首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Adaptive optics optical coherence tomography for retina imaging   总被引:1,自引:0,他引:1  
When optical coherence tomography (OCT) is used for human retina imaging, its transverse resolution is limited by the aberrations of human eyes. To overcome this disadvantage, a high resolution imaging system for living human retina, which consists of a time domain OCT system and a 37-elements adaptive optics (AO) system, has been developed. The AO closed loop rate is 20 frames per second, and the OCT has a 6.7-μm axial resolution. In this paper, this system is introduced and the high resolution imaging results for retina are presented.  相似文献   

2.
Optical coherence tomography using a frequency-tunable optical source   总被引:2,自引:0,他引:2  
We have developed a simple, wide-optical-bandwidth, high-resolution system for performing rapid optical frequency domain reflectometry measurements and applied it to multidimensional tomographic imaging. The source is a grating-tuned external cavity semiconductor laser with a tuning capability of 25 nm in 100 ms. We discuss system performance and show a two-dimensional optical coherence tomography image of a thin glass sandwich structure as a preliminary demonstration of the systems depth and resolution capabilities.  相似文献   

3.
We present the smallest reported side-viewing needle probe for optical coherence tomography (OCT). Design, fabrication, optical characterization, and initial application of a 30-gauge (outer diameter 0.31 mm) needle probe are demonstrated. Extreme miniaturization is achieved by using a simple all-fiber probe design incorporating an angle-polished and reflection-coated fiber-tip beam deflector. When inserted into biological tissue, aqueous interstitial fluids reduce the probe's inherent astigmatism ratio to 1.8, resulting in a working distance of 300 μm and a depth-of-field of 550 μm with beam diameters below 30 μm. The needle probe was interfaced with an 840 nm spectral-domain OCT system and the measured sensitivity was shown to be only 7 dB lower than that of a comparable galvo-scanning sample arm configuration. 3D OCT images of lamb lungs were acquired over a depth range of ~600 μm, showing individual alveoli and bronchioles.  相似文献   

4.
Wu J  Conry M  Gu C  Wang F  Yaqoob Z  Yang C 《Optics letters》2006,31(9):1265-1267
We report a novel forward-imaging optical coherence tomography (OCT), needle-probe paired-angle-rotation scanning OCT (PARS-OCT) probe. The probe uses two rotating angled gradient-index lenses to scan the output OCT probe beam over a wide angular arc (approximately 19 degrees half-angle) of the region forward of the probe. Among other advantages, this probe design is readily amenable to miniaturization and is capable of a variety of scan modes, including volumetric scans. To demonstrate the advantages of the probe design, we have constructed a prototype probe with an outer diameter of 1.65 mm and employed it to acquire four OCT images, with a 45 degrees angle between adjacent images, of the gill structure of a Xenopus laevis tadpole. The system sensitivity was measured to be 93 dB by using the prototype probe with an illumination power of 450 microW on the sample. Moreover, the axial and the lateral resolutions of the probe are 9.3 and 10.3-12.5 microm, respectively.  相似文献   

5.
严雪过  沈毅  潘聪  李鹏  丁志华 《物理学报》2016,65(2):24201-024201
本文报道了一种基于拉锥结构的全光纤型内窥光学相干层析成像探针. 基于大纤芯多模光纤的低光束发散特性, 使用大纤芯多模光纤代替透镜作为成像元件, 并在单模光纤与大纤芯多模光纤之间引入过渡拉锥段以减少插入损耗. 首先利用光学仿真软件(Rsoft)确定探针的最佳结构, 然后通过拉锥、切割以及熔接工艺实现探针制作, 并对探针的出射光束特性与插入损耗进行测量, 最后将该探针与扫频光学相干层析成像主系统联机, 对人体指尖皮肤及鸡气管壁组织进行成像. 该探针直径为250 μm, 不锈钢保护管外径为325 μm, 硬端长度1 cm, 插入损耗约为0.3 dB, 空气中有效成像范围达800 μm. 该探针为内窥光学相干层析成像技术在心血管疾病的应用提供了高紧凑度、高传输效率与高灵活性的选择.  相似文献   

6.
A novel flexible scanning optical probe is constructed with a finely etched optical fiber strung through a platinum coil in the lumen of a dissipative polymer. The packaged probe is 2.2 mm in diameter with a rigid length of 6mm when using a ball lens or 12 mm when scanning the fiber proximal to a gradient-index (GRIN) lens. Driven by constant high voltage (1-3 kV) at low current (< 5 microA), the probe oscillates to provide wide forward-viewing angle (13 degrees and 33 degrees with ball and GRIN lens designs, respectively) and high-frame-rate (10-140 fps) operation. Motion of the probe tip is observed with a high-speed camera and compared with theory. Optical coherence tomography (OCT) imaging with the probe is demonstrated with a wavelength-swept source laser. Images of an IR card as well as in vivo Doppler OCT images of a tadpole heart are presented. This optomechanical design offers a simple, inexpensive method to obtain a high-frame-rate forward-viewing scanning probe.  相似文献   

