共查询到18条相似文献,搜索用时 62 毫秒
1.
2.
3.
6.
7.
针对区域有源降噪问题,为获得更优降噪效果,根据实际次级通路传递函数,提出次级声源优化布放的有源控制系统并详细比较了两种次级声源优化布放算法与次级声源均匀布放的实际降噪效果。应用的第一种次级声源优化算法是l2范数约束的约束匹配追踪算法,第二种次级声源优化算法是l1范数约束的稀疏正则化方法。在全消声室中利用扬声器线阵进行多通道有源降噪实验研究,实验结果表明,在200~1000 Hz,次级声源优化布放的控制系统的平均降噪量比次级声源均匀布放的控制系统的平均降噪量多5 dB左右;在1100~1900 Hz,次级声源优化布放的控制系统的平均降噪量比次级声源均匀布放的控制系统的平均降噪量多11~13 dB左右,次级声源优化布放的控制系统的降噪量分布更加均匀且次级声源输出能量更小。此外,两种优化算法中,稀疏正则化方法的降噪效果更佳。 相似文献
8.
9.
10.
11.
Based on the analysis of active noise control system with multi-channel monopole secondary sources, a kind of compound secondary source is proposed in this paper. The proposed compound secondary source consists of two closely located monopole sources with their distance much smaller than a wavelength. The characteristics of the compound source are analyzed, and the performances of the active noise control system with the compound secondary sources on the monopole primary sound field and sound radiated by a plate are investigated both numerically and experimentally. It has been found that the proposed compound secondary sources control system can provide higher noise reduction for free field noise radiation control with the same number of control channels. It is shown that the better performance in noise reduction of the compound secondary sources control system is mainly due to the directivity of the secondary sources where the energy radiation pattern of the compound sources is similar to that of the primary sources. 相似文献
12.
13.
14.
This paper deals with the global reduction of axial flow fan noise in ducts in a building using a hybrid passive-active noise control method. The effectiveness of using an infra-red device as a reference signal source is also investigated. It is shown that using such a hybrid noise control system over an axial-flow fan reduces the overall sound pressure level by 5 dB(A) in the surrounding environment and global control of the blade passing frequency can also be achieved. This paper also shows that using an infra-red device as a reference signal source produces marginally better control as compared with using a microphone reference sensor. Moreover, long term stability is guaranteed and the possibility of acoustic feedback is eliminated. 相似文献
15.
A systematic analysis is proposed to predict the performance of a typical feedforward single channel ANC headset in terms of the delay, especially the non-causal delay caused by different noise coming directions. First, the performance of a non-causal feedforward system for a band-limited noise is analyzed by using a simplified pure delay model, where it is found that the noise reduction bandwidth is narrowed and the maximum noise reduction is decreased with the increase of the non-causal delay. Second, a systematic method is developed, which can be used to predict the system performance with measured primary and secondary path transfer functions in most practical sound fields and to study the effects of the control filter length and the path delay on the performance. Then, the causality of a typical feedforward active noise control headset with the primary source at 0° and 90° positions in an anechoic chamber is analyzed, and the performance for the two locations predicted by the systematic analysis is shown in good agreements with the experiment results. Finally, an experiment of a typical feedforward active noise control headset in a reverberation chamber is carried out, which shows the validity of the proposed systematic analysis for other more practical sound fields. 相似文献
16.
Active noise control (ANC) systems employing adaptive filters suffer from stability issues in the presence of impulsive noise. New impulsive noise control algorithms based on filtered-x recursive least square (FxRLS) algorithm are presented. The FxRLS algorithm gives better convergence than the filtered-x least mean square (FxLMS) algorithm and its variants but lacks robustness in the presence of high impulsive noise. In order to improve the robustness of FxRLS algorithm for ANC of impulsive noise, two modifications are suggested. First proposed modification clips the reference and error signals while, the second modification incorporates energy of the error signal in the gain of FxRLS (MGFxRLS) algorithm. The results demonstrate improved stability and robustness of proposed modifications in the FxRLS algorithm. However, another limitation associated with the FxRLS algorithm is its computationally complex nature. In order to reduce the computational load, a hybrid algorithm based on proposed MGFxRLS and normalized step size FxLMS (NSS-FXLMS) is also developed in this paper. The proposed hybrid algorithm combines the stability of NSS-FxLMS algorithm with the fast convergence speed of the proposed MGFxRLS algorithm. The results of the proposed hybrid algorithm prove that its convergence speed is faster than that of NSS-FxLMS algorithm with computational complexity lesser than that of FxRLS algorithm. 相似文献
17.
18.
In the adaptive feedback active noise control system based on the internal model control (IMC) structure, the reference signal is regenerated by synthesizing the error signal and the secondary signal filtered with the estimation of the secondary path, hence more computation load and extra programming are required. Motivated by the engineering truth that the primary noise cannot be completely cancelled in most practical active noise control applications and the error signal still contains some portions of the primary noise, a simplified adaptive feedback active noise control system is proposed in this paper, which adopts the error signal directly as the reference signal in an adaptive feedforward control system and utilizes the leaky filtered-x LMS algorithm to update the controller. The convergence properties of the proposed system are investigated and its advantages are discussed by comparing with other feedback control systems as well as the weakness. Finally, simulations and experiments are carried out to demonstrate the effectiveness of the proposed system. 相似文献