首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Physical property studies of surfaces formed by chemisorption of polyethylene oxide (PEO) onto gold are reported. Such surfaces have potential as model materials for elucidation of the mechanism of resistance to protein adsorption by PEO surfaces. Thiolated monomethoxy poly(ethylene oxide) (PEO) was chemisorbed onto gold-coated silicon wafers under various conditions such that different surface chain densities were achieved. Chain density was varied by controlling PEO solubility (proximity to cloud-point conditions) as well as chemisorption time. Films prepared with PEO of molecular weight 750, 2000, and 5000 g/mol were studied. Chain densities determined in the dry state by ellipsometry were found to be in the range of 0.4-0.7, 0.33-0.58, and 0.12-0.30 chains/nm(2) for MW 750, 2000, and 5000 PEO, respectively. Chain density was found to decrease with increasing molecular weight and to increase as cloud-point conditions were approached. PEO-layer mass densities and chain densities were determined independently by neutron reflectometry. Under low-solubility conditions and for a 4-h chemisorption time, film mass and chain density values of 1.0 +/-0.3 g cm(-3) and 1.8 +/- 0.9 chains/nm(2) were found for MW 750 PEO, and 0.82 +/- 0.02 g cm(-3) and 0.23 +/- 0.07 chains/nm(2) for MW 5000 PEO. Ellipsometry data for these systems yielded graft densities of 0.63 +/- 0.13 and 0.30 +/- 0.02 chains/nm(2), respectively. Using the mass densities obtained from the neutron data in the ellipsometry calculations, chain densities of 0.6 +/- 0.3 and 0.25 +/- 0.02 chains/nm(2), respectively, were obtained for the MW 750 and 5000 films. The ellipsometry and neutron data for the MW 5000 system are thus in agreement within experimental error. In general, the chain-density values are much higher than those corresponding to layers of unperturbed random coil PEO ("mushrooms"), suggesting that the PEO layers are in the brush regime with the chains in an extended conformation.  相似文献   

2.
A clear understanding of the mechanisms responsible for the protein-resistant nature of end-tethered poly(ethylene oxide) (PEO) surfaces remains elusive. A barrier to improved understanding is the fact that many of the factors involved (chain length, chain density, hydration, conformation, and distal chemistry) are inherently correlated. We hypothesize that, by comparing systems of variable but precisely known chain density, it should be possible to gain additional insight into the effects of the other factors. To evaluate this hypothesis, chain-end-thiolated PEOs were chemisorbed to gold-coated silicon wafers such that a range of chain densities was obtained. Three different PEOs were investigated: hydroxy-terminated chains of molecular weight 600 (600-OH), methoxy-terminated chains of molecular weight 750 (750-OCH3), and methoxy-terminated chains of molecular weight 2000 (2000-OCH3). In situ null ellipsometry was used to determine PEO chemisorption kinetics, ultimate PEO chain densities, protein adsorption kinetics, and ultimate protein adsorbed quantities. With this approach, it was possible to ascertain the effects of PEO distal chemistry (-OH, -OCH3), chain length, and layer hydration on protein adsorption. The data obtained suggested that properties related to chain density (conformational freedom, hydration) were the main determinants of protein resistance at chain densities up to a critical value of approximately 0.5 chain/nm2; at this value, protein adsorption was a minimum for the methoxy-terminated PEOs. For the hydroxyl-terminated PEO, adsorption leveled off at the critical value. Thus distal chemistry appears to be a major determinant of protein resistance at chain densities greater than the critical value.  相似文献   

