首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 843 毫秒
1.
In this research, a new ultrasound‐assisted dispersive micro‐solid‐phase extraction method based on N‐doped mesoporous carbon sorbent followed by high‐performance liquid chromatography equipped with diode array detector for trace measurement of 1‐hydroxypyrene as a metabolite of exposure to polycyclic aromatic hydrocarbons was optimized. Herein, the hard template method was used for the preparation of N‐doped mesoporous carbon sorbent. The prepared sorbent was characterized using the Brunauer–Emmett–Teller method, transmission electron microscopy, and elemental analysis. Parameters affecting the extraction of the target metabolite were investigated using the Box–Behnken design method. Considering optimum parameters, the plotted calibration curve for 1‐hydroxypyrene was linearly correlated with the concentration span of 0.1–50 μg/L for urine media. The accuracy of the optimized procedure was examined through the relative recovery tests on the fortified urine specimens. The relative recoveries fell between 95 and 101%. The method detection limit of the proposed procedure was also calculated to be 0.03 μg/L.  相似文献   

2.
A molecularly imprinted polymer (MIP) was synthesized and evaluated to selectively extract an alpha-blocker, i.e. alfuzosin, from human plasma. The synthesis of the MIP was performed in dichloromethane with methacrylic acid as monomer and the target drug as template. A first series of experiments was carried out in dichloromethane to estimate the potential of the MIP in its specific recognition medium, i.e. dichloromethane, by developing a selective procedure and by measuring the capacity of the sorbent. An optimized procedure was developed for the selective extraction of alfuzosin with a recovery close to 100% in this medium and a specific capacity of 1.3 micromol g(-1) of MIP was measured. A study in aqueous media was also carried out by a comprehensive approach of the retention mechanism in order to build a selective procedure of extraction. The effects of the amount and of the charge of cations were studied and an optimal pH value was defined to limit matrix effects. Then, the alfuzosin MIP was then directly used to selectively extract the target drug from human plasma with an extraction recovery of 60%. Lastly, a soil was extracted by a pressurized solvent and the resulting extract was cleaned up on the MIP, showing the possibility to use this selective sorbent for the sample treatment of various complex matrices.  相似文献   

3.
Magnetite nanoparticles coated with silica and hydrophobic octadecyl layers were successfully synthesized and used in magnetic solid phase extraction of tetracyclines from water samples. The magnetite nanoparticles facilitated a convenient magnetic separation of sorbent from an aqueous sample, the octadecyl layer helped to enhance the adsorption ability and the silica layer helped to prevent the aggregation of the magnetite nanoparticles. The effect of various parameters on the extraction efficiency were optimized including the amount of sorbent, sample pH, stirring rate, extraction time and desorption conditions. Under the optimum conditions, the recoveries were in the range of 82 to 88%, the calibration curves were linear over the concentration range of 0.002 to 1.0 μg/mL for oxytetracycline and 0.01 to 1.0 μg/mL for tetracycline and chlortetracycline, respectively. The developed method had several advantages such as simplicity, convenience, cost-effectiveness and high extraction efficiency.  相似文献   

4.
A pipette tip multiwalled-carbon nanotube solid-phase extraction (PT-MWCNTs-SPE) coupled with flame atomic absorption spectrometry (FAAS) was developed for extraction and determination of lead in hair samples. In this study, PT-MWCNTs-SPE cartridge, assembled by packing MWCNTs as a sorbent into a 100-μL pipette tip. Taguchi’s method (L9 orthogonal array (OA)) as a statistical design of experiments was employed to optimise the factors and experiments that affected on the recovery of Pb(II). Under the optimum conditions, four parameters such as pH (P), volume of ligand (AL), sorbent amount (SA) and eluent concentrations of HNO3 (EC) were chosen as important affecting parameters. The limit of detection (LOD) of this method was 0.86 µg L?1 with relative standard deviations (RSD) ≤3% for Pb(II). Afterwards, the accuracy of proposed method was evaluated by TMDA 53.3 fortified water and NCS ZC 81002b human hair certified reference materials. The procedure was applied to lead contents of water and hair samples.  相似文献   

