1.
A high-performance liquid chromatographic (HPLC) method for the analysis of coenzyme Q10 (CoQ10) in human seminal plasma was developed and applied to investigate its clinical significance as a reference index relating to oxidative stress and infertile status of spermatozoa. After precipitation of proteins in seminal plasma with methanol, CoQ10 and coenzyme Q9 (CoQ9; internal standard) were extracted with hexane. The supernatant after centrifugation was evaporated to dryness with nitrogen at 45 degrees C. The residue was re-dissolved in isopropanol. HPLC separation of the sample solution was performed on a Lichrospher C(18) column with a mobile phase composed of isopropanol-methanol-tetrahydrofuran in the ratio of 55:39:6 (v/v/v) at a flow rate of 1.0 mL/min. Under the chromatographic conditions described, the CoQ10 and CoQ9 had retention times of approximately 5.83 and 4.97 min, respectively. The peaks were detected at UV 275 nm. Good separation and detectability of CoQ10 in human seminal plasma were obtained. The method was linear in the range 0.01-10.00 microg/mL. The relative standard deviations within- and between-assay for CoQ10 analysis were 0.85 and 1.86%, respectively. The average recoveries were 94.1-99.0% for the human seminal plasma samples. The CoQ10 levels in seminal plasma of 195 patients and 23 control subjects were studied. CoQ10 concentrations in the two populations were: 37.1 +/- 12.2 ng/mL in the fertile group and 48.5 +/- 20.4 ng/mL in the infertile group. The large difference (p < 0.01) between the fertile and infertile populations is evident.  相似文献   

2.
This paper describes validated high-performance column liquid chromatographic (HPLC) and high-performance thin-layer chromatographic (HPTLC) methods for simultaneous estimation of acetylsalicylic acid (ASA) and clopidogrel bisulfate (CLP) in pure powder and formulations. The HPLC separation was achieved on a Nucleosil C8 column (150 mm length x 4.6 mm id, 5 microm particle size) using acetonitrile-phosphate buffer, pH 3.0 (55 + 45, v/v) mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60F254 using ethyl acetate-methanol-toluene-glacial acetic acid (5.0 + 1.0 + 4.0 + 0.1, v/v/v/v) mobile phase. Quantitation was achieved with UV detection at 235 nm over the concentration range 4-24 microg/mL for both drugs, with mean recoveries of 99.98 +/- 0.28 and 100.16 +/- 0.66% for ASA and CLP, respectively, using the HPLC method. Quantitation was achieved with UV detection at 235 nm over the concentration range of 400-1400 ng/spot for both drugs, with mean recoveries of 99.93 +/- 0.55 and 100.21 +/- 0.83% for ASA and CLP, respectively, using the HPTLC method. These methods are simple, precise, and sensitive, and they are applicable for the simultaneous determination of ASA and CLP in pure powder and formulations.  相似文献   

3.
A high-performance liquid chromatography (HPLC) assay was developed for the determination of estazolam in human plasma. Estazolam and alprazolam as an internal standard were detected by ultraviolet absorbance at 240 nm. Estazolam in plasma was extracted by a rapid and simple procedure based on cyanopropyl bonded-phase extraction. Chromatographic separation was achieved with a reversed-phase C8-5 column using a mobile phase of 0.5% potassium dihydrogenphosphate(pH 4.5)-acetonitrile (70:30, v/v). The determination of estazolam was possible in the concentration range of 1.0 - 200.0 ng/mL. The mean recovery of estazolam added to plasma was 96.1 +/- 1.5% with coefficients of variation of less than 5.5%. This method is applicable for accurately monitoring the plasma level of estazolam in healthy subjects participating in scientific research.  相似文献   

