首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A monolithic C18-bonded silica rod column (Merck Chromolith) was compared to particle-based C18 and amide C16 sorbents in the HPLC separation of eight microcystins and nodularin-R. Two gradient mobile phases of aqueous trifluoroacetic acid modified with acetonitrile or methanol, different flow-rates and different gradient lengths were tested. The performance of the Chromolith column measured as the resolution of some microcystin pairs, the selectivity, efficiency (peak width) and peak asymmetry equalled, or exceeded, the performance of traditional particle-based columns. The Chromolith column allowed a shortening of the total analysis time to 4.3 min with a flow-rate 4 ml min(-1).  相似文献   

2.
The contribution of molecular diffusion to peak broadening was studied in a reversed-phase HPLC system, consisting of a monolithic silica C18 column and methanol-water mobile phase. Study on the band broadening effect of holding a solute in a column or elution at very low linear velocity of mobile phase allowed facile determination of the contribution of the molecular diffusion term. Less obstruction against molecular diffusion, or the faster axial band dispersion in a monolithic silica column than in a particle-packed column, was found both in mobile phase and in stationary phase.  相似文献   

3.
Separation of peptides by fast and simple two-dimensional (2D)-HPLC was studied using a monolithic silica column as a second-dimension (2nd-D) column. Every fraction from the first column, 5 cm long (2.1 mm ID) packed with polymer-based cation exchange beads, was subjected to separation in the 2nd-D using an octadecylsilylated (C18) monolithic sillica column (4.6 mm ID, 2.5 cm). A capillary-type monolithic silica C18column (0.1 mm ID, 10 cm) was also employed as a 2nd-D column with split flow/injection. Effluentof the first dimension (1st-D) was directly loaded into an injector loop of 2nd-D HPLC. UV and MS detection were successfully carried out at high linear velocity of mobile phase at 2nd-D using flow splitting for the 4.6 mm ID 2nd-D column, or with directconnection of the capillary column to the MS interface. Two-minute fractionation inthe 1st-D, 118-second loading, and 2-second injection by the 2nd-D injector, allowed one minute for gradient separation in the 2nd-D, resulting in a maximum peak capacity of about 700 within 40 min. The use of a capillary column in solvent consumption and better MS detectability compared to a larger-sized column. This kind of fast and simple 2D-HPLC utilizing monolithic silica columns will be useful for the separation of complex mixtures in a short time.  相似文献   

4.
A micellar electrokinetic chromatographic and a fast reversed‐phase liquid chromatographic method have been developed for determination of the purity of phenoxymethylpenicillin. The optimized running buffer composition was 40 mM phosphate–borate–125 mM SDS–3.5% (v/v) methanol. The HPLC method employed a monolithic silica C18 column and a mobile phase composed of phosphate buffer, pH 3.5, and ACN, the flow‐rate being 3.5 mL/min. Both methods were successfully validated. Linearity, intermediate precision, limits of quantitation, accuracy, and a good correlation of the HPLC and MEKC results were demonstrated. Both methods proved to be fast and reliable and sufficiently sensitive. A combination of the two methods can be very useful in impurity profiling.  相似文献   

5.
The feasibility of using a monolithic column as the analytical column in conjunction with high-flow direct-injection liquid chromatography/tandem mass spectrometry (LC/MS/MS) to increase productivity for quantitative bioanalysis has been investigated using plasma samples containing a drug and its epimer metabolite. Since the chosen drug and its epimer metabolite have the same selected reaction monitoring (SRM) transitions, chromatographic baseline separation of these two compounds was required. The results obtained from this monolithic column system were directly compared with the results obtained from a previously validated assay using a conventional C18 column as the analytical column. Both systems have the same sample preparation, mobile phases and MS conditions. The eluting flow rate for the monolithic column system was 3.2 mL/min (with 4:1 splitting) and for the C18 column system was 1.2 mL/min (with 3:1 splitting). The monolithic column system had a run time of 5 min and the conventional C18 column system had a run time of 10 min. The methods on the two systems were found to be equivalent in terms of accuracy, precision, sensitivity and chromatographic separation. Without sacrificing the chromatographic separation, sensitivity, accuracy and precision of the method, the reduced run time of the monolithic column method increased the sample throughput by a factor of two.  相似文献   