5.
Magnetite nanoparticles incorporated into alginate beads and coated with a polypyrrole adsorbent were prepared (polypyrrole/Fe3O4/alginate bead) and used as an effective magnetic solid‐phase extraction sorbent for the extraction and enrichment of endocrine‐disrupting compounds (estriol, β‐estradiol and bisphenol A) in water samples. The determination of the extracted endocrine‐disrupting compounds was performed using high‐performance liquid chromatography with a fluorescence detector. The effect of various parameters on the extraction efficiency of endocrine disrupting compounds were investigated and optimized including the type and amount of sorbent, sample pH, extraction time, stirring speed, and desorption conditions. Under optimum conditions, the calibration curves were linear in the concentration range of 0.5–100.0 μg/L, and the limit of detection was 0.5 μg/L. The developed method showed a high extraction efficiency, the recoveries were in the range of 90.5 ± 4.1 to 98.2 ± 5.5%. The developed sorbent was easy to prepare, was cost‐effective, robust, and provided a good reproducibility (RSDs < 5%), and could be reused 16 times. The developed method was successfully applied for the determination of endocrine‐disrupting compounds in water samples.  相似文献   

6.
A single-step extraction-cleanup procedure involving microwave-assisted extraction (MAE) and micro-solid-phase extraction (micro-SPE) has been developed for the analysis of polycyclic aromatic hydrocarbons (PAHs) from soil samples. Micro-SPE is a relatively new extraction procedure that makes use of a sorbent enclosed within a sealed polypropylene membrane envelope. In the present work, for the first time, graphite fiber was used as a sorbent material for extraction. MAE-micro-SPE was used to cleanup sediment samples and to extract and preconcentrate five PAHs in sediment samples prepared as slurries with addition of water. The best extraction conditions comprised of microwave heating at 50 degrees C for a duration of 20 min, and an elution (desorption) time of 5 min using acetonitrile with sonication. Using gas chromatography (GC)-flame ionization detection (FID), the limits of detection (LODs) of the PAHs ranged between 2.2 and 3.6 ng/g. With GC-mass spectrometry (MS), LODs were between 0.0017 and 0.0057 ng/g. The linear ranges were between 0.1 and 50 or 100 microg/g for GC-FID analysis, and 1 and 500 or 1000 ng/g for GC-MS analysis. Granular activated carbon was also used for the micro-SPE device but was found to be not as efficient in the PAH extraction. The MAE-micro-SPE method was successfully used for the extraction of PAHs in river and marine sediments, demonstrating its applicability to real environmental solid matrixes.  相似文献   

7.
A new chelating polymeric sorbent has been developed using polystyrene resin grafted with ethylenediamino tris(methylenephosphonic) acid. After characterisation by FTIR and elementary analysis, the new grafted resin has been investigated in liquid–solid extraction of uranium(VI). The influence of analytical parameters including pH, amount of resin, metal ion concentration, sample volume and ionic strength were investigated on the recovery of U(VI). Adsorption kinetic and isotherm studies were also carried out to understand the nature of the sorption of uranium(VI) by the resin. The total sorption capacity was found to be 41.76 mg/g under optimum conditions. The total desorption of the sorbed uranium ions was successfully performed with 0.1 M ammonium carbonate. Further, the effect of temperature was realized and the thermodynamic parameters were calculated.  相似文献   

8.
The coextraction of acidic and basic compounds from different mediums is a significant concept in sample preparation. In this work, simultaneous extraction of acidic, basic, and neutral analytes in a single step was carried out for the first time. This procedure employed the dispersive solid‐phase microextraction of analytes with magnetic graphene oxide (graphene oxide/Fe3O4) sorbent followed by gas chromatography with flame ionization detection. After the adsorption of analytes by vortexing and decantation of the supernatant with a magnet, the sorbent was eluted with acetonitrile/methanol (2:1) mixture. The parameters affecting the extraction efficiency were optimized and obtained as follows: sorbent amount 60 mg, desorption time 1 min, extraction time 5 min, pH of the sample 7, sample volume 20 mL, and elution solvent volume 0.3 mL. Under the optimum conditions, linear dynamic ranges were achieved in the range of 0.5–4, 0.25–4, and 0.25–2 μg/mL and limits of detection were 0.341, 0.110, and 0.167 μg/mL for aniline, phenol, and naphthalene, respectively. The relative standard deviations were in the range of 3.3–5.7% in eight repeated extractions. Finally, the applicability of the method was evaluated by the extraction and determination of analytes in stream water and drinking water samples and satisfactory results were obtained.  相似文献   

