首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Yoon KH  Lee SY  Jang M  Ko SH  Kim W  Park JS  Park I  Kim HJ 《Talanta》2005,66(4):831-836
A simple, fast and sensitive high-performance liquid chromatography (HPLC)-electrospray ionization (ESI) tandem mass spectrometric method (LC-MS/MS) has been developed for determination of propiverine and propiverine N-oxide metabolite in human plasma using oxybutynin as internal standard. Instead of extracting propiverine from plasma using organic solvents, which should be separated from the aqueous phase and evaporated before injecting the sample into the chromatograph, plasma sample containing propiverine and N-oxide was directly injected after precipitating proteins with acetonitrile. Numerous compounds in the plasma did not interfere with the highly specific multiple reaction monitoring in tandem mass spectrometric detection following C8 reversed-phase chromatographic separation under conditions that eluted propiverine, N-oxide and oxybutynin within 2 min (0.1% formic acid in water/acetonitrile, 25:75, v/v). The LC-MS/MS method and an alternative LC-MS method, using methyl-t-butyl ether extraction and selected ion monitoring, were validated over 1-250 ng ml−1 of propiverine and 2 to 500 ng ml−1 of N-oxide, and successfully applied in a pharmacokinetic study. The lower limit of quantitation was 1 ng ml−1 for propiverine and 2 ng ml−1 for N-oxide in both methods.  相似文献   

2.
Bioactive botanicals contain natural compounds with specific biological activity, such as antibacterial, antioxidant, immune stimulating, and taste improving. A full characterization of the chemical composition of these botanicals is frequently necessary. A study of small carbohydrates from the plant materials of 18 bioactive botanicals is further described. The study presents the identification of the carbohydrate using a gas chromatographic‐mass spectrometric analysis that allows detection of molecules as large as maltotetraose, after changing them into trimethylsilyl derivatives. A number of carbohydrates in the plant (fructose, glucose, mannose, sucrose, maltose, xylose, sorbitol, and myo‐, chiro‐, and scyllo‐inositols) were quantitated using a novel liquid chromatography with tandem mass spectrometric technique. Both techniques involved new method developments. The gas chromatography with mass spectrometric analysis involved derivatization and separation on a Rxi®‐5Sil MS column with H2 as a carrier gas. The liquid chromatographic separation was obtained using a hydrophilic interaction type column, YMC‐PAC Polyamine II. The tandem mass spectrometer used an electrospray ionization source in multiple reaction monitoring positive ion mode with the detection of the adducts of the carbohydrates with Cs+ ions. The validated quantitative procedure showed excellent precision and accuracy allowing the analysis in a wide range of concentrations of the analytes.  相似文献   

3.
A fast, sensitive and specific method for routine determination of residues from Chlormequat (CAS no. 7003-89-6) is described. The method is based on a simple clean-up using an SPE-C18 cartridge, high-performance liquid chromatography on a standard C18 column (Spherisorb S5 ODS1) and specific detection and quantification by electrospray mass spectrometry (LC-MS/MS). 13C-Chlormequat was synthesised for use as internal standard. Samples were extracted with methanol – water – acetic acid. Internal standard and ammonium acetate were added before C18-cartridge clean up and residues eluted with methanol – water – acetic acid, containing 50 mM ammonium acetate. Chromatographic separation was achieved using a solvent composed of acetonitrile – methanol – water – acetic acid (53:21:25:1 by volume), containing 50 mM ammonium acetate. Electrospray ionisation mass spectrometry was employed using m/z 58 (daughter ion of the Chlormequat quaternary ammonium ion, m/z 122) and m/z 61 (daughter ion of the 13C-Chlormequat quaternary ammonium ion, m/z 125) for quantification. The LC analysis time was 15 min and the limit of detection of the analytical method was 9 μg/kg. The performance of the method was demonstrated analysing grain material from an inter-comparison study. In Denmark the primary use of Chlormequat chloride (CCC, cycocel, or chlorocholin chloride, CAS no. 999-81-5) is for winter cereals and 11 such winter wheat samples from the Danish National Pesticide Survey were analysed. Residue contents were from below 0.01 up to 0.45 mg/kg, and thus below the EU maximum residue level of 2.0 mg/kg for wheat.  相似文献   