4.
Simple, sensitive high-performance liquid chromatography (HPLC) and thin-layer chromatography (TLC) methods are developed for the quantitative estimation of rabeprazole and mosapride in their combined pharmaceutical dosage forms. In HPLC, rabeprazole and mosapride are chromatographed using 0.01M 6.5 pH ammonium acetate buffer-methanol-acetonitrile (40:20:40, v/v, pH 5.70+/-0.02) as the mobile phase at a flow rate of 1.0 mL/min. In TLC, the mobile phase is ethyl acetate-methanol-benzene (2:0.5:2.5, v/v). Both the drugs are scanned at 276 nm. The retention times of rabeprazole and mosapride are found to be 4.93+/-0.01 and 9.79+/-0.02, respectively. The Rf values of rabeprazole and mosapride are found to be 0.42+/-0.02 and 0.61+/-0.02, respectively. The linearities of rabeprazole and mosapride are in the range of 400-2000 ng/mL and 300-1500 ng/mL, respectively, for HPLC; in TLC, the linearities of rabeprazole and mosapride are in the range of 400-1200 ng/spot and 300-900 ng/spot, respectively. The limit of detection is found to be 97.7 ng/mL for rabeprazole and 97.6 ng/mL for mosapride in HPLC; in TLC the limit of detection is found to be 132.29 ng/spot for rabeprazole and 98.25 ng/spot for mosapride. The proposed methods can be applied to the determination of rabeprazole and mosapride in combined pharmaceutical products.  相似文献   

5.
A rapid and specific HPLC method was developed and validated for simultaneous determination of diazepam and its main active metabolites, desmethyldiazepam, oxazepam and temazepam in human plasma. Plasma samples were extracted using toluene. HPLC system included a Chromolith Performance RP-18e 100 mm x 4.6mm column, using 10mM phosphate buffer (pH 2.5)-methanol-acetonitrile (63:10:27, v/v) as mobile phase running at 2 mL min(-1). UV detector (lambda=230 nm) was used. The calibration curves were linear in the concentration range of 2-800 ng mL(-1) for diazepam and 2-200 ng mL(-1) for the three metabolites (r(2)>0.99). The lower limit of quantification was 2 ng mL(-1) for all analytes. Within and between-day precisions in the measurement of QC samples were in the range of 1.8-18.0% for all analytes. The developed procedure was used to assess the pharmacokinetics of diazepam and its main metabolites following single dose administration of 10mg diazepam orally to healthy subjects.  相似文献   

6.
A simple and sensitive high-performance liquid chromatography (HPLC) method has been developed and validated for the determination of DRF-1042, a novel orally active camptothecin (CPT) analog, in human plasma. The sample preparation was a simple deproteinization with acidified methanol yielding almost 100% recovery of DRF-1042. An isocratic reverse-phase HPLC separation was developed on a Supelcosil-LC318 column (250 x 4.6 mm, 5 microm) with mobile phase consisting of 1% v/v triethylamine acetate, pH 5.5 and acetonitrile (80:20, v/v) at a fl ow rate of 1.0 mL/min. The eluate was monitored with a fluorescence detector set at excitation and emission wavelengths of 370 and 430 nm, respectively. The standard curves were linear (r(2) > 0.999) in the concentration ranges 5.0-2004 ng/mL. The lower limit of quantification (LLQ) of the assay was 5 ng/mL. The mean measured quality control (QC) concentrations (range 5 ng/mL to 40 microg/mL) deviated from the nominal concentrations in the range of -10.5-0.08 and -14.5-7.97%, inter- and intra-day, respectively. The inter- and intra-day precisions in the measurement of QC samples at four tested concentrations, were in the range 0.64-5.89% relative standard deviation (RSD) and 0.33-14.7% RSD, respectively. The method was found to be suitable for measurement of plasma concentrations above the calibration curve after serial dilutions. Stability of DRF-1042 was confirmed in a battery of studies, viz., on bench-top, in the auto-sampler, in the stock solutions, after four quick freeze-thaw cycles, up to one month at -20 degree C in human plasma and up to 2 months in the ex vivo samples. The method is simple, sensitive and reliable and has been successfully implemented to investigate the clinical pharmacokinetics of DRF-1042 in cancer patients in a phase I clinical trial.  相似文献   

