首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel, simple, and sensitive method has been developed for simultaneous determination of 14 heterocyclic aromatic amines in meat product using solid‐phase extraction combined with ultrahigh‐performance supercritical fluid chromatography coupled to tandem quadrupole mass spectrometry. The analytes could be separated within 7 min and identified using their retention times and mass. The developed method was validated based on the linearity, limits of quantification, precision, and accuracy. The recovery ranged from 52.3 to 97.5% with an acceptable standard deviation, which is not higher than 6%. The limits of quantitation ranged from 0.03 to 0.17 µg/kg. The selectivity and sensitivity were satisfactory in multiple reaction monitoring mode. The method was applied to commercial meat products, and the results demonstrated that the novel method has potential for the analysis of the targets in food matrices. This is the first work reporting the simultaneous quantification of 14 heterocyclic aromatic amines by means of ultrahigh‐performance supercritical fluid chromatography coupled to tandem quadrupole mass spectrometry.  相似文献   

2.
A rapid, selective and sensitive method for analysis of trace flavonoids and its glycoside derivatives in ginkgo has proposed. Ultrasonic‐assisted extraction of sample preparation was adopted to extract trace flavonoids in ginkgo leaf and its processed product. The compounds were identified using liquid chromatography negative electrospray ionization triple quadrupole tandem mass spectrometry (MS/MS). The neutral loss scan mode of MS/MS was used to screen flavonoid compounds and those compounds with acid group, or having rhamnosyl, glucosyl, or coumaroyl moiety in the samples. The successive data‐dependent product ion scan mode of MS/MS was used to identify the structure of the components. The analytical results represented three aglycone flavonoids and seven flavonoid glycosides in ginkgo. The method detection limits were evaluated for the analytes analyzed in the range of 0.88 to 2.67 μg/mL.  相似文献   

3.
Accurate quantitation has been demonstrated on many different types of mass spectrometer. However, quantitative applications of Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) have been limited. In this study, the quantitative potential of FTICRMS has been investigated using an exact matching isotope dilution method for the determination of creatinine in serum. Creatinine is an important clinical biomarker and its measurement is used as an assessment of renal function. The quantitation of creatinine was selected because a high-accuracy high-performance liquid chromatography/mass spectrometry (HPLC/MS) determination using a triple quadrupole mass spectrometer has already been successfully developed in-house. Therefore, a direct comparison of the quantitative capability of FTICRMS could be made against an established method. The accuracy of the quantitation of creatinine was found to be equivalent to that obtained using LC/MS. However, the expanded measurement uncertainty (k = 2) was larger, at 6%, when using FTICRMS compared with 1% when using HPLC/MS with the triple quadrupole mass spectrometer.  相似文献   

4.
Flavan‐3‐ol monoglycosides, having four aglycons (+)‐catechin, (?)‐epicatechin, (?)‐epigallocatechin and epicatechin gallate monomeric units, are detected for the first time in Vitis vinifera L. cv. Merlot grape seeds and wine. These compounds were analyzed in red wine, seed and skin extracts by electrospray ionization quadrupole time of flight mass spectrometry (MS) in negative mode. Fragment ions derived from retro‐Diels Alder, heterocyclic ring fragmentation, benzofuran forming fragmentation and glycoside fragmentations were detected in targeted MS/MS mode. These compounds were not detected in skins; the comparative study showed evidence that these glycosylated compounds originate only from grape seeds. Our method allows for the identification of these glycosylated compounds based on their exact mass and their specific fragmentation pattern. However, exact glucose position on the monomeric units can not be determined. This work allowed us to partially identify 14 new flavan‐3‐ol monoglycosides, based on the exact mass of the molecular ions and their specific retro‐Diels Alder, heterocyclic ring fragmentation, benzofuran forming fragmentation and glycoside fragmentations. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
Liquid chromatography coupled to negative electrospray ionization (ESI) tandem mass spectrometry (MS/MS) employing a triple quadrupole mass spectrometer was used in the structural determination of acylated flavonoid-O-glycosides and methoxylated flavonoids occurring in Tagetes maxima. The compounds were identified by experiments in full scan mode (MS), and tandem mass experiments (MS/MS) of precursor ion scan, product ion scan, and neutral loss scan modes. In order to characterize the aglycones of the flavonoid glycosides, in-source fragmentation of the deprotonated molecule [M-H]- followed by product ion scan of the resulting aglycone [A-H]- were performed. This combined approach allowed the identification of 51 phenolic compounds, including flavonoid-O-glycosides acylated with galloyl, protocatechuoyl, coumaroyl or caffeoyl groups, methoxylated flavonoids, and hydroxycinnamic acid and phenolic acid derivatives, none of them previously reported in Tagetes maxima.  相似文献   

