1.
Stir-bar-sorptive extraction followed by liquid desorption and large-volume injection capillary gas chromatography with mass spectrometric detection (SBSE–LD–LVI-GC–MS), had been applied for the determination of ultra-traces of eight pyrethroid pesticides (acrinathrin, cypermethrin, deltamethrin, esfenvalerate, fenpropathrin, fenvalerate, and permethrin cis and trans isomers) in water samples. Instrumental calibration for selected-ion monitoring acquisition and conditions that could affect the SBSE–LD efficiency are fully discussed. By performing systematic assays on 30-mL water samples spiked at the 0.10 g L–1 level it was established that stir-bars coated with 47 L polydimethylsiloxane, an equilibrium time of 60 min (750 rpm), 5% methanol as organic modifier, and acetonitrile as back-extraction solvent, provided the best analytical performance to monitor pyrethroid pesticides in water matrices. Good accuracy (81.8–105.0%) and remarkable reproducibility (<11.7%) were obtained, and the experimental recovery data were in good agreement with the theoretical equilibrium described by octanol–water partition coefficients (log KO/W), with the exception of acrinathrin for which lower yields were measured. Excellent linear dynamic ranges between 25 and 400 ng L–1 (r2>0.994), low quantification (3.0–7.5 ng L–1) and detection (1.0–2.5 ng L–1) limits were also achieved for the eight pyrethroid pesticides studied. The method was successfully used for analysis of tapwater and groundwater matrices spiked at the 0.10 g L–1, revealing the suitability of the method for determination of pyrethroid pesticides in real samples. The method was shown be reliable and sensitive and a small volume of sample was required to monitor pyrethroids at ultra-trace levels, in compliance with international regulatory directives on water quality.  相似文献   

2.
A rapid analytical method for sensitive determination of 1,3-dichloro-2-propanol (1,3-DCP) in river water has been developed. 1,3-DCP is extracted from water with ethyl acetate. After filtration through sodium sulfate the ethyl acetate phase is analyzed by gas chromatography–mass spectrometry. The method uses 1,3-DCP-d5 as internal standard. Different extraction solvents, concentrations of ammonium sulfate in the water samples, and the effect of humic acid were tested and their influence on the recovery of DCP has been evaluated. The method quantification limit was 0.1 g L–1. For spiked water samples (0–5.2 g L–1, n=21) a repeatability coefficient of variation of 5.4% was obtained. The average recovery rate of 1,3-DCP was 105±3% (n=21). Stability tests, which were carried out with Danube river water, led to an estimated 1,3-DCP degradation rate of 0.008±0.0008 day–1 at 6°C.  相似文献   

3.
Summary An on-line, solid-phase extraction gas chromatography atomic-emission detection (SPE-GC-AED) system has been set up using an on-column interface to transfer 100 l of desorbing solvent to the GC part of the system. Analytical characteristics such as recovery, precision and linearity of calibration plots were comparable with those of the off-line combination of SPE-GC-AED using organophosphorus pesticides as test compounds. The fully on-line set-up causes a marked improvement in detection because of the quantitative transfer of the analytes from the SPE module to the GC: detection limits are as low as 5–20 ng l–1 for the analysis of 10 ml raw and spiked surface water samples using the phosphorus channel. Detection levels can be further enhanced by processing up to 100 ml samples. The integrated analytical system is robust. The potential of the on-line set up has been demonstrated for the analysis of surface water and waste water.  相似文献   

4.
Summary The stability of freeze-dried water samples spiked with eight agrochemicals (atrazine, simazine, linuron, carbaryl, propanil, fenitrothion, parathion and fenamiphos) were examined to evaluate their suitability as candidate reference materials for their determination in water samples. In addition, two different extraction procedures, liquid-liquid and supercritical fluid extraction, were compared for the isolation and trace enrichment of target analytes from freeze-dried water samples. Final analytical determinations were by gas chromatography-nitrogen phosphorus detection and electronic impact mass spectrometry, and by liquid chromatography-diode array detection. The whole methodology developed in this paper permitted the determination of pesticides spiked in water at levels varying from 0.03 to 6.9 g L–1.  相似文献   

