首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
To increase the thermal efficiency of gas turbines, inlet temperature of gas is increased. This results in the requirement of cooling of gas turbine blades and vanes. Internal cooling of gas turbine blades and vanes is one of several options. Two-pass channels are provided with ribs to enhance heat transfer at the expense of an increased pressure drop. The space in the blade is limited and requires channels with small aspect ratios. Numerical simulations have been performed to investigate heat transfer, flow field and pressure loss in a two-pass channel equipped with 45° ribs with aspect ratio (Win/H) equal to 1:3 in the inlet pass and 1:1 in the outlet pass with both connected together with a 180° bend. The results are compared with a higher aspect ratio channel (Win/H = 1:2, inlet pass). In the ribbed channel, a decrease in pressure drop was observed with a decrease in the aspect ratio of the channel. The smaller aspect ratio channel not only allows using more cooling channels in the blade, but also results in more heat transfer enhancement. The divider-to-tip wall distance (Wel) has influence on the pressure drop, as well as on the heat transfer enhancement at the bend and outlet pass. Heat transfer decreases with decrease in aspect ratio of the inlet pass of the two-pass channel. With increase in divider-to-tip wall distance, heat transfer tries to attain a constant value.  相似文献   

2.
In the present study, sizing of a single pass cross flow heat exchanger with unmixed fluid streams has been investigated. The heat exchanger is a cross flow heat exchanger. It has overall dimensions of 20 × 20 × 20 cm. Two the most common heat exchanger design problems are the rating and sizing problem. Sizing problems deal with designing an exchanger and determining its physical size to meet the specified heat duty, pressure drops and other considerations. It means the determination of the exchanger construction type, flow arrangement, heat transfer surface geometries and materials, and the physical sizes of an exchanger to meet specified heat transfer and pressure drop. In this study, the physical size (length, width, height, mass flow rates of both fluids and surface areas on each side of the exchanger) are determined. Inputs to the sizing problem are surface geometries, fluid mass flow rates, inlet and outlet fluid temperatures and pressure drop on each side. Dimensions of L a , L b , and L c for the selected surfaces were investigated such that the design meets the heat duty and pressure drops on both sides exactly.  相似文献   

3.
This article presents experiments conducted with two single rectangular mini-channels of same hydraulic diameter (1.4 mm) and different aspect ratios for conditions of horizontal boiling flow. The Forane® 365 HX used was subcooled (ΔTsub = 15 °C) for all the boiling curves presented in the paper. Local heat transfer coefficients were measured for heat flux ranging from 25 to 62 kW m−2 and mass flux from 200 kg m−2 s−1 to 400 kg m−2 s−1. The boiling flows were observed with two different cameras (depending on the flow velocity) through a visualization window. The flow patterns in the two channels were compared for similar conditions. The results show that the boiling heat transfer coefficient and the pressure drop values are different for the two single mini-channels. For low heat flux condition, the channel with lowest aspect ratio (H/W = 0.143) has a higher heat transfer coefficient. On the other hand, for high heat flux condition, the opposite situation occurs, namely the heat transfer coefficient becomes higher for the channel with highest aspect ratio (H/W = 0.43). This is probably due to the earlier onset of dryout in the channel with lowest aspect ratio. For the two cases of heating, the pressure drop for the two-phase flow remains lower for the channel with lowest aspect ratio. These results show that the aspect ratio plays a substantial role for boiling flows in rectangular channels. As for single-phase flows, the heat transfer characteristics are significantly influenced (even though the hydraulic diameter remains the same) by this parameter.  相似文献   

4.
This paper presents experimental investigations on Freon R141b flow boiling in rectangular microchannel heat sinks. The main aim is to provide an appropriate working fluid for microchannel flow boiling to meet the cooling demand of high power electronic devices. The microchannel heat sink used in this work contains 50 parallel channels, with a 60 × 200 (W × H) μm cross-section. The flow boiling heat transfer experiments are performed with R141b over mass velocities ranging from 400 to 980 kg/(m2 s) and heat flux from 40 to 700 kW/m2, and the outlet pressure satisfying the atmospheric condition. The fluid flow-rate, fluid inlet/outlet temperature, wall temperature, and pressure drop are measured. The results indicate that the mean heat transfer coefficient of R141b flow boiling in present microchannel heat sinks depends heavily on mass velocity and heat flux and can be predicted by Kandlikar’s correlation (Heat Transf Eng 25(3):86–93, 2004). The two-phase pressure drop keeps increasing as mass velocity and exit vapor quality rise.  相似文献   