7.
We designed and fabricated an arrayed-waveguide grating (AWG) in silicon oxynitride as a spectrometer for spectral domain optical coherence tomography (SD-OCT). The AWG has a footprint of only 3.0 cm × 2.5 cm, operates at a center wavelength of 1300 nm, and has 78 nm free spectral range. OCT measurements are performed that demonstrate imaging up to a maximum depth of 1 mm with an axial resolution of 19 μm, both in agreement with the AWG design parameters. Using the AWG spectrometer combined with a fiber-based SD-OCT system, we demonstrate cross-sectional OCT imaging of a multilayered scattering phantom.  相似文献   

8.
Optical Coherence Tomography (OCT) is a new technology for performing high-resolution cross sectional imaging. OCT is analogous to ultrasound imaging, except that it uses light instead of sound. OCT can provide cross sectional images of tissue structure on the micron scale in situ and in real time. OCT functions as a type of optical biopsy and is a powerful imaging technology for medical diagnostics because unlike conventional histopathology which requires removal of a tissue specimen and processing for microscopic examination, OCT can provide images of tissue in situ and in real time. OCT can be used where standard excisional biopsy is hazardous or impossible, to reduce sampling errors associated with excisional biopsy, and to guide interventional procedures.  相似文献   

9.
EJ Min  JG Shin  JH Lee  Y Yasuno  BH Lee 《Optics letters》2012,37(15):3105-3107
We present a full range handheld probe type spectral domain optical coherence tomography (SD-OCT) method. Here, the sample arm is composed of a tilted fiber-optic cantilever scanner; thus, the phase shift concurrently occurs while sample scanning. With the phase shift, we could achieve a full range complex-conjugate-free OCT image with no additional phase shifters in the reference arm. To realize this technique, a magnetically actuated probe was adopted. Full range SD-OCT images of a pearl, human fingernail, and human tooth were subsequently obtained using this suggested probe. The scanning range and acquisition speed were 3?mm and 20 frames/s?, respectively.  相似文献   

10.
Min EJ  Shin JG  Kim Y  Lee BH 《Optics letters》2011,36(11):1963-1965
We propose the two-dimensional scanning probe operating with a single actuator, which is thought useful as a sample probe for optical coherence tomography (OCT). The probe was designed to use a single-body lensed fiber cantilever loaded with an iron-bead and driven by a single-solenoid actuator. Elliptic spiral trace patterns were achieved using off-axis magnetic fields of the solenoid. A three-dimensional OCT image was obtained for a scanning area of 3.8 mm × 3.4 mm at an acquisition speed of 16.7 s/V. Up to 27 Hz B-scan rate, the proposed probe worked well, and 1000 A-scans were made per each B-scan.  相似文献   

11.
Parallel optical coherence tomography is demonstrated using a 12-bit scientific-grade charge-coupled device array.A superluminescent diode in combination with a free-space Michelson interferometer was employed to achieve 10-μm axial resolution and 1.1-μm transverse resolution on a 902×575 μm2 field of view.We imaged a test mirror and bovine retinal tissue using a four-step phase shift method.  相似文献   

12.
An optical coherence tomography (OCT) system with 6 μm spatial resolution was employed to image the sites of fracture initiation and slow crack propagation in a fiber reinforced composite. Bar specimens (2 mm × 3 mm × 25 mm) of fiber reinforced composite were mechanically and thermally cycled to emulate oral conditions. The interior of the samples were analyzed prior and after the emulations. We analyzed the specimens that were intact after the loading cycling. The results demonstrated the capacity of the OCT technique to generate images of the sites fracture initiation, crack propagation, and regions surrounding the fracture, and it can be used in the future for quantitative analysis thus complementing other existing methods, with the main advantage of being non-destructive and non-invasive.  相似文献   

13.
Multi-channel detection is an effective way to improve data throughput of spectral-domain optical coherence tomography(SDOCT).However,current multi-channel OCT requires multiple detectors,which increases the complexity and cost of the system.We propose a novel multi-channel detection design based on a single spectrometer.Each camera pixel receives interferometric spectral signals from all the channels but with a spectral shift between two channels.This design effectively broadens the spectral ba...  相似文献   

