首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
A new hand-held amperometric sensor for monitoring of saliva and other oral fluid-based components is described. The amperometric sensor includes a flow through amperometric detector coupled with a micropipette, and an electronic block which consists of an amplifier, peak detector, microprocessor and display. All operations, such as sample injection, electrochemical detection and data processing are accomplished using only one action, by pressing the plunger of the micropipette. The instrument has been applied for assay of salivary peroxidase, human luteinizing hormone and human chorionic gonadotropin. The low detection limit of peroxidase is 0.5 ng/ml (defined as the concentration which gives a signal with S/N>2). The response time of the sensor is 1-3 s. The linear dynamic range of the hormones is from 1.0 to 80 mUI/ml. The life time of the hand-held amperometric device without regeneration of the electrode surface is 12 months. The sensor has the potential as a tool for noninvasive physiological studies and diagnostic strategies.  相似文献   

2.
《Electroanalysis》2003,15(3):219-224
A novel hydrogen peroxide biosensor has been constructed based on the characteristics of the carbon nanotube. The multiwall carbon nanotube (MWNT) was used as a coimmobilization matrix to incorporate horseradish peroxidase (HRP) and electron transfer mediator methylene blue (MB) onto a glassy carbon electrode surface. Cyclic voltammetry and amperometric measurements were employed to demonstrate the feasibility of methylene blue as an electron carrier between the immobilized peroxidase and the surface of glassy carbon electrode. The amperometric response of this resulting biosensor to H2O2 shows a linear relation in the range from 4 μM to 2 mM. The detection limit was 1 μM when the signal to noise ratio is 3. The presence of dopamine and ascorbic acid hardly affects the sensitive determination of H2O2. This biosensor also possesses very good stability and reproducibility.  相似文献   

3.
A new H2O2 enzymeless sensor has been fabricated by incorporation of thionin onto multiwall carbon nanotubes (MWCNTs) modified glassy carbon electrode. First 50 μL of acetone solution containing dispersed MWCNTs was pipetted onto the surface of GC electrode, then, after solvent evaporations, the MWCNTs modified GC electrode was immersed into an aqueous solution of thionin (electroless deposition) for a short period of time <5–50 s. The adsorbed thin film of thionin was found to facilitate the reduction of hydrogen peroxide in the absence of peroxidase enzyme. Also the modified electrode shows excellent catalytic activity for oxygen reduction at reduced overpotential. The rotating modified electrode shows excellent analytical performance for amperometric determination of hydrogen peroxide, at reduced overpotentials. Typical calibration at ?0.3 V vs. reference electrode, Ag/AgCl/3 M KCl, shows a detection limit of 0.38 μM, a sensitivity of 11.5 nA/μM and a liner range from 20 μM to 3.0 mM of hydrogen peroxide. The glucose biosensor was fabricated by covering a thin film of sol–gel composite containing glucose oxides on the surface of thionin/MWCNTs modified GC electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The detection limit, sensitivity and liner calibration rang were 1 μM, 18.3 μA/mM and 10 μM–6.0 mM, respectively. In addition biosensor can reach 90% of steady currents in about 3.0 s and interference effect of the electroactive existing species (ascorbic acid–uric acid and acetaminophen) is eliminated. The usefulness of biosensor for direct glucose quantification in human blood serum matrix is also discussed. This sensor can be used as an amperometric detector for monitoring oxidase based biosensors.  相似文献   

4.
将壳聚糖(CHI)分散的羧基化多壁碳纳米管(MWCNT)吸附到玻碳电极(GCE)表面,形成负电荷界面,利用静电吸附和金-氮(Au-N)、金-硫(Au-S)共价键作用将阳离子电子媒介体硫堇(THI)和纳米金颗粒(GNPs)层层自组装到电极表面,通过纳米金单层吸附唾液分泌性免疫球蛋白A(sIgA),最后用辣根过氧化物酶(H...  相似文献   

