首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
The objective of this research was to apply Fourier transform infrared spectroscopy (FTIR) and tunable infrared laser differential absorption spectroscopy (TILDAS) for measuring selected gaseous constituents in mainstream (MS) and sidestream (SS) smoke for experimental cigarettes designed to reduce MS CO using iron oxide cigarette papers. These two complimentary analytical techniques are well suited for providing per puff smoke deliveries and intra-puff evolution profiles in cigarette smoke respectively. The quad quantum cascade (QC) laser high resolution infrared spectroscopy system has the necessary temporal and spectral resolution and whole smoke analysis capabilities to provide detailed information for CO and CO(2) as they are being formed in both MS and SS smoke. The QC laser system has an optimal data rate of 20 Hz and a unique puffing system, with a square wave shaped puff, that allows whole smoke to enter an 18 m, 0.3 L multi-pass gas cell in real time (0.1s cell response time) requiring no syringe or Cambridge filter pad. Another similar multi-pass gas cell with a 36 m pathlength simultaneously monitors the sidestream cigarette smoke. The smoke from experimental cigarettes manufactured with two types of iron oxide papers were compared to the smoke from cigarettes manufactured similarly without iron oxide in the paper using both instrument systems. The delivery per puff determined by the QC laser method agreed with FTIR results. MS CO intra-puff evolution profiles for iron oxide prototype cigarettes demonstrated CO reduction when compared to cigarettes without iron oxide paper. Additionally, both CO and CO(2) intra-puff evolution profiles of the cigarettes with iron oxide paper showed a significant reduction at the initial portion of the 2 s puff not observed in the non-iron oxide prototype cigarettes. This effect also was observed for ammonia and ethylene, suggesting that physical parameters such as paper porosity and burn rate are important. The SS CO and CO(2) deliveries for the experimental cigarettes evaluated remained unaffected. The iron oxide paper technology remains under development and continues to be evaluated.  相似文献   

2.
Soft single-photon ionisation (SPI)–time-of-flight mass spectrometry (TOFMS) has been used to investigate the effect of different cigarette-lighting devices on the chemical composition of the mainstream smoke from the first cigarette puff. Lighting devices examined were a Borgwaldt electric lighter, a propane/butane gas lighter, a match, a candle, and the burning zone of another cigarette. To eliminate the effects of the different masses of tobacco burnt by use of the different lighting methods a normalisation procedure was performed which enabled investigation of changes in the chemical patterns of the resulting smoke. When another cigarette was used as the lighting device, elevated levels of ammonia and other nitrogen-containing substances were observed. These are high in the sidestream smoke of the cigarette used for lighting and would be drawn into the mainstream smoke of the cigarette being lit. In contrast, smoke from the cigarette lit by the electric lighter contained slightly higher normalised amounts of isoprene. Lighting the cigarette by use of a candle resulted in larger amounts of substances, e.g. benzene, which most probably originated from thermal decomposition of wax. The composition of the first puff of smoke obtained by use of the three lighting methods with open flames (gas lighter, match, and candle) was usually similar whereas the composition of the smoke produced by use of the electric lighter and the cigarette as the lighter were more unique. The chemical patterns generated by the different lighting devices could, however, be separated by principal-component analyses. Two additional test series were also studied. In the first the cigarette was lit with an electric lighter, then extinguished, the ash was cut off, and the cigarette was re-lit. In the second the cigarette was heated in an oven to 80 °C for 5 min before being lit. These treatments did not result in changes in the chemical composition compared with cigarettes lit in the ordinary way. Figure Time-of-flight mass spectrometry (TOFMS) has been used to investigate the effect of different cigarette-lighting devices on the chemical composition of the mainstream smoke from the first cigarette puff  相似文献   

