首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A review of recent results on stand-off Laser-Induced Breakdown Spectroscopy (LIBS) analysis and applications is presented. Stand-off LIBS was suggested for elemental analysis of materials located in environments where any physical access was not possible but optical access could be envisaged. This review only refers to the use of the open-path LIBS configuration in which the laser beam and the returning plasma light are transmitted through the atmosphere. It does not present the results obtained with a transportation of the laser pulses to the target through an optical fiber. Open-path stand-off LIBS has mainly been used with nanosecond laser pulses for solid sample analysis at distances of tens of meters. Liquid samples have also been analyzed at distances of a few meters. The distances achievable depend on many parameters including the laser characteristics (pulse energy and power, beam divergence, spatial profile) and the optical system used to focus the pulses at a distance. A large variety of laser focusing systems have been employed for stand-off analysis comprising refracting or reflecting telescope. Efficient collection of the plasma light is also needed to obtain analytically useful signals. For stand-off LIBS analysis, a lens or a mirror is required to increase the solid angle over which the plasma light can be collected. The light collection device can be either at an angle from the laser beam path or collinear with the optical axis of the system used to focus the laser pulses on the target surface. These different configurations have been used depending on the application such as rapid sorting of metal samples, identification of material in nuclear industry, process control and monitoring in metallurgical industry, applications in future planetary missions, detection of environmental contamination or cleaning of objects of cultural heritage. Recent stand-off analyses of metal samples have been reported using femtosecond laser pulses to extend LIBS capabilities to very long distances. The high-power densities achievable with these laser pulses can also induce self-guided filaments in the atmosphere which produce LIBS excitation of a sample. The first results obtained with remote filament-induced breakdown spectroscopy predict sample analysis at kilometer ranges.  相似文献   

2.
激光诱导击穿光谱(Laser-induced breakdown spectroscopy, LIBS)技术利用激光实现对分析样品的快速原位剥蚀和光谱激发,是一种具有广阔应用前景的分析手段,尤其是在现场、原位分析中优势明显,快速原位的分析特点符合未来分析仪器的发展方向.近年来基于该技术开展各类仪器研发的相关工作,引起广大研究者的极大关注.本文综述了激光诱导击穿光谱仪器中关键部件的组成及发展,从便携式、手持式及远程系统三个方面综述了各类现场应用仪器的研发进展,并对未来发展方向进行了展望.  相似文献   

3.
因高温、辐射等极端环境限制,核领域亟需具备在线快速检测特性的分析仪器。基于小型风冷脉冲激光器与小型光纤光谱仪实现了远程激光诱导击穿光谱技术(LIBS)装置的小型化,对该便携式远程LIBS系统的定量分析性能进行了研究,实现了5 m外样品的元素遥测。在单脉冲激光能量100 mJ,脉冲延时1.0 μs的分析条件下,实现了白水晶、陶瓷及铝合金样品中Mn、Si、Al、Na、Ba、Ca及Cr元素的激发,验证了LIBS技术对材料组分和物料成分的远程探测能力,对铝合金样品的定量分析结果显示,该远程遥测系统对铝合金样品定量测量结果的最大相对平均偏差为12%,具备执行核领域快速分析场景下的半定量检测能力。  相似文献   

4.
A field-deployable laser-induced breakdown spectrometer for measurements in the hundreds of meters range has been presented. The system is capable of elemental analysis with no previous preparation and in near real time, with the only requirement of a free line-of-sight between the instrument and the sample. Main factors influencing LIBS performance at stand-off distances are outlined. LIBS signal is shown to depend on range of analysis, peak power, beam quality, laser wavelength and optics dimensions. A careful control of focusing conditions has been shown to be of importance to avoid interferences from air breakdown by the stand-off focused beam.  相似文献   

5.
Recently, there has been an increasing interest in the laser-induced breakdown spectroscopy (LIBS) technique for stand-off detection of geological samples for use on landers and rovers to Mars, and for other space applications. For space missions, LIBS analysis capabilities must be investigated and instrumental development is required to take into account constraints such as size, weight, power and the effect of environmental atmosphere (pressure and ambient gas) on flight instrument performance. In this paper, we study the in-situ LIBS method at reduced pressure (7 Torr CO2 to simulate the Martian atmosphere) and near vacuum (50 mTorr in air to begin to simulate the Moon or asteroids' pressure) as well as at atmospheric pressure in air (for Earth conditions and comparison). Here in-situ corresponds to distances on the order of 150 mm in contrast to stand-off analysis at distance of many meters. We show the influence of the ambient pressure on the calibration curves prepared from certified soil and clay pellets. In order to detect simultaneously all the elements commonly observed in terrestrial soils, we used an Echelle spectrograph. The results are discussed in terms of calibration curves, measurement precision, plasma light collection system efficiency and matrix effects.  相似文献   