5.
A simple, selective and stable biosensor with the enzymatic reactor based on choline oxidase (ChOx) was developed and applied for the determination of choline (Ch) in flow injection analysis with amperometric detection. The enzyme ChOx was covalently immobilized with glutaraldehyde to mesoporous silica powder (SBA‐15) previously covered by NH2‐groups. This powder was found as an optimal filling of the reactor. The detection of Ch is based on amperometric monitoring of consumed oxygen during the enzymatic reaction, which is directly proportional to Ch concentration. Two arrangements of an electrolytic cell in FIA, namely wall‐jet cell with working silver solid amalgam electrode covered by mercury film and flow‐through cell with tubular detector of polished silver solid amalgam were compared. The experimental parameters affecting the sensitivity and stability of the biosensor (i. e. pH of the carrier solution, volume of reactor, amount of the immobilized enzyme, the detection potential, flow rate, etc.) were optimized. Under the optimized conditions, the limit of detection was found to be 9.0×10?6 mol L?1. The Michaelis‐Menten constant for covalently immobilized ChOx on SBA‐15 was calculated. The proposed amperometric biosensor with the developed ChOx‐based reactor exhibits good repeatability, reproducibility, long‐term stability, and reusability. Its efficiency has been confirmed by the successful application for the determination of Ch in two commercial pharmaceuticals.  相似文献   

6.
A voltammetric/amperometric detector based on a dual-electrode electrochemical detector is described for liquid chromatography. The detector combines the advantages of both voltammetric and amperometric detection. A three-dimensional data array of current response as a function of both time (chromatographic domain) and potential (electrochemical domain) is obtained. From the chromatographic point of view, this allows post-experimental choice of the optimal detection potential. Different detection potentials can even be chosen for each chromatographic peak. Having the voltammetric data as well as the chromatographic data provides ready identification of chromatographically unresolved compounds and the ability to resolve such co-eluting compounds voltammetrically. The voltammetric data also provide a second method of peak identification for greater certainty in peak assignments. Voltammetric detection limits of less than 10 pmol of material injected on the column were achieved with this detection method. From the electrochemical perspective, voltammetric/amperometric detection provides a technique for obtaining hydrodynamic voltammograms with small amounts or small volumes of sample. Voltammograms can also be obtained for the individual components of complex mixtures without the need for isolation steps.  相似文献   

7.
A new amperometric biosensor based on D-aminoacid oxidase is described for the assay of R-perindopril. R-perindopril can be determined in the 400-20 nmol/L concentration range; the detection limit is 10 nmol/L. The selectivity was checked with S-perindopril, D- and L-proline, and polyvinylpyrrolidone. The main interfering species was D-proline. An automated system for the assay of R-perindopril based on the concept of flow injection with an amperometric biosensor (based on D-aminoacid oxidase) as detector is also described. The system is suitable for the on-line monitoring of R-perindopril at a sampling rate of 72 samples/h, in the linear range: 100 nmol/L -20 nmol/L with an RSD better than 0.09% (n = 10).  相似文献   

8.
Amperometric enzymatic biosensors have high selectivity and simplicity in use. It has advantages over other analytical methods in biochemistry, pharmacology, so it evokes strong interests1,2. Generally, the detection mode involved in oxidase based biosensors is often based on the electrochemical detection of hydrogen peroxide directly3,4. However the direct oxidation of hydrogen peroxide requires a relative high working potential (exceeding ca. 0.6 V vs. SCE), at which many biological sub…  相似文献   

9.
This work evaluated an amperometric biosensor based on multi‐wall carbon nanotubes (MWCNT), chemically modified with methylene blue (Met) and horseradish peroxidase (HRP), for detection of phenolic compounds. The dependences of the biosensor response due to the enzyme immobilization procedure, HRP amounts, pH and working potential were investigated. The amperometric response for catechol using the proposed biosensor showed a very wide linear response range (1 to 150 μmol L?1), good sensitivity (50 nA cm?2 μmol?1 L), excellent operational stability (after 300 determinations the response remained at 97%) and very good storage stability (lifetime>3 months). Based on all these characteristics, it is possible to affirm that the material is promising for phenol detection due to its good electrochemical response and enzyme stabilization. The biosensor response for various phenolic compounds was investigated.  相似文献   

10.
A non-destructive, rapid and simple to use sensing method for direct determination of glucose in non-processed fruits is described. The strategy involved on-line microdialysis sampling coupled with a continuous flow system with amperometric detection at an enzymatic biosensor. Apart from direct determination of glucose in fruit juices and blended fruits, this work describes for the first time the successful application of an enzymatic biosensor-based electrochemical approach to the non-invasive determination of glucose in raw fruits. The methodology correlates, through previous calibration set-up, the amperometric signal generated from glucose in non-processed fruits with its content in % (w/w). The comparison of the obtained results using the proposed approach in different fruits with those provided by other method involving the same commercial biosensor as amperometric detector in stirred solutions pointed out that there were no significant differences. Moreover, in comparison with other available methodologies, this microdialysis-coupled continuous flow system amperometric biosensor-based procedure features straightforward sample preparation, low cost, reduced assay time (sampling rate of 7 h−1) and ease of automation.  相似文献   