3.
Surfaces based on grafted poly(2-methacryloyloxyethyl phosphorylcholine) (poly(MPC)) "brushes" with a constant graft density of 0.39 chain/nm2 and chain length from 5 to 200 monomer units were prepared by surface-initiated atom transfer radical polymerization (ATRP) on silicon wafers. The chain length and layer thickness of the poly(MPC) grafts were varied via the ratio of MPC to sacrificial initiator. The surfaces were characterized by water contact angle, XPS, and AFM. The effect of poly(MPC) chain length on fibrinogen and lysozyme adsorption was studied in TBS buffer at pH 7.4. The adsorption of both proteins on the poly(MPC)-grafted surfaces was greatly reduced compared to the unmodified silicon. Adsorption decreased with increasing chain length of the poly(MPC) grafts. Grafts of chain length 200 (MW 59 000) gave adsorption levels of 7 and 2 ng/cm2, respectively, for fibrinogen and lysozyme at 1 mg/mL protein concentration, corresponding to reductions of greater than 98% compared to the unmodified silicon. Adsorption experiments using mixtures of the two proteins showed that the suppression of protein adsorption on the poly(MPC)-grafted surfaces was not strongly dependent on protein size or charge.  相似文献   

4.
Polyurethane (PU) was modified using isocyanate chemistry to graft polyethylene oxide (PEO) of various molecular weights (range 300-4600). An antithrombin-heparin (ATH) covalent complex was subsequently attached to the free PEO chain ends, which had been functionalized with N-hydroxysuccinimide (NHS) groups. Surfaces were characterized by water contact angle and X-ray photoelectron spectroscopy (XPS) to confirm the modifications. Adsorption of fibrinogen from buffer was found to decrease by ~80% for the PEO-modified surfaces compared to the unmodified PU. The surfaces with ATH attached to the distal chain end of the grafted PEO were equally protein resistant, and when the data were normalized to the ATH surface density, PEO in the lower MW range showed greater protein resistance. Western blots of proteins eluted from the surfaces after plasma contact confirmed these trends. The uptake of ATH on the PEO-modified surfaces was greatest for the PEO of lower MW (300 and 600), and antithrombin binding from plasma (an indicator of heparin anticoagulant activity) was highest for these same surfaces. The PEO-ATH- and PEO-modified surfaces also showed low platelet adhesion from flowing whole blood. It is concluded that for the PEO-ATH surfaces, PEO in the low MW range, specifically MW 600, may be optimal for achieving an appropriate balance between resistance to nonspecific protein adsorption and the ability to take up ATH and bind antithrombin in subsequent blood contact.  相似文献   

5.
The objective of this work was to gain a better understanding of the mechanism of resistance to protein adsorption of surfaces grafted with poly(ethylene oxide) (PEO). A polyurethane-urea was used as a substrate to which PEO was grafted. Grafting was carried out by introducing isocyanate groups into the surface followed by reaction with amino-terminated PEO. Surfaces grafted with PEO of various chain lengths (PUU-NPEO) were prepared and characterized by water contact angle and X-ray photoelectron spectroscopy (XPS). XPS data indicated higher graft densities on the PUU-NPEO surfaces than on analogous surfaces prepared using hydroxy-PEO (PUU-OPEO) as reported previously [J.G. Archambault, J.L. Brash, Colloids Surf. B: Biointerf. 33 (2004) 111-120]. Protein adsorption experiments using radiolabeled myoglobin, concanavalin A, albumin, fibrinogen and ferritin as single proteins in buffer showed that adsorption was reduced on the PEO-grafted surfaces by up to 95% compared to the control. Adsorption decreased with increasing PEO chain length and reached a minimum at a PEO MW of 2000. Adsorption levels on surfaces with 5000 and 2000 MW grafts were similar. There was no clear effect of protein size on resistance to protein adsorption. Adsorption on the PUU-NPEO surfaces was significantly lower than on the corresponding PUU-OPEO surfaces, again suggesting higher graft densities on the former. Adsorption of fibrinogen from plasma was also greatly reduced on the grafted surfaces. From analysis (SDS-PAGE, immunoblotting) of the proteins eluted after plasma exposure, it was found that the grafted surfaces and the unmodified substrate adsorbed the same proteins in roughly the same proportions, suggesting that adsorption to the PEO surfaces occurs on patches of bare substrate. The PEO grafts did not apparently cause differential access to the substrate based on protein size.  相似文献   