6.
We report a selective, sensitive and fast liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of diallyldimethylammonium chloride (DADMAC) in water. Hydrophilic interaction liquid chromatography (HILIC) was used to avoid ion-pairing reagents, which are generally employed to retain cationic compounds. The complementary information obtained in a triple quadrupole mass spectrometer and in an ion trap Orbitrap has been used to study the fragmentation of the DADMAC cation [M](+) and for the correct assignment of the products ions. The HILIC/MS/MS method developed, using electrospray ionization in positive ion mode and selected reaction monitoring (SRM) acquisition mode, led to a reliable determination and confirmation of the DADMAC cation in water samples down to 50 ng L(-1). The low detection limit achieved, in combination with the absence of matrix effects, allowed the direct analysis of samples without any pretreatment, preconcentration or clean-up step. DADMAC was determined in samples collected in a drinking water treatment plant (DWTP) in Barcelona (Spain) and it was found in the influent at the μg L(-1) level.  相似文献   

7.
In this study, an automated on-line solid-phase extraction coupled to fast liquid chromatography–tandem mass spectrometry (on-line SPE fast LC–MS/MS) method was developed for the simultaneous analysis of bisphenol A (BPA), bisphenol F (BPF), bisphenol E (BPE), bisphenol B (BPB) and bisphenol S (BPS) in canned soft drinks without any previous sample treatment. A C18 (12 μm particle size) loading column was used for the SPE on-line preconcentration before the liquid chromatography baseline separation of bisphenol compounds using a C18 Fused-Core™ (50 mm × 2.1 mm i.d.) column, which took less than 3 min. Gradient elution and heated electrospray were used to reduce matrix effect and improve ionization efficiency. To select the most intense and selective transitions, fragmentation studies were performed by multiple-stage mass spectrometry in an ion trap mass analyzer and tandem mass spectrometry in a triple quadrupole instrument, this latter instrument being used for quantitation in SRM mode. Quality parameters of the method were established and we obtained a simple, fast, reproducible (RSD values lower than 10%) and accurate (precision higher than 93%) method for the analysis of bisphenols in canned soft drinks at the ng L−1 level using matrix-matched calibration.  相似文献   

8.
This paper discusses the applicability of coupling liquid chromatography (LC) to mass spectrometry (MS) using a time-of-flight (TOF) mass analyzer for the analysis of heterocyclic amines (HAs). Accurate mass measurement (<2 mDa) with both MS-MS and in-source CID MS-MS was carried out to confirm the elemental composition of some fragments previously reported. Some isobaric assignments (fragments containing N versus CH2 and NH3 versus CD2H) were distinguished by taking advantage of the resolution provided by the TOF mass analyzer. On the other hand, the LC-MS analysis of HAs in MS acquisition mode was also performed. Quality parameters of the method were established. The linearity range extended over three orders of magnitude, limits of detection were in the pg level and good short-term precision values (R.S.D., 1.2-8.0%) were obtained. The LC-ESI-TOF method was applied to the determination of HAs in a lyophilized meat extract and the results obtained were comparable to those given by MS-MS with triple quadrupole and ion trap instruments.  相似文献   