7.
This paper describes validated high-performance liquid chromatography (HPLC) and high-performance thin-layer chromatography (HPTLC) methods for the simultaneous estimation of pantoprazole (PANT) and domperidone (DOM) in pure powder and capsule formulations. The HPLC separation was achieved on a Phenomenex C18 column (250 mm id, 4.6 mm, 5 pm) using 0.01 M, 6.5 pH ammonium acetate buffer-methanol-acetonitrile (30 + 40 + 30, v/v/v, pH 7.20) as the mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60F254 using ethyl acetate-methanol (60 + 40, v/v) as the mobile phase. Quantification was achieved with ultraviolet (UV) detection at 287 nm over the concentration range 400-4000 and 300-3000 ng/mL with mean recovery of 99.35+/-0.80 and 99.08+/-0.57% for PANT and DOM, respectively (HPLC method). Quantification was achieved with UV detection at 287 nm over the concentration range 80-240 and 60-180 ng/spot with mean recovery of 98.40+/-0.67 and 98.75+/-0.71% for PANT and DOM, respectively (HPTLC method). These methods are simple, precise, and sensitive, and they are applicable for the simultaneous determination of PANT and DOM in pure powder and capsule formulations.  相似文献   

8.
A sensitive HPLC/ESIMS method was established for the determination of manidipine in human plasma and pharmacokinetics study. After basified plasma with ammonia, manidipine and the internal standard (IS) (felodipine) were extracted with n-hexane and separated on a Hypersil ODS2 column with a mobile phase of methanol-5 mm ammonium acetate solution containing 0.1% acetic acid (85:15, v/v). MS determination was performed by electrospray ionization in the selected ion monitoring mode. Manidipine was monitored at m/z 611.4 and IS at m/z 384. The assay had a calibration range from 0.2 to 20 ng/mL and a lower limit of quantification of 0.1 ng/mL. The method has been successfully applied to the pharmacokinetic study in healthy volunteers.  相似文献   

9.
A sensitive, simple, and specific liquid chromatographic method coupled with electrospray ionization-mass spectrometry for the determination of donepezil in plasma is developed, and its pharmacokinetics in healthy, male, Chinese is studied. Using loratadine as the internal standard, after extraction of the alkalized plasma by isopropyl alcohol-n-hexane (3:97, v/v), solutes are separated on a C(18) column with a mobile phase of methanol-acetate buffer (pH 4.0) (80:20, v/v). Detection is performed with a time-of-flight mass spectrometer equipped with an electrospray ionization source operated in the positive-ionization mode. Quantitation of E2020 is accomplished by computing the peak area ratio (donepezil [M+H](+) m/z 380-loratadine [M+H](+) m/z 383) and comparing them with the calibration curve (r = 0.9998). The linear calibration curve is obtained in the concentration range 0.1-15 ng/mL. The limit of quantitation is 0.1 ng/mL. The mean recovery of E2020 from human plasma is 99.4% +/- 6.3% (ranging 93.4-102.6%). The inter- and intraday relative standard deviation is less than 15%. After an oral administration of 5 mg E2020 to 20 healthy Chinese volunteers, the main pharmacokinetic parameters of E2020 are as follow: T(max), 3.10 +/- 0.55 h; t((1/2)), 65.7 +/- 12.8 h; C(max), 10.1 +/- 2.02 ng/mL; MRT, 89.4 +/- 13.4 h; and CL/F, 9.9 +/- 4.3 L/h.  相似文献   

10.
Oxycodone (14-hydroxy-7,8-dihydrocodeinone) is a potent opioid receptor agonist. In the present study, a liquid-liquid extraction-based reversed-phase HPLC method with UV detection was validated and applied for the analysis of oxycodone and its major metabolite, noroxycodone, in human plasma. The analytes were separated using a mobile phase, consisting of acetonitrile and phosphate buffer (8:92, v/v) at a flow rate of 1 mL/min, and UV detection at 205 nm. The retention times for oxycodone, noroxycodone and codein (internal standard) were 14.7, 13.8 and 10.2 min, respectively. The validated quantitation range of the method was 2-100 ng/mL for oxycodone and 10-100 ng/mL for noroxycodone. The developed procedure was applied to assess the pharmacokinetics of oxycodone and its metabolite following administration of a single 20 mg oral dose of oxycodone hydrochloride to one healthy male volunteer.  相似文献   