6.
In work reported previously [L.D. Unsworth, H. Sheardown, J.L. Brash, Langmuir 21 (2005) 1036] we investigated protein interactions with polyethylene oxide (PEO) layers formed by chemisorption of thiol-PEO on gold. It was shown that, as a function of surface chain density, protein adsorption passed through a minimum. In follow-on work reported here, neutron reflectometry (NR) was used to investigate the formation and properties (volume fraction and chain density) of such PEO layers in situ, i.e., in contact with water. Chain density was varied by varying solubility conditions (far from and near the cloud point) and chemisorption time. Neutron experiments were carried out using neutrons of de Broglie wavelength 2.37 A. Contrast matching techniques were used to improve sensitivity. Layers formed under high solubility conditions were found to have PEO volume fraction, layer thickness and chain density of 0.33, 28 A, and 0.56 chains/nm2, respectively, after 0.5 h chemisorption; and 0.31, 28.5 A, and 0.59 chains/nm2, respectively, after 11 h, suggesting that the layer is fully formed within 0.5 h. Both chain density and PEO volume fraction in the chemisorbed layers were significantly greater when the layers were formed under low solubility conditions. The PEO layers shown in our previous work to have maximum protein resistance were found to have a PEO volume fraction of approximately 40%. Moreover the limiting volume fraction in the PEO films formed under low solubility conditions was approximately 57%, a value similar to the solubility limit of PEO in aqueous solution, suggesting that local regions in the layers may be phase separated under these conditions. This may result in increased hydrophobicity and may explain why protein adsorption was found to increase on the layers of higher chain density.  相似文献   

7.
Protein adsorption on poly(ethylene oxide) (PEO) and oligo(ethylene oxide) (OEO) monolayers is studied at different packing densities using the Langmuir technique. In the case of a PEO monolayer, a protein adsorption minimum is revealed at sigma(-1) = 10 nm(2) for both lysozyme and fibrinogen. Manifested are two packing density regimes of steric repulsion and compressive attraction between PEO and a protein on top of the overall attraction of the protein to the air/water interface. The observed protein adsorption minimum coincides with the maximum of the surface segment density at sigma(-1) = 10 nm(2). However, OEO monolayer presents a different scenario, namely that the amount of protein adsorbed decreases monotonically with increasing packing density, indicating that the OEO chains merely act as a steric barrier to protein adsorption onto the air/water interface. Besides, in the adsorption of fibrinogen, three distinct kinetic regimes controlled by diffusion, penetration and rearrangement are recognized, whereas only the latter two were made out in the adsorption of lysozyme.  相似文献   

8.
利用放射性碘标记技术研究了血浆蛋白质-缓冲溶液体系在聚苯乙烯-g-聚氧乙烯接枝共聚物表面的等温吸附和吸附动力学。材料表面蛋白质等温吸附量或平衡吸附量随表面PEO含量增加而下降;吸附量最低值小于0.25μg,cm-2;同时探讨了材料表面”梳状“结构对材料表面PEO侧链阻抗蛋白质性能的影响。  相似文献   

9.
The interaction of the proteins bovine serum albumin (BSA), lysozyme (Lys), lactoferrin (Lf), and fibronectin (Fn) with surfaces of protein-resistant poly(ethylene oxide) (PEO) and protein-adsorbing poly(acrylic acid) (PAA) fabricated by plasma-enhanced chemical vapor deposition has been studied with quartz crystal microbalance with dissipation monitoring (QCM-D). We focus on several parameters which are crucial for protein adsorption, i.e., the isoelectric point (pI) of the proteins, the pH of the solution, and the charge density of the sorbent surfaces, with the zeta-potential as a measure for the latter. The measurements reveal adsorption stages characterized by different segments in the plots of the dissipation vs frequency change. PEO remains protein-repellent for BSA, Lys, and Lf at pH 4-8.5, while weak adsorption of Fn was observed. On PAA, different stages of protein adsorption processes could be distinguished under most experimental conditions. BSA, Lys, Lf, and Fn generally exhibit a rapid initial adsorption phase on PAA, often followed by slower processes. The evaluation of the adsorption kinetics also reveals different adsorption stages, whereas the number of these stages does not always correspond to the structurally different phases as revealed by the D- f plots. The results presented here, together with information obtained in previous studies by other groups on the properties of these proteins and their interaction with surfaces, allow us to develop an adsorption scenario for each of these proteins, which takes into account electrostatic protein-surface and protein-protein interaction, but also the pH-dependent properties of the proteins, such as shape and exposure of specific domains.  相似文献   

