首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 24 毫秒
1.
The possibilities for universal calibration based on multi-element aqueous standard solutions and graphite laboratory reference materials (graphite standards) for the electrothermal vaporization inductively coupled plasma optical emission spectrometric (ETV ICP OES) determination of Al, B, Ba, Cd, Co, Cr, Cu, Fe, Mn, Ni, P, Pb, S, Sr, Ti, V, and Zn in plant materials were investigated. A commercially available state-of-the-art ETV device was coupled with an Echelle ICP spectrometer equipped with a charge-injection-device (CID) camera for spectral detection. The transition area between transport tube and ETV graphite tube and the gas streams for inner gas, bypass gas, and modifier gas were optimized to achieve best transport efficiencies. The influence of four gaseous modifiers (CCl4, CHCl3, CCl2F2, and C3H8) added to the inner gas was studied. Five reference materials (RM P-Alfalfa, Lucerne; NIES CRM No.9 “Sargasso”; CTA-VTL-2 Virginia Tobacco Leaves; NIST SRM 1515 Apple Leaves; IAEA-V-10 Hay Powder) were used for method validation. If certified reference materials are not available, calibration against graphite standards or dried aqueous standard solutions is possible. Three carbonization procedures as sample pretreatment for the plant materials were investigated. Figure Picture of the ETV system (sample changer and graphite-tube furbace) used in this work Presented at the European Symposium on Atomic Spectrometry (ESAS) September 28-October 1, 2008, Weimar, Germany.  相似文献   

2.
Glow discharge atomic emission spectroscopy (GD-OES) and the classical spectrographic method with a dc arc source (DC-ARC OES) have been applied to the direct analysis of SiC powders. The homogeneity of pellets prepared from mixtures of SiC with copper powder and used for the GD experiments was investigated in detail. Various methods have been tested for the analytical calibration. These have been applied to the direct solid sample analysis of technical SiC powders. The experimental data were evaluated by chemometrical procedures. The results of the two methods have been compared.  相似文献   

3.
Comparisons between LIBS and ICP/OES   总被引:3,自引:0,他引:3  
In the framework of the development of new techniques, the ability of laser-induced breakdown spectroscopy (LIBS) to analyse remotely complex aqueous solutions was investigated. The jet configuration with a collimated gas stream was chosen because it appeared to be the most promising method for the LIBS probe, particularly in terms of sensitivity and repeatability. For emission collection, the echelle spectrometer offers a simultaneously recorded wavelength range from the UV to the near IR and is interesting for multielemental analysis for LIBS and also for inductively coupled plasma (ICP) optical emission spectroscopy (OES). The importance of parameters influencing the quantitative results of LIBS such as multispecies analysis, sheath gas, use of an internal standard and temporal parameters for analysis is described. LIBS quantitative data have been directly compared with results from the more standard ICP/OES technique.  相似文献   

4.
A method has been developed for the determination of cobalt, copper and manganese in green coffee using direct solid sampling electrothermal atomic absorption spectrometry (SS-ET AAS). The motivation for the study was that only a few elements might be suitable to determine the origin of green coffee so that the multi-element techniques usually applied for this purpose might not be necessary. The three elements have been chosen as test elements as they were found to be significant in previous investigations. A number of botanical certified reference materials (CRM) and pre-analyzed samples of green coffee have been used for method validation, and inductively coupled plasma optical emission spectrometry (ICP OES) after microwave-assisted acid digestion of the samples as reference method. Calibration against aqueous standards could be used for the determination of Mn and Co by SS-ET AAS, but calibration against solid CRM was necessary for the determination of Cu. No significant difference was found between the results obtained with the proposed method and certified or independently determined values. The limits of detection for Mn, Cu and Co were 0.012, 0.006 and 0.004 μg g−1 using SS-ET AAS and 0.015, 0.13 and 0.10 μg g−1 using ICP OES. Seven samples of Brazilian green coffee have been analyzed, and there was no significant difference between the values obtained with SS-ET AAS and ICP OES for Mn and Cu. ICP OES could not be used as a reference method for Co, as essentially all values were below the limit of quantification of this technique.  相似文献   