5.
Summary A simple multi-residue procedure has been developed and applied to the analysis of pesticides in groundwater samples from the Comunidad Valenciana, a predominantly agricultural area on the Mediterranean coast of Spain. The procedure includes a liquid-liquid extraction, after addition of NaCl on the samples, and a subsequent analysis by capillary gas chromatography using a dual detection system with electron capture and nitrogen-phosphorous detectors. This allows the determination of more than 30 compounds (organophosphorous, organochlorine and pyrethroid pesticides) at the low ppb (g l–1) levels. Detection limits obtained varied between 0.01 g l–1 (lindane, fonofos) and 0.5 g l–1 (cypermethrin). An additional injection of the sample extracts into a gas chromatograph equipped with a column of different polarity and electron capture detector is used for the confirmation of chromatographic peaks. The recommended procedure has been applied to 66 ground water samples. Pesticides, including organophosphorus and organochlorine compounds were detected in 31 of them, in levels ranging from 0.02 to 0.7 g l–1.  相似文献   

6.
This paper reports the use of laboratory-prepared gold microelectrodes and square-wave voltammetry for analytical determination of low concentrations of the pesticide dichlorvos in pure and natural water samples. After optimization of the experimental and voltammetric conditions, the best voltammetric responses—current intensity and voltammetric profile—were obtained in 0.1 mol L–1 NaClO4 with f=100 s–1, a=50 mV, and Es=2 mV. The observed detection and quantification limits in pure water were 7.8 and 26.0 g L–1, respectively. The reproducibility and repeatability of the method were also determined; the results were 1.4% (n=5) and 1.2% (n=10), respectively. Possible interfering effects were evaluated in natural water samples collected at different points with different levels of contamination from agricultural, domestic, or industrial waste from an urban stream. Results showed that the detection and quantification limits increased as a function of the quantity of organic matter present in the samples. Nonetheless, the values observed for these method characteristics were below the maximum value allowed by the Brazilian code for organophosphorus pesticides in water samples. Recovery curves constructed using the standard addition method were shown to be satisfactory compared with those obtained from high-performance liquid chromatography, confirming the suitability of the method for analysis of natural water samples. Finally, when the method was used to determine dichlorvos in spiked cows milk samples, satisfactory recovery and relative standard deviations were obtained.  相似文献   

7.
This work describes the optimisation of a method to determinate fifteen phenolic compounds in waters, sediments and biota (green marine algae) by liquid chromatography coupled to mass spectrometry (LC-MS) with atmospheric pressure chemical ionisation (APCI) in the negative mode. The LC separations of the studied compounds and their MS parameters were optimised in order to improve selectivity and sensitivity. Separation was carried out with a C18 column using methanol and 0.005% acid acetic as mobile phase in gradient mode. The molecular ion was selected for the quantitation in selective ion monitoring (SIM) mode. A solid-phase extraction (SPE) method was applied in order to preconcentrate the target analytes from water samples. However, extraction of the compounds from sediment and biota samples was carried out by liquid–solid extraction with methanol/water after studying the influence of other organic solvents. In addition, a clean-up step by SPE with HLB Oasis cartridges was necessary for sediments and biota. The proposed analytical methodology was validated in the target environmental matrices by the analysis of spiked blank matrix samples. Detection limits were 10–50 ng L–1 for water, 1–5 g kg–1 for sediments and 2.5–5 g kg–1 for biota samples. Good recoveries and precision values were obtained for all matrices. This methodology has been successfully applied to the analysis of incurred water, sediment and biota samples from Andalusia (Spain).  相似文献   

8.
A new analytical method is proposed to determine more than 40 multiclass pesticides in different kinds of processed (whole, skimmed and powdered) and unprocessed (goat and human) milk samples using solid-phase microextraction (SPME). A comparative study between headspace (HS) and direct immersion (DI) was carried out. The effect of milk dilution and the use of acid to reduce the influence of the matrix in DI-SPME mode were also evaluated. DI of the SPME fiber into previously diluted and acidified milk samples achieved the best sensitivity results. Pesticides were determined using low-pressure gas chromatography-tandem mass spectrometry (LP-GC-MS/MS). Both of the selected techniques have been shown to be effective at reduce fat interference and can determine analytes present at very low concentrations (limits of quantification between 0.02 and 1.00 g L–1). Performance characteristics such as linearity, recovery, precision, and lower limits, together with an estimation of the measurement uncertainty using validation data, are presented for each pesticide. All of the pesticides presented recovery rates of between 81 and 110% and precision values lower than 12% (expressed as the relative standard deviation). The overall uncertainty of the method was estimated at three different concentrations (10, 25 and 50 g L–1) and was lower than 25.5% in all cases. The proposed analytical methodology was applied to the analysis of target pesticides in 35 samples: 15 commercial, 3 human and 17 goat milk samples. The metabolite p,p-DDE was the compound most frequently found in both the breast and goat milk samples, at concentration levels <20 g L–1. However, pesticide residues were not found in any of the other 15 commercial milk samples (skimmed, powdered and whole milk) analyzed.  相似文献   