6.
A rapid, sensitive and reproducible HPLC method was developed and validated for the analysis of haloperidol and its three main metabolites in human plasma. The analysis was carried out on a monolithic silica column (Chromolith Performance RP-18e, 100 x 4.6 mm). The mobile phase consisted of sodium phosphate (0.1 m, pH 3.5)-acetonitrile (80:20, v/v) at a flow rate of 2.0 mL/min. UV detection at 230 nm was used, with the detection limits of these compounds ranging from 2 to 5 ng. The separation factors of all studied compounds were in the range 2.30-16.32, while the resolution factors were from 1.00 to 5.37.  相似文献   

7.
A micellar electrokinetic chromatographic (MEKC) method and a fast reversed-phase liquid chromatographic one have been developed for determining the purity of ampicillin. MEKC separation of ampicillin and its related substances was performed with the use of an untreated fused-silica capillary and 40 mM phosphate-borate buffer, pH 7.5 containing 75 mM SDS. The HPLC method employed a monolithic silica C18 column and a mobile phase composed of phosphate buffer, pH 5.2 and ACN, the flow rate being 4.0 mL/min. Both methods were successfully validated. Linearity, relative response factors, limits of quantitation, intermediate precision, and accuracy were evaluated. The methods proved to be fast, reliable, and sufficiently sensitive and, accordingly, well-suited for control of purity of ampicillin substance, injections, and capsules. A combination of both methods can be very useful in the confirmation of impurity profiles.  相似文献   

8.
Development and validation of an RP-HPLC method for determination of levetiracetam in pharmaceutical tablets is described. The separation and quantification of levetiracetam and caffeine (internal standard) were performed using a single analytical procedure with two different types of stationary phases, conventional Phenomenex Gemini C18 (100 x 4.6 mm, 5 microm) and Merck Chromolith Performance RP18e (100 x 4.6 mm, macropore size 2 mm, micropore size 13 nm) monolithic silica. Five-microliter aliquots of samples were injected into the system and eluted using water-acetonitrile (90 + 10, v/v) mobile phase pumped at the rate of 1 mL/min. The analyte peaks were detected at 200 nm using a diode array detector with adequate resolution. Validation studies were performed using the method recommended by the International Conference on Harmonization, the U.S. Pharmacopeia, and AOAC INTERNATIONAL, which includes accuracy, precision, range, limits, robustness, and system suitability parameters. Levetiracetam and caffeine were detected in about 7 min using the conventional column, whereas less than 5 min was required when the monolithic column was used. Calibration plots had r values close to unity in the range of 0.8-8.0 microg/mL. Assay of levetiracetam in a tablet formulation was demonstrated as an application to real samples.  相似文献   

9.
In-tube solid-phase microextraction (SPME) has successfully been coupled to capillary LC, and further an automated in-tube SPME system has been developed using a commercially available HPLC auto-sampler. However, an open tubular capillary column with a thick film of polymer (stationary phase) is unfavorable because the ratio of the surface area of coating layer contacted with sample solution to the volume of the capillary column is insufficient for mass transfer. A highly efficient SPME column is. therefore, required. We introduced a C18-bonded monolithic capillary column that was used for in-tube SPME. The column consisted of continuous porous silica having a double-pore structure. Both the through-pore and the meso-pore were optimized for in-tube SPME, and the optimized capillary column was connected to an HPLC injection valve for characterization. The results demonstrated that the pre-concentration efficiency is excellent compared with the conventional in-tube SPME. The novel method for both introduction and concentration of the samples was effective. satisfactory and suitable for use in the SPME medium.  相似文献   