9.
The performance of three different types of mass spectrometers (MS) coupled to high performance liquid chromatography (HPLC) was compared for trace analysis of perfluoroalkylated substances (PFAS) and fluorotelomer alcohols (FTOHs). Ion trap MS in the full scan and product ion MS2 mode, time-of-flight (TOF) high resolution MS and quadrupole MS in the selected ion mode as well as triple quadrupole tandem MS were tested. Electrospray ionisation in the negative ion mode [ESI-] was best suited for all instruments and compounds. PFAS could only be separated by a buffered mobile phase, but the presence of buffer suppressed the ionisation of FTOHs. Therefore, two independent chromatographic methods were developed for the two compound classes. Mass spectra and product ion spectra obtained by in-source and collision induced dissociation fragmentation are discussed including ion adduct formation. Product ion yields of PFAS were only in the range of 0.3 to 12%, independent from the applied MS instrument. Ion trap MS2 gave product ion yields of 20 to 62% for FTOHs, whereas only 4.1 to 5.8% were obtained by triple quadrupole tandem MS. Ion trap MS was best suited for qualitative analysis and structure elucidation of branched isomeric structures of PFAS. Providing typical detection limits of 5 ng injected in MS2 mode, it was not sensitive enough for selective trace amount quantification. TOF high resolution MS was the only technique combining high selectivity and excellent sensitivity for PFAS analysis (detection limits of 2 to 10 pg), but lacked the possibility of MS-MS. Triple quadrupole tandem MS was the method of choice for quantification of FTOHs with detection limits in the low pg range. It is also well suited for the determination of PFAS, though its detection limits of 10 to 100 pg in tandem MS mode are about one order of magnitude higher than for TOF MS.  相似文献   

10.
王静  王丹  张华  彭孝军  董珺璞 《色谱》2013,31(8):734-738
建立了人血液中二十二碳六烯酸(DHA)的杂环衍生化-气相色谱-三重四极杆质谱(GC-MS/MS)检测方法。以2-氨基-2-甲基-1-丙醇(AMP)作为DHA的杂环衍生化试剂,优化了杂化反应的最佳反应条件,并使用GC-MS/MS在多反应监测模式下,以内标法对DHA进行定量检测。在0.07~10 μg/mL范围内,线性关系良好(r2=0.9991);检出限(S/N=2.8)为0.02 μg/mL;定量限(S/N=10)为0.07 μg/mL。在高、中、低3个不同添加水平下,其平均回收率在94.40%~103.13%之间,相对标准偏差(RSD)在1.51%~3.16%之间。该方法操作简便,所需样品量少,结果准确可靠,适用于人血液中DHA的分析检测。  相似文献   

11.
Grape antioxidant dietary fiber (GADF) is a dietary supplement that combines the benefits of both fiber and antioxidants that help prevent cancer and cardiovascular diseases. The antioxidant polyphenolic components in GADF probably help prevent cancer in the digestive tract, where they are bioavailable. Mass spectrometry coupled to liquid chromatography is a powerful tool for the analysis of complex plant derivatives such as GADF. We use a combination of MS techniques, namely liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOF-MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) on a triple quadrupole, for the identification of the polyphenolic constituents of the soluble fraction of GADF. First, we separated the mixture into four fractions which were tested for phenolic constituents using the TOF system in the full scan mode. The high sensitivity and resolution of the TOF detector over the triple quadrupole facilitate the preliminary characterization of the fractions. Then we used LC/ESI-MS/MS to identify the individual phenols through MS/MS experiments (product ion scan, neutral loss scan, precursor ion scan). Finally, most of the identities were unequivocally confirmed by accurate mass measurements on the TOF spectrometer. LC/ESI-TOF-MS combined with MS/MS correctly identifies the bioactive polyphenolic components from the soluble fraction of GADF. High-resolution TOF-MS is particularly useful for identifying the structure of compounds with the same LC/ESI-MS/MS fragmentation patterns.  相似文献   

12.
A new ultra-performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-ESI-MS/MS) method was developed to perform the determination of 16 mutagenic heterocyclic amines (HAs) in complex food samples in less than 2 min. The UPLC separation was carried out using an Acquity BEH C18 column (50 mm x 2.1 mm i.d., 1.7 microm particle size) that provided high efficiency and resolution in combination with high linear velocities. The UPLC system was coupled to the triple quadrupole Waters Micromass Quattro Premier. This system permits high-speed data acquisition without peak intensity degradation which is required to monitor the narrow chromatographic peaks (1-2 s) of HAs. The determination was performed in selected reaction monitoring (SRM) mode. The quality parameters of the developed method were established, obtaining instrumental LODs lower than 0.23 pg injected and a repeatability at low concentration level lower than 9.1% CV (n = 6). To evaluate the performance of the method in high throughput analysis of complex samples, the UPLC-MS/MS method was applied to the analysis of HAs in two meat extracts.  相似文献   