10.
采用125I放射标记技术研究了血浆白蛋白和纤维蛋白原在聚甲基丙烯酸甲酯-接枝-十八烷基聚氧乙烯(PMMA-g-SPEO)、聚甲基丙烯酸甲酯-接枝-乙基聚氧乙烯(PMMA-g-EPEO)和聚甲基丙烯酸甲酯-甲基丙烯酸十八酯共聚物(PMMA-co-SMA)表面的竞争吸附行为.结果表明,十八烷基聚氧乙烯复合修饰的PMMA-g-SPEO可高选择性地形成白蛋白可逆吸附层,有效地阻抗血小板的粘附,延长材料的凝血时间,是一种理想的白蛋白原位复合的生物医用功能材料.  相似文献   

11.
In this study, the adsorption of amphiphilic poly(ethylene oxide)-block-polylactide (mPEO-PLA) copolymers from a selective solvent onto a polylactide surface was studied as a method of polylactide surface modification and its effect on nonspecific protein adsorption was evaluated. A series of well defined mPEO-PLA copolymers was prepared to investigate the effect of copolymer composition on the resulting PEO chain density and on the surface resistance to protein adsorption. The copolymers contained PEO blocks with molecular weights ranging between 5600 and 23,800 and with 16-47 wt% of PLA. The adsorption of both the copolymers and bovine serum albumin was quantified by attenuated total reflection FTIR spectroscopy (ATR-FTIR). In addition to the adsorbed copolymer amount, its actual composition was determined. The PEO chain density on the surface was found to decrease with the molecular weight of the PEO block and to increase with the molecular weight of the PLA block. The adsorbed copolymers displayed the ability to reduce protein adsorption. The maximum reduction within the tested series (by 80%) was achieved with the copolymer containing PEO of MW 5600 and a PLA block of the same MW.  相似文献   

12.
Interactions between proteins and biomaterial surfaces correlate with many important phenomena in biological systems. Such interactions have been used to develop various artificial biomaterials and applications, in which regulation of non-specific protein adsorption has been achieved with bioinert properties. In this research, we investigated the protein adsorption behavior of polymer brushes of dendrimer self-assembled monolayers (SAMs) with other generations. The surface adsorption properties of proteins with different pI values were examined on gold substrates modified with poly(amidoamine) dendrimer SAMs. The amount of fibrinogen adsorption was greater than that of lysozyme, potentially because of the surface electric charge. However, as the generations increased, protein adsorption decreased regardless of the surface charge, suggesting that protein adsorption was also affected by density of terminal group.  相似文献   

13.
Surfaces coated with poly(ethylene oxide) containing nonionic polymers are of interest in medical applications due to, among other things, the low adsorption of proteins on such surfaces. In this paper we have studied the interfacial properties of surfaces coated with PEO by measuring the forces acting between two such surfaces in water and across a protein solution as well as between one such surface and a surface carrying adsorbed proteins. One type of surface coating was a graft copolymer of poly(ethylene imine) and poly(ethylene oxide) where the cationic poly(ethylene imine) group anchored the polymer to negatively charged mica surfaces. Three different ways to prepare this coating was used and compared. It was found that this coating was not stable in the presence of lysozyme, a small positively charged protein, when the PEO graft density was low. The other type of coating was obtained by adsorbing ethyl(hydroxyethyl)-cellulose onto hydrophobised mica surfaces. The driving force for adsorption is in this case the hydrophobic interaction between nonpolar segments of the polymer and the surface. The EHEC coating was stable in the presence of lysozyme and the interactions between adsorbed layers of lysozyme and EHEC coated surfaces are purely repulsive due to long-range steric forces.  相似文献   

