首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and specific double-antibody enzyme immunoassay (EIA) for a substance P (SP)-like immunoreactive substance (SP-IS) was developed. For competitive reactions, the SP-antibody was incubated with SP standard (or sample) and beta-D-galactosidase labeled Tyr8-SP (delayed addition). Free and antibody-bound enzyme hapten were separated by using an anti-rabbit immunoglobulin G coated immunoplate. Activity of the enzyme on the plate was fluorometrically determined. The present immunoassay allows detection of 0.4 to 10 fmol/well of SP. Using the present EIA, SP-ISs in human saliva and plasma were determined. The level of SP-IS in human saliva was about 7 pmol/l, which was almost three times higher than that in human plasma.  相似文献   

2.
3.
4.
5.
A highly selective high-performance liquid chromatographic-radioimmunoassay method for the measurement of individual endogenous angiotensin peptides in human plasma is described. This method allows the complete resolution of the immunoreactive angiotensin II peptides. We have also measured the angiotensin peptide levels and compared them in both pooled and individual human plasma. The effects of inhibition of angiotensin-converting enzyme on the angiotensin peptide levels have also been observed in a patient with renovascular hypertension with the plasma angiotensin II level being reduced greater than seven-fold. This new methodology was validated by recovery experiments in plasma over a range of physiological levels using two methods of detection, radioimmunoassay and liquid scintillation counting. Consistent recoveries near 80% have been achieved for each peptide in plasma at concentrations over a physiological range. The described method enables the direct measurement of the circulating angiotensin peptides and the elucidation of their specific roles in physiological and disease states.  相似文献   

6.
We established a highly sensitive and specific double-antibody enzyme linked immunosorbent assay for beta-endorphin (beta-EP). For competitive reactions, the beta-EP-antibody was incubated with beta-EP standard (or sample) and beta-D-galactosidase-labeled beta-EP (delayed addition). Free and antibody-bound labeled antigen were separated by using an anti-rabbit immunoglobulin G coated immunoplate. The enzyme activity on the plate was fluorometrically determined. The minimal detection limit was approximately 0.4fmol/well (10 pmol/l). Using this assay system, beta-EP-like immunoreactivity (-LI) in human plasma was determined. The level of beta-EP-LI in extracted human plasma from 6 normal subjects was 2.44 +/- 0.68 pmol/l. High performance liquid chromatography analysis of the plasma of a normal subject revealed a single immunoreactive form which eluted with the same retention time as that of synthetic beta-EP.  相似文献   

7.
8.
Angiotensin-(1-8)octapeptide (angiotensin II) is the active principle of the renin-angiotensin system. Crossreaction of angiotensin II-antisera with inactive precursors and metabolic fragments prevented the specific quantitation of this hormone in biological fluids. Peptide-extraction on bonded-phase silica followed by peptide-separation using isocratic reverse-phase high performance liquid chromatography and subsequent radioimmunoassay rendered possible the octapeptide-specific measurement of angiotensin II in 2 ml plasma with a detection limit of 0.4 fmol/ml. The coefficient of variation for intra-assay precision was 0.06 and for inter-assay precision 0.13. 125I-angiotensin II was recovered from plasma by solid-phase extraction to 99 +/- 2% (mean +/- S.D.). The overall recovery of 5, 10 and 20 fmol unlabeled angiotensin II added to plasma was 80 +/- 10%. Plasma concentrations in supine normal humans averaged 4.1 +/- 1.6 fmol/ml and were suppressed below the detection limit by angiotensin I converting enzyme inhibition.  相似文献   

9.
10.
A heterogeneous fluorescence immunoassay for angiotensin I is described. Fluorescein isothiocyanate (FITC) is used as fluorescent label; it is covalently linked to angiotensin I by reacting in pH 9.2 carbonate buffer at 18°C for 24 h. A Sephadex G-10 gel filtration column permits separation of conjugate from excess of FITC. The assay is applied to 4–40 ng ml?1 angiotensin I, with a relative standard deviation of 5%.  相似文献   

11.
12.
13.
We have developed a competitive enzyme immunoassay for a drug, which was a newly synthesized anti-ulcer agent, using an enzyme immunoassay. The polyclonal anti-drug antibody coupled to biotin, peroxidase labeled drug derivatives as a tracer, and a small column of Sepharose 4B covalently bound to avidin were used in the assay. This assay is simple and rapid, and the sensitivity and the measuring range can be controlled by the flow rate of the substrate solution. The correlation between serum drug concentrations (0.1-10 micrograms/ml) measured by gas chromatography and this assay was good (r = 0.991). This principle for the assay is very practical and applicable to the enzyme immunoassay for small and large molecules.  相似文献   