4.
Heon-Woo Lee 《Talanta》2007,71(1):62-67
A simple, rapid, and sensitive high-performance liquid chromatography (HPLC)-electrospray ionization (ESI) tandem mass spectrometric method (LC-MS/MS) has been developed for simultaneous determination of cilazapril levels and its active metabolite, cilazaprilat, in human plasma using enalapril as internal standard. The acquisition was performed in the multiple reaction monitoring mode; monitoring the transitions: m/z 418.4 > 211.1 for cilazapril and m/z 390.3 > 211.1 for cilazaprilat. The method involves a simple single-step liquid-liquid extraction with ethyl acetate. The analyte was chromatographed on an YMC C8 reversed-phase chromatographic column by isocratic elution with 10 mM ammonium formate buffer-methanol (10:90, v/v; pH 3.2 with formic acid). Numerous compounds did not interfere with specific multiple reaction monitoring in tandem mass spectrometric detection following C8 reversed-phase chromatographic separation under conditions that eluted cilazapril, cilazaprilat, and enalapril within 2 min. This method was validated over 0.1-500 ng ml−1 of cilazapril and 0.5-50 ng ml−1 of cilazaprilat. Cilazapril and cilazaprilat were stable in standard solution and in plasma samples under typical storage and processing conditions. The assay was successfully applied to a pharmacokinetic study of cilazapril given as a single oral dose (5 mg) to healthy volunteers.  相似文献   

5.
A simple method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of itopride in human plasma, using sulpiride as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 359.5 > 166.1 for itopride and m/z 342.3 > 111.6 for IS, respectively. Analytes were chromatographed on an YMC C18 reverse-phase chromatographic column by isocratic elution with 1 mM ammonium acetate buffer-methanol (20: 80, v/v; pH 4.0 adjusted with acetic acid). Results were linear (r2 = 0.9999) over the studied range (0.5-1000 ng mL−1) with a total analysis time per run of 2 min for LC-MS/MS. The developed method was validated and successfully applied to bioequivalence studies of itopride hydrochloride in healthy male volunteers.  相似文献   

6.
A sensitive liquid chromatographic–electrospray ionization–mass spectrometric (LC–MS) method has been developed for direct measurement of the concentration of tiopronin in human plasma. Hydrochloric acid solution was used to stabilize the tiopronin and prevent formation of a dimer, or reaction with endogenous thiols. The method involved liquid–liquid extraction of tiopronin from plasma samples with ethyl acetate, simple reversed-phase chromatography, and mass spectrometric detection with nanogram detection limits. Acetaminophen was used as internal standard (IS). The limit of quantification was 5 ng mL?1 (RSD 4.3%). The method was validated within the linear range 5–500 ng mL?1. The correlation coefficient for the calibration regression line was 0.9997 or better. Intra-day and inter-day accuracy were better than 15%. The method has been successfully used for a pharmacokinetic study with human subjects. Among the pharmacokinetic data obtained, t 1/2 was 2.37 ± 0.63 h and T max was 4 h.  相似文献   

7.
A rapid, sensitive and specific method using liquid chromatography with tandem mass spectrometric detection (LC‐MS) was developed for the analysis of sauchinone in rat plasma. Di‐O‐methyltetrahydrofuriguaiacin B was used as internal standard (IS). Analytes were extracted from rat plasma by liquid–liquid extraction using ethyl acetate. A 2.1 mm i.d. × 150 mm, 5 µm, Agilent Zorbax SB‐C18 column was used to perform the chromatographic analysis. The mobile phase was methanol–deionized water (80:20, v/v). The chromatographic run time was 7 min per injection and the flow‐rate was 0.2 mL/min. The tandem mass spectrometric detection mode was achieved with electrospray ionization interface in positive‐ion mode (ESI+). The m/z ratios [M + Na]+, m/z 379.4 for sauchinone and m/z 395.4 for IS were recorded simultaneously. Calibration curve were linear over the range of 0.01–5 µg/mL. The lowest limit of quantification was 0.01 µg/mL. The intra‐day and inter‐day precision and accuracy of the quality control samples were 2.94–9.42% and 95.79–108.05%, respectively. The matrix effect was 64.20–67.34% and the extraction recovery was 93.28–95.98%. This method was simple and sensitive enough to be used in pharmacokinetic research for determination of sauchinone in rat plasma. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