14.
We covalently immobilized poly(ethylene oxide) (PEO) chains onto a fluorinated ethylene propylene copolymer (FEP) surface. On the FEP surface, aldehyde groups were first deposited by plasma polymerization of acetaldehyde or acrolein. Then, amino‐PEO chains were immobilized through Schiff base formation, which was followed by reduction stabilization with sodium cyanoborohydride. The PEO‐grafted polymer surfaces thus prepared were characterized by X‐ray photoelectron spectroscopy (XPS), atomic force microscopy, contact‐angle measurements, and protein adsorption. The dramatic increase in the C O intensity of the high‐resolution XPS C 1s spectrum, together with an overall increase in oxygen content, indicated the successful attachment of PEO chains onto the acetaldehyde plasma surfaces. The amount of grafted PEO chains depended on the superfacial density of the plasma‐generated aldehyde groups. The grafted monoamino‐PEO chains formed a brushlike structure on the polymer surface, whereas the bisamino‐PEO chains predominately adopted a looplike conformation. The PEO surface had a regular morphology with greater roughness than the aldehyde surface underneath. Surface hydrophilicity increased with the grafting of PEO. Also, the bisamino‐PEO‐grafted surface had slightly higher surface hydrophilicity than its monoamino‐PEO counterpart. These PEO coatings reduced fibrinogen adsorption by 43% compared with the substrate FEP surface. © 2000 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 38: 2323–2332, 2000  相似文献   

15.
Solid surfaces are modified by grafting poly(ethylene oxide), PEO, to influence their interaction with indwelling particles, in particular molecules of bovine serum albumin and human plasma proteins. As a rule, the grafted PEO layers suppress protein adsorption. The suppression is most effective when the PEO layer is in a molecular brush conformation having a reciprocal grafting density (area per grafted PEO chain) less than the dimensions of the protein molecules. Nevertheless, the protein molecules may penetrate the PEO brush to some extent. For a given grafting density, the penetration is facilitated by increasing thickness of the brush. Tenuous brushes of reciprocal grafting densities exceeding the protein molecular dimensions enhance protein adsorption. The results point to a weak attractive interaction between PEO and protein. The protein repellency of a densely PEO-brushed surface is ascribed to a high activation energy for the protein molecules to enter the brush. Varying the temperature between 22 and 38 degrees C does not significantly affect the range of grafting density over which the brush changes from protein-attractive to protein-repellent.  相似文献   

16.
A new class of protein-resistant film based on N-substituted glycine derivatives is described. Pulsed plasma deposited poly(N-acryloylsarcosine methyl ester) coatings are shown to be resistant toward the adsorption of fibrinogen and lysozyme. Deposition and UV irradiation of the polymer through a masked grid are found to be effective ways for generating negative and positive image protein arrays, respectively, onto a range of different substrate materials.  相似文献   

17.
Protein adsorption on PDMS surfaces poses a significant challenge in microfluidic devices that come into contact with biofluids such as blood. Polyurethane (PU) is often used for the construction of medical devices, but despite having several attractive properties for biointerfacing, it has not been widely used in microfluidic devices. In this work we developed two new fabrication processes for making thin, transparent and flexible PU-based microfluidic devices. Methods for the fabrication and bonding of microchannels, the integration of fluidic interconnections and surface modification with hydrophilic polyethylene oxide (PEO) to reduce protein adsorption are detailed. Using these processes, microchannels were produced having high transparency (96% that of glass in visible light), high bond strength (326.4 kPa) and low protein adsorption (80% reduction in fibrinogen adsorption vs. unmodified PDMS), which is critical for prevention of fouling. Our findings indicate that PEO modified PU could serve as an effective alternative to PDMS in blood contacting microfluidic applications.  相似文献   