9.
A SBA‐15/polyaniline para‐toluenesulfonic acid nanocomposite supported micro‐solid‐phase extraction procedure has been developed for the extraction of parabens (methylparaben, ethylparaben, and propylparaben) from wastewater and cosmetic products. The variables of interest in the extraction process were pH of sample, sample and eluent volumes, sorbent amount, salting‐out effect, extraction and desorption time, and stirring rate. A Plackett–Burman design was performed for the screening of variables in order to determine the significant variables affecting the extraction efficiency. Then, the significant factors were optimized by using a central composite design. The optimum experimental conditions found at 50 mL sample solution, extraction and desorption times of 40 and 20 min, respectively, 500 μL of 3% v/v acetic acid in methanol as eluent, 0.01 M salt addition, and 10 mg of the sorbent. Under the optimum conditions, the developed method provided detection limits in the range of 0.08–0.4 ng/mL with good repeatability (RSD% < 7) and linearity (r2 = 0.997–0.999) for the three parabens. Finally, this fast and efficient method was employed for the determination of target analytes in cosmetic products and wastewater, and satisfactory results were obtained.  相似文献   

10.
A magnetic solid‐phase extraction sorbent of polypyrrole/silica/magnetite nanoparticles was successfully synthesized and applied for the extraction and preconcentration of sulfonamides in water samples. The magnetite nanoparticles provided a simple and fast separation method for the analytes in water samples. The silica coating increased the surface area that helped to increase the polypyrrole layer. The polypyrrole‐coated silica provided a high extraction efficiency due to the π–π and hydrophobic interactions between the polypyrrole and sulfonamides. Several parameters that affected the extraction efficiencies, i.e. the amount of sorbent, pH of the sample, extraction time, extraction temperature, ionic strength, and desorption conditions were investigated. Under the optimal conditions, the method was linear over the range of 0.30–200 μg/L for sulfadiazine and sulfamerazine, and 1.0–200 μg/L for sulfamethazine and sulfamonomethoxine. The limit of detection was 0.30 μg/L for sulfadiazine and sulfamerazine and 1.0 μg/L for sulfamethazine and sulfamonomethoxine. This simple and rapid method was successfully applied to efficiently extract sulfonamides from water samples. It showed a high extraction efficiency for all tested sulfonamides, and the recoveries were in the range of 86.7–99.7% with relative standard deviations of < 6%.  相似文献   

11.
A magnetic solid-phase extraction sorbent consisting of polyaniline-coated magnetite nanoparticles entrapped in alginate beads (PANI/alginate/Fe3O4) was successfully synthesised and applied for the extraction and preconcentration of polycyclic aromatic hydrocarbons (PAHs) in water samples. The magnetite nanoparticles helped to provide an easy and rapid isolation of the sorbent from the sample solution using an external magnet. The alginate beads helped to increase the surface area for polyaniline coating. The polyaniline-coated alginate/magnetite composite helped to increase the extraction efficiency due to the π–π interactions between the polyaniline and the PAHs. Various parameters that affected the extraction efficiencies were optimised including the polymerisation time, the amount of sorbent, sample pH, extraction time, ionic strength, and desorption conditions. Under the optimal conditions, a linear response was achieved in the concentration range of 0.040–50.0 µg L?1, and the limit of detection was 0.010 µg L?1. This simple, convenient, cost-effective, and environmentally friendly method was successfully applied for the extraction and enrichment of PAHs in water samples. The recoveries ranged from 86.0% to 97.8% with a relative standard deviation <10 %.  相似文献   

12.
A simple and specific analytical method was developed and tested for the determination of pharmaceuticals in mollusc samples. A combination of microwave-assisted micellar extraction (MAME) and solid-phase extraction (SPE) using a non-ionic surfactant, polyoxyethylene 10 lauryl ether, was examined to extract and determine simultaneously a group of pharmaceuticals such as carbamazepine, clorfibric acid, ketoprofen, naproxen, bezafibrate and ibuprofen by liquid chromatography using UV-diode array detector. The MAME extraction performance was evaluated by studying various parameters such as the volume and concentration of surfactant and microwave conditions. Finally, an OASIS HLB cartridge was used as an optimum SPE sorbent to clean up the extracts and preconcentrate the selected analytes. The proposed method showed satisfactory linearity and reproducibility (between 3 and 15%), as well as detection limits ranging from 30 to 220 ng/g. Finally, the method was successfully applied to the determination of the target pharmaceuticals in various kinds of mollusc samples. This study has demonstrated that microwave-assisted micellar extraction with solid-phase extraction may be used as a viable alternative to conventional methods for the extraction of pharmaceuticals in this type of matrices.  相似文献   