9.
The efficiency of polyaniline (PANI), coated gold wire was investigated for use as a fiber for solid-phase microextraction (SPME). Aniline monomers were electropolymerized on gold wires by applying a constant current to an acetate buffer containing NaClO4 as supporting electrolyte for 30 min. These fibers were used for the extraction of some aliphatic alcohols from gaseous samples. The results obtained proved the ability of PANI fiber for sampling organic compounds from gaseous samples. From this work, optimum conditions for preparation and conditioning of fibers and for the extraction of analytes from gaseous samples were obtained. Under optimum conditions, one fiber was used for several equivalent analyses and the relative standard deviations (RSD) were <7% (n=6). However, fiber to fiber reproducibility was <9% (n=6). This fiber is firm and durable and is simply prepared. Calibration graphs were linear in the range: 0.1–10 g mL–1 for aliphatic alcohols; the detection limit range was 15–75 ng mL–1 (S/N=3) using a flame ionization detector.  相似文献   

10.
An analytical method was developed to determine the benzimidazole fungicides and their residues (benomyl, carbendazim, thiabendazole and fuberidazole) in real water samples. Analyses were performed by reverse phase (RP) HPLC with direct fluorescence detection with mobile phase methanol:water, 40:60 (v/v) with 0.6% (v/v) ammonia. The extraction of analytes from water samples was performed with the use of micellar systems. Specifically, oligoethylene glycol monoalkyl ether (Genapol X-080) and polyoxyethylene 10 lauryl ether (POLE) were used as extractants. The recoveries of fungicides obtained in spiked water samples ranged from 68% to 94% for Genapol and from 68% to 96% for POLE. The limit of detection (LOD) was lower than 6 g L–1 for carbendazim, 7 g L–1 benomyl, 0.15 g L–1 for thiabendazole and 0.01 g L–1 for fuberidazole in both surfactants.  相似文献   

11.
We have prepared a fiber for solid-phase microextraction of organochlorine pesticides. A graphene-polyaniline composite was electrochemically deposited on a platinum fiber by exploiting the unique properties of polyaniline and graphene. The modified fiber displays thermal stability up to 320 °C and can be used more than 70 times. It possesses high extraction efficiency due to the high specific surface of graphene. The Pt fiber was used for the extraction and subsequent GC determination of the pesticides heptachlor, aldrin, endrin and p,p’-DDT in aqueous samples. The effects of extraction time, extraction temperature, stirring rate, salinity and headspace volume were optimized. Calibration plots are linear (with an R2 of 0.990) in the 0.2 to 250 μg L–1 concentration range, and the limits of detection are below 11 ng L–1 (at an S/N of 3). The relative standard deviations for three replicate measurements with a single fiber were <11.0 %. The recovery of the pesticides from spiked seawater samples ranged from 81 % to 112 %.
Figure
The graphene–polyaniline (G/PANI) nanocomposite was prepared by simultaneous electropolymerization of G–aniline and used as a new coating for SPME of organochlorine pesticides as model compounds. The large delocalized π-electron system of G and high extraction capability of PANI caused to produce an efficient and sensitive sorbent for SPME  相似文献   

12.
Summary Analytical methods for the determination in environmental samples, of some selected Polycyclic Aromatic Hydrocarbons (PAH's), which are included on the EPA Priority Pollutant list, have been developed and evaluated. The methodology involves the extraction of PAH's from water samples by solvent extraction with dichloromethane. Solid samples were ultrasonically extracted with acetone/hexane and the extract was cleaned up on a silica gel/alumina column. The concentrated and cleaned up extracts were analysed by HPLC on a polymeric C18 column using a gradient of acetonitrile/water as the mobile phase and fluorescence detection. Typical detection limits lie in the range of 1–30 ng ml–1 of the analytes, but after sample pretreatment detection limits of 10–300 ng l–1 were obtained. The extraction, clean-up and HPLC methodology was applied to the determination of selected PAH's in coal washings samples and the method was validated by the quantification of PAH's in a natural contaminated and a spiked sediment.  相似文献   