11.
Simple, sensitive, rapid, and accurate high-performance liquid chromatographic (HPLC) method is developed and validated for the simultaneous determination of diltiazem, metformin, pioglitazone, and rosiglitazone hydrochloride in raw materials, their pharmaceutical formulations, and human serum. In HPLC, all the above drugs were chromatographed using acetonitrile-methanol-water (30:20:50, v/v, pH 2.59 ± 0.02) as the mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The separation is carried out on a Hiber, 250-4.6 RP-18 column, equipped with a UV-vis detector at 230 nm. All the antidiabetic drugs eluted at different retention time and each showed a good resolution from diltiazem. The method is successfully applied to pharmaceutical formulations because no chromatographic interferences from the tablet excipients are found. The method is found to be linear, accurate, and precise with apposite detection and quantification limit. Suitability of the method for the quantitative determination of the drugs is proven by validation in accordance with the requirements laid down by International Conference on Harmonization (ICH) guidelines. The validation results, together with statistical treatment of the data, demonstrated the reliability of this method.  相似文献   

12.
A rapid, simple, and highly sensitive second-derivative synchronous fluorometric method has been developed for the simultaneous analysis of binary mixtures of cinnarizine (CN) and nicergoline (NIC). The method is based upon measurement of the native fluorescence of these drugs at constant wavelength difference (Deltalambda) = 80 nm in aqueous methanol (50%, v/v). The different experimental parameters affecting the native fluorescence of the studied drugs were carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the range of 0.025-1.5 and 0.25-5.5 microg/mL for CN and NIC, respectively, with lower detection limits of 0.58 and 0.82 ng/mL and quantitation limits of 1.93 and 2.73 ng/mL for CN and NIC, respectively. The proposed method was successfully applied for the determination of the studied compounds in synthetic mixtures and in commercial tablets. The results obtained were in good agreement with those obtained with reference methods. The high sensitivity attained by the proposed method allowed the determination of CN in real and spiked human plasma. The mean recovery in the case of spiked human plasma [number of trials (n) = 3] was 102.82 +/- 2.17%, while that in real human plasma (n = 3) was 105.25 +/- 2.05.  相似文献   

13.
An HPLC method was established and validated for the determination of compound FLZ, a synthetic novel anti-Parkinson's disease candidate drug, in rat plasma. FLZ and the internal standard bicyclol were extracted from plasma by solid-phase extraction method and analyzed on a Restek C18 column (4.6 x 250 mm, 5 microm) with a mobile phase consisting of methanol and water (60:40, v/v) at a flow rate of 1.0 mL/min. The detection wavelength was set at 320 nm. The calibration curve was linear within the concentration range from 25 to 500 ng/mL (r2 > 0.999), the limit of quantitation was 25 ng/mL and the average recovery was 92.0% with the RSD less than 5.9%. The relative standard deviation for intra- and inter-day precision was less than 3.8 and 6.9%, respectively. The established HPLC method was validated to be a simple, rapid and reliable procedure and applied to study the preclinical pharmacokinetics of FLZ in rat plasma, and it was the first time that the pharmacokinetics of FLZ had been investigated.  相似文献   

14.
A highly sensitive high-performance liquid chromatographic quantification method with fluorescence detection was developed and validated for the determination of doxazosin in human plasma. The developed method employed one-step extraction of doxazosin from plasma matrix with ethyl acetate using propranolol as an internal standard. Chromatographic separation was obtained within 8.0 min using a reverse-phase Capcell-Pak C(18) column (150 x 4.6 mm i.d., 5 microm) and the mobile phase consisted of methanol-water containing 10 mM perchloric acid and 1.8 mM sodium heptane sulfonic acid (50:50, v/v) and was set at a flow rate of 1.5 mL/min. The calibration curve constructed was linear in the range of 0.3-50.0 ng/mL. The proposed method achieved a lower limit of quantification of 0.3 ng/mL, better than the reported HPLC methods. Average recoveries of doxazosin and the internal standard from human plasma matrix were 87.0 and 85.9%, respectively. The present method was validated by evaluating the precision and accuracy for inter- and intraday variation in the concentration range 0.3-50 ng/mL. The precision values expressed as relative standard deviations in the inter- and intraday validation were 1.17-6.29 and 0.84-5.94%, respectively. This method was successfully applied to the bioequivalence study of two doxazosin controlled release tablets in healthy, male human subjects.  相似文献   