10.
Cat's claw is a large woody vine with hook‐like thorns, and has been traditionally used to treat inflammatory disorders in South and Central America. In this study, a rapid, validated high‐performance liquid chromatographic (HPLC) method using a silica monolithic column was developed for the simultaneous determination of oxindole alkaloids, namely rhynchophylline, pteropodine, isomitraphylline and isopteropodine, in cat's claw. The ionic liquid‐based microwave‐assisted extraction (ILMAE), considered as an environmentally friendly and powerful tool, was first applied in the extraction of oxindole alkaloids. To optimize the HPLC method, the stationary phases, pH values of mobile phase and flow rates were investigated. The validated HPLC method using a Monolithic RP18e column (100 × 4.6 mm) enables these analytes to be separated almost twice as fast as with a conventional particulate column (~16 vs ~30 min) with limits of quantification and detection of 0.5 and 0.15 μg/mL, respectively. The ILMAE conditions were optimized by the Taguchi orthogonal array design. In comparison with conventional water boiling extraction, ILMAE offers almost four times higher yields within an extremely short extraction time. The developed HPLC coupled with ILMAE method could be efficient and practical for rapid determination of oxindole alkaloids in cat's claw.  相似文献   

11.
In this work, monolithic silica columns with the C4, C8, and C18 chemistry and having various macropore diameters and two different mesopore diameters are studied to access the differences in the column efficiency under isocratic elution conditions and the resolution of selected peptide pairs under reversed-phase gradient elution conditions for the separation of peptides and proteins. The columns with the pore structural characteristics that provided the most efficient separations are then employed to optimize the conditions of a gradient separation of a model mixture of peptides and proteins based on surface chemistry, gradient time, volumetric flow rate, and acetonitrile concentration. Both the mesopore and macropore diameters of the monolithic column are decisive for the column efficiency. As the diameter of the through-pores decreases, the column efficiency increases. The large set of mesopores studied with a nominal diameter of approximately 25 nm provided the most efficient column performance. The efficiency of the monolithic silica columns increase with decreasing n-alkyl chain length in the sequence of C18相似文献   

12.
Since the appearance of monolithic silica, much work has been done describing the properties of monolithic silica columns. Meanwhile the transferability of analytical methods from conventional to monolithic silica columns has been intensively investigated [1-5]. RP HPLC method development strategies for conventional columns should be updated or scaled to meet the higher performing monolithic column technology. Because of the high permeability of monolithic silica columns it should be possible to decrease the time for method development by applying high isocratic flow rates. Here we suggest a clear strategy for method development using monolithic columns. The strategy will be applicable for various sample compositions, e. g., acidic, basic, or neutral. The applicability of monolithic columns for especially complex separations of basic mixtures without the need of using a highly basic mobile phase that harms the column will be pointed out in this work. This work will describe in detail the actual method development process. For better understanding of our strategy, the influence of flow rate, column length, mobile phase composition, pH, and temperature will be discussed. Details about the application of a flow program will be mentioned.  相似文献   

13.
We developed a novel, convenient and low-cost one-pot strategy for preparing a zeolitic imidazolate framework-8 (ZIF-8)–silica hybrid monolithic column by adding ZIF-8 directly to a polymer solution of the silica matrix. The simulated stationary phase and monolithic column prepared under optimal conditions were characterized using X-ray diffraction, scanning electron microscopy, Fourier-transform infrared spectroscopy, thermogravimetric analysis nitrogen physisorption and zeta potential. The results obtained confirmed the successful introduction of ZIF-8 into the silica monolithic column, and the prepared monolithic column exhibited good permeability and physicochemical stability. A capillary electrochromatography method was developed based on a ZIF-8–silica hybrid monolithic column through which 15 mixed amino acids, 4 neutral compounds, 4 nipagin esters and 2 chlorinated fungicides were separated in 14, 5, 7 and 6 min, respectively, under optimal conditions. The relative standard deviations retention times and column efficiencies in run-to-run, day-to-day and column-to-column varied in the ranges of 1.90%–2.21%, 2.13%–2.51% and 3.08%–6.65%, respectively, which demonstrated that ZIF-8–silica hybrid monolithic column exhibited satisfactory reproducibility and stability. The incorporation of ZIF-8 into a silica monolithic column is a promising method for preparing novel monolithic columns composed of a metal–organic framework.  相似文献   

