首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
It is challenging to screen and identify bioactive compounds from complex mixtures. We review a recently developed technique that couples high-performance liquid chromatography (HPLC) to on-line, post-column (bio)chemical assays and parallel chemical analysis to screen and identify bioactive compounds from complex mixtures without the need for cumbersome purification and subsequent screening. In this system, HPLC separates complex mixtures and a post-column (bio)chemical assay determines the activity of the individual compounds present in the mixtures. Parallel chemical-detection methods (e.g., diode-array detection, mass spectrometry and nuclear magnetic resonance) identify and quantify the active compounds simultaneously. We focus on relatively widely used on-line, post-column assays for antioxidant screening and less widely used hyphenated systems involving assays based on enzymes and receptors. These strategies have proved to be very useful for rapid profiling and identification of individual active components in mixtures to provide a powerful method for natural product-based drug discovery.  相似文献   

2.
Liquid chromatography (LC) was coupled on-line to a homogeneous continuous-flow protease assay using fluorescence resonance energy transfer (FRET) as a readout for the screening of inhibitors of an enzyme (e.g., Subtilisin Carlsberg). The inhibitors aprotinin (a protein of approximately 6500 g/mol) and 4-(2-aminoethyl)benzenesulfonyl fluoride hydrochloride (AEBSF, 240 g/mol) were mixed with other, non-active compounds and separated on a size-exclusion chromatography column. After the separation, the analytes were eluted to the postcolumn reactor unit where the enzyme solution and subsequently the FRET peptide substrate were added; by measuring the fluorescence intensity the degree of inhibition was monitored on-line. As expected, only the two inhibitors caused a change in the FRET response. Detection limits for aprotinin were 5.8 microM in the flow injection analysis (FIA) mode and 12 microM in the on-line LC mode. System validation was performed by determining IC50 values for aprotinin for the FIA mode (19 microM) and the on-line mode (22 microM). These IC50 values were in line with the value determined in batch experiments (25 microM). With this system, chemical information (i.e., chromatographic retention time) and biological information (i.e., enzyme inhibition) can be combined to characterize mixtures.  相似文献   

3.
Xanthine oxidase (XO) catalyzes the metabolism of hypoxanthine and xanthine to uric acid, the overproduction and/or underexcretion of which could cause the incidence of hyperuricemia such as gout. Herein, the inhibition of XO is recognized as one of the therapeutic approaches to treat gout. In the present study, an off‐line fluorescence‐based microplate method was first developed for an XO assay in which the enzyme converted pterin to its fluorescent metabolite isoxanthopterin. Then, a postcolumn continuous XO assay as a means of bioactivity assessment was coupled to HPLC separation to establish the online HPLC with diode array detection, biochemical detection, and MS/MS system for the screening of XO inhibitors. The availability of the online system was first tested with a positive drug, allopurinol, a well‐known XO inhibitor, and subsequent analysis of Scutellaria baicalensis extract showed that two main bioactive compounds with XO inhibitory activities were observed, indicating that the developed online system was applicable to complex mixtures.  相似文献   

4.
This study describes our development of a microfluidic reaction scheme for the synthesis of fused indoline ring systems found in several bioactive compounds. We have utilized a continuous-flow microfluidic reactor for the reaction of hydrazines with latent aldehydes through the interrupted Fischer indolization reaction to form fused indoline and azaindoline products. We have identified optimal conditions and evaluated the scope of this microfluidic reaction using various hydrazine and latent aldehyde surrogates. This green chemistry approach can be of general utility to rapidly produce indoline scaffolds and intermediates in a continuous manner.  相似文献   

5.
This work presents an application of microfabricated reactors and detectors for photochemical reactions. Two fabrication schemes were demonstrated for the integration of the reaction and the detection modules: coupling individually packaged chips, and monolithic integration of the two functions. In the latter fabrication scheme, we have succeeded in bonding quartz wafers to patterned silicon wafers at low temperature using a Teflon-like polymer-CYTOP[trade mark sign]. Using quartz substrates allows reaction and detection with UV light of lower wavelengths than Pyrex substrates permit. The pinacol formation reaction of benzophenone in isopropanol was the model reaction to demonstrate the performance of the microreactors. The extent of reaction was controlled by varying the flow rate and therefore the on-chip residence time. Crystallization of the product inside the microreactors was avoided by the continuous-flow design. Instead, crystallization was observed in the effluent storage device. Off-chip analysis using HPLC confirms the results obtained from the on-line UV spectroscopy. The quantum yield estimated suggests that the reactor design is effective in improving the overall efficiency of the reactor unit.  相似文献   

