首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A method has been established for the determination of clioquinol (C) and its glucuronide (CG) and sulfate (CS) in biological materials. C and its internal standard were extracted with benzene-pyridine from samples. CG and CS were also hydrolyzed to C and extracted by the same method. The extracts were evaporated to dryness and redissolved in methanol. The methanol solution was subjected to HPLC using a column packed with Iatrobeads 6cp.2010 and a UV monitor (254 nm). The mobile phase was 0.1 M citric acid-methanol-n-hexane (8:86:6). The detection limit of C and 1 nmole and its recovery was above 92%.  相似文献   

2.
A high-performance liquid chromatographic method for the analysis of prostacyclin using a laboratory prepared reversed-phase column packing is described. A relative standard deviation of less than 1% was obtained for ten replicate injections. The system resolves prostacyclin from its hydrolysis product, 6-oxo-prostaglandin F1 alpha and from other prostaglandins present as impurities. These can be estimated to levels of approximately 0.5%. The separation of other unrelated prostaglandins by this method is briefly reported.  相似文献   

3.
High-performance liquid chromatographic determination of kanamycin.   总被引:3,自引:0,他引:3  
A fast, selective, and precise liquid chromatographic method for simultaneous, independent determination of kanamycins A and B is described. Sample components are separated on a pellicular cation exchanger and monitored by fluorescence using post-column on-line derivatization. Less than 0.35 mug of kanamycin B can be detected in as much as 7 mug kanamycin A injected. The detection limit for kanamycin A is less than 20 ng injected. Reproducibility of the entire chromatographic system is about 1% (2 theta) based upon repeated injections of standards. Precision of repeated process sample preparation is about 6% (2 theta). Chromatographic analysis time is less than 15 min per sample.  相似文献   

4.
A rapid and specific ion-pair reversed-phase high-performance liquid chromatographic method was developed for the determination of bleomycins. The use of 5-microns particles of less adsorptive reversed-phase packings and sodium perchlorate as ion-pairing reagent permitted a short analysis time and the transferability of the separations on different batches of the reversed-phase materials. The detection sensitivity and precision of the method demonstrated that the system is suitable for routine analysis.  相似文献   

5.
p-Nitrophenol (pNP) and its conjugated metabolites, generated in a perfused rat liver preparation, are readily separated and quantitated in serum perfusate and bile samples using a reverse-phase high-performance liquid chromatographic method. Serum perfusate samples can be analyzed following protein precipitation with acetonitrile: following protein precipitation with 1.5 M perchloric acid (1 part to 2 parts serum) there was degradation of pNP sulfate to pNP when samples were stored at room temperature. pNP can also be analyzed in blood perfusate samples following extraction with a number of organic solvents including ethyl acetate or isobutanol-methylene chloride (4:1, v/v). Rat liver perfusions at a constant input concentration of 40 microM demonstrated a high hepatic extraction ratio of pNP (mean of 0.90) due to the formation of the sulfate and glucuronide conjugates; no pNP glucoside was detected in perfusate or bile samples.  相似文献   

6.
A rapid and sensitive analytical procedure is described for the simultaneous measurement of tolmetin (T), tolmetin glucuronide (1 beta-TG) and the isomers of tolmetin glucuronide in plasma and urine. A reversed-phase liquid chromatographic system is used with an ion-pairing mobile phase of methanol-tetrabutylammonium hydrogensulfate buffered to pH 4.5 and kept at a constant temperature of 50 degrees C. Detection is by UV at 313 nm. Plasma (0.5 ml) and urine (0.1 ml) are collected in pre-cooled containers and immediately adjusted to pH 3.0 to minimize TG isomerization and hydrolysis. Samples are then deproteinated with acetonitrile, the supernatant is evaporated to dryness and reconstituted in an acetate buffer (pH 4.5), and 50 microliters are injected onto the system. Using zomepirac as the internal standard, the measurable, linear concentration ranges are 0.05-50 micrograms/ml for T in plasma and 0.025-50 micrograms/ml for T in urine. Chromatographic peaks representing T,1 beta-TG and three isomers of TG were identified, all with retention times less than 10 min. The need for special handling of biological samples is discussed.  相似文献   

7.
A high-performance liquid chromatographic procedure requiring neither derivatization nor complex sample work-up is reported for reproducibly and sensitively determining pilocarpine in plasma. Following stabilization of pilocarpine against in vitro hydrolysis using sodium fluoride, plasma samples were extracted and the extracts chromatographed on a 5-microns, low-carbon-load (6%) C18 reversed-phase column. The assay was linear between 10 and 300 ng/ml (r = 0.998). It had sufficient sensitivity to quantitate pilocarpine at concentrations as low as 10 ng/ml (signal-to-noise ratio > or = 4) using a 500-microliters sample. The assay appears to be the first published specifically for plasma determinations and has proven capable of supporting pharmacokinetics studies of pilocarpine disposition in the anesthetized dog.  相似文献   