5.
Local heat transfer coefficients and temperature distributions within the fluid for air flow around a 180° square-sectioned bend have been measured. The ratio of bend radius to hydraulic diameter of the duct is 3.35:1 and the flow entering the bend is sensibly fully developed. Measurements of air and wall temperatures span a range of Reynolds numbers from 9.9 × 103 to 9.2 × 104 with the principal emphasis given to the case of Re ? 5.6 × 104. This Reynolds number and geometric configuration coincide with that of a companion LDA study carried out by Chang et al1 which provides detailed maps of the mean and turbulent velocity fields. The data show that by 45° into the bend the heat transfer coefficients on the inner convex wall of the bend drop markedly while those on the other walls increase. By 90° the ratio of the heat transfer coefficients at the mid positions of the concave and convex walls is more than 2:1. Nevertheless this ratio is less than would be anticipated from considering two-dimensional flow on weakly curved surfaces. There is a general consistency between the velocity and the temperatyre field data in the heated fluid  相似文献   

6.
The heat transfer in subsonic high-temperature (T 2000°K) gas flow through a curved channel of rectangular cross section has been experimentally investigated. The local heat flow into the channel wall was measured by the modified gradient method, which consists in subdividing the walls by means of thin annular thermally-insulating partitions, measuring the temperature in the upper (gas) and lower (coolant) sections of the modules thus formed, and using these measurements to determine the local heat flux qw on the assumption that the thermal field in the module is homogeneous. The soundness of this method has been demonstrated theoretically and experimentally and the expediency of using it in the intensive wall cooling regime has been confirmed. The method is employed to find the local heat flux fields over the- entire surface of the channel. The integrated fluxes qw coincide to within 5% with the independently determined total increase in the enthalpy of the water in the cooling channels. A distinguishing feature of the investigation is the high relative curvature of the bend in the channel, which leads to the formation of a zone of intense separation on the convex (inner) wall. Three types of channel are examined. These differ with respect to the section beyond the bend which is either long or short or short with a contraction. A close correlation between the characteristics of the qw fields and the hydrodynamic effects is detected and explained. These effects comprise: separation and reattachment of the flow, secondary effects in the bend, the formation of an unclosed separation zone in the short outlet section, the localization of this zone when the outlet section includes a contraction, and specific gas dynamic effects near the intersection of the surfaces.Translated from Izvestiya Akademii Nauk SSSR, Mekhanika Zhidkosti i Gaza, No. 3, pp. 93–99, May–June, 1989.  相似文献   

7.
In this paper, the heat/mass transfer analogy was used to investigate the heat transfer and pressure drop in a square channel with triangular ribs on its two opposite walls. Reynolds number varied from 1 × 104 to 7 × 104; the dimensionless heights of the triangular ribs H/W were 0.04, 0.07, and 0.1; and their dimensionless pitches S/W were 0.45, 0.63, 1.0, 1.37, 1.55, and 2.1. Experimental results showed that the heat transfer coefficients of the wall with triangular rib were about 1 to 2.3 times larger than those of a smooth-channel wall, and the pressure drops along this roughened channel were about 1 to 10 times larger than those for a smooth channel. Correlations of heat transfer and pressure drop were obtained, which are useful for practical designs.  相似文献   

8.
Turbulent pressure drop and heat transfer characteristics in tubes with three different kinds of internally longitudinal fin patterns (interrupted wavy, sinusoidal wavy and plain) are numerically investigated for Re = 904–4,520. The channel velocity, temperature, and turbulence fields are obtained to discern the mechanisms of heat transfer enhancement. Numerical results indicate that the steady and spatially periodic growth and disruption of cross-sectional vortices occur near the tube/fin walls along the streamwise locations. The thermal boundary layers near the tube/fin surfaces are thereby periodically interrupted, with heat transfer near the recirculation zones being enhanced. The overall heat transfer coefficients in wavy channels are higher than those in a plain fin channel, while with larger pressure drop penalties. At the same waviness, the interrupted wavy fin tube could enhance heat transfer by 72–90%, with more than 2–4 times of pressure drop penalty. Among the fins studied, the sinusoidal wavy fin has the best comprehensive performance.  相似文献   

