首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
We report the first implementation of the fiber based microfluidic Raman spectroscopic detection scheme, which can be scaled down to micrometre dimensions, allowing it to be combined with other microfluidic functional devices. This novel Raman spectroscopic detection scheme, which we termed as Waveguide Confined Raman Spectroscopy (WCRS), is achieved through embedding fibers on-chip in a geometry that confines the Raman excitation and collection region which ensures maximum Raman signal collection. This results in a microfluidic chip with completely alignment-free Raman spectroscopic detection scheme, which does not give any background from the substrate of the chip. These features allow a WCRS based microfluidic chip to be fabricated in polydimethylsiloxane (PDMS) which is a relatively cheap material but has inherent Raman signatures in fingerprint region. The effects of length, collection angle, and fiber core size on the collection efficiency and fluorescence background of WCRS were investigated. The ability of the device to predict the concentration was studied using urea as a model analyte. A major advantage of WCRS is its scalability that allows it to be combined with many existing microfluidic functional devices. The applicability of WCRS is demonstrated through two microfluidic applications: reaction monitoring in a microreactor and detection of analyte in a microdroplet based microfluidic system. The WCRS approach may lead to wider use of Raman spectroscopy based detection in microfluidics, and the development of portable, alignment-free microfluidic devices.  相似文献   

2.
Guijt RM  Evenhuis CJ  Macka M  Haddad PR 《Electrophoresis》2004,25(23-24):4032-4057
Since the introduction of capillary electrophoresis (CE), conductivity detection has been an attractive means of detection. No additional chemical properties are required for detection, and no loss in sensitivity is expected when miniaturising the detector to scale with narrow-bore capillaries or even to the microchip format. Integration of conductivity and CE, however, involves a challenging combination of engineering issues. In conductivity detection the resistance of the solution is most frequently measured in an alternating current (AC) circuit. The influence of capacitors both in series and in parallel with the solution resistance should be minimised during conductivity measurements. For contact conductivity measurements, the positioning and alignment of the detection electrodes is crucial. A contact conductivity detector for CE has been commercially available, but was withdrawn from the market. Microfabrication technology enables integration and precise alignment of electrodes, resulting in the popularity of conductivity detection in microfluidic devices. In contactless conductivity detection, the alignment of the electrodes with respect to the capillary is less crucial. Contactless conductivity detection (CCD) was introduced in capillary CE, and similar electronics have been applied for CCD using planar electrodes in microfluidic devices. A contactless conductivity detector for capillaries has been commercialised recently. In this review, different approaches towards conductivity detection in capillaries and chip-based CE are discussed. In contrast to previous reviews, the focus of the present review is on the technological developments and challenges in conductivity detection in CE.  相似文献   

3.
Recent advance in liquid crystal (LqC) based immunoassays enables label-free detection of antibody, but manual preparation of LqC cells and injection of LqC are required. In this work, we developed a new format of LqC-based immunoassay which is hosted in a microfluidic device. In this format, the orientations of LqC are strongly influenced by four channel walls surrounding the LqC. When the aspect ratio (depth/width) of the channel is smaller than 0.38, LqC orients homeotropically inside the microchannel and appears dark. After antigens bind to immobilized antibodies on the channel walls, a shift of the LqC appearance from dark to bright (due to the disruption of LqC orientation) can be visualized directly. To streamline the immunoassay process, a tubing cartridge loaded with a sample solution, washing buffers and a plug of LqC is connected to the microfluidic device. By using pressure-driven flow, the cartridge allows antigen/antibody binding, washing and optical detection to be accomplished in a sequential order. We demonstrate that this microfluidic immunoassay is able to detect anti-rabbit IgG with a naked-eye detection limit down to 1 μg mL−1. This new format of immunoassay provides a simple and robust approach to perform LqC-based label-free immunodetection in microfluidic devices.  相似文献   