5.
This article discusses the requirements for reference materials (RMs) for measuring the size of nanoparticles (NPs). Such RMs can be used for instrument calibration, statistical quality control or interlaboratory comparisons. They can come in the form of suspensions, powders or matrix-embedded materials [i.e. NPs integrated in a natural matrix (e.g., food, soil, or sludge)].At present, uncertainty about the most suitable form of material, the most relevant measurands and the most useful metrological-traceability statement inhibits the production of NP RMs. In addition, the lack of validated methods and qualified laboratories to produce NP RMs present formidable challenges.Metal, inorganic and organic NPs are available, but most of them are intended to be laboratory chemicals. With the exception of latex materials, certified RMs are not available, although some metrology institutes have started to develop such materials for colloidal gold and silica particles.  相似文献   

6.
《Analytical letters》2012,45(6):960-971
A fast procedure to determine essential and toxic metals in Brazilian human milk by ICP OES is proposed. Mature and colostrum human milk samples were mineralized using closed-pressurized and high-performance microwave digestion oven. Aqueous calibration was performed for all analytes investigated. A reference material, Infant Formula, was analyzed to test the accuracy of the proposed methodology. Recovery rates ranged between 83 and 117%. The precision of the method was better than 3.3% (R.S.D.) for all analytes investigated. Higher concentrations, on average, of the metals studied in the colostrum human milk could be found in relation to the mature human milk.  相似文献   

7.
Four procedures based on closed-vessel microwave-assisted wet digestion with different oxidative reagents, including HNO3 (P1), HNO3 + H2O2 (P2), aqua regia (P3) and Lefort aqua regia (P4), for preparation of calcium (Ca)-rich materials prior to determination of total concentrations of Al, Ca, Cd, Fe, Mg and P by inductively coupled optical emission spectrometry (ICP OES) were compared. It was found that digestion with Lefort aqua regia (P4) provided the best results for all examined elements, i.e., precision of 0.30–4.4%, trueness better than 2%, recoveries of added elements between 99.5–101.9%, and limits of detection within 0.08–1.8 ng g−1. Reliability of this procedure was verified by analysis of relevant certified reference materials (CRMs), i.e., Natural Moroccan Phosphate Rock—Phosphorite (BCR-O32). Additionally, selection of appropriate analytical lines for measurements of element concentrations, linear dynamic ranges of calibration curves and matrix effects on the analyte response were extensively investigated. Finally, the selected procedure was successfully applied for routine analysis of other Ca-rich materials, i.e., CRMs such as NIST 1400 (Bone Ash), CTA-AC-1 (Apatite Concentrate Kola Peninsula) and NCS DC70308 (Carbonate Rock), and six natural samples, such as a dolomite, a phosphate rock, an enriched superphosphate fertilizer, pork bones, pork bones after incineration, and after steam gasification.  相似文献   

8.
A procedure has been developed for the simultaneous determination of traces amounts of Cd, Cr, Cu, Mn, Ni and Pb from saline oil-refinery effluents and digested vegetable samples using inductively coupled plasma optical emission spectrometry (ICP OES). The procedure is based on cloud point extraction (CPE) of these metals as 2-(bromo-2-pyridylazo)-5-diethyl-amino-phenol (Br-PADAP) complexes into a micellar phase of octylphenoxypolyethoxyethanol (Triton X-114). Optimization of the procedure was performed by response surface methodology (RSM) using a Doehlert design. Principal components (PC) were used to simplify the multiple response analysis. A response surface for the first PC score is useful in determining the optimum conditions for the Cd, Cr, Cu, Mn and Pb determinations whereas the second PC is highly correlated with the Ni response. Improvement factors of 22, 36, 46, 25, 65 and 39, along with limits of detection (3σB) of 0.081, 0.79, 0.38, 0.83, 0.28 and 0.69 μg L−1, and precision expressed as relative standard deviation (%R.S.D., n = 8, 20.0 μg L−1) of 1.5, 2.2, 3.5, 2.6, 2.5 and 2.5 were achieved for Cd, Cr, Cu, Mn, Ni and Pb, respectively. The accuracy was evaluated by spike tests in oil-refinery effluent samples and analysis of a vegetable certified reference material (NIST 1571, orchard leaves). Results found were in agreement with certified values.  相似文献   