8.
A convenient and versatile method was developed for the separation and detection of alkaline earth metal ions by ion chromatography with indirect UV detection. The chromatographic separation of Mg2+, Ca2+, and Sr2+ was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid as the mobile phase, in which the imidazolium ionic liquid acted as an UV‐absorption reagent. The effects of imidazolium ionic liquids, detection wavelength, acids in the mobile phase, and column temperature on the retention of Mg2+, Ca2+, and Sr2+ were investigated. The main factors influencing the separation and detection were the background UV absorption reagent and the concentration of hydrogen ion in ion chromatography with indirect UV detection. The successful separation and detection of Mg2+, Ca2+, and Sr2+ within 14 min were achieved using the selected chromatographic conditions, and the detection limits (S /N = 3) were 0.06, 0.12, and 0.23 mg/L, respectively. A new separation and detection method of alkaline earth metal ions by ion chromatography with indirect UV detection was developed, and the application range of ionic liquids was expanded.  相似文献   

9.
Triterpenoid saponins are difficult to analyze using high‐performance liquid chromatography coupled to UV/vis spectrophotometry due to their lack of chromophores. This study describes the first analytical method for the determination of 15 triterpenoid saponins from the leaves, stems, root bark, and fruits of Acanthopanax henryi, using a high‐performance liquid chromatography with charged aerosol detection coupled with electrospray ionization mass spectrometry method. The separation was carried out on a Kinetex XB‐C18 column with an acetonitrile/water gradient as the mobile phase, followed by charged aerosol detection. The operating conditions of charged aerosol detection were set at 24 kPa for nitrogen pressure and 100 pA for the detection range. Liquid chromatography with electrospray ionization mass spectrometry is described for the identification of compounds in plant samples. The electrospray ionization mass spectrometry method involved the use of the [M + Na]+ and [M + NH4]+ ions for compounds 1 – 15 in the positive ion mode with an extracted ion chromatogram. The developed method was fully validated in terms of linearity, sensitivity, precision, repeatability, and recovery, then subsequently applied to evaluate the quality of A. henryi.  相似文献   

10.
The accurate and precise measurement of endogenous corticosteroids in urine is a powerful tool to understand the biochemical state in several diseases. In this study, a rapid, accurate, and sensitive method based on liquid chromatography-tandem mass spectrometry (LC–MS/MS) for the quantification of 67 endogenous gluco- and mineralo-corticosteroids and progestins has been developed and validated. Sample preparation, chromatographic separation, and mass spectrometric detection were optimized. Urine samples (0.5 mL) were hydrolyzed with β-glucuronidase and the released analytes were extracted by liquid–liquid extraction. The chromatographic separation was performed in 20 min after redisolution of the extract. MS behavior of endogenous corticosteroids was evaluated in order to select the most specific precursor ion ([M+H]+, [M+NH4]+, or [M+H-nH2O]+) for the detection. MS/MS determination was performed under selected reaction monitoring mode using electrospray ionization in positive mode. The method was shown to be linear (r > 0.99) in the range of endogenous concentrations for all studied metabolites. Limits of detection (LOD) below 1 ng mL−1 were typically obtained for analytes with a 3-oxo-4-ene structure whereas LODs below 15 ng mL−1 were common for the rest of analytes. Recoveries were higher than 80% and intra-assay precisions below 20%, evaluated at three concentration levels, were found for most steroids. No significant or moderate matrix effect, ranging from 54 to 155%, was observed for most of the analytes. The applicability of the method was confirmed by analyzing 24 h urine samples collected from twenty healthy volunteers and comparing the results with previously established normal ranges. The wide coverage of corticosteroid metabolism, together with short analysis time, low sample volume, simple sample preparation, and satisfactory quantitative results make this method useful for clinical purposes.  相似文献   

11.
Indirect ultraviolet detection was conducted in ultraviolet‐absorption‐agent‐added mobile phase to complete the detection of the absence of ultraviolet absorption functional group in analytes. Compared with precolumn derivatization or postcolumn derivatization, this method can be widely used, has the advantages of simple operation and good linear relationship. Chromatographic separation of Li+, Na+, K+, and NH4+ was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid/organic solvent as the mobile phase, in which imidazolium ionic liquids acted as ultraviolet absorption reagent and eluting agent. The retention behaviors of four kinds of cations are discussed, and the mechanism of separation and detection are described. The main factors influencing the separation and detection were the background ultraviolet absorption reagent and the concentration of hydrogen ion in the ion chromatography‐indirect ultraviolet detection. The successful separation and detection of Li+, Na+, K+, and NH4+ within 13 min was achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.02, 0.11, 0.30, and 0.06 mg/L, respectively. A new separation and analysis method of alkali metal ions and ammonium by ion chromatography with indirect ultraviolet detection method was developed, and the application range of ionic liquid was expanded.  相似文献   