4.
We present a new approach for contactless conductivity detection for microchip-based capillary electrophoresis (CE). The detector integrates easily with well-known microfabrication techniques for glass-based microfluidic devices. Platinum electrodes are structured in recesses in-plane with the microchannel network after glass etching, which allows precise positioning and batch fabrication of the electrodes. A thin glass wall of 10-15 microm separates the electrodes and the buffer electrolyte in the separation channel to achieve the electrical insulation necessary for contactless operation. The effective separation length is 34 mm, with a channel width of 50 microm and depth of 12 microm. Microchip CE devices with conductivity detection were characterized in terms of sensitivity and linearity of response, and were tested using samples containing up to three small cations. The limit of detection for K+ (18 microM) is good, though an order of magnitude higher than for comparable capillary-based systems and one recently reported example of contactless conductivity on chip. However, an integrated field-amplified stacking step could be employed prior to CE to preconcentrate the sample ions by a factor of four.  相似文献   

5.
Single cell analytics for proteomic analysis is considered a key method in the framework of systems nanobiology which allows a novel proteomics without being subjected to ensemble-averaging, cell-cycle, or cell-population effects. We are currently developing a single cell analytical method for protein fingerprinting combining a structured microfluidic device with latest optical laser technology for single cell manipulation (trapping and steering), free-solution electrophoretical protein separation, and (label-free) protein detection. In this paper we report on first results of this novel analytical device focusing on three main issues. First, single biological cells were trapped, injected, steered, and deposited by means of optical tweezers in a poly(dimethylsiloxane) microfluidic device and consecutively lysed with SDS at a predefined position. Second, separation and detection of fluorescent dyes, amino acids, and proteins were achieved with LIF detection in the visible (VIS) (488 nm) as well as in the deep UV (266 nm) spectral range for label-free, native protein detection. Minute concentrations of 100 fM injected fluorescein could be detected in the VIS and a first protein separation and label-free detection could be achieved in the UV spectral range. Third, first analytical experiments with single Sf9 insect cells (Spodoptera frugiperda) in a tailored microfluidic device exhibiting distinct electropherograms of a green fluorescent protein-construct proved the validity of the concept. Thus, the presented microfluidic concept allows novel and fascinating single cell experiments for systems nanobiology in the future.  相似文献   

6.
Liu Y  Wipf DO  Henry CS 《The Analyst》2001,126(8):1248-1251
A conductivity detector was coupled to poly(dimethylsiloxane)-glass capillary electrophoresis microchips to monitor microfluidic flow. Electroosmotic flow was investigated with both conductivity detection (CD) and the current monitoring method. No significant variation was observed between these methods, but CD showed a lower relative standard deviation. Gradient mixing experiments were employed to investigate the relationship between the electrolyte conductivity and the electrolyte concentration. A good linear response of conductivity to concentration was obtained for solutions whose difference in concentrations were less than 27 mM. The new system holds great promise for precision mixing in microfluidic devices using electrically driven flows.  相似文献   

7.
A flexible skin‐mounted microfluidic potentiometric device for simultaneous electrochemical monitoring of sodium and potassium in sweat is presented. The wearable device allows efficient natural sweat pumping to the potentiometric detection chamber, containing solid‐contact ion‐selective Na+ and K+ electrodes, during exercise activity. The fabricated microchip electrolyte‐sensing device displays good analytical performance and addresses sweat mixing and carry‐over issues of early epidermal potentiometric sensors. Such soft skin‐worn microchip platform integrates potentiometric measurement, microfluidic technologies with flexible electronics for real‐time wireless data transmission to mobile devices. The new fully integrated microfluidic electrolyte‐detection device paves the way for practical fitness and health monitoring applications.  相似文献   