6.
Laser-induced Breakdown Spectroscopy (LIBS) is actively under development for future use on surface probes to Mars. The analytical method can be deployed for in-situ and/or stand-off analysis with the latter embodiment providing the greatest advantages compared to previous and current elemental analysis methods used for planetary surface analysis. For this application, LIBS must be thoroughly investigated in terms of analytical capabilities and flight-rated instruments must be developed. Because of the low pressure of the predominantly CO2 atmosphere on Mars, studies are needed to understand analytical requirements and to determine performance under these conditions. Stand-off analysis demands the most stringent requirements on instrumentation. Therefore, it must be determined if the high performance components that are normally used in a typical LIBS laboratory setup, which are generally not optimized for small size and weight, are essential to obtain the maximum scientific return from a mission. A key component of a LIBS apparatus is the detection system consisting of a spectrograph and a detector. Here we present an evaluation of one design of a compact spectrograph (Ocean Optics HR2000) for in-situ and stand-off LIBS analyses of geological samples under Mars atmospheric conditions.  相似文献   

7.
As applications for laser-induced breakdown spectroscopy (LIBS) become more varied with a greater number of field and industrial LIBS systems developed and as the technique evolves to be more quantitative that qualitative, there is a more significant need for LIBS systems capable of analysis with the use of a single laser shot. In single-shot LIBS, a single laser pulse is used to form a single plasma for spectral analysis. In typical LIBS measurements, multiple laser pulses are formed and collected and an ensemble-averaged method is applied to the spectra. For some applications there is a need for rapid chemical analysis and/or non-destructive measurements; therefore, LIBS is performed using a single laser shot. This article reviews in brief several applications that demonstrate the applicability and need for single-shot LIBS.  相似文献   

8.
In the present work we are studying the influence of pulse duration (nanosecond (ns) and femtosecond (fs)) at λ = 248 nm on the laser-induced plasma parameters and the quantitative analysis results for elements such as Sn, Zn and Pb, in different types of bronze alloys adopting LIBS in ambient atmosphere. Binary (Sn–Cu), ternary (Sn–Zn–Cu or Sn–Pb–Cu) and quaternary (Sn–Zn–Pb–Cu) reference alloys characterized by a chemical composition and metallurgical features similar to those used in Roman times, were employed in the study. Calibration curves, featuring linear regression coefficients over 98%, were obtained for tin, lead and zinc, the minor elements in the bronze alloys (using the internal standardization method) as well as for copper, the major element. The effects of laser pulse duration and energy on laser-induced plasma parameters, namely the excitation temperature and the electron density have been studied in our effort to optimize the analysis. Finally, LIBS analysis was carried on three real metal objects and the spectra obtained have been used to estimate the type and elemental composition of the alloys based on the calibration curves produced with the reference alloys. The results obtained are very useful in the future use of portable LIBS systems for in situ qualitative and quantitative elemental analysis of bronze artifacts in museums and archaeological sites.  相似文献   

9.
We report on our ongoing studies to develop Laser-Induced Breakdown Spectroscopy (LIBS) for planetary surface missions to Mars and other planets and moons, like Jupiter's moon Europa or the Earth's moon. Since instruments for space missions are severely mass restricted, we are developing a light-weight miniaturized close-up LIBS instrument to be installed on a lander or rover for the in-situ geochemical analysis of planetary surface rocks and coarse fines. The total mass of the instrument will be ≈ 1 kg in flight configuration. Here we report on a systematic performance study of a LIBS instrument equipped with a prototype laser of 216 g total mass and an energy of 1.8 mJ. The LIBS measurements with the prototype laser and the comparative measurements with a regular 40 mJ laboratory laser were both performed under Martian atmospheric conditions.  相似文献   

10.
Laser Induced Breakdown Spectroscopy (LIBS) is an advanced analytical technique for elemental determination based on direct measurement of optical emission of excited species on a laser induced plasma. In the realm of elemental analysis, LIBS has great potential to accomplish direct analysis independently of physical sample state (solid, liquid or gas). Presently, LIBS has been easily employed for qualitative analysis, nevertheless, in order to perform quantitative analysis, some effort is still required since calibration represents a difficult issue. Artificial neural network (ANN) is a machine learning paradigm inspired on biological nervous systems. Recently, ANNs have been used in many applications and its classification and prediction capabilities are especially useful for spectral analysis. In this paper an ANN was used as calibration strategy for LIBS, aiming Cu determination in soil samples. Spectra of 59 samples from a heterogenic set of reference soil samples and their respective Cu concentration were used for calibration and validation. Simple linear regression (SLR) and wrapper approach were the two strategies employed to select a set of wavelengths for ANN learning. Cross validation was applied, following ANN training, for verification of prediction accuracy. The ANN showed good efficiency for Cu predictions although the features of portable instrumentation employed. The proposed method presented a limit of detection (LOD) of 2.3 mg dm− 3 of Cu and a mean squared error (MSE) of 0.5 for the predictions.  相似文献   