6.
The development of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the simultaneous determination of 16 mycotoxins possibly related to the 'Sick Building Syndrome' on filters and in fungal cultures is described. Fungi-surface sampling as regards the 'Sick Building Syndrome' preferably happens by scraping off fungal material and vacuuming onto cellulose filters. Therefore, these two media were used as samples. They were spiked with nivalenol, deoxynivalenol, zearalenone, diacetoxyscirpenol, T-2 toxin, verrucarol, verrucarin A, neosolaniol, sterigmatocystin, roridin A, ochratoxin A, aflatoxin B1, aflatoxin B2, aflatoxin G1 and aflatoxin G2, which can be produced by isolates from fungi-damaged buildings. Deepoxy-deoxynivalenol was used as internal standard. Samples were extracted with organic solvents and the different mycotoxins were separated by high-performance liquid chromatography (HPLC) using a C18 reversed-phase SunFire analytical column and a mobile phase of variable mixtures of ammonium acetate (10 mM) and sodium acetate (20 microM) in water (solvent A) and in methanol (solvent B). The samples were run on-line with a Micromass Quattro Micro triple quadrupole mass spectrometer in positive electrospray ionisation mode using multiple reaction monitoring (MRM). The detection limits of the procedure varied from 50 to 0.009 pg/microL for filter samples and from 75 to 0.04 pg/microL for fungal culture samples. As the method includes few and non-labourious sample treatment steps, it should allow for a high throughput of samples.  相似文献   

7.
田庆国  戴军  丁霄霖 《色谱》2000,18(4):291-294
 利用液相色谱 /电喷雾质谱联用技术对柚皮中的柠檬苦素类似物配糖体进行了定向分析 ,在柚皮的乙醇提取物中检测出奥巴叩酮配糖体和诺米林配糖体。利用制备液相色谱对这两种柠檬苦素类似物配糖体进行纯化 ,并用核磁共振对其结构进行鉴定。测定结果表明 ,液质联用法不需标样即可对柑桔中的柠檬苦素类似物配糖体进行定性分析。方法准确、快速、简便。  相似文献   

8.
Danggui Buxue Tang (DBT), a classical traditional Chinese formula comprising Radix Angelicae Sinensis (RAS) and Radix Astragali (RA), has been widely used to treat menopausal irregularity in Chinese women for nearly 800 years. In this study, a comprehensive analytical method of simultaneously determining the main types of bioactive constituents, eighteen in all from the formula, involving flavonoids, saponins, organic acid and some volatile compounds, was developed. This method was based on HPLC coupled to a diode array and evaporative light scattering detectors (HPLC-DAD-ELSD) on a common reverse-phase C(18) column. Liquid chromatography coupled with on-line electrospray ionization mass spectrometry (LC-ESI-MS) was also used to further validate and analyze the constituents. It was found that 0.3% aqueous formic acid and acetonitrile was the optimum mobile phase for gradient elution. This method, which showed good precision and accuracy, was successfully used to quantify the bioactive constituents in six products. As a result, the validated HPLC method, together with the LC-ESI-MS analysis, provided a new basis for assessing the quality of traditional Chinese medicinal compound preparations (TCMCPs) consisting of many bioactive components.  相似文献   