3.
一种测定主流卷烟烟气中固相自由基总量的新方法   总被引:1,自引:0,他引:1  
研究了一种准确测定主流卷烟烟气中固相自由基总量的新方法. 通常人们采用剑桥滤片来捕集主流卷烟烟气中的固相自由基, 但它并不适合用于准确测定主流卷烟烟气中的固相自由基的总量, 研究发现有超过20%的主流卷烟烟气中的固相自由基可以透过剑桥滤片. 找到了一种电子顺磁共振波谱(EPR)信号很小的、适合用来捕集主流卷烟烟气中的固相自由基总量的过滤片. 采用了以在相同条件下测得的1,1-二苯基-2-苦基肼基(1,1-Diphenyl-2-picryl-hydrazyl, 简称DPPH)的EPR信号强度与强煤的EPR信号强度相比得到的相对EPR信号强度与自由基的自旋数建立校准曲线的方法来计算烟气固相自由基的量, 降低了使用不同的电子自旋共振波谱仪造成的对同一种检测样品测定结果的差异. 通过不同实验室内和实验室间的验证实验, 证明了此方法有很好的重复性和重现性.  相似文献   

4.
建立了一种固相萃取-超高效液相色谱法(SPE-UPLC)快速检测主流烟气中丙烯酰胺的方法。使用剑桥滤片和吸收瓶捕集主流烟气后,蒸馏水做萃取溶剂,采用C18固相萃取小柱对样品液进行纯化,用UPLC检测,外标法定量。UPLC方法采用ACQUITY UPLCTMBEH C181.7μm 2.1×50 mm色谱柱,柱温30℃,流动相为V(乙腈)∶V(水)=6∶94,流速为0.15 mL/min,紫外检测器(TUV)检测波长为202 nm,分析时间为6 min。烤烟型香烟主流烟气中丙烯酰胺的含量为4.75μg/cig。方法的线性范围为0.1~10 mg/mL,线性相关系数为0.9999;平均回收率为98.7%;检出限为10 ng/mL(S/N=3);相对标准偏差为2.3%。该方法适合主流烟气中丙烯酰胺的快速检测。  相似文献   

5.
Bian Z  Tang G  Chen Z  Pang Y  Jiang X  Hu Q 《色谱》2011,29(10):1031-1035
以全自动固相萃取技术净化主流烟气萃取液,建立了卷烟主流烟气中苯并[a]芘、苯并[a]蒽和屈艹 3种多环芳烃的气相色谱-串联质谱(GC-MS/MS)测定方法。以吸烟机抽吸卷烟,并以剑桥滤片捕集卷烟主流烟气,然后以含氘代苯并[a]芘内标的环己烷溶液萃取滤片,萃取液经全自动固相萃取仪净化后以GC-MS/MS分离检测。结果表明,苯并[a]芘、苯并[a]蒽和屈艹 的检出限分别为0.05、0.16和0.23 ng/cig,回收率为91.5%~102.1%,相对标准偏差(RSD)均小于5%。该方法的自动化程度高、操作简便、检出限低、重复性好,适用于卷烟主流烟气中苯并[a]芘、苯并[a]蒽 3种多环芳烃释放量的检测。  相似文献   

6.
Acrolein and 1,3-butadiene in cigarette smoke generally are measured using two separate analytical methods, a carbonyl derivative HPLC method for acrolein and a volatile organic compound (VOC) GC/MS method for 1,3-butadiene. However, a single analytical method having improved sensitivity and real-time per puff measurement will offer more specific information for evaluating experimental carbon filtered cigarettes designed to reduce the smoke deliveries of these constituents. This paper describes an infrared technique using two lead-salt tunable diode lasers (TDLs) operating with liquid nitrogen cooling with emissions at 958.8 cm(-1) and 891.0 cm(-1) respectively for the simultaneous measurement of acrolein and 1,3-butadiene, respectively, in each puff of mainstream cigarette smoke in real time. The dual TDL system uses a 3.1l volume, 100 m astigmatic multiple pass absorption gas cell. Quantitation is based on a spectral fit that uses previously determined infrared molecular line parameters generated in our laboratory, including line positions, line strengths and nitrogen-broadened half-widths for these species. Since acrolein and ethylene absorption lines overlap and 1,3-butadiene, ethylene and propylene absorption lines overlap, the per puff deliveries of ethylene and propylene were determined since their overlapping absorption lines must be taken into account by the spectral fit. The acrolein and 1,3-butadiene total cigarette deliveries for the 1R5F Kentucky Reference cigarette were in agreement with the HPLC and GC/MS methods, respectively. The limit of detection (LOD) for 1,3-butadiene and acrolein was 4 ng/puff and 24 ng/puff, respectively, which is more than adequate to determine at which puff they break through the carbon filter. The retention and breakthrough behavior for the two primary smoke constituents depend on the cigarette design and characteristics of the carbon filter being evaluated.  相似文献   