14.
Huang K  Zhou N  Chen B 《色谱》2011,29(10):957-961
利用溶胶-凝胶法,经过烷氧基硅烷的水解、硅羟基的缩聚、凝胶化、陈化、中孔制备、干燥和表面修饰等步骤制备了全氟癸基修饰的毛细管硅胶整体柱。采用该整体柱对全氟辛烷磺酸(PFOS)进行萃取富集,考察其富集特性和效率,并与传统的C18毛细管硅胶整体柱进行对比。结果表明,全氟癸基修饰毛细管硅胶整体柱(15 cm×75 μm)对PFOS具有更高的吸附量和更好的富集选择性,其平均吸附量可以达到75 ng;样品中PFOS的质量浓度为0.25 mg/L时,富集倍数平均可以达到29倍。此全氟癸基修饰毛细管硅胶整体柱对PFOS具有良好的萃取富集性能,可用于水质中痕量PFOS的萃取富集。  相似文献   

15.
To overcome the limitations of solid-phase extraction, we developed a device comprising a spin column packed with octadecyl silane-bonded monolithic silica for extracting amphetamines and methylenedioxyamphetamines from urine. Urine (0.5mL), buffer (0.4mL), and methoxyphenamine (internal standard) were directly put into the preactivated column. The column was centrifuged (3000rpm, 5min) for sample loading and washed. The adsorbed analytes were eluted and analyzed by high-performance liquid chromatography, without evaporation. The results were as follows: linear curves (drug concentrations of 0.2-20microg/mL); correlation coefficients >0.99; detection limit, 0.1microg/mL. The proposed method is not only useful for drugs from biological materials but also highly reproducible for the analysis of these drugs in urine.  相似文献   

16.
Reduction of through-pore size and skeleton size of a monolithic silica column was attempted to provide high separation efficiency in a short time. Monolithic silica columns were prepared to have various sizes of skeletons (approximately 1-2 microm) and through-pores (approximately 2-8 microm) in a fused-silica capillary (50-200 microm I.D.). The columns were evaluated in HPLC after derivatization to C18 phase. It was possible to prepare monolithic silica structures in capillaries of up to 200 microm I.D. from a mixture of tetramethoxysilane and methyltrimethoxysilane. As expected, a monolithic silica column with smaller domain size showed higher column efficiency and higher pressure drop. High external porosity (> 80%) and large through-pores resulted in high permeability (K = 8 x 10(-14) -1.3 x 10(-12) m2) that was 2-30 times higher than that of a column packed with 5-mirom silica particles. The monolithic silica columns prepared in capillaries produced a plate height of about 8-12 microm with an 80% aqueous acetonitrile mobile phase at a linear velocity of 1 mm/s. Separation impedance, E, was found to be as low as 100 under optimum conditions, a value about an order of magnitude lower than reported for conventional columns packed with 5-microm particles. Although a column with smaller domain size generally resulted in higher separation impedance and the lower total performance, the monolithic silica columns showed performance beyond the limit of conventional particle-packed columns under pressure-driven conditions.  相似文献   

