首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Yeh AT  Nassif N  Zoumi A  Tromberg BJ 《Optics letters》2002,27(23):2082-2084
A multiphoton microscope employing second-harmonic generation (SHG) and two-photon excited fluorescence (TPF) is used for high-resolution ex vivo imaging of rabbit cornea in a backscattering geometry. Endogenous TPF and SHG signals from corneal cells and extracellular matrix, respectively, are clearly visible without exogenous dyes. Spectral characterization of these upconverted signals provides confirmation of the structural origin of both TPF and SHG, and spectral imaging facilitates the separation of keratocyte and epithelial cells from the collagen-rich corneal stroma. The polarization dependence of collagen SHG is used to highlight fiber orientation, and three-dimensional SHG tomography reveals that approximately 88% of the stromal volume is occupied by collagen lamellae.  相似文献   

2.
We demonstrate that simultaneous second-harmonic generation (SHG) and two-photon-excited fluorescence (TPEF) can be used to rapidly image biological membranes labeled with a styryl dye. The SHG power is made compatible with the TPEF power by use of near-resonance excitation, in accord with a model based on the theory of phased-array antennas, which shows that the SHG radiation is highly structured. Because of its sensitivity to local asymmetry, SHG microscopy promises to be a powerful tool for the study of membrane dynamics.  相似文献   

3.
4.
We theoretically compare the performance of TPEF and SHG microscopy for membrane potential imaging. We argue that electrochromic TPEF and SHG membrane potential responses are reflections of the same phenomenon, and can be described in a unified manner as resulting from the linear Stark effect. We also show that TPEF and SHG exhibit similar sensitivities in the case of both electrochromic and orientational response mechanisms. Despite their similar sensitivities, SHG nevertheless presents advantages over TPEF for membrane potential imaging because of its remarkable spatial and spectral contrast, and because of its insensitivity to non-radiative excited-state damping mechanisms.  相似文献   

5.
双光子激发荧光(two-photon excited fluorescence, TPEF)显微是一种非线性光学显微技术, 具有高的时间分辨率和空间分辨率、高的信噪比和固有的三维层析分辨能力等优点. 传统的TPEF显微一般采用波长可调谐的超短脉冲激光器作为光源. 在实际应用中, 利用TPEF显微技术研究含有多种荧光团或未知成分的待测样品, 往往需要多次改变激发光的波长以获得对各种荧光团的最佳激发. 为了同时获取不同荧光团的荧光信号, 利用超连续谱激光光源实现了多色TPEF显微成像, 实验中无需调节波长, 能够同时获得具有两种不同发射波长的荧光标记的铃兰根茎切片样品的TPEF图像. 实验结果表明, 与传统的TPEF显微相比, 该方法能够同时获取含有多种荧光团的待测样品的高对比度TPEF图像, 具有系统结构简单、操作简便、信息量大等优点, 在生物医学和材料科学等领域具有广阔的应用前景.  相似文献   

6.
Xiong  S. Y.  Yang  J. G.  Zhuang  J. 《Laser Physics》2011,21(10):1844-1849
In this work, we use nonlinear spectral imaging based on two-photon excited fluorescence (TPEF) and second harmonic generation (SHG) for analyzing the morphology of collagen and elastin and their biochemical variations in basal cell carcinoma (BCC), squamous cell carcinoma (SCC) and normal skin tissue. It was found in this work that there existed apparent differences among BCC, SCC and normal skin in terms of their thickness of the keratin and epithelial layers, their size of elastic fibers, as well as their distribution and spectral characteristics of collagen. These differences can potentially be used to distinguish BCC and SCC from normal skin, and to discriminate between BCC and SCC, as well as to evaluate treatment responses.  相似文献   

7.
8.
The localization of surface second-harmonic generation (S-SHG) enhancements from granular gold structures that exhibit local plasmon resonance was investigated. A two-photon microscopy technique was used to perform high spatial resolution S-SHG imaging. The magnitude and the spatial density of S-SHG enhancement confined in submicroscopic regions are strongly dependent on the morphology of the gold's surface. Polarization measurements of local S-SHG responses reveal the local field anisotropy in enhancement regions and furthermore prove the incoherent and strongly depolarized nature of the emission, which is attributed to ultrafast fluctuations of the enhancement location in the focal volume.  相似文献   

9.
Chu SW  Chan MC  Tai SP  Keller S  DenBaars SP  Sun CK 《Optics letters》2005,30(18):2463-2465
We demonstrate what is to our knowledge the first example of four-photon luminescence microscopy in GaN and apply it to quality mapping of bulk GaN. The simultaneously acquired second- and third-harmonic generation can be used to map the distribution of the piezoelectric field and the band-tail state density, respectively. Through spectrum- and power-dependent studies, the fourth power dependence of the band edge luminescence is confirmed. The superb spatial resolution of the four-photon luminescence modality is also demonstrated. This technique provides a high-resolution, noninvasive monitoring and tool for examining the physical properties of semiconductors.  相似文献   

10.
Lin SJ  Wu R  Tan HY  Lo W  Lin WC  Young TH  Hsu CJ  Chen JS  Jee SH  Dong CY 《Optics letters》2005,30(17):2275-2277
The photoaging process of facial skin is investigated by use of multiphoton fluorescence and second-harmonic generation (SHG) microscopy. We obtain the autofluorescence (AF) and SHG images of the superficial dermis from the facial skin of three patients aged 20, 40, and 70 years. The results show that areas of AF increase with age, whereas areas of SHG decrease with age. The results are consistent with the histological findings in which collagen is progressively replaced by elastic fibers. The AF and SHG changes in photoaging are quantified by a SHG to autofluorescence aging index of dermis (SAAID). Our results suggest that SAAID can be a good indicator of the severity of photoaging.  相似文献   