11.
The Army Research Office of the Army Research Laboratory recently sponsored the development of a commercial laser-induced breakdown spectroscopy (LIBS) chemical sensor that is sufficiently compact and robust for use in the field. This portable unit was developed primarily for the rapid, non-destructive detection of lead (Pb) in soils and in paint. In order to better characterize the portable system, a comparative study was undertaken in which the performance of the portable system was compared with a laboratory LIBS system at the Army Research Laboratory that employs a much more sophisticated laser and detector. The particular focus of this study was to determine the effects on the performance of the field sensor's lower spectral resolution, lack of detector gating, and the multiple laser pulsing that occurs when using a passively Q-switched laser. Surprisingly, both the laboratory and portable LIBS systems exhibited similar performance with regards to detection of Pb in both soils and in paint over the 0.05–1% concentration levels. This implies that for samples similar to those studied here, high-temporal resolution time gating of the detector is not necessary for quantitative analysis by LIBS. It was also observed that the multiple pulsing of the laser did not have a significant positive or negative effect on the measurement of Pb concentrations. The alternative of using other Pb lines besides the strong 406-nm line was also investigated. No other Pb line was superior in strength to the 406-nm line for the latex paint and the type of soils used in the study, although the emission line at 220 nm in the UV portion of the spectrum holds potential for avoiding elemental interferences. These results are very encouraging for the development of lightweight, portable LIBS sensors that use less expensive and less sophisticated laser and detector components. The portable LIBS system was also field tested successfully at sites of documented Pb contamination on military installations in California and Colorado.  相似文献   

12.
We present LIBS experimental results that demonstrate the use of a newly developed, compact, versatile pulsed laser source in material analysis related to art and archaeological applications in view of research aiming at the development of portable LIBS instrumentation. LIBS qualitative analysis measurements were performed on various samples and objects, and the spectra were recorded in gated and non-gated modes. The latter is important because of advantages arising from size and cost reduction when using simple, compact spectrograph-CCD detection systems over the standard ICCD-based configurations.  相似文献   

13.
The potentials of two advanced laser-induced breakdown spectroscopy (LIBS) techniques which are used to determine the total carbon content in soils have been examined. The first one is the combination of a single-pulse laser ablation with spark excitation of plasma plume triggering the gap between electrodes close to the target surface. The second one is a more conventional double-pulse LIBS. In both modes the calibration graphs have a nonlinear trend in the actual range of carbon contents and present a good R2 value (0.97). In the combined laser-spark approach, using low-cost and portable laser instrumentation is possible, as well as inducing a micro-damage on the target surface. Certain regularities in the spectral line intensities of soil nutritious elements have been detected and appear to be connected to the total carbon content and to the soil origin.  相似文献   

14.
Laser-induced breakdown spectroscopy (LIBS) has been used in the elemental analysis for a variety of environmental samples and as a proof of concept for a host of forensic applications. In the first application, LIBS was used for the rapid detection of carbon from a number of different soil types. In this application, a major breakthrough was achieved by using a multivariate analytical approach that has brought us closer towards a “universal calibration curve”. In a second application, it has been demonstrated that LIBS in combination with multivariate analysis can be employed to analyze the chemical composition of annual tree growth rings and correlate them to external parameters such as changes in climate, forest fires, and disturbances involving human activity. The objectives of using this technology in fire scar determinations are: 1) To determine the characteristic spectra of wood exposed to forest fires and 2) To examine the viability of this technique for detecting fire occurrences in stems that did not develop fire scars. These examples demonstrate that LIBS-based techniques are inherently well suited for diverse environmental applications. LIBS was also applied to a variety of proof of concept forensic applications such as the analysis of cremains (human cremation remains) and elemental composition analysis of prosthetic implants.  相似文献   

15.
We report our initial efforts to use a small portable Raman system for stand-off detection and identification of various types of organic chemicals including benzene, toluene, ethyl benzene and xylenes (BTEX). Both fiber-optic (FO) coupled and a directly coupled f/2.2 spectrograph with the telescope have been developed and tested. A frequency-doubled Nd:YAG pulsed laser (20 Hz, 532 nm, 35 mJ/pulse) is used as the excitation source. The operational range of the FO coupled Raman system was tested to 66 m, and the directly coupled system was tested to a distance of 120 m. We have also measured remote Raman spectra of compressed methane gas and methane gas hydrate. The usefulness of the remote Raman system for identifying unknown compounds is demonstrated by measuring stand-off spectra of two plastic explosives, e.g. tri-amino tri-nitrobenzene (TATB) and beta-HMX at 10 m stand-off distance. The remote Raman system will be useful for terrestrial applications such as monitoring environmental pollution, in identifying unknown materials in public places in 10s or less, and for detecting hydrocarbon plumes and gas hydrates on planetary surfaces such as Mars.  相似文献   