11.
A new amperometric biosensor based on D-aminoacid oxidase is described for the assay of R-perindopril. R-perindopril can be determined in the 400–¶20 nmol/L concentration range; the detection limit is ¶10 nmol/L. The selectivity was checked with S-perindopril, D- and L-proline, and polyvinylpyrrolidone. The main interfering species was D-proline. An automated system for the assay of R-perindopril based on the concept of flow injection with an amperometric biosensor (based on D-aminoacid oxidase) as detector is also described. The system is suitable for the on-line monitoring of R-perindopril at a sampling rate of 72 samples/h, in the linear range: 100 nmol/L –20 nmol/L with an RSD better than 0.09% (n = 10).  相似文献   

12.
Horseradish peroxidase, previously modified with 1‐adamantane moieties, was supramolecularly immobilized on gold electrodes coated with perthiolated β‐cyclodextrin. The functionalized electrode was employed for the construction of an amperometric biosensor device for hydrogen peroxide using 1 mM hydroquinone as electrochemical mediator. The biosensor exhibited a fast amperometric response (6 s) and a good linear response toward H2O2 concentration between 12 μM and 450 μM. The biosensor showed a sensitivity of 1.02 mA/M cm2, and a very low detection limit of 5 μM. The electrode retained 97% of its initial electrocatalytic activity after 30 days of storage at 4 0C in 50 mM sodium phosphate buffer, pH 7.0.  相似文献   

13.
A new sensor design is reported for the construction of an amperometric enzyme biosensor toward H (2)O(2). It was based in the supramolecular immobilization of alternating layers of horseradish peroxidase (either modified with 1-adamantane or beta-cyclodextrin-branched carboxymethylcellulose residues) on Au electrodes coated with polythiolated beta-cyclodextrin polymer. The analytical response of the electrodes, using 1 mM hydroquinone as an electrochemical mediator, increases when the number of enzyme layers increases. The biosensor having three enzyme layers showed a sensitivity of 720 microA/M cm (2) and a detection limit of 2 microM and retained 96% of its initial activity after 30 days of storage. The host-guest supramolecular nature of the immobilization method was confirmed by cyclic voltammetry.  相似文献   

14.
A new amperometric biosensor for hydrogen peroxide was developed based on adsorption of horseradish peroxidase at the glassy carbon electrode modified with zinc oxide nanoflowers produced by electrodeposition onto multi-walled carbon nanotubes (MWNTs) film. The morphology of the MWNTs/nano-ZnO electrode has been investigated by scanning electron microscopy (SEM), and the electrochemical performance of the electrode has also been studied by amperometric method. The resulting electrode offered an excellent detection for hydrogen peroxide at -0.11 V with a linear response range of 9.9×10^-7 to 2.9×10^-3 mol/L with a correlation coefficient of 0.991, and response time 〈5 s. The biosensor displays rapid response and expanded linear response range, and excellent stability.  相似文献   

15.
A novel amperometric biosensor utilizing two enzymes, glucose oxidase (GOD) and horseradish peroxidase (HRP), was developed for the cathodic detection of glucose. The glucose biosensor was constructed by electrochemical formation of a polypyrrole (PPy) membrane in the presence of GOD on the surface of a HRP-modified sol-gel derived-mediated ceramic carbon electrode. Ferrocenecarboxylic acid (FCA) was used as mediator to transfer electron between enzyme and electrode. In the hetero-bilayer configuration of electrode, all enzymes were well immobilized in electrode matrices and showed favorable enzymatic activities. The amperometric detection of glucose was carried out at +0.16 V (versus saturated calomel reference electrode (SCE)) in 0.1 M phosphate buffer solution (pH 6.9) with a linear response range between 8.0×10−5 and 1.3×10−3 M glucose. The biosensor showed a good suppression of interference in the amperometric detection.  相似文献   

16.
A practical biosensor system has been developed for the determination of urinary glucose using a flow-injection analysis (FIA) amperometric detector and ion-exchange chromatography. Glucose oxidase was immobilized onto porous aminopropyl glass beads via glutaraldehyde activation to form an immobilized enzyme column. On the basis of its negative charge at pH 5.5, endogenous urate in urine samples was effectively retained by an upstream anion-exchange resin column. The biosensor system possessed a sensitivity of 160 ±2.4 RU μM-1 (RU or relative unit is defined as 2.86 μV at the detection output) for glucose with a minimum detection level of 10 μM. When applied for the determination of urinary glucose, the result obtained compared very well with that of the widely accepted hexokinase assay. The immobilized glucose oxidase could be reused for more than 1000 repeated analyses without losing its original activity. The reuse of the acetate anion-exchange column before replacement would be about 25–30 analyses. Acetaminophen and ascorbic acid were also effectively adsorbed by the acetate anion exchanger. The introduction of this type of anion exchanger thus greatly improved the selectivity of the FIA biosensor system and fostered its applicability for the determination of glucose in urine samples.  相似文献   