11.
The macromolecular structure of purified cellulose samples is studied by second-harmonic generation (SHG) imaging microscopy. We show that the SHG contrast in both Valonia and Acetobacter cellulose strongly resembles that of collagen from animal tissues, both in terms of morphology and polarization anisotropy. Polarization analysis shows that microfibrils in each lamella are highly aligned and ordered and change directions by 90 degrees in adjacent lamellae. The angular dependence of the SHG intensity fits well to a cos2 theta distribution, which is characteristic of the electric dipole interaction. Enzymatic degradation of Valonia fibers by cellulase is followed in real time by SHG imaging and results in exponential decay kinetics, showing that SHG imaging microscopy is ideal for monitoring dynamics in biological systems.  相似文献   

12.
Optimization of second-harmonic generation microscopy   总被引:2,自引:0,他引:2  
We describe the principles and characteristics of second-harmonic generation imaging (SHGI) and explore various methods for optimization of the technique. Second-harmonic imaging is optimized for ultrashort laser pulses, high numerical aperture microscope objectives, a highly sensitive non-descanned large area detector, pseudo-phase-matching, and specimens with large second-order non linearity or which exhibit surface plasmon enhanced phenomena. We also compare and contrast the techniques of SHGI and two-photon excited fluorescence imaging.  相似文献   

13.
Two-color two-photon 4Pi fluorescence microscopy   总被引:1,自引:0,他引:1  
Chen J  Midorikawa K 《Optics letters》2004,29(12):1354-1356
In 4Pi fluorescence microscopy the point-spread function is composed of a strong central lobe accompanied by interference sidelobes that produce artifacts in the image. We propose to combine two-color two-photon fluorescence microscopy and 4Pi fluorescence microscopy to overcome this sidelobe problem. Simulation results show that a single sharp fluorescence spot can be produced by use of two excitation wavelengths of 400 and 800 nm and detected at 350-nm emission wavelength.  相似文献   

14.
We investigate the transverse second-harmonic generation in as grown strontium barium niobate (SBN) crystals with a random structure of anti-parallel ferroelectric domains. We consider both, single and counter-propagating pulse geometries. We investigate polarization properties of the second harmonic signal and discuss applications of this process for short pulses characterization. Presented at 9-th International Workshop on Nonlinear Optics Applications, NOA 2007, May 17–20, 2007, Świnoujście, Poland  相似文献   

15.
Lu FF  Li T  Hu XP  Cheng QQ  Zhu SN  Zhu YY 《Optics letters》2011,36(17):3371-3373
We theoretically studied a nonlinear optical process in a hybrid plasmonic waveguide composed of a nonlinear dielectric waveguide and a metal film with a separation of a thin air gap. Owing to the hybridization effect of guided mode and surface plasmon polariton mode, this particular waveguide is able to confine the optical-field in a deep subwavelength scale together with low propagation loss. Based on this, efficient second-harmonic generations (SHG) were revealed at the fundamental wavelength of λ=1.55?μm with good field confinement. The SHG efficiency, as well as the coupling coefficient and mode area, were analyzed and discussed in detail with respect to the structural parameters.  相似文献   

16.
The fluorescence power from biological tissue excited by a femtosecond laser pulse compared with excitation power does not appear to obey a simple quadratic relationship given by the steady non-linear theory.A more reliable analysis is developed based on transient two-photon absorption because the response time of two-photon absorption is longer than the width of a femtosecond pulse.Good agreement is obtained between the theoretical analysis and the experimental results of fluorescence power versus excitation power.This letter offers potential value to non-linear optics in biological tissues.  相似文献   

17.
介绍采用双光子激发荧光方法进行单分子探测的原理和自行研制的实验装置,激发光聚焦和荧光收集采用共焦方式。选择香豆素C445水溶液作为研究对象,从样品流速、浓度、激光功率、信噪比和检测限等方面探讨了双光子激发荧光的特性。该谱仪目前己达到探测灵敏区内C445的平均分子数为1.5个的检测限  相似文献   

18.
Buffa R 《Optics letters》2002,27(12):1058-1060
An optimal control approach is used to extend to the regime of pump depletion the idea of using spatially nonuniform nonlinear coefficients to tailor the shapes of optical pulses in a process of transient second-harmonic generation.  相似文献   

19.
王湘晖  林列  张杨 《中国物理》2007,16(11):3285-3289
On the basis of the vector diffraction theory and Green's function method, this paper investigates the effects of refractive index mismatch on second-harmonic generation (SHG) microscopy. The polarization distribution and SHG intensity are calculated as functions of the sample radius and probe depth. The numerical results show that refractive index mismatch can result in peak intensity degradation, increase secondary lobes and extension of second- harmonic polarization distribution. Because of the attenuation of polarization intensity, the detected SHG intensity significantly decreases with increasing probe depth, which can limit the imaging depth of SHG microscopy inside thick samples. Forward SHG intensity decays slowly than backward SHG, due to the combination of extension second-harmonic polarization distribution and strong dependency of forward SHG on sample radius.[第一段]  相似文献   

20.
We demonstrate selective two-photon excited fluorescence microscopy with shaped pulses produced with a simple yet efficient scheme based on dispersive optical components. The pulse train from a broadband oscillator is split into two subtrains that are sent through different amounts of glass. Beam recombination results in pulse-shape switching at a rate of 150MHz. Time-resolved photon counting detection then provides two simultaneous images resulting from selective two-photon excitation, as demonstrated in a live embryo. Although less versatile than programmable pulse-shaping devices, this novel arrangement significantly improves the performance of selective microscopy using broadband shaped pulses while simplifying the experimental setup.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号