13.
Multiwalled carbon nanotubes functionalized by oxidation of original multiwalled carbon nanotubes with NaClO were prepared and their application as solid phase extraction sorbent for 2,4-dichlorophenoxyacetic acid (2,4-D) was investigated systemically, and a new method was developed for the determination of trace 2,4-D in water samples based on extraction and preconcentration of 2,4-D with solid phase extraction columns packed with NaClO-treated multiwalled carbon nanotubes prior to its determination by HPLC. The optimum experimental parameters for preconcentration of 2,4-D, including the column activating conditions, the amount of the sorbent, pH of the sample, elution composition, and elution volume, were investigated. The results indicated 2,4-D could be quantitatively retained by 100 mg NaClO-treated multiwalled carbon nanotubes at pH 5, and then eluted completely with 10 mL 3:1 (v/v) methanol-ammonium acetate solution (0.3 mol/L). The detection limit of this method for 2,4-D was 0.15 μg/L, and the relative standard deviation was 2.3% for fortified tap water samples and 2.5% for fortified riverine water sample at the 10 μg/L level. The method was validated using fortified tap water and riverine water samples with known amount of 2,4-D at the 0.4, 10, and 30 μg/L levels, respectively.  相似文献   

14.
A novel and very simple microextraction approach for pre-concentration and direct solid phase spectrophotometric measurement has been developed for the determination of chromogenic analytes. The model analyte to assess this approach was the chromophore malachite green (MG). The analyte was extracted from water samples onto a small rotating disk made of Teflon containing a sorbent phase of polydimethylsiloxane (PDMS) on one of its surfaces. We refer to the extraction procedure as rotating disk sorptive extraction (RDSE). After extraction, the sorbent phase with the concentrated analyte was separated from the Teflon disk and used directly for MG determination by solid phase spectrophotometry at 624 nm, without the necessity of a desorption step. Chemical and extraction variables such as concentration of sodium sulfate, pH, disk rotational velocity, extraction time, and temperature were studied in order to establish the best conditions for extraction. Under optimum conditions, the extraction of MG was carried out in 18 min and 90 min, for sample volumes of 100mL or 1000 mL, respectively. The detection limit, based on three times the standard deviation of the blank phase (3σ(b)), was 1.4 μg L?1 and the repeatability, expressed as relative standard deviation (RSD), for 20 μg L?1 MG was 8.1%. This study also applied the method to real samples, obtaining quantitative recovery (mean recovery of 99.3%). The PDMS phases could be reused after desorbing the MG into methanol for 3h. Replacement of the PDMS film onto the disk is very easy and low cost.  相似文献   

15.
ABSTRACT

In the present study, novel bioconjugated sorbents (peptide and oligo-nucleotide on the cobalt aluminate nanomaterials) were used to remove lead through miniaturised process and the concentration of lead was measured by inductively coupled plasma mass spectrometry. For this aim, lead was collected on sorbent in mini tube, and the influences of experimental conditions (e.g. pH of sample, amount of sorbent, concentration of eluent, foreign ions) and retention parameters on the recovery of the lead element were examined. After the optimisation of experimental parameters, a successful separation was obtained at pH 7.5 with high (>95%) quantitative recovery and high precision (<10% relative standard deviation). Using the proposed bioconjugated sorbents, the lead in sea water and tap water samples could be practically and easily removed with 95% confidence level. The detection limits of this method for lead using oligonucleotide and peptide on the cobalt aluminate nanomaterials were 0.14 and 0.12 µg/L (3σ, N = 10) with sample-matched blanks. This method can be widely used as promising and cost-effective nanomaterials to remove lead from water systems.  相似文献   

16.
A new method based on the combination of magnetic solid phase extraction (MSPE) and spectrofluorimetric determination was developed for isolation and preconcentration of fluoxetine form aquatic and biological samples using sodium dodecyl sulfate (SDS) coated Fe(3)O(4) nanoparticles (NPs) as a sorbent. The unique properties of Fe(3)O(4) NPs including high surface area and strong magnetism were utilized effectively in the MSPE process. Effect of different parameters influencing the extraction efficiency of fluoxetine including the amount of Fe(3)O(4) and SDS, pH value, sample volume, extraction time, desorption solvent and time were optimized. Under optimized condition, the method was successfully applied to the extraction of fluoxetine from water and urine samples and absolute recovery amount of 85%, detection limit of 20 μg L(-1) and a relative standard deviation (RSD) of 1.4% were obtained. The method linear response was over a range of 50-1000 μg L(-1) with R(2)=0.9968. The relative recovery in different aquatic and urine matrices were investigated and values of 80% to 104% were obtained. The whole procedure showed to be conveniently fast, efficient and economical for extraction of fluoxetine from environmental and biological samples.  相似文献   