17.
An enzyme sensor using differential pulse (DP) amperometric detection has been developed based on the measurement of the reduction current of the oxidized form of -nicotinamide adenine dinucleotide (NAD+) consumed by an enzyme reaction. This biosensor has the definite advantage to prevent interference caused by electrooxidative species such as ascorbate and uric acid and exhibits higher sensitivity and selectivity in comparison to the classical DC amperometric detector. The linear detection range of this biosensor was 5.0×10–5 — 5.0×10–4 mol/l and the relative standard deviation (R.S.D.) at 2.5×10–4 mol/l was 5.0%.  相似文献   

18.
液相色谱电化学检测抗结核药物—异烟肼   总被引:3,自引:0,他引:3  
李惠梅  汪尔康 《分析化学》1993,21(5):550-553
本文讨论了以无有机溶剂存在的水溶液为流动相异烟肼的液相色谱一薄层安培检测法。在所选定的实验条件下,检测限达2ng。应用本法分析了片剂中异烟肼的含量  相似文献   

19.
Mori V  Bertotti M 《Talanta》1998,47(3):651-658
The construction of a wall-jet cell with amperometric detection using a set of disc electrodes whose radii ranged from 5 to 750 mum has been proposed. The influence of some experimental parameters like flow rate and electrode radius on hydrodynamic voltammograms recorded for a 0.5 mmol dm(-3) potassium ferrocyanide solution also containing 0.1 mol dm(-3) KCl has been discussed. Some considerations regarding the current signals obtained from flow injection experiments using both a 5- and a 750-mum radius platinum electrode were carried out in order to achieve the lowest limit of detection, a value of 0.03 mumol dm(-3) ferrocyanide being calculated by using the 5-mum radius microelectrode as amperometric detector. The wall-jet cell has been used in the determination of nitrite in saliva by quantifying the triiodide formed in the reaction of the analyte with excess iodide in acidic medium. A 12.5-mum platinum disc microelectrode maintained at +0.2 V vs. Ag/AgCl was used as amperometric detector. Peaks obtained in fiagrams after injection of diluted saliva to the carrier stream containing 0.1 mol dm(-3) sulphuric acid and 20 mmol dm(-3) potassium iodide were compared to an analytical curve obtained in the same conditions (r(2)=0.997) for a nitrite concentration in the range 1-10 mumol dm(-3). The concentration of nitrite in the saliva sample after the appropriate correction for dilution was found to be 2.3 ppm (0.05 mmol dm(-3)), in a good agreement with results obtained by using a standard spectrophotometric procedure (2.5 ppm). The limit of detection of the method was calculated as 0.2 mumol dm(-3), and the reproducibility was checked by measuring the peak current for 19 injections of 10 muM nitrite, the standard deviation being 3.7%.  相似文献   

20.
A novel inhibition biosensor used for the detection of sulphides (Na2S) has been developed. The biosensor is based on the immobilisation of horseradish peroxidase (HRP) on the Sonogel-Carbon (SNGC) electrode using glutaraldehyde, Poly(4-vinylpyridine) and gold sononanoparticles (AuSNPs). The Poly(4-vinylpyridine) was used due to its high affinity for sulphide anions, while the presence of gold sononanoparticles enhances the electron transfer reaction and improves the analytical performance of the biosensor. The amperometric measurements were performed at an applied potential of ?0.15 V vs. Ag/AgCl in 50 mM sodium acetate buffer solution pH = 6.0. The apparent kinetic parameters (Kmapp, Vmax) of immobilised HRP were calculated in the absence of inhibitor (sulphide) using caffeic acid as substrate. Under the optimal experimental conditions, the determination of sulphide can be achieved in a dynamic range of 0.4–2.8 µM with a low limit of detection of 0.15 µM. The electrochemical impedance spectroscopy (EIS) was also used to characterise the interactions of substrate and inhibitor with the enzyme-modified electrode. The developed biosensor exhibited high sensitivity, selectivity and stability, and can be successfully applied to the detection of sulphide in water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号