9.
This paper documents the numerical investigation of the effects of non-uniform magnetic fields, i.e. magnetic-ribs, on a liquid–metal flowing through a two-dimensional channel. The magnetic ribs are physically represented by electric currents flowing underneath the channel walls. The Lorentz forces generated by the magnetic ribs alter the flow field and, as consequence, the convective heat transfer and wall shear stress. The dimensionless numbers characterizing a liquid–metal flow through a magnetic field are the Reynolds (Re) and the Stuart (N) numbers. The latter provides the ratio of the Lorentz forces and the inertial forces. A liquid–metal flow in a laminar regime has been simulated in the absence of a magnetic field (ReH = 1000, N = 0), and in two different magnetic ribs configurations for increasing values of the Stuart number (ReH = 1000, N equal to 0.5, 2 and 5). The analysis of the resulting velocity, temperature and force fields has revealed the heat transport phenomena governing these magneto-hydro-dynamic flows. Moreover, it has been noticed that, by increasing the strength of the magnetic field, the convective heat transfer increases with local Nusselt numbers that are as much 27.0% larger if compared to those evaluated in the absence of the magnetic field. Such a convective heat transfer enhancement has been obtained at expenses of the pressure drop, which increases more than twice with respect to the non-magnetic case.  相似文献   

10.
Entropy generation in the flow field subjected to a porous block situated in a vertical channel is examined. The effects of channel inlet port height (vertical height between channel inlet port and the block center), porosity, and block aspect ratio on the entropy generation rate due to fluid friction and heat transfer in the fluid are examined. The governing equations of flow, heat transfer, and entropy are solved numerically using a control volume approach. Air is used as the flowing fluid in the channel. A uniform heat flux is considered in the block and natural convection is accommodated in the analysis. It is found that entropy generation rate due to fluid friction increases with increasing inlet port height, while this increase becomes gradual for entropy generation rate due to heat transfer for the inlet port height exceeding 0.03 m. The porosity lowers entropy generation rate due to fluid friction and heat transfer. The effect of block aspect ratio on entropy generation rate is notable; in which case, entropy generation rate increases for the block aspect ratio of 1:2.  相似文献   

11.
This article aims to numerically investigate mixed convection heat transfer in a two-dimensional horizontal channel with an open cavity. A discrete heat source is considered to be located on one of the walls of the cavity. Three different heating modes are considered which relate to the location of the heat source on three different walls (left, right and bottom) of the cavity. The analysis is carried out for a range of Richardson numbers and cavity aspect ratios. The results show that there are noticeable differences among the three heating modes. When the heat source is located on the right wall, the cavity with an aspect ratio of two has the highest heat transfer rate compared to other cavity heating modes. Moreover, when the heat source is located on the bottom wall, the flow field in the cavity with an aspect ratio of two experiences a fluctuating behaviour for Richardson number of 10. The results also show that at a fixed value of Richardson number, all three different heating modes show noticeable improvements in the heat transfer mechanism as the cavity aspect ratio increases.  相似文献   

12.
The in-tube cooling flow and heat transfer characteristics of R134a at supercritical pressures are measured experimentally for various pressures and mass fluxes in a horizontal tube. The tube is made of stainless steel with an inner diameter of 4.01 mm. Experiments are conducted for mass fluxes from 70 kg/m2 s to 405 kg/m2 s and pressures from 4.5 MPa to 5.5 MPa. The inlet refrigerant temperature is from 80 °C to 140 °C. The results show that the refrigerant temperature, the mass flux and the pressure all significantly affect the flow and heat transfer characteristics of R134a at supercritical pressures. The experimentally measured frictional pressure drop and heat transfer coefficient are compared with predicted results from several existing correlations. The comparisons show that the predicted frictional pressure drop using Petrov and Popov’s correlation accounting for the density and viscosity variations agree well with the measured data. Gnielinski’s correlation for the heat transfer coefficient agrees best with the measured data with deviations not exceeding 25%, while correlations based on supercritical CO2 heat transfer data overcorrect for the influence of the thermophysical property variations resulting in larger deviations. A new empirical correlation is developed based on the measured results by modifying Gnielinski’s equation with thermophysical property terms including both the property variations from the inlet to the outlet of the entire test section and from the bulk to the wall. Most of the experimental data is predicted by the new correlation within a range of 15%.  相似文献   