9.
Techniques for the direct analysis of powdered samples provide an advantageous alternative to methods using wet digestion in sample preparation. The direct spectrochemical methods based on electrothermal vaporization (ETV-ICP-OES, solid-ETV-AAS, etc.) show a great similarity to the classical method of dc arc excitation, used in spectrography. Owing to this, the classical dc arc spectrographical method was used in parallel with ETV methods in the direct solid sampling analysis of river and basin sediments. The calibration procedure is the major difficulty of all techniques applied to direct solid sample analysis because of a lack of suitable reference materials. Consequently, it was necessary to verify the application of model calibration samples, preferentially using the simple dc arc OES system and both spectrographic and spectrometric evaluation. The performance parameters of the methods mentioned are compared with those published for the ETV-ICP-OES and SS-ETV-AAS methods.  相似文献   

10.
《Analytical letters》2012,45(4):809-822
Abstract

A new method based on cloud point extraction (CPE) separation and electrothermal vaporization inductively coupled plasma optical emission spectrometry (ETV‐ICP‐OES) detection was proposed for the determination of chromium species. Thenoyltrifluoracetone (TTA) was used as both an extractant for CPE of Cr(III) and a chemical modifier for ETV‐ICP‐OES determination. When the system temperature is higher than the cloud point temperature (CPT) of the selected surfactant, Triton X‐114, the complex of Cr(III) with TTA could enter the surfactant‐rich phase, whereas the Cr(VI) remained in aqueous solutions. Thus, an in situ separation of Cr(III) and Cr(VI) could be realized. The concentrated analyte was introduced into ETV‐ICP‐OES for determination of Cr(III) after proper disposal. Cr(VI) is reduced to Cr(III) prior to determining total Cr, and its assay is based on substracting of Cr(III) from total chromium. The main factors affecting cloud point extraction and the vaporization behavior of the analyte were investigated in detail. Under the optimized conditions, the limit of detection (LOD) for Cr(III) was 0.22 µg/L by preconcentration of a 10 mL sample solution, and the relative standard deviation (RSD) was 3.8% (CCr(III)=0.5 µg/mL, n=5). The proposed method was applied to the speciation of chromium in different water samples. In order to verify the accuracy of the method, a certified reference water sample was analyzed, and the results obtained were in good agreement with certified values.  相似文献   

11.
Rhatany roots (RRs) have been used in indigenous systems of medicines to treat many common illnesses due to the presence of highly active astringent and antiviral biochemical constituents that possess strong therapeutic and pharmacological properties. Due to its widespread use, the accurate knowledge on the elemental composition of this medicinal plant can set a pharmacological research platform to investigate the effect of certain elements, and their ions in mediating the human metabolism and therapy. In this work calibration-free laser-induced breakdown spectroscopy (CF-LIBS) is used to detect the elements present in RRs sample, by analyzing the characteristic emission wavelengths and their respective intensities in the laser induced plasma, without the need for using any calibration standards or methods. Many nutritional elements, which are of human health significance and instrumental in mediating the established biological activities of RRs, were identified in a relative abundance. In addition to this, our analysis identified the trace level of a few toxic elements, whose overdose due to reckless intake wreaks havoc to human health and wellbeing. The reliability of qualitative and quantitative detection of the elements in RR by LIBS were validated by the standard inductively coupled plasma optical emission spectroscopy (ICP OES), the results of which are in good agreement with LIBS data with better relative accuracy. Also, in order to discriminate, and single out any two elements with the overlapping emission wavelength in LIBS, X-ray photoelectron spectroscopy was also carried out, which in its own right is in good agreement with the elemental analysis of LIBS in general.  相似文献   