15.
A single LC–MS/MS assay has been developed and validated for the simultaneous determination of metformin and dapagliflozin in human plasma using ion‐pair solid‐phase extraction. Chromatographic separation of the analytes and their internal standards was carried out on a reversed‐phase ACE 5CN (150 × 4.6 mm, 5 μm) column using acetonitrile–15 mm ammonium acetate, pH 4.5 (70:30, v/v) as the mobile phase. To achieve higher sensitivity and selectivity for the analytes, mass spectrometric analysis was performed using a polarity switching approach. Ion transitions studied using multiple reaction monitoring mode were m/z 130.1 [M + H]+/60.1 for metformin and m/z 467.1 [M + CH3COO]?/329.1 for dapagliflozin in the positive and negative modes, respectively. The linear calibration range of the assay was established from 1.00 to 2000 ng/mL for metformin and from 0.10 to 200 ng/mL for dapagliflozin to achieve a better assessment of the pharmacokinetics of the drugs. The limit of detection and limit of quantitation for the analytes were 0.39 and 1.0 ng/mL for metformin and 0.03 and 0.1 ng/mL for dapagliflozin, respectively. There was no interference of plasma matrix obtained from different sources, including hemolyzed and lipemic plasma. The method was successfully applied to study the effect of food on the pharmacokinetics of metformin and dapagliflozin in healthy subjects.  相似文献   

16.
Pucci V  Mandrioli R  Raggi MA 《Electrophoresis》2003,24(12-13):2076-2083
A rapid capillary zone electrophoresis method with indirect UV detection was developed and validated for the determination of valproic acid (VPA) in human plasma. The analyses were carried out under optimized conditions, using a buffer system composed of 15 mM benzoate and 0.5 mM cetyltrimethylammonium bromide at pH 6.0, and 25% v/v methanol; 2-hydroxybutyric acid was selected as the internal standard (IS). The capillary electrophoresis (CE) separation was carried out at a negative potential of 30 kV and the indirect UV detection was operated at 210 +/- 20 nm for all assays. The influence of buffer pH, ionic strength, concentration of electroosmotic flow (EOF) modifier and organic modifier on indirect signal response and migration behavior of the organic acid was investigated. Isolation of VPA from plasma was accomplished by a carefully implemented procedure using methanol as the precipitant agent. Using a high ratio of methanol to plasma for deproteinization (4:1), good absolute recovery of the analyte and satisfactory selectivity was obtained. The calibration line for VPA was linear over the 1-100 microg/mL concentration range. Sensitivity was high; in fact, the limit of detection (LOD) of VPA was 150 ng/mL and 450 ng/mL the limit of quantitation (LOQ). The results obtained analyzing real plasma samples from schizophrenic patients under polytherapy with VPA as well as antipsychotic drugs were satisfactory in terms of precision, accuracy and sensitivity.  相似文献   

17.
To the best of our knowledge, bioanalytical methods to determine rosiglitazone in human plasma reported in literature use internal standards that are not commercially available. Our purpose was to develop a simple method for the determination of rosiglitazone in plasma employing a commercially available internal standard (IS). After the addition of celecoxib (IS), plasma (0.25 mL) samples were extracted into ethyl acetate. The residue after evaporation of the organic layer was dissolved in 750 microL of mobile phase and 50 microL was injected on to HPLC. The separation was achieved using a Hichrom KR 100, 250 x 4.6 mm C(18) with a mobile phase composition potassium dihydrogen phosphate buffer (0.01 m, pH 6.5):acetonitrile:methanol (40:50:10, v/v/v). The flow-rate of the mobile phase was set at 1 mL/min. The column eluate was monitored by fluorescence detector set at an excitation wavelength of 247 nm and emission wavelength of 367 nm. Linear relationships (r(2) > 0.99) were observed between the peak area ratio rosiglitazone to IS vs rosiglitazone concentrations across the concentration range 5-1000 ng/mL. The intra-run precision (%RSD) and accuracy (%Dev) in the measurement of rosiglitazone were <+/-10.69 and <-12.35%, respectively across the QC levels (50-1000 ng/mL). The extraction efficiency was >80% for both rosiglitazone and IS from human plasma. The lower limit of quantitation of the assay was 5 ng/mL. In summary, the methodology for rosiglitazone measurement in plasma was simple, sensitive and employed a commercially available IS.  相似文献   