7.
Tobacco‐specific nitrosamines are one of the most important groups of carcinogens in tobacco products. Using adsorbents as filter additives is an effective way to reduce tobacco‐specific nitrosamines in cigarette smoke. Molecularly imprinted polymers (MIPs) using nicotinamide as template were grafted on the silica gel surface to obtain MIP@SiO2 and employed as filter additives to absorb tobacco‐specific nitrosamines in mainstream cigarette smoke. Four milligrams of MIP@SiO2 per cigarette was added to the interface between filter and tobacco rod to prepare a binary filter system. The mainstream smoke was collected on an industry‐standard Cambridge filter pad and extracted with ammonium acetate aqueous solution before analysis. Compared to the cigarette smoke of the control group, the levels of tobacco‐specific nitrosamines with silica gel and with MIP@SiO2 were both reduced, and the adsorption rates of N‐nitrosonornicotine, N‐nitrosoanabasine, N‐nitrosoanatabine, and 4‐(methylnitrosamino)‐1‐(3‐pyridine)‐1‐butanone with silica gel and with MIP@SiO2 were 20.76, 15.32, 18.79, and 18.01%, and 41.33, 34.04, 37.86, and 35.53%, respectively. Furthermore the content of total particle materials in cigarette smoke with silica gel was decreased evidently but showed no observable change with MIP@SiO2. It indicated MIP@SiO2 could selectively reduce tobacco‐specific nitrosamines in the mainstream cigarette smoke with no change to the cigarette flavor.  相似文献   

8.
建立了在线液相-气相二维色谱测定卷烟主流烟气中4-(N-甲基亚硝胺基)-1-(3-吡啶基)-1-丁酮(NNK)的方法。 NNK 的分析在在线凝胶气质联用仪上进行,采用自行装填的微型碱性氧化铝柱,并把仪器上的凝胶柱换成氧化铝柱,用于 NNK 的分析。捕集有主流烟气总粒相物的剑桥滤片用二氯甲烷提取,以 D4-NNK 为内标,提取液经微型氧化铝柱分离,含 NNK 的部位切割进入气相色谱,排干溶剂后启动气相色谱升温经毛细管柱进行分离,用质谱检测。本方法将烟气国标方法 NNK 测定中的氧化铝柱色谱净化和气相色谱-质谱分析在线连接起来,可不经样品前处理净化直接进样分析;每次进样可达40μL,是常规气相色谱-质谱分析最大进样量(2.0μL)的20倍,显著提高了分析灵敏度。方法线性范围达1.2~120 ng/ mL,相关系数为r=0.9998,回收率为93.9%~96.0%;检出限和定量限分别为0.25 ng/ mL 和0.9 ng/ mL,样品分析结果与中国烟草总公司企业标准方法进行对比,结果相符合。  相似文献   

9.
A sampling system has been set up to monitor a group of volatile smoke analytes (nitric oxide, acetaldehyde, acetone, benzene, toluene, 1,3 butadiene, isoprene and carbon dioxide) from mainstream cigarette smoke on a puff-resolved basis. The system was able to record gas evolution profiles during puffing and interpuff periods without interruption (e.g. taking clearing puffs). Gas phase smoke analytes were sampled as close to the mouth end of the cigarette filter as possible in order to minimise any dead volume effect. The results revealed that, for some volatile species, a significant fraction (e.g. up to 30% for benzene) in the cigarette mainstream smoke had been generated during the preceding smoulder period. These species were trapped or absorbed within the cigarette rod and then subsequently eluted during the puff. The identification of the two sources of the mainstream smoke, a smouldering source and a puffing source, has not been reported before. The observation contributes to the fundamental knowledge of the cigarette smoke formation and may have implications on wider smoke chemistry and associated effects.  相似文献   