13.
In this study, fully developed heat and fluid flow in a parallel plate channel partially filled with porous layer is analyzed both analytically and numerically. The porous layer is located at the center of the channel and uniform heat flux is applied at the walls. The heat and fluid flow equations for clear fluid and porous regions are separately solved. Continues shear stress and heat flux conditions at the interface are used to determine the interface velocity and temperature. The velocity and temperature profiles in the channel for different values of Darcy number, thermal conductivity ratio, and porous layer thickness are plotted and discussed. The values of Nusselt number and friction factor of a fully clear fluid channel (Nu cl = 4.12 and fRe cl = 24) are used to define heat transfer increment ratio (eth = Nup/Nucl)({\varepsilon _{\rm th} =Nu_{\rm p}/Nu_{\rm cl})} and pressure drop increment ratio (ep = fRep/fRecl )({\varepsilon_{\rm p} =fRe_{\rm p}/fRe_{\rm cl} )} and observe the effects of an inserted porous layer on the increase of heat transfer and pressure drop. The heat transfer and pressure drop increment ratios are used to define an overall performance (e = eth/ep)({\varepsilon = \varepsilon_{\rm th}/\varepsilon_{\rm p})} to evaluate overall benefits of an inserted porous layer in a parallel plate channel. The obtained results showed that for a partially porous filled channel, the value of e{\varepsilon} is highly influenced from Darcy number, but it is not affected from thermal conductivity ratio (k r) when k r > 2. For a fully porous material filled channel, the value of e{\varepsilon} is considerably affected from thermal conductivity ratio as the porous medium is in contact with the channel walls.  相似文献   

14.
The incompressible laminar flow of air and heat transfer in a channel with a backward-facing step is studied for steady cases and for pulsatile inlet conditions. For steady flows the influence of the inlet velocity profile, the height of the step and the Reynolds number on the reattachment length is investigated. A parabolic entrance profile was used for pulsatile flow. It was found with amplitude of oscillation of one by Re=100 that the primary vortex breakdown through one pulsatile cycle. The wall shear rate in the separation zone varied markedly with pulsatile flows and the wall heat transfer remained relatively constant. The time-average pulsatile heat transfer at the walls was greater as with steady flow with the same mean Reynolds number.  相似文献   

15.
The present study investigates the pressure drop characteristics of rotating two-pass ducts. The duct has an aspect ratio (W/H) of 0.5 and a hydraulic diameter (D h ) of 26.67 mm. Rib turbulators are attached in the four different cross arrangements on the leading and trailing surfaces of the test ducts. The ribs have a rectangular cross section of 2 mm (e) × 3 mm (w) and a rib angle-of-attack of 70°. The pitch-to-rib-height ratio (p/e) is 7.5 and the rib-height-to-hydraulic-diameter ratio (e/D h ) is 0.075. The measured results for each region show that the highest pressure drop appears in the turning region in the stationary case, but appears in the upstream region of the second pass in the rotating case. The heat transfer and the pressure coefficients in the first pass are similar for the stationary and rotating cases in all the tested rib arrangements. After the turning region, however, the heat transfer and pressure drop are high in the cases with the cross NN- and PP-type ribs in the stationary ducts. In the rotating ducts, they are high in the cases with the cross NP- and PP-type ribs.  相似文献   

16.
This paper presents the results of a comprehensive numerical study to analyze conjugate, turbulent mixed convection heat transfer from a vertical channel with four heat sources, uniformly flush-mounted to one of the channel walls. The results are presented to study the effect of various parameters like thermal conductivity of wall material (k s), thermal conductivity of flush-mounted discrete heat source (k c), Reynolds number of fluid flow (Re s), modified Richardson number (Ri +) and aspect ratio (AR) of the channel. The standard k-ε turbulence model, modified by including buoyancy effects with physical boundary conditions, i.e. without wall functions, has been used for the analysis. Semi-staggered, non-uniform grids are used to discretise the two dimensional governing equations, using finite volume method. A correlation, encompassing a wide range of parameters, is developed for the non-dimensional maximum temperature (T *) using the asymptotic computational fluid dynamics (ACFD) technique.  相似文献   