8.
Xu BB  Ma ZC  Wang L  Zhang R  Niu LG  Yang Z  Zhang YL  Zheng WH  Zhao B  Xu Y  Chen QD  Xia H  Sun HB 《Lab on a chip》2011,11(19):3347-3351
We report here a facile approach for flexible integration of high efficiency surface enhanced Raman scattering (SERS) monitors in a continuous microfluidic channel. In our work, femtosecond laser direct writing was adopted for highly localizable and controllable fabrication of the SERS monitor through a multi-photon absorption (MPA) induced photoreduction of silver salt solution. The silver substrate could be shaped into designed patterns, and could be precisely located at the desired position of the microchannel bed, giving the feasibility for real-time detection during reactions. SEM and TEM images show that the silver substrates were composed of crystallized silver nanoplates with an average thickness of 50 nm. AFM results reveal that the substrates were about 600 nm in height and the surface was very rough. As representative tests for SERS detection, p-aminothiophenol (p-ATP) and flavin adenine dinucleotide (FAD) were chosen as probing molecules for microfluidic analysis at visible light (514.5 nm) excitation, exhibiting an enhancement factor of ~10(8). In addition, the combination of the SERS substrate with the microfluidic channel allows detection of inactive analytes through in situ microfluidic reactions.  相似文献   

9.
Aside from HPLC and GC, capillary electrophoresis (CE) is one of the most important techniques for high-performance separations in modern analytical chemistry. Its main advantages are the possibility of using different detection techniques, the possibility of in-capillary sample processing for preconcentration or derivatization, and ease of instrumental miniaturization down to the microfluidic scale. Those features are utilized in the separation of macromolecules in biochemistry and in genetic investigations, but they can be also used in determinations of inorganic ions in water analysis. This review, based on about 100 original research works, presents applications of CE methods in water analysis reported in recent decade, mostly regarding conductivity detection or indirect UV detection. The developed applications include analysis of high salinity sea waters, as well as analysis of other surface waters and drinking waters.  相似文献   

10.
Vasopressin is an indicating biomarker for blood pressure in the human body and low vasopressin levels can be indicative of late-phase hemorrhagic shock or other traumatic injuries. In this paper we have developed an aptamer-based label-free microfluidic biosensor for the electrochemical detection of vasopressin. The detection area consists of aptamers immobilized on carbon nanotubes which specifically capture the vasopressin molecules in solution resulting in changes in conductivity across the sensor. We report a limit of detection of 43 pM in standard solutions and demonstrate high detection specificity toward vasopressin when different interferents are present. The miniaturized microfluidic biosensor offers continuous monitoring of different vasopressin levels with good potential for portability. Ultimately such a system could serve as a point-of-care diagnostics tool for patients with excessive bleeding when standard medical infrastructure is not available.  相似文献   

11.
Park T  Lee S  Seong GH  Choo J  Lee EK  Kim YS  Ji WH  Hwang SY  Gweon DG  Lee S 《Lab on a chip》2005,5(4):437-442
Rapid and highly sensitive detection of duplex dye-labelled DNA sequences in a PDMS microfluidic channel was investigated using confocal surface enhanced Raman spectroscopy (SERS). This method does not need either an immobilization procedure or a PCR amplification procedure, which are essential for a DNA microarray chip. Furthermore, Raman peaks of each dye-labelled DNA can be easily resolved since they are much narrower than the corresponding broad fluorescence bands. To find the potential applicability of confocal SERS for sensitive bio-detection in a microfluidic channel, the mixture of two different dye-labelled (TAMRA and Cy3) sex determining Y genes, SRY and SPGY1, was adsorbed on silver colloids in the alligator teeth-shaped PDMS microfluidic channel and its SERS signals were measured under flowing conditions. Its major SERS peaks were observable down to the concentration of 10(-11) M. In the present study, we explore the feasibility of confocal SERS for the highly sensitive detection of duplex dye-labelled DNA oligonucleotides in a PDMS microfluidic chip.  相似文献   

12.
In this work a portable microfluidic device with a reusable integrated high voltage power supply is presented, which allows for quick exchange of inexpensive disposable poly(dimethylsiloxane)(PDMS) microfluidic chips on a carrier only slightly larger than a microscope slide. The device is powered by an onboard MN21 cell battery (5 mm radius, 30 mm long) and is demonstrated through the rapid and controlled transport of a fluorescent dye through an expansion chamber geometry. Power consumption experiments demonstrate the device's ability to complete over 40 dispense-flushing cycles on a single battery.  相似文献   