18.
人血清中地尔硫高效液相色谱法测定及药代动力学参数   总被引:2,自引:0,他引:2  
李克  张昕  袁倚盛  罗楠  谭力 《色谱》1997,15(5):451-453
 建立了反相高效液相色谱法监测人口服地尔硫艹卓缓释片后血药浓度。血样用正己烷-氯仿-异丙醇混合溶剂(60405)提取后,以C18化学键合硅胶为固定相,甲醇-水-三乙胺为流动相,安定为内标,在239nm波长处定量检测。血药浓度在15~300μg/L范围内线性关系良好,最低检测浓度为3μg/L。批内(n=7)及批间(n=5)测定相对标准偏差分别小于6.8%和8.4%,回收率为91%~104%。监测了8名健康人口服盐酸地尔硫艹卓缓释片后的不同时间的血药浓度变化,计算了有关的药代动力学参数。  相似文献   

19.
A sensitive enantioselective high-performance liquid chromatography (HPLC) method was developed and validated to determine S-(+)- and R-(-)-arotinolol in human plasma. Baseline resolution was achieved by using teicoplanin macrocyclic antibiotic chiral stationary phase (CSP) known as Chirobiotic T with a polar organic mobile phase consisting of methanol:glacial acetic acid:triethylamine, 100:0.1:0.1, (v/v/v) at a fl ow rate of 0.8 mL/min and UV detection set at 317 nm. Human plasma was spiked with stock solution of arotinolol enantiomers and labetalol as the internal standard. The assay involved the use of liquid-liquid extraction procedure with ethyl ether under alkaline condition for human plasma sample prior to HPLC analysis. Recoveries for S-(+)- and R-(-)-arotinolol enantiomers were in the range 93-103% at 200-1400 ng/mL level. Intra-day and inter-day precision calculated as %RSD was in the ranges 1.3-3.4 and 1.9-4.5% for both enantiomers, respectively. Intra-day and inter-day accuracies calculated as percentage error were in the ranges 1.2-3.5 and 1.5-6.2% for both enantiomers, respectively. Linear calibration curves in the concentration range 100-1500 ng/mL for each enantiomer showed a correlation coefficient (r) of 0.9998. The limit of quantitation (LOQ) and limit of detection (LOD) for each enantiomer in human plasma were 100 and 50 ng/mL (S/N = 3), respectively.  相似文献   

20.
As a prerequisite to the determination of pharmacokinetic parameters of icariin in rats, an HPLC method using UV detection was developed and validated. Icariin and the internal standard, quercetin, were extracted from plasma samples using ethyl acetate after acidification with 0.05 mol/L NaH2PO4 solution (pH 5.0). Chromatographic separation was achieved on an Agilent XDB Cls column (250 x 4.6 mm id, 5 microm) equipped with a Shim-pack GVP-ODS C18 guard column (10 x 4.6 mm id, 5 microm) using a mobile phase of ACN/water/acetic acid (31:69:0.4 v/v/v) at a flow rate of 1.0 mL/ min. Detection was at 277 nm. The calibration curve was linear from 0.05 to 100.0 microg/mL with 0.05 microg/mL as the lower LOQ (LLOQ) in plasma. The intra- and interday precisions in terms of RSD were lower than 5.7 and 7.8% in rat plasma, respectively. The accuracy in terms of relative error (RE) ranged from -1.6 to 3.2%. The extraction recoveries of icariin and quercetin were 87.6 and 80.1%, respectively. The main pharmacokinetic parameters for rats were determined after a single intravenous administration of 10 mg/kg icariin: t1/2, 0.562 +/- 0.200 h; AUC0-infinity, 8.73 +/- 2.23 microg x h/mL; CLToT, 20.10 +/- 5.80 L/kg x h; Vz, 1.037 +/- 0.631 L/kg; MRT0-infinity, 0.134 +/- 0.040 h; and Vss, 0.170 +/- 0.097 L/kg.  相似文献   