14.
15.
16.
New highly sensitive enzyme immunoassay (EIA) has been developed and validated for the determination of pravastatin (PRV) in human plasma samples. PRV was coupled to keyhole limpt hemocyanin (KLH) and bovine serum albumin (BSA) via its terminal carboxylic acid group by carbodiimide reagent. PRV-KLH conjugate was used as an immunogen for raising anti-PRV polyclonal antibody in rabbits. The generated anti-PRV antibody recognized PRV with high affinity and selectivity. PRV-BSA conjugate was immobilized onto microwell plates and used as a solid phase. The assay involved a competitive binding reaction between PRV, in plasma sample, and the immobilized PRV-BSA for the binding sites on a limited amount of the anti-PRV antibody. The anti-PRV antibody bound to the plate wells was quantified with horseradish peroxidase-labeled anti-immunoglobulin second anti-rabbit IgG antibody and 3,3′,5,5′-tetramethylbenzidine as a substrate for the peroxidase enzyme. The concentration of PRV in the sample was quantified by its ability to inhibit the binding of the anti-PRV antibody to the immobilized PRV-BSA and subsequently the color development in the assay wells. The conditions of the proposed EIA were investigated and the optimum conditions were employed in the determination of PRV in plasma samples. The assay limit of detection was 0.2 ng mL−1 and the effective working range at relative standard deviation (RSD) of ≤5% was 0.5-20 ng mL−1. The mean analytical recovery of PRV from spiked plasma was 100.9 ± 2.98%. The precision of the assay was satisfactory; RSD was 2.61-3.70 and 3.96-4.17% for intra- and inter-assay precision, respectively. The analytical procedure is convenient, and one can analyze ∼200 samples per working day, facilitating the processing of large-number batch of samples. The proposed EIA has a great value in the routine analysis of PRV in plasma samples for its therapeutic monitoring and pharmacokinetic studies.  相似文献   

17.
18.
A selective, accurate and precise high-performance liquid chromatographic assay coupled to fluorescence detection was developed for the detection of some angiotensin II receptor antagonists (ARA II): Losartan, Irbesartan, Valsartan, Candesartan cilexetil and its metabolite Candesartan MI. The analytes and the internal standard (bumetanide, a high-ceiling diuretic) were extracted from plasma under acidic conditions by means of solid-phase extraction using C8 cartridges. This procedure allowed recoveries close to 80% for all these drugs excluding Candesartan cilexetil (70%) which presented adsorption processes on glass and plastic walls. The analytes and potential interferences were separated on a reversed-phase column, muBondapak C18, at room temperature. A gradient elution mode was used to carry out the separation, the optimal mobile phase being composed of acetonitrile-5 mM acetate buffer, pH 4, at variable flow-rates (from 1.0 to 1.2 ml/min). Fluorescence detector was set at an excitation wavelength of 250 nm and an emission wavelength of 375 nm. Intra- and inter-day relative standard deviations for all the compounds were lower than 8% except for Losartan (12%) and the method assesses a quite good accuracy (percentage of relative error approximately 6% in most of the cases). The limit of quantitation for these compounds was 3 ng/ml for Candesartan cilexetil and M1, 16 ng/ml for Losartan and 50 ng/ml for Irbesartan and Valsartan, which allows their determination at expected plasma concentration levels. This assay method has been successfully applied to plasma samples obtained from hypertensive patients under clinical studies after oral administration of a therapeutic dose of some of these ARA II compounds.  相似文献   

19.
An enzyme immunoassay based on the use of crossed-beam thermal lens detection is described. In this assay, poly-N-isopropylacrylamide, a water-soluble, thermally precipitating synthetic polymer, was used as a carrier to minimize non-specific binding. The enzyme substrate of the horseradish peroxidase that was employed was 3,3′,5,5′-tetramethylbenzidine. The color development of the enzyme–substrate reaction was stopped by SDS and Na2SO3 to achieve a stable blue solution. The background reduction and stabilization made it possible to use a crossed-beam thermal lens technique as the measurement method. This method was demonstrated to be applicable by determination of hepatitis B surface antigen in human serum. A detection limit of 0.15 ng/ml was obtained. This was more sensitive than that of the commercially available ELISA method.  相似文献   

20.
A sensitive and specific double-antibody enzyme immunoassay (EIA) for a thyrotropin releasing hormone (TRH)-like immunoreactive substance has been developed. In order to synthesize TRH-labeled beta-D-galactosidase (beta-gal), a newly devised TRH derivative, pGlu-His-Pro-NH-(CH2)6-NH2 (TRH-Hex), was employed. TRH-Hex was linked to beta-gal by the N-(epsilon-maleimidocaproyloxy) succinimide coupling procedure. For competitive reactions, the TRH antibody was incubated with standard TRH and TRH-Hex-beta-gal (delayed addition). Free and antibody-bound enzyme hapten were separated by using an anti-rabbit immunoglobulin G coated immunoplate. Activity of the enzyme on the plate was fluorometrically determined. The present immunoassay allows detection of 0.8 to 100 pmol/well of TRH.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号