9.
A reversed-phase high-performance liquid chromatography system with UV-detector was equipped with an on-line acetylcholinesterase inhibition assay to achieve effect-directed analysis of potentially toxic samples. The enzyme activity was detected colorimetrically using Ellman's reagent. The inhibition and substrate conversion took place in glass capillaries at a 100 microL/min flow rate. Extra-column band spreading in the reaction coils reduces the sensitivity and separation power of biochemical detectors severely. Knitted reactors exhibited no reduction of longitudinal dispersion in the tested flow range. The implementation of air-segmentation allowed an extended inhibition and substrate conversion time without a significant loss of chromatographic resolution. The limit of detection of two model compounds carbofuran (carbamate) and paraoxon-ethyl (organophosphate) was determined to be 13 ng (injected mass) and 7.4 ng, respectively, applying an isocratic chromatography method. A mixture of five insecticides was separated by a gradient elution and the inhibitory effect on the enzyme activity could be detected with high resolution. The band width at half height of the enzyme inhibition detector signal after a reaction time of about 8 min or 4.2 m of capillary, respectively, increased only by a factor of 1.4 compared to the UV-detector signal.  相似文献   

10.
张艳梅  康经武 《色谱》2013,31(7):640-645
发展了毛细管电泳(CE)和高效液相色谱-质谱(HPLC-MS)相结合的用于天然产物中活性成分筛选和鉴定的方法。该方法中,用HPLC半制备柱对天然产物粗提物进行分离纯化,再用CE对HPLC纯化后的组分进行活性测试。根据HPLC-MS/MS提供的二级质谱数据,即可确定活性成分的化学结构。以乙酰胆碱酯酶为实验模型,对我们发展的筛选方法进行了验证。从黄连粗提物中确定了药根碱、巴马汀等7种活性成分,并通过CE测定了它们的半抑制率(IC50)值。与传统的天然产物分离纯化和活性筛选方法相比,该方法具有简单、微量、快速、准确的优点。本文建立的方法为天然产物粗提物中活性成分的筛选提供了新技术。  相似文献   

11.
Capillary liquid chromatography (LC) using a 320 microns column and a flow rate of 10 microL/min has been coupled to an ion trap mass spectrometer using electrospray ionisation (ESI) to enable the rapid and effective identification of metabolites in urine, following oral administration of a novel human neutrophil elastase inhibitor, GW311616. Metabolites were identified from their mass (MS) spectra and tandem (MS/MS) mass spectra using minimal sample (1 microL of urine) and no sample pretreatment. Sensitivity assessment has shown that both molecular weight and structural information is obtainable on as little as 5 pg of compound, making the capillary LC/ion trap system as described an ideal analytical tool for the detection and characterisation of low level metabolites in biofluids (particularly when sample volume is limited). This level of detection was unattainable using a triple quadrupole mass spectrometer operating in full-scan mode, although 200 fg on column was detected using selected reaction monitoring target analysis.  相似文献   

12.
Reversed-phase HPLC was coupled on-line to a rapid, competitive affinity probe capillary electrophoresis (APCE) assay to screen mixtures for compounds that inhibit protein-ligand interactions. The Fyn Src homology 2 (SH2) domain and its phosphopeptide binding partner were used as a model interaction for demonstration of this technique. In the method, mixtures containing possible inhibitors of binding were separated by HPLC at a flow rate of 0.3 mL/min. A small portion of effluent was directed to a fluidic tee where it was mixed on-line with Fyn SH2 domain and a fluorescent phosphopeptide ("affinity probe") known to bind selectively to Fyn SH2 domain. Electropherograms of the reaction mixture were collected on-line at approximately 6s intervals using a flow-gated interface to control injections onto the capillary electrophoresis with laser-induced fluorescence system. The resulting electropherograms contained two peaks, one corresponding to the free affinity probe and the other a complex of the affinity probe and Fyn SH2 domain. Compounds that bound the protein were detected as a decrease in the peak height of the complex and an increase in the peak height of affinity probe with relative standard deviations of <5%. The assay was shown to resolve multiple peptidergic inhibitors and selectively detect them within a complex mixture of peptides. Signals were dependent upon both concentration of active peptide and its potency in binding inhibition. Detection limits were in the range of 2-11 microM depending upon the peptide. Common organic solvents used in HPLC were shown to have minimal effect in the on-line measurement up to approximately 60% in the mobile phase.  相似文献   