12.
In this study, a stability‐indicating reversed‐phase liquid chromatographic electrospray mass spectrometric method was developed and validated for the determination of process‐related impurities and forced degradants of Efavirenz in bulk drugs. Efavirenz was subjected to acid, alkaline hydrolysis, H2O2 oxidation, photolysis, and thermal stress. Significant degradation was observed during alkaline hydrolysis, and the degradants were isolated on a mass‐based purification system and characterized by high‐resolution mass spectrometry, positive electrospray ionization tandem mass spectrometry, and 1H and 13C NMR spectroscopy. Accurate mass measurement and NMR spectroscopy revealed the possible structure of process‐related impurities and degradant under stress conditions. The acceptable separation was accomplished on Waters bondapak C18 column (250 mm × 4.6 mm; 5 μm), using 5 mM ammonium acetate and acetonitrile as a mobile phase in a gradient elution mode at a flow rate of 1.0 mL/min. The eluents were monitored by diode array detector at 247 nm and quantitation limits were obtained in the range of 0.1–2.5 μg/mL for Efavirenz, degradants, and process‐related impurities. The liquid chromatography method was validated with respect to accuracy, precision, linearity, robustness, and limits of detection and quantification as per International Conference on Harmonization guidelines.  相似文献   

13.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of amlodipine in human plasma. Amlodipine was extracted from human plasma by using a solid-phase extraction technique. Imipramine was used as the internal standard. A Hypersil BDS C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The method involves a rapid solid-phase extraction from plasma, simple isocratic chromatography conditions and mass spectrometric detection that enables detection at sub-nanogram levels. The proposed method has been validated for a linear range of 0.1-10.0 ng/mL with correlation coefficient >or=0.9990. The intrarun and interrun precision and accuracy were within 10.0%. The overall recovery for amlodipine was 63.67%. Total run time was 3.2 min only.  相似文献   

14.
Xin Hu  Yun-Feng Lv  Kai-Shun Bi 《Chromatographia》2009,69(9-10):1073-1076
A rapid and simple high-performance liquid chromatographic tandem mass spectrometric method has been developed and validated for analysis of strictosamide in rat plasma. Chromatographic separation was achieved on a C18 column by gradient elution with mixtures of methanol, water, and acetonitrile containing 0.05% acetic acid. Digoxin was used as internal standard. Selected reaction monitoring (SRM) was used for MS quantitation. Linearity was good in the range 0.05–20 ng mL?1 in rat plasma. The lower limit of quantitation was 0.04 ng mL?1. The method is precise and reliable and can be applied to pharmacokinetic studies.  相似文献   

15.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of nicorandil in human plasma. Nicorandil was extracted from human plasma using solid-phase extraction technique. Imipramine was used as the internal standard. A Betasil C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The method involves a rapid solid-phase extraction from plasma, simple isocratic chromatography conditions and mass spectrometric detection that enables detection at nanogram levels. The proposed method has been validated for a linear range of 1.0-500.0 ng/mL with a correlation coefficient of > or =0.9993. The intra-run and inter-run precision and accuracy was within 10.0%. The overall recovery for nicorandil was 63.81%. The total run time was just 3.0 min.  相似文献   

16.
A liquid chromatography–tandem mass spectrometry method is proposed for the simultaneous determination of 1,1-dimethylhydrazine, methylhydrazine, N,N-dimethylformamide, 1-methyl-1H-1,2,4-triazole, dimethylguanidine, N-nitrosodimethylamine and 1,1,4,4-tetramethyltetrazene, important rocket fuel pollutants of soils. Chromatographic separation was conducted according to previously published results in an isocratic mode on an analytical column with a Nucleosil-100–5SA sulfo-cation-exchanger. The mobile phase composition was optimised in order to achieve effective separation of all analytes and provide high sensitivity of mass spectrometric detection – an ammonium acetate buffer solution (50 mM, pH 5.4) containing methanol (25%) was used. Detection was performed in the positive electrospray ionisation mode with multiple reaction monitoring (MRM). The parameters of ion source, ion optics, the inlet potentials of the quadrupoles and the collision energy for the detection of the found product ions were optimised. Calibration dependences for all compounds are linear in wide concentration ranges, covering 3–4 orders of magnitude. The detection limits vary from 40 pg mL?1 for dimethylguanidine to 18 ng mL?1 for methylhydrazine. No significant matrix effects were observed in the analysis of acid peaty soil extracts. The method was validated and successfully used to analyse a real soil sample collected at the place of impact of the first stage of a carrier rocket.  相似文献   