17.
A numerical study of laminar forced convective flows of three different nanofluids through a horizontal circular tube with a constant heat flux condition has been performed. The effect of Al2O3 volume concentration 0 ≤ φ ≤ 0.09 in the pure water, water-ethylene glycol mixture and pure ethylene glycol as base fluids, and Reynolds number of 100 ≤ Re ≤ 2,000 for different power inputs in the range of 10 ≤ Q(W) ≤ 400 have been investigated. In this study, all of the nanofluid properties are temperature and nanoparticle volume concentration dependent. The governing equations have been solved using finite volume approach with the SIMPLER algorithm. The results indicate an increase in the averaged heat transfer coefficient with increasing the mass of ethylene glycol in the water base fluid, solid concentration and Reynolds number. From the investigations it can be inferred that, the pressure drop and pumping power in the nanofluids at low solid volumetric concentration (φ < 3%) is approximately the same as in the pure base fluid in the various Reynolds numbers, but the higher solid nanoparticle volume concentration causes a penalty drop in the pressure. Moreover, this study shows it is possible to achieve a higher heat transfer rate with lower wall shear stress with the use of proper nanofluids.  相似文献   

18.
Refrigerant R-410a flow distribution is experimentally studied in a test section simulating a parallel flow heat exchanger having vertical headers with two pass configuration. Tubes are heated to yield a test section outlet superheat of 5 °C with inlet quality of 0.3. Mass flux is varied from 50 kg/m2 s to 70 kg/m2 s. Effects of inlet and outlet locations are investigated in a search for an optimum configuration. Results show that, significant liquid flows through bottom channels, and less liquid is supplied to top channels. As for the inlet location, better flow distribution (pressure drop as well) is obtained for top inlet as compared with middle inlet. As for the outlet location, top or bottom outlet is better than middle outlet. Correlations are developed for the fraction of liquid or gas taken off by downstream channel as a function of header gas Reynolds number at immediate upstream. The correlations may be used to predict the liquid or gas distribution in a parallel flow heat exchanger having vertical headers. A novel thermal performance evaluation method, which accounts for tube-side flow mal-distribution is proposed.  相似文献   

19.
In the present study, the regionally-averaged heat transfer coefficients and flow temperature distributions were measured in an equilateral triangular channel with three different rib arrangements (α = 45, 90 and 135°). To measure regionally-averaged heat transfer coefficients in the channel, two rows of copper blocks and a single heater were installed on two ribbed walls. The fluid temperature distributions were obtained using a thermocouple-array. The rotation number ranged from 0.0 to 0.1 with a fixed Reynolds number of 10,000. For the 90° ribs, the heat transfer coefficients on the pressure side surface were increased significantly with rotation, while the suction side surface had lower heat transfer coefficients than the stationary channel. For the angled ribs, rib-induced secondary flow dominated the heat transfer characteristics and high heat transfer rates were observed on the regions near the inner wall for the 45° angled ribs and near the leading edge for the 135° angled ribs.  相似文献   

20.
Based on experimental investigations the present study evaluates instability and heat transfer phenomenon under condition of periodic flow boiling of water and ethanol in parallel triangular micro-channels. Tests were performed in the range of hydraulic diameter 100–220 μm, mass flux 32–200 kg/m2 s, heat flux 120–270 kW/m2, vapor quality x = 0.01–0.08. The period between successive events depends on the boiling number and decreases with an increase in the boiling number. The initial film thickness decreases with increasing heat flux. When the liquid film reached the minimum initial film thickness CHF regime occurred. Temporal variations of pressure drop, fluid and heater temperatures were periodic. Oscillation frequency is the same for the pressure drop, for the fluid temperature at the outlet manifold, and for the mean and maximum heater temperature fluctuations. All these fluctuations are in phase. The CHF phenomenon is different from that observed in a single channel of conventional size. A key difference between micro-channel heat sink and single conventional channel is amplification of parallel-channel instability prior to CHF. The dimensionless experimental values of the heat transfer coefficient are presented as the Nusselt number dependence on the Eotvos number and the boiling number.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