10.
Polycyclic aromatic hydrocarbons (PAHs), phenols and aromatic amines can be analyzed in particulate phase mainstream cigarette smoke using simultaneous distillation and extraction (SDE) as a unique sample clean-up step. All analytes are determined from the same smoke sample using GC-MS. The smoke from 20 cigarettes is collected on a Cambridge smoke pad where a mixture of internal standards is added. The Cambridge smoke pad is extracted in a SDE apparatus using water-CH2Cl2. The SDE extract is analyzed directly for PAHs, for phenols after silylation, and for amines after derivatization with heptafluorobutyric anhydride. Excellent results in agreement with data reported in the literature are obtained by this procedure.  相似文献   

11.
黄云  王裔耿  缪明明  赵琦华  杨光宇 《色谱》2007,25(2):230-233
选择2,4-二硝基苯肼(DNPH)为羰基化合物的衍生化试剂,建立了快速分离柱高效液相色谱测定卷烟主流烟气中8种羰基化合物的方法。采用经2,4-二硝基苯肼酸性溶液处理过的剑桥滤片捕集烟气,再用含2%(体积分数)吡啶的乙腈溶液进行萃取,以ZORBAX Stable Bound色谱柱(50 mm×4.6 mm,1.8 μm)进行快速分离,最后由二极管阵列检测器于365 nm下进行检测。该方法的回收率为89.1%~99.2%,相对标准偏差(RSD)在6.0%以下。该方法分析时间短,流动相消耗少,且操作简便、重复性好、回收率高。  相似文献   

12.
侯宏卫  熊巍  唐纲岭  胡清源 《色谱》2010,28(8):754-758
N-亚硝基降烟碱(NNN)、4-(亚硝基甲氨基)-1-(3-吡啶基)-1-丁酮(NNK)、N-亚硝基新烟草碱 (NAT)和N-亚硝基假木贼碱(NAB)是4种广泛存在于烟草和烟气中的致癌物,准确测定其含量对评估其对人体健康的影响有着重要的作用。采用液相色谱-电喷雾串联质谱(LC-ESI MS/MS)技术建立了卷烟主流烟气中NNN、NNK、NAT和NAB的测定方法,并将其用于中国烤烟和混合型卷烟主流烟气的分析。卷烟主流烟气通过剑桥滤片捕集,捕集烟气后的滤片在加入100 μL氘代混合内标后用10 mL 100 mmol/L醋酸铵水溶液萃取,萃取液过水相滤膜后直接进行LC-ESI MS/MS检测。选用Agilent Zorbax Eclipse XDB-C18色谱柱,以流动相0.1%(v/v)乙酸水溶液和0.1%(v/v)乙酸甲醇溶液梯度洗脱,质谱检测采用正离子扫描,多反应监测模式。NNN、NNK、NAT和NAB的检出限分别为0.019、0.002、0.008和0.007 μg/L,回收率为84.9%~104.5%,相对标准偏差(n=8)为2.96%~6.65%。该方法的检出限低,特异性好,适用于卷烟主流烟气中NNN、NNK、NAT和NAB释放量的检测。  相似文献   