17.
Chromatography on Attapulgus clay and on silicic acid has been used to isolate ‘neutral’ and ‘basic’ nitrogen fractions from the 650–1050 °F distillate of an off-shore Californian crude oil. These polar compounds were subjected to on-line liquid chromatography – mass spectrometric (LC-MS) analysis using low voltage electron-impact ionization high resolution mass spectrometry (LVEI HRMS) and deuterated ammonia chemical ionization (ND3 Cl) to determine the molecules' elemental composition and number of exchangeable hydrogen atoms. On-line separation of heavy oils into saturated, 1–4 ring aromatic, and polar compounds was performed by normal phase high performance liquid chromatography (HPLC) on a dinitroanilinopropyl (DNAP) silica column.  相似文献   

18.
《Analytical letters》2012,45(14):2157-2169
Abstract

A rapid, sensitive, and specific liquid chromatography–tandem mass spectrometric (HPLC-MS/MS) method has been developed for quantification of ferulic acid in rat plasma. The analyte and docetaxel (internal standard) were extracted from plasma samples with diethyl ether and analyzed on a C18 column. The chromatographic separation was achieved within 3.5 min by using acetonitrile-water as the mobile phase and the flow rate was 0.2 mL · min?1. The method was linear within the range of 0.5 ? 800 ng · mL?1. The lower limit of quantification (LLOQ) was 0.5 ng · mL?1. Finally, the method is successfully applied for the pharmacokinetic study of ferulic acid in rats following intravenous administration.  相似文献   

19.
A simple, sensitive and rapid assay method has been developed and validated as per regulatory guidelines for the estimation of enasidenib on mouse dried blood spots (DBS) using liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The method employs liquid extraction of enasidenib from DBS disks of mouse whole blood followed by chromatographic separation using 0.2% formic acid–acetonitrile (25:75, v/v) at a flow rate of 1.0 mL/min on an Atlantis dC18 column with a total run time of 2.0 min. The MS/MS ion transitions monitored were m/z 474.0 → 267.1 for enasidenib and m/z 309.2 → 251.3 for the internal standard (warfarin). The assay was linear in the range of 1.01 – 3044 ng/mL. The within‐run and between‐run precisions were in the range of 3.18 – 9.06 and 4.66 – 8.69%, respectively. Stability studies showed that enasidenib was stable on DBS cards for 1 month. This novel method has been applied to analyze the DBS samples of enasidenib obtained from a pharmacokinetic study in mice.  相似文献   

20.
A new liquid chromatographic tandem mass spectrometric method for the determination of mirtazapine and demethylmirtazapine in human plasma has been developed and fully validated. The article describes in detail the bioanalytical procedure and summarizes the validation results obtained. The samples were extracted using liquid-liquid extraction with a mixture of 1-chlorobutane/isopropanol/ethyl acetate (88:2:10, (v/v/v)). The chromatographic separation was performed on a reversed-phase XTerrra MS C8 column ( i.d.; 3.5 μm particle size) using a mobile phase consisting of 0.010 M ammonium formate (pH 7.8) and acetonitrile (35:65, (v/v)), pumped at a flow rate of 0.80 ml min−1. The analytes were detected using a Finnigan LCQ advantage ion-trap mass spectrometer with positive electrospray ionization in selected reaction monitoring (SRM) mode. Tandem mass spectrometric detection enabled the quantitation of both compounds down to 0.10 ng ml−1. Calibration graphs were linear (r better than 0.990, n=11), in concentration ranges 0.10 to 200 ng ml−1 for mirtazapine demethylmirtazapine. The intra- and inter-day R.S.D. values were less than 14.8 and 16.6% for mirtazapine and demethylmirtazapine, respectively. The method was successfully applied to a kinetic study in order to assess the main pharmacokinetic parameters of mirtazapine and demethylmirtazapine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号