14.
Forward-imaging instruments for optical coherence tomography   总被引:2,自引:0,他引:2  
We discuss the design and implementation of forward-imaging instruments for optical coherence tomography (OCT), which require the delivery, scanning, and collection of single-spatial-mode optical radiation. A hand-held surgical probe for use in open surgery can provide cross-sectional images of subsurface tissue before surgical incisions are made. A rigid laparoscope for minimally invasive surgical OCT imaging provides a simultaneous enface view of the area being imaged. OCT imaging is demonstrated on in vitro human specimens.  相似文献   

15.
Li X  Chudoba C  Ko T  Pitris C  Fujimoto JG 《Optics letters》2000,25(20):1520-1522
We describe a miniature optical coherence tomography (OCT) imaging needle that can be inserted into solid tissues and organs to permit interstitial imaging of their internal microstructures with micrometer scale resolution and minimal trauma. A novel rotational coupler with a glass capillary tube is also presented that couples light from a rotating single-mode fiber to a stationary one. A prototype needle with a 27-gauge (~410-mum) outer diameter has been developed and is demonstrated for in vivo imaging. The OCT needle can be integrated with standard excisional biopsy devices and used for OCT-guided biopsy.  相似文献   

16.
An experimental tracking optical coherence tomography (OCT) system has been clinically tested. The prototype instrument uses a secondary sensing beam and steering mirrors to compensate for eye motion with a closed-loop bandwidth of 1 kHz and tracking accuracy, to within less than the OCT beam diameter. The retinal tracker improved image registration accuracy to <1 transverse pixel (<60 microm). Composite OCT images averaged over multiple scans and visits show a sharp fine structure limited only by transverse pixel size. As the resolution of clinical OCT systems improves, the capability to reproducibly map complex structures in the living eye at high resolution will lead to improved understanding of disease processes and improved sensitivity and specificity of diagnostic procedures.  相似文献   

17.
Xie T  Mukai D  Guo S  Brenner M  Chen Z 《Optics letters》2005,30(14):1803-1805
A fiber-optic-bundle-based optical coherence tomography (OCT) probe method is presented. The experimental results demonstrate this multimode optical fiber-bundle-based OCT system can achieve a lateral resolution of 12 microm and an axial resolution of 10 microm with a superluminescent diode source. This novel OCT imaging approach eliminates any moving parts in the probe and has a primary advantage for use in extremely compact and safe OCT endoscopes for imaging internal organs and great potential to be combined with confocal endoscopic microscopy.  相似文献   

18.
Spectroscopic optical coherence tomography   总被引:12,自引:0,他引:12  
Spectroscopic optical coherence tomography (OCT), an extension of conventional OCT, is demonstrated for performing cross-sectional tomographic and spectroscopic imaging. Information on the spectral content of backscattered light is obtained by detection and processing of the interferometric OCT signal. This method allows the spectrum of backscattered light to be measured over the entire available optical bandwidth simultaneously in a single measurement. Specific spectral features can be extracted by use of digital signal processing without changing the measurement apparatus. An ultrabroadband femtosecond Ti:Al(2)O(3) laser was used to achieve spectroscopic imaging over the wavelength range from 650 to 1000 nm in a simple model as well as in vivo in the Xenopus laevis (African frog) tadpole. Multidimensional spectroscopic data are displayed by use of a novel hue-saturation false-color mapping.  相似文献   

19.
Second-harmonic optical coherence tomography   总被引:6,自引:0,他引:6  
Jiang Y  Tomov I  Wang Y  Chen Z 《Optics letters》2004,29(10):1090-1092
Second-harmonic optical coherence tomography, which uses coherence gating of second-order nonlinear optical responses of biological tissues for imaging, is described and demonstrated. Femtosecond laser pulses were used to excite second-harmonic waves from collagen harvested from rat tail tendon and a reference non-linear crystal. Second-harmonic interference fringe signals were detected and used for image construction. Because of the strong dependence of second-harmonic generation on molecular and tissue structures, this technique imparts contrast and resolution enhancement to conventional optical coherence tomography.  相似文献   

20.
Scanning optical coherence tomography (OCT) is limited in sensitivity and resolution by the restricted focal depth of the confocal detection scheme. Holoscopy, a combination of holography and Fourier-domain full-field OCT, is proposed as a way to detect photons from all depths of a sample volume simultaneously with uniform sensitivity and lateral resolution, even at high NAs. By using the scalar diffraction theory, as frequently applied in digital holographic imaging, we fully reconstruct the object field with depth-invariant imaging quality. In vivo imaging of human skin is demonstrated with an image quality comparable to conventionally scanned OCT.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号