13.
The levels of 2-amino-9H-pyrido[2,3-b]indole (AalphaC or 2-amino-alpha-carboline), 2-amino-3-methyl-9H-pyrido[2,3-b]indole (MeAalphaC or 2-amino-3-methyl-alpha-carboline), 9H-pyrido[3,4-b]indole (norharman), and 1-methyl-pyrido[3,4-b]indole (harman) have been determined in the mainstream smoke condensate from three reference cigarettes, namely Kentucky reference 1R5F, Kentucky reference 2R4F, and CORESTA CM4. The amino-alpha-carbolines, and norharman and harman (beta-carbolines) can be classified as heterocyclic aromatic amines (HAAs) and are listed as biologically active agents in the mainstream smoke of cigarettes. For the analysis, the mainstream smoke condensate from cigarettes was collected on a filter pad, the analytes were isolated using solid-phase extraction (SPE), and quantified without derivatization on a GC-MS. Total amounts of carbolines found in the condensate increased from ultralight 1R5F to full-flavor CM4 cigarettes. The level of harman was about 250 ng/cigarette for the 1R5F cigarette and about 1025 ng/cigarette for the CM4 cigarette. Norharman was typically three times more abundant than harman. The AalphaC was found at about 10 times lower level compared to harman, and MeAalphaC was about 50 times lower than harman. The use of reference cigarettes can provide a common measure for laboratories to assess carboline amounts among cigarette brands.  相似文献   

14.
A method coupling liquid-phase microextraction with matrix-assisted laser desorption/ionization Fourier transform mass spectrometry (LPME/MALDI-FTMS) was developed to measure the content of nicotine in mainstream smoke at the single puff level. Glycerol was utilized as a matrix additive in the sample preparation to improve the homogeneity of analyte distribution in a sample spot. Good repeatability of the MALDI-MS signal (RSD <9%) was achieved by the method. Selective LPME facilitated the separation and purification of basic components from cigarette smoke. The LPME device was coupled to a smoking machine, and each puff of one cigarette could be gathered by this modified machine. The amount of nicotine in the mainstream smoke was measured at the single puff level by LPME/MALDI-FTMS. The method was simple and selective and was sufficiently sensitive to detect nicotine in each puff of one cigarette. The method thus offered an alternative approach to the study of the formation mechanism of cigarette smoke constituents.  相似文献   

15.
An ultra‐high‐pressure liquid chromatography/MS3 (UPLC‐MS3) method has been developed and validated for the quantitative determination of four major TSNAs in mainstream cigarette smoke using MS3 scan mode on a hybrid triple quadrupole‐linear ion trap mass spectrometer. The new method combining the UPLC with MS3 scan mode offers decreased sample analysis time and good selectivity. After mainstream cigarette smoke was collected on a Cambridge filter pad, the particulate matter was extracted with ammonium acetate solution and analyzed by UPLC‐MS3 using isotopically labeled analogues as internal standards. Four TSNAs were completely separated on an Agilent XDB‐C18 UPLC column using isocratic elution during a 6 min LC run time. Excellent linearity was obtained over the concentration range of 1.0‐150.0 ng/mL for all TSNAs with values for correlation coefficient (r) between 0.9985‐0.9994. Limits of detection (LOD) of each TSNA varied from 0.023 to 0.067 ng/mL, and lower limits of quantification (LLOQ) varied from 0.077 to 0.223 ng/mL, respctively. The recovery of each TSNA was from 89.2 to 106.8%. The method achieved excellent reproducibility with RSD 2.1‐6.8% for intra‐assay and 3.4‐9.1% for inter‐assay. This method can be used as an effective approach to significantly improve the detection capability for TSNAs in complex matrices.  相似文献   

16.
A heated injection system for a microprocessor-controlled GC has been developed for the (GC)2 analysis of the volatile phase of whole smoke of a cigarette. Effects of injection port temperature and the presence of a Cambridge filter pad are demonstrated. Chromatograms are shown for smoke samples with and without a Cambridge Filter with the sample valve oven at 25°, 165° and 205°C. The use of a flame ionization and a nitrogen-phosphorous detector is illustrated.  相似文献   