16.
Several elements important to planetary geology (e.g. Br, C, Cl, P, S) and the human exploration of Mars (e.g. toxic elements such as As) have strong emission lines in the purge and vacuum ultraviolet (VUV) spectral region (100–200 nm). This spectral region has not been extensively studied for space applications using geological samples. We studied emissions from the laser-induced breakdown spectroscopy (LIBS) plasma in this region using a sample chamber filled with 7 torr (930 Pa) of CO2 to simulate the Martian atmosphere. Pressures down to 0.02 torr were also used to evaluate the effect of the residual CO2 on the spectra and to begin investigating the use of VUV-LIBS for airless bodies such as asteroids and the Moon. Spectra were recorded using a 0.3-m vacuum spectrometer with an intensified CCD (ICCD) camera. The effects of time delay and laser energy on LIBS detection at reduced pressure were examined. The effect of ambient CO2 on the detection of C in soil was also evaluated. Lines useful for the spectrochemical analysis of As, Br, C, Cl, P, and S were determined and calibration curves were prepared for these elements. Although LIBS is being developed for stand-off analysis at many meters distance, the experiments reported here were aimed at in-situ (close-up) analysis.  相似文献   

17.
LIBS did not appear de novo in 1962, but was built upon accomplishments of the past. These started with very old concepts of indivisible units (atomos), chemical and physical experiments and theoretical advances that took place in the late 19th and early 20th centuries, the development of the laser, the discovery of gas breakdown, and the realization of the application to spectrochemistry. We sketch the historical developments and focus as well on the advances in LIBS methodology and instrumentation over the past 50 years, culminating with a synopsis of the LIBS 2012 Conference in Luxor, Egypt.  相似文献   

18.
An international consortium is studying the feasibility of performing in situ geochemical analysis of Mars soils and rocks at stand-off distances up to several meters using the Laser-Induced Breakdown Spectroscopy (LIBS) technique. Stand-off analysis for Martian exploration imposes particular requirements on instrumentation, and it is necessary to first test the performance of such a system in the laboratory. In this paper, we test the capabilities of two different experimental setups. The first one is dedicated to the qualitative analysis of metals and rocks at distances between 3 and 12 m. With the second one, we have obtained quantitative results for aluminum alloys and developed a spectral database under Martian conditions for sulfur and chlorine, two elements that are geologically interesting but generally difficult to detect by LIBS under standard conditions (atmospheric pressure, close distance). These studies were carried out to determine an optimal instrumental design for in situ Mars analysis. The quality of analytical results affected by the optical elements and spectrometer has been particularly highlighted.  相似文献   

19.
In this review we discuss the application of laser-induced breakdown spectroscopy (LIBS) to the problem of detection of residues of explosives. Research in this area presented in open literature is reviewed. Both laboratory and field-tested standoff LIBS instruments have been used to detect explosive materials. Recent advances in instrumentation and data analysis techniques are discussed, including the use of double-pulse LIBS to reduce air entrainment in the analytical plasma and the application of advanced chemometric techniques such as partial least-squares discriminant analysis to discriminate between residues of explosives and non-explosives on various surfaces. A number of challenges associated with detection of explosives residues using LIBS have been identified, along with their possible solutions. Several groups have investigated methods for improving the sensitivity and selectivity of LIBS for detection of explosives, including the use of femtosecond-pulse lasers, supplemental enhancement of the laser-induced plasma emission, and complementary orthogonal techniques. Despite the associated challenges, researchers have demonstrated the tremendous potential of LIBS for real-time detection of explosives residues at standoff distances. Figure This review discusses the application of laser-induced breakdown spectroscopy (LIBS) to the problem of explosive residue detection. LIBS offers the capability for real-time, standoff detection of trace amounts of residue explosives on various surfaces  相似文献   

20.
A method based on laser induced breakdown spectroscopy (LIBS) and neural networks (NNs) has been developed and applied to the identification and discrimination of specific bacteria strains (Pseudomonas aeroginosa, Escherichia coli and Salmonella typhimurium). Instant identification of the samples is achieved using a spectral library, which was obtained by analysis using a single laser pulse of representative samples and treatment by neural networks. The samples used in this study were divided into three groups, which were prepared on three different days. The results obtained allow the identification of the bacteria tested with a certainty of over 95%, and show that only a difference between the bacteria can cause identification. Single-shot measurements were sufficient for clear identification of the bacterial strains studied. The method can be developed for automatic real time, fast, reliable and robust measurements and can be packaged in portable systems for non-specialist users.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号