13.
The use of a laboratory-made iodide ion-selective electrode with tubular configuration and based on a crystalline membrane (AgI/Ag2S) as the detector for ion chromatographic determination of iodide in urine and serum is described. A CIS reversed-phase column was coated withN-cetylpyridinium chloride to prepare a low-exchange-capacity analytical column and with hexadecyltrimethylammonium bromide to prepare a concentrator pre-column. A 2.0 ml min–1 flow rate of deionized water and 0.1 mol 1–1 KNO3 solution was used for the pre-concentration and for the chromatographic separation, respectively. For optimum performance of the detector a background level of iodide was added into the column effluent. A linear relationship (r = 0.9997) between tubular electrode potential (as peak height) and iodide concentration in the range 5–400 g 1–1 and a detection limit of 1.47 g 1–1 were obtained. The method shows good reproducibility for both peak height (2.2% RSD) and retention time (1.3% RSD). Recoveries on its application to the samples were 93.0–100.9% for urine and 91.4–106.0% for serum.  相似文献   

14.
An extraction system consisting of trilaurylamine N-oxide and benzene has been identified as a possible extractant for tracer arsenic (<10–3 M) from hydrochloric or sulfuric acid solutions with or without iodide. Benzene alone is less efficient as an extractant for arsenic when compared with trilaurylamine oxide dissolved in benzene. The mechanism of extraction is attributed to the formation of hydrated AsCl3, while the iodide complex is most probably AsI 4 . The role of the solvent and the other parameters affecting the extraction have been investigated. The results have been employed to determine arsenic in water samples by spectrophotometry using the molybdenum blue method. The extraction procedure was used for the analysis of 10 ml water samples containing 0.2–0.5 g of arsenic.  相似文献   

15.
An analytical procedure based on matrix solid-phase dispersion (MSPD) and liquid chromatography–mass spectrometry (LC-MS) was developed for determining three microcystins (MCs) in natural water blooms and cyanobacteria strain cultures. The procedure involves sample homogenization with C18, washed with dichloromethane to eliminate interfering compounds, and elution with acidic methanol. Results were compared to those achieved by using an organic solvent standard method. Mean recoveries of MCs with MSPD were 85–92% with intra-day relative standard deviation (RSDs) of 9–19%, whereas organic solvent extraction resulted in recovery rates of 92–105% with intra-day RSDs ranging from 8 to 18%. Limits of quantification (LOQs) were 1 g g–1 dry weight for the MCs either by MSPD or organic solvent extraction. The two analytical methods tested were specific and sensitive to the extraction of MCs and were applied to the detection of MCs in water blooms and culture strains. The concentration of MCs varied from 7 to 3,330 g g–1 of lyophilized cells with MC-LR always showing the highest concentration. MCs levels were higher in culture strains than in water blooms, except for MC-LR, whose concentration in blooms was slightly superior to that determined in culture strains.  相似文献   

16.
Summary The stability of atrazine, simazine, alachlor, metolachlor, and deethylatrazine on C18 Empore disks has been determined. Estuarine water (100 mL) spiked at 3 g L–1 with the target pesticide mixture was preconcentrated on the disks; the disks were then stored at –20°C, 4°C, and at room temperature for periods up to three months and were analyzed by gas chromatography with nitrogen-phosphorus detection. Complete recovery was observed after storage at –20°C throughout the period of the study. Losses up to maximum of 10% were observed after storage at 4°C. Higher losses (up to 24% for alachlor) occurred only at room temperature; the coefficient of variation for these determinations (8–11%) was also higher than that for the others (3–5%). The stability of the pesticides was dependent on the water matrix, on storage temperature, and on properties such as vapor pressure and water solubility.  相似文献   

17.
A new chromatographic extraction method has been developed using Amberlite XAD-16 (AXAD-16) resin chemically modified with (3-hydroxyphosphinoyl-2-oxo-propyl)phosphonic acid dibenzyl ester (POPDE). The chemically modified polymer was characterized by 13C CPMAS and 31P solid-state NMR, Fourier Transform–NIR–FIR–Raman spectroscopy, CHNPS elemental analysis, and thermogravimetric analysis. Extraction studies performed for U(VI), Th(IV), and La(III) showed good distribution ratio (D) values of approximately 103, even under high acidities (1–4 M). Various physiochemical parameters that influence the quantitative metal ion extraction were optimized by static and dynamic methods. Data obtained from kinetic studies revealed that a time duration of 10 min was sufficient to achieve complete metal ion extraction. Maximum metal sorption capacity values under optimum pH conditions were found to be 1.38, 1.33, and 0.75 mmol g–1 for U(VI), Th(IV), and La(III), respectively. Interference studies performed in the presence of concentrated diverse ions and electrolyte species showed quantitative analyte recovery with lower limits of analyte detection being 10 and 20 ng cm–3 for U(VI) and both Th(IV) and La(III), respectively. Sample breakthrough studies performed on the extraction column showed an enrichment factor value of 330 for U(VI) and 270 for Th(IV) and La(III), respectively. Analyte desorption was effective using 15 cm3 of 1 M (NH4)2CO3 with >99.8% analyte recovery. The analytical applicability of the developed resin was tested with synthetic mixtures mimicking nuclear spent fuels, seawater compositions and real water and geological samples. The rsd values of the data obtained were within 5.2%, thereby reflecting the reliability of the developed method.  相似文献   