13.
The trench on a printed circuit board was reconstructed to fabricate a microfluidic framework that allows low-cost production for small quantities and integration with multifunctional elements. An on-chip electrolyte regulator was thus proposed on this platform to analyze diffusion properties in laminar flow. A numerical model was developed, highlighting the interplay between the electrolyte migration and hydrodynamic properties. Solutions with dissolved sodium chloride were simulated and experimentally tested for the regulation of electrical conductivity under the guidance of the normalized Nernst-Planck equation. The diffusion mechanism and the resulting concentration field were demonstrated in detail. This approach provides a satisfactory manufacturing method and a useful tool for integrated microfluidic systems.  相似文献   

14.
Jaros M  Soga T  van de Goor T  Gas B 《Electrophoresis》2005,26(10):1948-1953
A simple rule stating that the signal in conductivity detection in capillary zone electrophoresis is proportional to the difference between the analyte mobility and mobility of the background electrolyte (BGE) co-ion is valid only for systems with fully ionized electrolytes. In zone electrophoresis systems with weak electrolytes both conductivity signal and electromigration dispersion of analyte peaks depend on the conductivity and pH effects. This allows optimization of the composition of BGEs to give a good conductivity signal of analytes while still keeping electromigration dispersion near zero, regardless of the injected amount of sample. The demands to achieve minimum electromigration dispersion and high sensitivity in conductivity detection can be accomplished at the same time. PeakMaster software is used for inspection of BGEs commonly used for separation of sugars (carbohydrates, saccharides) at highly alkaline pH. It is shown that the terms direct and indirect conductivity detection are misleading and should not be used.  相似文献   

15.
近年来,微流控纸芯片由于低成本、便携化、检测快等优点,在需要快速检测的环境分析领域中展现出了巨大的应用前景.该综述从微流控纸芯片在环境分析中的应用角度,总结归纳了微流控纸芯片在环境分析中的最新研究进展,并展望了其在未来的发展趋势与挑战.论文内容引用150余篇源于科学引文索引(SCI)与中文核心期刊中的相关论文.该综述包...  相似文献   

16.
A novel microfluidic device that can selectively and specifically isolate exceedingly small numbers of circulating tumor cells (CTCs) through a monoclonal antibody (mAB) mediated process by sampling large input volumes (>/=1 mL) of whole blood directly in short time periods (<37 min) was demonstrated. The CTCs were concentrated into small volumes (190 nL), and the number of cells captured was read without labeling using an integrated conductivity sensor following release from the capture surface. The microfluidic device contained a series (51) of high-aspect ratio microchannels (35 mum width x 150 mum depth) that were replicated in poly(methyl methacrylate), PMMA, from a metal mold master. The microchannel walls were covalently decorated with mABs directed against breast cancer cells overexpressing the epithelial cell adhesion molecule (EpCAM). This microfluidic device could accept inputs of whole blood, and its CTC capture efficiency was made highly quantitative (>97%) by designing capture channels with the appropriate widths and heights. The isolated CTCs were readily released from the mAB capturing surface using trypsin. The released CTCs were then enumerated on-device using a novel, label-free solution conductivity route capable of detecting single tumor cells traveling through the detection electrodes. The conductivity readout provided near 100% detection efficiency and exquisite specificity for CTCs due to scaling factors and the nonoptimal electrical properties of potential interferences (erythrocytes or leukocytes). The simplicity in manufacturing the device and its ease of operation make it attractive for clinical applications requiring one-time use operation.  相似文献   