18.
Stable, pendant polyethylene oxide (PEO) layers were formed on medical-grade Pellethane? and Tygon? polyurethane surfaces, by adsorption and gamma-irradiation of PEO-polybutadiene-PEO triblock surfactants. Coated and uncoated polyurethanes were challenged individually or sequentially with nisin (a small polypeptide with antimicrobial activity) and/or fibrinogen, and then analyzed with time-of-flight secondary ion mass spectrometry (TOF-SIMS). Data reduction by robust principal components analysis (PCA) allowed detection of outliers, and distinguished adsorbed nisin and fibrinogen. Fibrinogen-contacted surfaces, with or without nisin, were very similar on uncoated polymer surfaces, consistent with nearly complete displacement or coverage of previously-adsorbed nisin by fibrinogen. In contrast, nisin-loaded PEO layers remained essentially unchanged upon challenge with fibrinogen, suggesting that the adsorbed nisin is stabilized within the pendant PEO layer, while the peptide-loaded PEO layer retains its ability to repel large proteins. Coatings of PEO loaded with therapeutic polypeptides on medical polymers have the potential to be used to produce anti-fouling and biofunctional surfaces for implantable or blood-contacting devices.  相似文献   

19.
Peptide Nucleic Acids (PNAs) linked to high molecular weight (MW) poly(ethylene oxide) (PEO) derivatives could be useful conjugates for the direct functionalisation of gold surfaces dedicated to Surface Plasmon Resonance (SPR)-based DNA sensing. However their use is hampered by the difficulty to obtain them through a convenient and economical route. In this work we compared three synthetic strategies to obtain PNA-high MW PEO conjugates composed of (a) a 15-mer PNA sequence as the probe complementary to genomic DNA of Mycobacterium tuberculosis, (b) a PEO moiety (2 or 5 KDa MW) and (c) a terminal trityl-protected thiol necessary (after acidic deprotection) for grafting to gold surfaces. The 15-mer PNA was obtained by solid-phase synthesis. Its amino terminal group was later condensed to bi-functional PEO derivatives (2 and 5 KDa MW) carrying a Trt-cysteine at one end and a carboxyl group at the other end. The reaction was carried out either in solution, using HATU or PyOxim as coupling agents, or through the solid-phase approach, with 49.6%, 100% and 5.2% yield, respectively. A differential solvent extraction strategy for product purification without the need for chromatography is described. The ability of the 5 KDa PEO conjugate to function as a probe for complementary DNA detection was demonstrated using a Grating-Coupling Surface Plasmon Resonance (GC-SPR) system. The optimized PEO conjugation and purification protocols are economical and simple enough to be reproduced also within laboratories that are not highly equipped for chemical synthesis.  相似文献   

20.
Polyurethanes were modified using monobenzyloxy polyethylene glycol (BPEG) which possesses a bulky hydrophobic benzyloxy group at one end and a hydroxyl group at the other end as a preconstructed BPEG layer, and poly(ethylene glycol) (PEG) and monomethoxyl poly(ethylene glycol) (MPEG) with various chain lengths as fillers. Our objective was to investigate the effect of PEG graft density and conformation on protein adsorption at PEGlated surface. The graft density was estimated by a chemical titration method. The combination of ATR-FTIR, AFM and titration results provide evidences that the graft density can be increased by backfilling PEG or MPEG to a BPEG layer. However, fibrinogen and albumin adsorption significantly increased on all surfaces after PEG or MPEG backfilling. We conclude that the conformation of hydrophobic benzyloxy end groups of the BPEG layer plays a key role. The benzyloxy end groups of preconstructed PEG chains stretch to the surface after PEG backfilling, which possibly accounts for the observed increase in protein adsorption. The BPEG conformation change after backfilling with PEG or MPEG was also suggested by contact angles. Additionally, protein adsorption was slightly influenced by the length of filler, suggesting a change in surface morphology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号