12.
An analytical method has been developed for the preconcentration of rare earth elements (REEs) in seawater for their determination by inductively coupled plasma optical emission spectrometry (ICP‐OES). An indigenously synthesized chelating resin was used for the preconcentration of (REEs) which was based on immobilization of fluorinated β‐diketone group on solid support styrene divinyl benzene. Sample solutions (adjusted to optimized pH) were passed through a polyethylene column packed with 250 mg of the resin. Experimental conditions consisting of pH, sample flow rate, sample volume and eluent concentration were optimized. The established method has been applied for the preconcentration of light, medium and heavy REEs in coastal sea water samples for their subsequent determination by (ICP‐OES). Percentage recoveries of La, Ce, Nd, Sm, Eu, Gd, Dy, Er, Yb and Lu were ≥ 95%, a preconcentration factor of 200 times, and relative standard deviations < 5% were achieved.  相似文献   

13.
The determination of trace metals in lubricating oils using atomic spectrometric methods is reviewed. The importance of such analyses for technical diagnostics as well as the specific sample characteristics related to the analyte form (metallo-organic and metal particles) is discussed. Problems related to sample pre-treatment for appropriate sample introduction and calibration are addressed as well as the strategies to overcome them. Recent trends aimed at simplifying sample manipulation are presented. The applications and scope of AAS, ICP OES and ICP MS techniques for the determination of trace metals in lubricating oil is individually discussed, as well as some present instrumental trends.  相似文献   

14.
建立了内标法测定钢铁样品中化学成分的ICP-OES分析方法。利用铟元素作为内标物质,消除了铁基体元素对被测元素的干扰,减少了废气、废液的产生。钢铁样品中16种被测元素的检测范围在0.001%-20.00%之间,检出限为0.001-0.030μg/mL,回收率为97%-110%。该方法减少了高纯物质的使用。  相似文献   

15.
A new synthesized modified mesoporous silica (MCM-41) using 5-nitro-2-furaldehyde (fural) was applied as an effective sorbent for the solid phase extraction of uranium(VI) and thorium(IV) ions from aqueous solution for the measurement by inductively coupled plasma optical emission spectrometry (ICP OES). The influences of some analytical parameters on the quantitative recoveries of the analyte ions were investigated in batch method. Under optimal conditions, the analyte ions were sorbed by the sorbent at pH 5.5 and then eluted with 1.0 mL of 1.0 mol L−1 HNO3. The preconcentration factor was 100 for a 100 mL sample volume. The limits of detection (LOD) obtained for uranium(VI) and thorium(IV) were 0.3 μg L−1. The maximum sorption capacity of the modified MCM-41 was found to be 47 and 49 mg g−1 for uranium(VI) and thorium(IV), respectively. The sorbent exhibited good stability, reusability, high adsorption capacity and fast rate of equilibrium for sorption/desorption of uranium and thorium ions. The applicability of the synthesized sorbent was examined using CRM and real water samples.  相似文献   

16.
In this study, the quantification of decarburization induced during the annealing process for the fabrication of electrical steels was carried out using glow discharge optical emission spectroscopy (GD‐OES). Different calibration methods, based on external and internal standard references, were examined to optimize the quantification of carbon concentration. Accurate calibration curves for carbon at low concentration ranges were achieved by the use of carbon intensity calibrated by the internal reference, i.e. iron intensity line. This methodology was found to be beneficial for long GD‐OES measurements, providing a better correction over changes in the overall emission intensity with the sputter time. The good depth resolution obtained by the GD‐OES technique enabled the identification of specific features in the steel microstructure related to carbide coarseness. Quantitative carbon concentration profiles were obtained by GD‐OES to evaluate the decarburization effect on the microstructure of low‐carbon steels considering different initial microstructures. The effect of the spatial distribution of carbides in these microstructures on the decarburization kinetics was also studied. Through quantitative determination of carbon elemental profiles by GD‐OES, information about the morphology of the cementite in the microstructure and its development in relation to decarburization was acquired. The depth of decarburization can accurately be determined. On the basis of the global results, GD‐OES thus emerged as being a fast and reliable technique for a better understanding of decarburization kinetics. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
Trace impurities of Cd, Cu and Pb were determined in alumina based catalysts using direct solid sampling graphite furnace atomic absorption spectrometry (DSS-GF AAS). The analyzed catalysts are widely used in petrochemical processes. The following analytical parameters were evaluated: pyrolysis and atomization temperatures, feasibility of calibration with aqueous solutions, the necessity for palladium as chemical modifier and the sample mass introduced into the atomizer. Test samples between 0.05 and 8.5 mg were used. Palladium was investigated as chemical modifier but no improvement in analytical performance was obtained and its use was considered unnecessary for all elements. The results obtained by DSS-GF AAS were compared with those of inductively coupled plasma optical emission spectrometry (ICP OES) and also with conventional solution analysis by GF AAS (Sol-GF AAS). Characteristic masses were 1.4, 9 and 20 pg, for Cd, Cu and Pb, respectively. Using DSS-GF AAS the relative standard deviation was always less than 10% and the results agreed with those obtained by Sol-GF AAS and ICP OES. Calibration using aqueous solutions showed good linearity within the working range (R2 better than 0.99). Limits of detection (3σ, n = 10) for Cd, Cu and Pb using the proposed procedure were 0.2, 22, and 1.2 ng g− 1, respectively.  相似文献   