8.
A rapid, selective and sensitive isocratic reversed-phase high-performance liquid chromatographic method for the determination of ganciclovir in plasma samples was developed. This method, which was applied to the analysis of plasma ganciclovir from heart transplant patients under ganciclovir therapy for cytomegalovirus infections, represents a suitable analytical tool for drug monitoring and pharmacokinetic investigations.  相似文献   

9.
10.
11.
12.
An RP-HPLC method for simultaneous separation and quantification of pantoprazole and its five main impurities in pharmaceutical formulations was developed and validated. The separation was accomplished on a Zorbax Eclipse XDB C18 column (5 microm particle size, 150 x 4.6 mm id) using a gradient with mobile phase A [buffer-acetonitrile (70 + 30, v/v)], and mobile phase B [buffer-acetonitrile (30 + 70, v/v)]. The buffer was 0.01 M ammonium acetate solution with addition of 1 mL triethylamine/L of the solution, adjusted to pH 4.5 with orthophosphoric acid. The eluent flow rate was 1 mL/min, the temperature of the column was 30 degrees C, and the eluate was monitored at 290 nm. Linearity (r = 0.999), recovery (97.6-105.8%), RSD (0.55-1.90%), and LOQ (0.099-1.48 microg/mL) were evaluated and found to be satisfactory. The proposed method can be used for simultaneous identification and quantification of the analyzed compounds in pharmaceutical formulations.  相似文献   

13.
14.
A simple and sensitive high-performance liquid chromatographic method with ultraviolet detection is described for the simultaneous determination of lansoprazole and its metabolites in human serum and urine. The analytes in serum or urine were extracted with diethyl ether-dichloromethane (7:3, v/v) followed by evaporation, dissolution and injection into a reversed-phase column. The recoveries of authentic analytes added to serum at 0.05-2 micrograms/ml or to urine at 1-20 micrograms/ml were greater than 88%, with the coefficients of variation less than 7.1%. The minimum determinable concentrations of all analytes were 5 ng/ml in serum and 50 ng/ml in urine. The method was successfully applied to a pharmacokinetic study of lansoprazole in human.  相似文献   

15.
A high-performance liquid chromatographic method for the determination of usnic acid in human plasma using diclofenac sodium as internal standard is described. Plasma proteins were precipitated with methanol. A 250 mm x 4 mm I.D. Nucleosil. C18 (5 microns) column with a mobile phase consisting of methanol-phosphate buffer (pH 7.4) (70:30, v/v) was used. Chromatography was performed at ambient temperature with flow-rate of 1 ml min-1 and ultraviolet detection at 280 nm. Each analysis required no longer than 7 min. Quantification was achieved by measurement of the peak-height ratio and the absolute recovery varied from 93.8 to 97.3%. The limit of quantitation of usnic acid in plasma was 0.25 micrograms ml-1. The intra-day relative standard deviation (R.S.D.) ranged from 1.24 to 4.53% and the inter-day R.S.D. from 2.23 to 8.25% at three different concentrations. The method was applied to the determination of plasma levels of usnic acid after intravenous and oral administration to study its disposition in a healthy male rabbit.  相似文献   

16.
Ambroxol has been determined in biological fluids using a rapid and sensitive high-performance liquid chromatographic method. The samples prepared from plasma by liquid-liquid extraction were analysed on reversed-phase silica gel by competing-ion chromatography with ultraviolet detection. The method was applied to the determination of ambroxol levels in twelve healthy volunteers after oral administration of 90 mg of ambroxol in tablets of Mucosolvan and Ambrosan.  相似文献   

17.
A new procedure for the assay of D-amino acid oxidase activity has been developed. alpha-Ketoisovaleric acid, derived from D-valine, was estimated by high-performance liquid chromatography after reaction with o-phenylenediamine to give the corresponding quinoxalinol derivative. alpha-Ketovaleric acid was used as an internal standard to ensure the reproducibility of the method. As an example of application, kidney cortex homogenates were analyzed for their D-amino acid oxidase activity. The advantages of the presented procedure for the determination of the enzymatic activity in biological samples compared with previously reported procedures are discussed.  相似文献   

18.
A high-performance liquid chromatographic method is described for the determination of a fluoroquinolone, rufloxacin, and its N-desmethyl metabolite in plasma, urine and bile. Samples are chromatographed on a poly(styrene-divinylbenzene) column, the eluate being monitored with a fluorescence detector. The method was validated and a detection limit of 10 ng/ml for both rufloxacin and its metabolite in all the biological matrices considered was found. The method was successfully applied in pharmacokinetic studies.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