13.
A series of potent heterocyclic amines that are mutagenic and carcinogenic have been discovered that are formed in some heated foods, most notably, meats derived from muscle. Determining the heterocyclic amine content in foods and food products is required for toxicological research, industry quality control, and possibly in the future, regulatory control. The contents of food needs to be determined using reliable analytical techniques. Since heterocyclic amines are present in foods at ng/g levels, a variety of liquid-liquid or solid-phase purification techniques are required, followed by gas or high-performance liquid chromatography. Peak detection has been successful using UV, fluorescence, and mass spectrometric detection, and biological activity using the Ames/Salmonella test. The low levels present require that chromatographic efficiency, and both detector sensitivity and selectivity be optimized. The cartridge solid-phase extraction and high-performance liquid chromatography method have been used to measure the known food-derived heterocyclic amines for several types of food, and to the authors knowledge, this is the only method undergoing intralaboratory comparison and validation. Our analysis of the literature shows that chromatographic analysis of the heterocyclic amines by high-performance liquid chromatography or gas chromatography (with derivatization) is satisfactory for heterocyclic amine analysis in foods although the methods are just now being optimized for routine use. The biggest improvements in speed and accuracy will probably come from improved extraction methods as analysis of complex food samples for heterocyclic amines will always be a challenge.  相似文献   

14.
In the present work, a rapid method with little sample handling has been developed for determination of 23 selected volatile organic compounds in environmental and wastewater samples. The method is based on headspace solid-phase microextraction (SPME) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) determination using triple quadrupole analyzer (QqQ) in electron ionization mode. The best conditions for extraction were optimised with a factorial design taking into account the interaction between different parameters and not only individual effects of variables. In the optimized procedure, 4 mL of water sample were extracted using a 10 mL vial and adding 0.4 g NaCl (final NaCl content of 10%). An SPME extraction with carboxen/polydimethylsiloxane 75 μm fiber for 30 min at 50°C (with 5 min of previous equilibration time) with magnetic stirring was applied. Chromatographic determination was carried out by GC-MS/MS working in Selected Reaction Monitoring (SRM) mode. For most analytes, two MS/MS transitions were acquired, although for a few compounds it was difficult to obtain characteristic abundant fragments. In those cases, a pseudo selected reaction monitoring (pseudo-SRM) with three ions was used instead. The intensity ratio between quantitation (Q) and confirmation (q) signals was used as a confirmatory parameter. The method was validated by means of recovery experiments (n=6) spiking mineral water samples at three concentration levels (0.1, 5 and 50 μg L(-1)). Recoveries between 70% and 120% were generally obtained with relative standard deviations (RSDs) lower than 20%. The developed method was applied to surface water and wastewater from a wastewater treatment plant and from a municipal solid-waste treatment plant. Several compounds, like chloroform, benzene, trichloroethylene, toluene, tetrachloroethylene, dibromochloromethane, xylenes and bromoform were detected and confirmed in all the samples analyzed.  相似文献   

15.
Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole‐Orbitrap‐mass spectrometry (LC/ESI‐LTQ‐Orbitrap‐MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high‐resolution system (LTQ‐Orbitrap) using accurate mass measurements in MS, MS2 and MS3 modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
A ‘suspect screening analysis’ method for grape metabolomics by ultra‐high performance‐liquid chromatography (UHPLC) and high‐resolution quadrupole‐time of flight (QTOF) mass spectrometry was recently developed. This method was applied to study grape monoterpene glycosides, the main grape aroma precursors. Since standard compounds were not available, they were tentatively identified by overlapping various analytical approaches, in agreement with the indications recommended in mass spectrometry (MS)‐based metabolomics. Accurate mass and isotopic pattern, MS/MS fragmentation, correlation between fragments observed and putative structures and between liquid chromatography coupled with mass spectrometry (LC/MS) and gas chromatography/mass spectrometry signals were studied. Seventeen monoterpene glycosides were identified without performing the hydrolytic artifacts commonly used to study these compounds which may affect sample profile. This is the first time that a detailed study of these aroma precursors has been carried out by direct LC/MS analysis. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
The use of the novel atmospheric pressure chemical ionization (APCI) source for gas chromatography (GC) coupled to triple quadrupole using tandem mass spectrometry (MS/MS) and its potential for the simultaneous determination of the 12 dioxin-like polychlorobiphenyls (DL-PCBs) in complex food and feed matrices has been evaluated.  相似文献   

