]. It was found that at low feeding concentration of 1-hexene and n-hexane, the separation ability of ionic liquids is in the order of [C2MIM]+[BF4] > [C4MIM]+[BF4] ≈ [C2MIM]+[N(CN)2] > [C8MIM]+[BF4] > [C8Chin]+[BTA], which is consistent with the priori prediction of the COSMO-RS (conductor-like screening model for real solvents) model. But at high feeding concentration, the separation ability of ionic liquids is in the order of [C2MIM]+[BF4] < [C4MIM]+[BF4] ≈ [C2MIM]+[N(CN)2] < [C8MIM]+[BF4] < [C8Chin]+[BTA]. The liquid demixing effect should be taken into account. The activity coefficients of 1-hexene and n-hexane at infinite dilution calculated with the COSMO-RS model were correlated using the NRTL, Wilson and UNIQUAC model. In this work the predictive results from the COSMO-RS model and UNIFAC model for the 1-hexene/n-hexane and 1-hexene/n-hexane/NMP systems were compared. The UNIFAC model is one of the most important academic contributions by Prof. Jürgen Gmehling.  相似文献   

20.
Vlad M. Iluc 《Tetrahedron》2006,62(32):7577-7582
Addition of hydridosilanes, Ar2SiHX, to the labile Ni(0) benzene complex [(dtbpe)Ni]2(C6H6) (1; dtbpe=1,2-bis(di-tert-butylphosphino)ethane) gives mononuclear Ni(II) hydride silyl complexes of the formulation (dtbpe)Ni(μ-H)SiAr2X (2, X=H, Ar=Mes; 3, X=H, Ar=Ph; 4, X=Me, Ar=Ph; 5, X=Cl, Ar=Ph). Although the crystal structures of two representatives of the series indicate square-planar coordination around nickel, in solution structures having apparent C2v symmetry are observed. We propose that this behavior is due to a fluxional process that involves η2-SiH intermediates. Other data are also consistent with the facile reductive elimination of the silane to regenerate nickel(0) products. Oxidation of 2 and 3 with triphenylcarbenium tetrakis(pentafluorophenyl)borate results in silane elimination and formation of [(dtbpe)Ni(η3-C6H5CPh2)+][B(C6F5)4] (6), the structure of which shows the CPh3 ligand bound to a Ni(II) center through a phenyl ring in an η3-allylic fashion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号