13.
Several configurations using 6- and 10-port switching valves were studied for high flow, on-line extraction of rat plasma coupled to an electrospray triple quadrupole mass spectrometer. Each plasma sample was diluted 1:1 with an aqueous internal standard solution. The sample was injected into a 2.1 x 20 mm cartridge column packed with 25 microm divinylbenzene/N-vinylpyrrolidone packing using 100% aqueous mobile phase at 4 mL/min. After sample loading and sample cleanup, the analytes were eluted from the extraction column with a 1.0-min gradient at 0.4 mL/min. The samples were either analyzed directly after elution from the extraction column or after additional separation using a short high performance liquid chromatography (HPLC) column. The different configurations were tested using an acidic drug (diflunisal) and a basic drug (clemastine) in rat plasma. On-line analysis was performed by injecting 200 microL of diluted plasma. The mass spectrometer was operated in the multiple reaction monitoring (MRM) mode. All calibration standards gave relative standard deviations (RSDs) below 5%. The total time per sample was 3 min.  相似文献   

14.
张宇平  施树云  陈林  陈晓青  张水寒 《色谱》2017,35(3):274-279
中药活性成分的快速分离分析一直是中药研究的重点和热点问题。该文建立了在线亲和固相萃取-高效液相色谱-二极管阵列检测-四极杆飞行时间质谱技术快速筛选中药中与α-葡萄糖苷酶有结合作用的活性成分的方法。四通阀和六通进样阀组成接口界面,收集亲和固相萃取柱中与α-葡萄糖苷酶有结合作用的活性成分,接着进入液相色谱系统进行分析鉴定。阳性对照品((+)-儿茶素)和阴性对照品(水杨酸)混合物筛选确定了方法的特异性和准确性。接着,以玉竹为研究对象,筛选出9种主要的α-葡萄糖苷酶抑制活性化合物,包括5种苯乙基肉桂酰胺类化合物,4种双氢高异黄酮类化合物。结果表明建立的方法简便、快速、特异性强,可用于任何复杂体系中α-葡萄糖苷酶结合活性成分的筛选。  相似文献   

15.
A sensitive and specific LC-MS/MS assay for the determination of paclitaxel and its 3'p- and 6-alpha-hydroxy metabolites is presented. A 200 microL plasma aliquot was spiked with a 13C6-labeled paclitaxel internal standard and extracted with 1.0 mL tert-butylmethylether. Dried extracts were reconstituted in 0.1 M ammonium acetate-acetonitrile (1:1, v/v) and 25 microL volumes were injected onto the HPLC system. Separation was performed on a 150 x 2.1 mm C18 column using an alkaline eluent (10 mm ammonium hydroxide-methanol, 30:70, v/v). Detection was performed by positive ion electrospray followed by tandem mass spectrometry. The assay quantifies a range for paclitaxel from 0.25 to 1000 ng/mL and metabolites from 0.25 to 100 ng/mL using 200 microL human plasma samples. Validation results demonstrate that paclitaxel and metabolite concentrations can be accurately and precisely quantified in human plasma. This assay is now used to support clinical pharmacologic studies with paclitaxel.  相似文献   

16.
A mass spectrometry (MS)-based methodology for enzymatic assay in equilibrium conditions was designed and evaluated. This on-line assay involves the introduction of a continuous-flow step gradient (CFSG) of a substrate solution in the column containing immobilized enzyme and the simultaneous tracking of the product formation. We showed that the constant concentration of substrate in the entire bioreactor for an appropriate duration ensures the equilibration of the studied enzyme (mushroom tyrosinase). Under these conditions, it was demonstrated also that the kinetic and enzymatic parameters (Michaelis-Menten constant, K(M) , the maximal specific activity, SA(max)) are independent of the flow rate of the mobile phase. The feasibility of the mentioned approach for inhibitory tests was also investigated. The coupling of the mass spectrometer to the bio-reactor allows the selective monitoring of the enzymatic reaction products and increases their detection level. Very high sensitivity, 500 pmol/min/column, and selective monitoring of the products of the enzymatic reaction are allowed by MS detection. The methodology developed here constitutes a sensitive analytical tool to study enzymes requiring long equilibration times.  相似文献   