18.
满正印  王全林  李和生  张爱芝 《色谱》2014,32(12):1340-1348
建立了超高效液相色谱-三重四极杆质谱法(UPLC-MS/MS)同时测定水粉画颜料、油画颜料、丙烯画颜料等美术颜料中33种初级芳香胺(PAAs)的检测方法。样品中的初级芳香胺用乙腈提取,经离心分离、氮吹浓缩后,以甲醇-水(1:9, v/v)定容至2 mL, 0.22 μm膜过滤后上机检测。采用BEH Phenyl柱(100 mm×2.1 mm, 1.7 μm),以含0.07%(v/v)甲酸的甲醇溶液-水(1:9, v/v)为流动相,梯度洗脱分离,UPLC-MS/MS多反应监测模式(MRM)检测,同位素内标法定量。方法优化了色谱分离条件、质谱碎裂电压、碰撞能量等,并考察了提取时间、提取溶剂、浓缩方式等对回收率的影响。33种初级芳香胺的方法检出限为5~50 μg/kg,定量限为15~150 μg/kg, 3种不同基质样品在3个添加水平的平均回收率为70.1%~115.8%,相对标准偏差(RSD)为2.1%~15%。本方法操作简便、快速、准确、灵敏度高,能满足相关测定的要求。  相似文献   

19.
The curcuminoids are a group of diarylheptanoid molecules that possess important pharmacological activities, particularly acting as anti-inflammatory agents. The main purpose of this study was to investigate the fragmentation behavior of the three major curcuminoids in ion trap liquid chromatography/tandem mass spectrometry (LC/MS/MS). Both positive and negative mode electrospray ionization in tandem and multidimensional MS(n) experiments in quadrupole ion trap instruments and high-resolution and accurate mass MS and sustained off-resonance irradiation (SORI) MS/MS experiments in a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer were used to elucidate the main fragmentation channels of these compounds. These experiments yielded essentially the same fragmentation results in both ion trap and ICR instruments for all three curcuminoids and for their phenolic monoacetates. Major and diagnostic fragment ions were identified and their origins are proposed.  相似文献   

20.
建立了气相色谱-三重四极杆串联质谱检测环境空气中多环芳烃的方法,并利用同位素稀释法对多环芳烃进行了测定。将该方法应用于华南地区某大型石化企业周边环境空气中多环芳烃的检测,并与气相色谱-质谱方法进行了对比。结果表明,该方法的仪器检出限(0.01~0.15 μg/L)和定量限(0.03~1.5 μg/L)均优于气相色谱-质谱法(0.1~0.8 μg/L和0.3~3.5 μg/L),并有更好的灵敏度与选择性。当利用气相色谱-质谱作为检测手段时,回收率指示物氘代菲和进样内标六甲基苯均受到了杂质的严重干扰,影响了定量结果的准确性,而三重四极杆串联质谱很好地解决了这些问题。实际样品分析时,标准曲线中16种多环芳烃相对响应因子的相对标准偏差为2.60%~15.6%,氘代化合物的回收率为55.2%~82.3%,空白加标样品的回收率为98.9%~111%,平行样品的相对标准偏差为6.50%~18.4%,采样空白含量范围为未检出~44.3 pg/m3,实验室空白含量范围为未检出~36.5 pg/m3。上述研究表明,分析环境空气中的多环芳烃时,气相色谱-三重四极杆串联质谱方法值得推广。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号