18.
Reactivity and concentration of additives, especially activated charcoal, employed for the Lyocell process, enhance the complexity of reactions in cellulose/N-methylmorpholine-N-oxide monohydrate solutions. Analytical control of the starting materials is a basic requirement to know the concentration of heavy metals, which are potential initiators of autocatalytic reactions. Seven activated charcoal and two carbon black samples have been analyzed regarding their content of seven elements, Cr, Cu, Fe, Mn, Mo, Ni and V using direct solid sampling high-resolution continuum source graphite furnace AAS (SS-HR-CS GF AAS) and inductively coupled plasma optical emission spectrometry (ICP OES) after microwave-assisted acidic digestion as a reference method. The limits of detection of the former technique are 1-2 orders of magnitude lower than those of ICP OES and comparable to those of more sophisticated techniques. For iron the working range of HR-CS GF AAS has been expanded by simultaneous measurement at two secondary absorption lines (344,099 nm and 344,399 nm). Partial least-squares regression between measured and calculated temperatures for beginning exothermicity (Ton) has been used to investigate the prediction capability of the investigated techniques. Whereas the ICP OES measurements for seven elements resulted in an error of prediction of 3.67%, the results obtained by SS-HR-CS GF AAS exhibited a correlation coefficient of 0.99 and an error of prediction of only 0.68%. Acceptable correlation has been obtained with the latter technique measuring only three to four elements.  相似文献   

19.
Inductively coupled plasma optical emission spectrometry (ICP OES) was used to determine Mo, Cr, V and Ti, in diesel and in used fuel oil. Samples were introduced into the ICP as emulsions to reduce interferences and allow the use of inorganic standards for quantification. A comparative study between one Triton X-100 emulsion and one detergentless emulsion was made. A 23 factorial design was applied to elucidate and establish the relationship between three experimental variables: presence of HNO3, amount of diesel fuel oil (between 5 and 25%) and the presence or O2 into the Ar plasma gas flow rate. Results indicated that best performance were achieved using 10% sample (w/w) together with concentrated HNO3 (0.5 mL) and using O2 as auxiliary gas (0.047 L min−1). The use of O2 minimized both carbon deposits at the injector tip and plasma background. The addition of HNO3 resulted in good correlation between inorganic standards used for calibration, and metallo-organic standards used for sample enrichment. Analyte enriched diesel and SRM 1634b were analyzed using the optimized conditions. Recoveries from 90.1 to 106.5% were achieved, with better results for detergent emulsions which enabled limits of detection at the ng g−1 range for Mo, Cr, V and Ti and at smaller background.  相似文献   

20.
《Analytical letters》2012,45(13):2107-2121
The elemental composition of four wild edible mushroom species was determined by inductively coupled plasma optical emission spectrometry (ICP OES): scotch bonnet (Marasmius oreades), chanterelle (Cantarellus cibarius), porcini (Boletus edulis), and peppery milk-cap (Lactarius piperatus). Mushrooms are a potassium-rich food, which was confirmed in this study. M. oreades contained the highest concentration of almost all elements, except for cadmium, potassium, phosphorus, and lead. Lead and cadmium were present but at concentrations that are not hazardous to human health. A principal component analysis loading plot for elemental composition demonstrated that 95.51 percent of the total variance was present in the first two principal components. Cluster analysis separated the elements into three statistical significant clusters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号