17.
In the screening of complex mixtures, for example combinatorial libraries, natural extracts, and metabolic incubations, different approaches are used for integrated bioaffinity screening. Four major strategies can be used for screening of bioactive mixtures for protein targets—pre-column and post-column off-line, at-line, and on-line strategies. The focus of this review is on recent developments in post-column on-line screening, and the role of mass spectrometry (MS) in these systems. On-line screening systems integrate separation sciences, mass spectrometry, and biochemical methodology, enabling screening for active compounds in complex mixtures. There are three main variants of on-line MS based bioassays: the mass spectrometer is used for ligand identification only; the mass spectrometer is used for both ligand identification and bioassay readout; or MS detection is conducted in parallel with at-line microfractionation with off-line bioaffinity analysis. On the basis of the different fields of application of on-line screening, the principles are explained and their usefulness in the different fields of drug research is critically evaluated. Furthermore, off-line screening is discussed briefly with the on-line and at-line approaches.  相似文献   

18.
Reactive oxygen species (ROS) can damage proteins, cause lipid peroxidation, and react with DNA, ultimately resulting in harmful effects. Antioxidants constitute one of the defense systems used to neutralize pro-oxidants. Since pro-oxidants and antioxidants are found ubiquitously in nature, pro-and antioxidant effects of individual compounds and of mixtures receive much attention in scientific research. A major bottleneck in these studies, however, is the identification of the individual pro-oxidants and antioxidants in mixtures. Here, we describe the development and validation of an on-line post-column biochemical detection system for ROS-producing compounds and antioxidants in mixtures. Inclusion of cytochrome P450s and cytochrome P450 reductase also permitted the screening of compounds that need bioactivation to exert their ROS-producing properties. This pro-oxidant and antioxidant detection system was integrated on-line with gradient HPLC. The resulting high-resolution screening technology was able to separate mixtures of ROS-producing compounds and antioxidants, allowing each species to be characterized rapidly and sensitively.  相似文献   

19.
Inhibition of uridine diphosphate glucuronosyltransferase (UGT), a major drug-metabolyzing enzyme, has been studied using an on-line drug-metabolism system integrated into capillary electrophoresis. Microsomes isolated from rat liver were encapsulated in tetramethoxysilane (TMOS)-based silica matrices within a capillary in a single step under mild conditions. This microsome-immobilized capillary column allows both the metabolism of drugs and determination of the metabolites in a single capillary simultaneously, just by injecting the substrate-coenzyme mixture onto the column. Glucuronidation of acetaminophen, a widely used pharmaceutical analgesic and antipyretic agent, was investigated using this system. The glucuronidation was inhibited by 4-nitrophenol (4NP) or probenecid that was injected onto a column along with the substrate-coenzyme mixture. On the other hand, valproate did not inhibit the metabolizing reaction. The extents of inhibition using encapsulated UGT were almost the same as those obtained using free UGT. On the other hand, this electrophoretic enzyme-inhibitor assay in microfabricated devices consumes 10(4) less sample and 10(3) less microsome per experiment compared to the conventional reaction schemes. These results demonstrate that this on-line system can circumvent laborious procedures for the isolation and determination of drug metabolites from the reaction mixtures required in the conventional schemes and can provide an attractive alternative technique for the analysis of drug interactions in the metabolic pathways.  相似文献   

20.
Time series data can provide valuable insight into the complexity of biological reactions. Such information can be obtained by mass-spectrometry-based approaches that measure pre-steady-state kinetics. These methods are based on a mixing device that rapidly mixes the reactants prior to the on-line mass measurement of the transient intermediate steps. Here, we describe an improved continuous-flow mixing apparatus for real-time electrospray mass spectrometry measurements. Our setup was designed to minimize metal–solution interfaces and provide a sheath flow of nitrogen gas for generating stable and continuous spray that consequently enhances the signal-to-noise ratio. Moreover, the device was planned to enable easy mounting onto a mass spectrometer replacing the commercial electrospray ionization source. We demonstrate the performance of our apparatus by monitoring the unfolding reaction of cytochrome C, yielding improved signal-to-noise ratio and reduced experimental repeat errors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号