17.
A monolithic spin column was developed for the extraction of analytes from biological materials. This column was constructed by packing a monolithic silica disk into a spin column. Sample loading, washing, and elution of the target drugs were accomplished simply by centrifugation of the column. Opiates and benzodiazepines are abused throughout the world. Identification and quantification of these drugs is very important to solve crimes or the cause of death. Three opiates (morphine, codeine, and dihydrocodeine) were extracted from urine and serum by using the column. After conversion to trimethylsilyl derivatives of the opiates by vigorous mixing with the derivatizing reagent, the solution was subjected to GC/MS. A linear curve was observed for opiates from 10 to 2500 ng/mL in urine and 5 to 1200 ng/mL in serum, respectively (correlation coefficient > 0.996). For benzodiazepines, the hydroxyl metabolites of triazolam and etizolam were extracted from urine using the column, and the eluate was directly analyzed by HPLC/MS without evaporation. The LOD values were at the ppb level, with RSD values lower than 15%. The proposed methods were successfully applied to clinical and forensic cases, and good agreement of results was obtained compared to conventional methods.  相似文献   

18.
Analytical scale silica monoliths are commercially limited to three column selectivities (bare silica, C8 and C18). An in situ modification is reported in detail to overcome this barrier and allow for any functionality of choice to be bonded to the silica surface of the monolithic stationary phase support. The modification method was conducted on a commercial bare silica column to bond the C18 moiety to the silica surface through a silylation reaction. The C18 type of stationary phase was chosen, as this is the most commonly bonded functionality for the majority of stationary phases used for high-performance liquid chromatography (HPLC) separations. The C18-modified monolith’s performance was compared to a commercial C18 monolithic and a particle packed column of the same analytical scale column dimensions (100 × 4.6 mm). The modified C18 monolith proved to be of high quality with an efficiency of 73,267 N m?1, fast analysis times (operated at flow rates up to 3 mL min?1 using a conventional 400 bar HPLC system) and improved resolution of a set of polar and non-polar substituted aromatics in comparison to a commercial C18 monolith.  相似文献   

19.
A chloropropyl-functionalized silica (CP-silica) hybrid monolithic column was synthesized within the confines of a capillary via the sol–gel process using tetramethoxysilane (TMOS) and (3-chloropropyl)-trimethoxysilane (CPTMS) as the precursors. The resulting CP-silica hybrid monolith inside the capillary showed homogeneous macroporous morphology and was well attached to the inner wall of the capillary. The obtained CP-silica hybrid monolithic capillary column demonstrated the inherent hydrophobic property and could be applied as a reversed-phase stationary phase in CEC directly. Due to the great chemical reactivity of the incorporated chloro groups on the hybrid silica monolithic matrix, the chloropropyl moieties on the surface of the hybrid silica monolith matrix could be conveniently further modified by a tertiary amine of N,N-dimethyl-N-dodecylamine (DMDA) via the nucleophilic substitution reaction at 70 °C to introduce a dodecyl groups (C12) onto the CP-silica hybrid monolithic matrix. The resulting C12-silica hybrid monolithic column not only demonstrated the significantly enhanced hydrophobic property in the separation of alkylbenzenes in reversed-phase capillary electrochromatography (RP-CEC), but also the strong electroosmotic flow (EOF) in a wide pH range. Five alkylbenzenes could be baseline separated in 3 min with column efficiency ranging from 189 700 to 221 000 N/m with a 70% ACN running buffer in CEC.  相似文献   

20.
A new rapid, sensitive and validated HPLC method has been developed for the determination of methylxanthines and their metabolites in asthmatic patients. The method was initiated by using spiked urine samples on a silica monolithic column as a novel packing material. The mobile phase consisted of 10 mM potassium dihydrogen phosphate buffer/methanol (87.5:12.5 v/v), at a flow rate 1 mL/min. Detection was set at 274 nm. The LOQ for all the compounds ranged from 14 to 41 ng/mL. Excellent linearity was achieved over the studied range of concentration with correlation coefficients 0.9991–0.9998 (n = 6). The developed method was validated by precision and accuracy with RSD <2.55%. On extraction of the drugs and metabolites from the urine samples high recoveries were achieved ranging from 82.06 to 98.34% w/w on RP18 cartridges and methanol/chloroform (20:80 v/v) as the extraction solvent. This method has advantages over other methods using conventional C18 packings.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号