首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid, quantitative high-performance liquid chromatographic procedure for the determination of methionine and cystine after oxidation to methionine sulfone and cysteic acid is described. The Dns derivatives of the amino acids are separated by reversed-phase chromatography with a phosphate buffer-acetonitrile gradient and detected by UV absorption at 254 nm. The procedure is validated by confirming the methionine and cystine content of ribonuclease A. The average yields of cysteic acid and methionine sulfone from triplicate analyses of ribonuclease A were 98.1% (±3.3) and 106.1% (±2.4) of the theoretical values, respectively.  相似文献   

2.
3.
A high-performance liquid chromatographic method for the determination of urinary glycolic acid is proposed, based on pre-column derivatization with phenylhydrazine coupled with the enzymatic oxidation of glycolate to glyoxylate. The phenylhydrazone formed is separated by liquid chromatography and detected at 324 nm. The minimum detectable concentration of glycolate was 10.0 mumol/l. The recovery of glycolate added to urine averaged 96.1%. The day-to-day coefficients of variation calculated by analysis of two urine samples with normal and high glycolate contents were 4.6 and 7.5%, respectively. Results of analyses of urine samples from healthy persons, idiopathic calcium stone formers and Type I primary hyperoxaluria patients are reported.  相似文献   

4.
5.
6.
The selective oxidation of methyl p-tolyl sulfide (MTS) to the corresponding sulfoxide (MTSO) by peroxyacetic acid and the subsequent rapid separation of the sulfide and sulfoxide are the basis for a fast and reliable HPLC method for the determination of this oxidizing agent in the presence of hydrogen peroxide. The time required for chromatographic separation was reduced to less than 1 min. To improve the long-term stability of the sulfoxide solution, hydrogen peroxide was decomposed catalytically by manganese dioxide. Even in the presence of a tenfold molar excess of hydrogen peroxide, a storability of at least 20 h without a significant increase in MTSO concentration was achieved. External calibration can be performed using the stable and commercially available MTSO. Real samples from a brewery cleaning-in-place disinfection process were analysed and the results were compared with those of the classical two-step titration.  相似文献   

7.
Meyer  H. D.  Jacob  K.  Vogt  W. 《Chromatographia》1982,16(1):190-191
Summary An extraction and ion-pair reversed-phase HPLC procedure is described for the separation and determination of protoporphyrin and its zinc chelate from red blood cells. The recoveries were greater than 90% with coefficients of variation between 8 and 10%. A linear response curve was obtained from 800 to 4000 g/l erythrocytes for the porphyrins.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

8.
9.
A sensitive high-performance liquid chromatographic assay was developed for the determination of tocainide enantiomers in plasma. Following extraction of tocainide from plasma, the enantiomers were derivatized with S-(+)-1-(1-naphthyl)ethylisocyanate. The resulting diastereomers were separated and quantified using normal-phase chromatography with fluorescence detection set at 220/345 nm (excitation/emission). The peaks, resolved with a resolution factor greater than 1.5, were free from interference. Linearity was established over the concentration range 0.25-10.0 mg/l for each enantiomer in plasma (r2 greater than 0.998). The inter-assay variability was less than 10% at all concentrations examined. The method can be used to determine the pharmacokinetics of tocainide enantiomers in man.  相似文献   

10.
Lanin SN  Nikitin YS 《Talanta》1989,36(5):573-579
Normal-phase high-performance liquid chromatography has been used for separation of phenol and its monoderivatives. Multi-component mixtures of hexane (non-polar component) with butan-1-ol, chloroform, butyl bromide, butyl chloride or diethyl ether (polar additives) were used as selective eluents. Silica gel "Silasorb 600" with specific surface area of about 600 m(2)/g and average particle size of $ 10 mum was used as the sorbent. Phenol and the o-, m-, p-isomers of cresol were concentrated by extraction with n-butyl acetate from aqueous solutions. A method for determination of microamounts of phenols in aqueous solutions in the presence of 160-fold amounts of aromatic hydrocarbons has been developed.  相似文献   

11.
12.
13.
The separation of racemic benoxaprofen into the two benoxaprofen enantiomers by preparative high-performance liquid chromatography and the application of the activated enantiomers as derivatization reagents for the simultaneous stereoselective determination of chiral amines in biological material is described. Activated (+)- and (-)-benoxaprofen are both shown to be very sensitive and stable chiral fluorescence markers, applicable to thin-layer chromatography as well as to high-performance liquid chromatography.  相似文献   