17.
Contactless conductivity detector technology has unique advantages for microfluidic applications. However, the low S/N and varying baseline makes the signal analysis difficult. In this paper, a continuous wavelet transform-based peak detection algorithm was developed for CE signals from microfluidic chips. The Ridger peak detection algorithm is based on the MassSpecWavelet algorithm by Du et al. [Bioinformatics 2006, 22, 2059-2065], and performs a continuous wavelet transform on data, using a wavelet proportional to the first derivative of a Gaussian function. It forms sequences of local maxima and minima in the continuous wavelet transform, before pairing sequences of maxima to minima to define peaks. The peak detection algorithm was tested against the Cromwell, MassSpecWavelet, and Linear Matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometer Peak Indication and Classification algorithms using experimental data. Its sensitivity to false discovery rate curve is superior to other techniques tested.  相似文献   

18.
This study reports the development of a microfluidic bead-based nucleic acid sensor for sensitive detection of circulating tumor cells in blood samples using multienzyme-nanoparticle amplification and quantum dot labels. In this method, the microbeads functionalized with the capture probes and modified electron rich proteins were arrayed within a microfluidic channel as sensing elements, and the gold nanoparticles (AuNPs) functionalized with the horseradish peroxidases (HRP) and DNA probes were used as labels. Hence, two signal amplification approaches are integrated for enhancing the detection sensitivity of circulating tumor cells. First, the large surface area of Au nanoparticle carrier allows several binding events of HRP on each nanosphere. Second, enhanced mass transport capability inherent from microfluidics leads to higher capture efficiency of targets because continuous flow within micro-channel delivers fresh analyte solution to the reaction site which maintains a high concentration gradient differential to enhance mass transport. Based on the dual signal amplification strategy, the developed microfluidic bead-based nucleic acid sensor could discriminate as low as 5 fM (signal-to-noise (S/N) 3) of synthesized carcinoembryonic antigen (CEA) gene fragments and showed a 1000-fold increase in detection limit compared to the off-chip test. In addition, using spiked colorectal cancer cell lines (HT29) in the blood as a model system, the detection limit of this chip-based approach was found to be as low as 1 HT29 in 1 mL blood sample. This microfluidic bead-based nucleic acid sensor is a promising platform for disease-related nucleic acid molecules at the lowest level at their earliest incidence.  相似文献   

19.
CE frontal analysis (CE-FA) has been established as a powerful tool to study noncovalent interactions between macromolecules and small molecules such as drug substances or pharmaceutical excipients. However, when using traditional commercial CE instrumentation, a serious drawback is related to the fact that only UV-active compounds can be studied. In recent years, contactless conductivity detection has become an attractive alternative to UV detection in CE due to its high versatility. In this study, we combine contactless conductivity detection and UV detection in a highly versatile setup for profiling noncovalent interactions between low-molecular-weight molecules and macromolecules. In the case of molecules having a chromophore the setup allows determination of binding constants using two independent detectors. The new contactless conductivity detection cell is compatible with commercial CE instrumentation and is therefore easily implemented in any analysis laboratory with CE expertise.  相似文献   

20.
This work demonstrates the development of microfluidic compact discs (CDs) for protein purification and fractionation integrating a series of microfluidic features, such as microreservoirs, microchannels, and microfluidic fractionators. The CDs were fabricated with polydimethylsiloxane (PDMS), and each device contained multiple identical microfluidic patterns. Each pattern employed a microfluidic fractionation feature with operation that was based on the redirection of fluid into an isolation chamber as a result of an overflow. This feature offers the advantage of automated operation without the need for any external manipulation, which is independent of the size and the charge of the fractionated molecules. The performance of the microfluidic fractionator was evaluated by its integration into a protein purification microfluidic architecture. The microfluidic architecture employed a microchamber that accommodated a monolithic microcolumn, the fractionator, and an isolation chamber, which was also utilized for the optical detection of the purified protein. The monolithic microcolumn was polymerized “in situ” on the CD from a monolith precursor solution by microwave-initiated polymerization. This technique enabled the fast, efficient, and simultaneous polymerization of monoliths on disposable CD microfluidic platforms. The design of the CD employed allows the integration of various processes on a single microfluidic device, including protein purification, fractionation, isolation, and detection.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号