17.
史佳沁  刘百战  谢雯燕 《色谱》2010,28(6):623-627
对多维气相色谱的核心部件中点限流器进行了改进,用一段0.25mm i.d.毛细管柱取代石墨限流管,Y形玻璃压合连接器取代两孔石墨垫,显著提高了一维色谱保留时间的稳定性,保证了中心切割范围的准确性,且消除了石墨对苯并[a]芘的吸附残留。同时,将本系统应用于卷烟烟气中苯并[a]芘的检测。采用剑桥滤片捕集烟气粒相物,环己烷萃取,以氘代苯并[a]芘为内标,直接用中心切割式多维气相色谱/质谱(MDGC/MS)法测定。该法线性关系良好,其线性范围为1.47~29.4μg/L(r2=0.999 9);重复性好,测得实际样品中苯并[a]芘含量的相对标准偏差(RSD)为1.94%;回收率为90.74%~101.86%;检出限和定量限分别为0.31ng/支及1.03ng/支,可以满足检测要求。应用本系统对2R4F参比卷烟烟气中苯并[a]芘进行了检测,结果与文献报道值基本一致。  相似文献   

18.
A compact, fast response, infrared spectrometer using four pulsed quantum cascade (QC) lasers has been applied to the analysis of gases in mainstream (MS) and sidestream (SS) cigarette smoke. QC lasers have many advantages over the traditional lead-salt tunable diode lasers, including near room temperature operation with thermoelectric cooling and single mode operation with improved long-term stability. The new instrument uses two 36 m, 0.3 l multiple pass absorption gas cells to obtain a time response of 0.1s for the MS smoke system and 0.4s for the SS smoke system. The concentrations of ammonia, ethylene, nitric oxide, and carbon dioxide for three different reference cigarettes were measured simultaneously in MS and SS smoke. A data rate of 20Hz provides sufficient resolution to determine the concentration profiles during each 2s puff in the MS smoke. Concentration profiles before, during and after the puffs also have been observed for these smoke constituents in SS smoke. Also, simultaneous measurements of CO(2) from a non-dispersive infrared (NDIR) analyzer are obtained for both MS and SS smoke. In addition, during this work, nitrous oxide was detected in both the MS and SS smoke for all reference cigarettes studied.  相似文献   

19.
An automated puff-by-puff mainstream smoke (MSS) system is developed to monitor real-time whole smoke in mainstream cigarette smoke using gas chromatography (GC)-mass spectrometry (MS). The whole-smoke analysis is based on automated sample collection and injection into the GC-MS system. The important feature of this system is the real-time rapid analysis that is simple, sensitive, precise, flexible, and exhibits low carryover of volatile and semivolatile smoke constituents. The system is equipped with an automated sampling and switching valve and a smoking machine. The key improvements of the system, as compared with current and alternative methodologies, include minimizing variations caused by operator sampling techniques, the real-time analysis of MSS, the detection of flavorants in MSS from a single puff of cigarette smoke, the ability to analyze numerous smoke constituents from either whole smoke or the gas phase of a single puff, the ability to monitor a few selected smoke constituents in whole smoke using multiple puffs, and its good feasibility compared with solvent extraction and impinger trapping procedures for volatile organic compounds in MSS. System configuration and sampling methodologies are described. Sensitivity, flexibility, precision, feasibility, carryover, and applications of the system are discussed.  相似文献   

20.
Endogenous metals present in tobacco from agricultural practices have been purported to generate metal carbonyls in cigarette smoke. Transition metal catalysts, such as iron oxide, have been investigated for the reduction of carbon monoxide (CO) in cigarette smoke. These studies motivated the development of an analytical method to determine if iron pentacarbonyl [Fe(CO)(5)] is present in mainstream smoke from cigarette models having cigarette paper made with iron oxide. An FT-IR puff-by-puff method was developed and the detection limit was determined using two primary reference spectra from different sources to estimate the amount of Fe(CO)(5) present in a high-pressure steel cylinder of CO. We do not detect Fe(CO)(5) in a single 35 mL puff from reference cigarettes or from those cigarette models having cigarette paper made with iron oxide, with a 30-ppbV limit of detection (LOD). Also, it was shown that a filter containing activated carbon would remove Fe(CO)(5).  相似文献   