14.
Summary Due to manifold physiological and cardioprotective actions of adenosine, the demand for a simple but accurate method to determine its concentration in plasma is increasing. The aim of this study was firstly to develop a simple isocratic method instead of the gradient elution or peak-shifting techniques used earlier and secondly to check conflicting data on the composition of stop-solution, added to the sample in order to prevent changes in adenosine concentration. Isocratic elution improved signal to noise ratio and concentrations of 100 mol L–1 dipyridamole and 2.5 mol L–1 erythro-9(2-hydroxy-3-nonyl)adenine in the blood sample effectively prevented both adenosine formation and degradation, even without the use of a 5-ecto-nucleotidase inhibitor. Lowering the concentration of dipyridamole to 25 mol L–1 caused more than a tenfold increase of adenosine concentration in two out of five cases and even 100 mol L–1 dipyridamole alone is not sufficient to inhibit adenosine deaminase in blood samples.  相似文献   

15.
A high-performance liquid chromatographic method for the determination of pirenzepine in human plasma is reported using imipramine as an internal standard. The assay has a lower limit of detection of 2.5 ng/ml. The calibration function is found to be linear in the range from 5 ng/ml up to at least 100 ng/ml. Two sets of chromatographic conditions are described, which provide different chromatographic selectivities for the separation of the compounds of interest from other material present in a sample.  相似文献   

16.
Two methods for determination of oxolinic acid and flumequine in salmon plasma are described. The first method applies sample pretreatment on C2 disposable solid-phase extraction columns. The second method is based on direct plasma injection and on-line sample clean-up on a polystyrene-divinylbenzene precolumn. After column-switching, the analytes are separated on a polystyrene-divinylbenzene analytical column and detected with a fluorescence detector. Validation of the methods showed good sensitivity, precision and reproducibility. Both methods are well suited for determination of plasma levels of the drugs in pharmacokinetic studies in Atlantic salmon.  相似文献   

17.
18.
Two methods for automated analysis of extracts from edible muscle tissue of Atlantic salmon are described. Oxolinic acid and flumequine are extracted with phosphate buffer pH 9, and the extracts are analysed by high-performance liquid chromatography using a column-switching system. One method applies on-line concentration and clean-up of the extracts on a precolumn packed with polystyrene-divinylbenzene. This method was useful for the analysis of oxolinic acid and flumequine in the microgram/g range. The other method was based on on-line dialysis and concentration of the dialysate on the polymeric precolumn. This method was shown to be a reliable method for residue analysis, and the limit of detection was 2 ng/g for oxolinic acid and 3 ng/g for flumequine with fluorescence detection.  相似文献   

19.
A simple isocratic high-performance liquid chromatographic (HPLC) method for the quantitative analysis of monofluoroacetic acid (MFA), the toxic substance of Dichapetalum cymosum, in plant material, rumen contents (gastric contents), and liver samples is described. A suitable HPLC column that gives optimum sensitivity, accuracy, precision, and separation of MFA is identified. A C-610 organic acid analysis column at ambient temperature with 0.02M H3PO4 as an eluent and ultraviolet detection at 210 nm is utilized to quantitate MFA. Using this method, the average percentage recovery in plant material, bovine liver, and rumen samples is 94.8%, and a detection limit of 12 microg/L is achievable.  相似文献   

20.
High-performance liquid chromatography on a Zorbax C8 7-micron column (25 cm X 0.46 cm I.D.) with methanol-water-1 M phosphoric acid (59:36:5) as the mobile phase has been used for the analysis of several naturally aged batches of fourteen brands of acetylsalicyclic acid tablets. The extraction solvent is methanol, containing 2% v/v of formic acid. Salicylic acid is the main impurity. Acetylsalicylsalicylic acid is the second most important impurity, and the corresponding salicylsalicylic acid is rarely present. Buffered or dispersible tablets contain relatively more of the latter two impurities and eventually also the corresponding higher oligomers. Acetylsalicylic anhydride is always a minor impurity. Comparison is made with classical spectrophotometric methods, which are observed to be selective for salicylic acid.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号