18.
Summary A high-performance liquid-chromatographic method with UV detection (HPLC–UV) has been developed for quantification of ethylene terephthalate oligomers in olive oil, from which they were extracted with acetonitrile. Oligomers, from monomers (M1) to pentamers (M5), were jointly and/or individually identified by liquid chromatography with mass spectrometry (electron-impact mass spectrometry (EIMS) low- and high-resolution) and were quantified by HPLC–UV using an acetonitrile solution of the major oligomer (the trimer M3) as standard. For M3 recovery was 98.9%, the detection limit was 60 g L–2, and method precision was 2.03% (RSD). Migration of oligomers M1–M5 into 50 mL olive oil sealed in each of two brands of 10 cm × 10 cm poly(ethylene terephthalate) roasting bag was evaluated under two sets of conditions that approached but remained below the limit at which the bag material became physically deformed – heating for 7 min at 850 W in a microwave oven, or for 60 min at 200 °C in a conventional oven. Total migration was approximately 2.7 mg dm–2 under the former conditions and 3.5–4.1 mg dm–2 under the latter.Presented at the International Symposium on Separation and Characteristics of Natural and Synthetic Macromolecules, Amsterdam, The Netherlands, February 5–7, 2003  相似文献   

19.
A new multiresidue method has been developed and validated for the simultaneous extraction of more than two hundred pesticides, including non-polar and polar pesticides (carbamates, organochlorine, organophosphorous, pyrethroids, herbicides and insecticides) in urine at trace levels by gas and ultra high pressure liquid chromatography coupled to ion trap and triple quadrupole mass spectrometry, respectively (GC-IT-MS/MS, UHPLC-QqQ-MS/MS). Non-polar and polar pesticides were simultaneously extracted from urine samples by a simple and fast solid phase extraction (SPE) procedure using C18 cartridges as sorbent, and dichloromethane as elution solvent. Recovery was in the range of 60-120%. Precision values expressed as relative standard deviation (RSD) were lower than 25%. Identification and confirmation of the compounds were performed by the use of retention time windows, comparison of spectra (GC-amenable compounds) or the estimation of the ion ratio (LC-amenable compounds). For GC-amenable pesticides, limits of detection (LODs) ranged from 0.001 to 0.436 μg L−1 and limits of quantification (LOQs) from 0.003 to 1.452 μg L−1. For LC-amenable pesticides, LODs ranged from 0.003 to 1.048 μg L−1 and LOQs ranged from 0.011 to 3.494 μg L−1. Finally, the optimized method was applied to the analysis of fourteen real samples of infants from agricultural population. Some pesticides such as methoxyfenozide, tebufenozide, piperonyl butoxide and propoxur were found at concentrations ranged from 1.61 to 24.4 μg L−1, whereas methiocarb sulfoxide was detected at trace levels in two samples.  相似文献   

20.
An analytical procedure enabling routine analysis of four environmental estrogens at concentrations below 1 ng L–1 in estuarine water samples has been developed and validated. The method includes extraction of water samples using solid-phase extraction discs and detection by gas chromatography (GC) with tandem mass spectrometry (MS–MS) in electron-impact (EI) mode. The targeted estrogens included 17- and 17-estradiol (aE2, bE2), estrone (E1), and 17-ethinylestradiol (EE2), all known environmental endocrine disruptors. Method performance characteristics, for example trueness, recovery, calibration, precision, accuracy, limit of quantification (LOQ), and the stability of the compounds are presented for each of the selected estrogens. Application of the procedure to water samples from the Scheldt estuary (Belgium – The Netherlands), a polluted estuary with reported incidences of environmental endocrine disruption, revealed that E1 was detected most frequently at concentrations up to 7 ng L–1. aE2 was detected once only and concentrations of bE2 and EE2 were below the LOQ.Presented at the 9th FECS Conference on Chemistry and the Environment, Bordeaux, France, 29 August–1 September 2004  相似文献   