17.
A straightforward functionalization procedure is proposed for synthesizing a cotton‐supported graphene as an extraction material, which is effectively employed for the extraction of multiclass pesticides from environmental waters prior to their determination by gas chromatography with mass spectrometry. Different experimental parameters that affect the extraction efficiency, including pH of the extraction, stirring rate, extraction time, ionic strength, presence of humic acid, sample volume, amount of sorbent, and elution conditions, were investigated and properly established. The advantages of the present extraction method are the simplicity of implementation, rapidity, and low consumption of sorbent per extraction. Moreover, the pesticides on the adsorbent are stable, under certain storage conditions, rendering the cotton‐supported graphene suitable for environmental field studies. The applicability of the cotton–graphene‐based procedure for routine analysis was demonstrated by the determination of pesticides in a lake water sample. The recoveries ranged from 83 to 107%, the limits of quantitation were in the range of 0.02–0.09 μg/L, and the calculated relative standard deviations varied from 3 to 8% (data obtained with the same batch of sorbent). Because of the acceptable analytical characteristics, the developed method shows great prospects in determining certain classes of pesticides in water.  相似文献   

18.
We describe a stoichiometric approach to the synthesis of molecularly imprinted polymers specific for auramine O. Using the stoichiometric interaction in molecular imprinting, no excess of binding sites is necessary and binding sites are only located inside the imprinted cavities. The free base of the template was obtained to facilitate the interaction with the monomers. Itaconic acid was selected as the functional monomer, and stoichiometric ratio of the interaction with the free base was investigated. The molecularly imprinted polymer preparation conditions such as cross‐linker, molar ratio, porogen were optimized as divinylbenzene, 1:2:20 and chloroform/N,N‐dimethylformamide, respectively. Under the optimum conditions, a good imprinting effect and very high selectivity were achieved. A solid‐phase extraction method was developed using the molecularly imprinted polymers as a sorbent and extraction procedure was optimized. The solid‐phase extraction method showed a high extraction recovery for auramine O in its hydrochloride form and free form compared to its analogues. The results strongly indicated that stoichiometric imprinting is an efficient method for development of high selectivity molecularly imprinted polymers for auramine O.  相似文献   

19.
A solid phase extraction procedure has been developed using multiwalled carbon nanotubes (MWCNTs) as a solid sorbent and quinalizarin [1,2,5,8-tetrahydroxyanthracene-9,10-dione] as a chelating agent for separation and preconcentration of trace amounts of some heavy metal ions, Cd(II), Cu(II), Ni(II), Pb(II) and Zn(II) before their determination by flame atomic absorption spectroscopy (FAAS). The influences of the analytical parameters, including pH, amounts of quinalizarin and adsorbent, sample volume, elution conditions such as volume and concentration of eluent, flow rates of solution and matrix ions, were investigated for the optimum recoveries of the analyte ions. No interference effects were observed from the foreign metal ions. The preconcentration factor was 100. The detection limit (LOD) for the investigated metals at the optimal conditions were observed in the range of 0.30–0.65 μg L?1. The relative standard deviation (RSDs), and the recoveries of standard addition for this method were lower than 5.0% and 96–102%, respectively. The new procedure was successfully applied to the determination of analytes in food, water and environmental samples with satisfactory results.  相似文献   

20.
以咖啡因作为模板分子,α-甲基丙烯酸为功能单体,乙二醇二甲基丙烯酸酯为交联剂,制备了咖啡因分子印迹聚合物(MIP)。与非印迹聚合物(NIP)相比,MIP对咖啡因具有更高的吸附容量和选择性,MIP和NIP对咖啡因的最大静态吸附量分别为28.1和16.5mg/g,相对选择因子为1.25。以咖啡因分子印迹聚合物为固相萃取填料,结合高效液相色谱(HPLC),建立了茶水中咖啡因浓度及人饮茶后血清中咖啡因浓度的检测方法。考察了洗脱剂种类和用量对咖啡因回收率的影响。当萃取柱依次以2mL水活化,水溶液上样,2mL水淋洗,6mL甲醇-乙酸(9∶1,V/V)洗脱,咖啡因在MIP固相萃取柱上的回收率达到97.5%,而在NIP柱上的回收率仅为54.9%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号