首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In this study an alternative method based on surface plasmon resonance is proposed for in-situ monitoring of variation in the refractive index of a test sample. A wavelength-modulated light source and an unequal-path-length optical configuration heterodyne interferometer are used to detect the phase difference change, which can then be used to estimate the change in the refractive index of a test sample. The experimental results demonstrate a phase stability of 0.02°. The resolution power of the refractive index is 1.5 × 10− 6 RIU. This method has several advantages over previously used methods such as simple optical setup, easier operation in real time, and low cost.  相似文献   

2.
Q Chen  H Luo  S Wang  F Wang 《Optics letters》2012,37(14):2916-2918
A method for refractive index of air measurement is presented based on surface plasmon resonance (SPR) and phase detection using a dual-frequency laser interferometer. Theoretical analyses indicate that the phase-difference variation of the measurement signal versus the reference signal is linear with refractive index of air (RIA) fluctuation, and the calculation formula of RIA is derived. The structure design of the self-adaptive SPR sensor greatly reduces the measurement error resulting from the incident angle shift and improves the sensitivity. The experiments show that measurement uncertainty of 10(-6) order has been achieved when phase detection precision is 0.1°. The phenomenon of sudden phase variation during air pumping and air filling, which is caused by temperature fluctuation, is discussed.  相似文献   

3.
对水-二甲基亚砜二元混合溶液质量分数和温度与折射率的关系进行了理论和实验研究,对几种经典模型的拟合结果进行了比较,给出了适合水-二甲基亚砜混合溶液的经验公式。对水性金溶胶-二甲基亚砜混合溶液质量分数和温度对局域表面等离子体共振峰值波长的影响进行了理论和实验研究,结果表明:水性金溶胶-二甲基亚砜混合溶液质量分数对共振峰值波长的调节有较好的线性关系和较大的调节范围,当温度从20 ℃增大到60 ℃,混合溶液金溶胶的共振峰值波长增加了1367 pm,温度敏感度为34 pm/K,在0%~100%的质量分数范围内,混合溶液金溶胶的共振峰值波长平均产生8.5103 pm的增长。  相似文献   

4.
对水-二甲基亚砜二元混合溶液质量分数和温度与折射率的关系进行了理论和实验研究,对几种经典模型的拟合结果进行了比较,给出了适合水-二甲基亚砜混合溶液的经验公式。对水性金溶胶-二甲基亚砜混合溶液质量分数和温度对局域表面等离子体共振峰值波长的影响进行了理论和实验研究,结果表明:水性金溶胶-二甲基亚砜混合溶液质量分数对共振峰值波长的调节有较好的线性关系和较大的调节范围,当温度从20 ℃增大到60 ℃,混合溶液金溶胶的共振峰值波长增加了1367 pm,温度敏感度为34 pm/K,在0%~100%的质量分数范围内,混合溶液金溶胶的共振峰值波长平均产生8.5103 pm的增长。  相似文献   

5.
赵华君 《中国物理 B》2012,21(8):87104-087104
The surface plasmon resonance gas sensor is presented for refractive index detection using nano-cavity antenna array.The gas sensor monitors the changes of the refractive index by measuring the spectral shift of the resonance dip,for modulating the wavelength of incident light.It is demonstrated that minute changes in the refractive index of a medium close to the surface of a metal film,owing to a shift in the resonance dip of the wavelength,can be detected.The average detection sensitivity is about 3200 nm/RIU(refractive index units),which is more than twice that of a metal grating-based gas sensor.The reflectivity of the surface plasmon resonance dip is only ~ 0.03%,and the full widths at half maximum(FWHMs) of bandwidth of the angle and wavelength are ~ 0.20° and 4.71nm,respectively.  相似文献   

6.
龙拥兵  张剑  汪国平 《物理学报》2009,58(11):7722-7726
对基于表面等离子体激元共振(SPR)的飞秒抽运探测技术进行了系统地数字分析.计算结果表明,利用SPR技术可将飞秒抽运探测信号强度ΔR/R提高2—3个数量级,其提高的比例依赖于金属膜的厚度和探测光的入射角,其中R和ΔR分别为探测光反射率的总量和变化量.特别地,对于金属-吸收介质体系,金属膜的介电常数变化对ΔR的影响仅为吸收介质影响的2%,所以ΔR/R主要反应吸收介质中的动力学过程,因此该技术对研究表面和界面的超 关键词: 超快光学 表面等离子体共振 飞秒抽运探测技术 信号强度  相似文献   

7.
A new analytical method based on the surface plasmon resonance (SPR) technique is presented, with which SPR curves for both wavelength and angular modulations can be obtained simultaneously via only a single scan of the incident angle. Using this method, the SPR responses of TiO2-coated Cu films are characterized in the wavelength range from 600 nm to 900 nm. For the first time, we determine the effective optical constants and the thicknesses of TiO2-coated Cu films using the SPR curves of wavelength modulation. The sensitivities of prism-based SPR refractive index sensors using TiO2-coated Cu films are investigated theoretically for both wavelength and angular modulations, the results show that in the case of sensitivity with wavelength modulation, TiO2-coated Cu films are not as good as the Au film, however, they are more suitable than the Au film for SPR refractive index sensors with angular modulation because a higher sensitivity can be achieved.  相似文献   

8.
The dispersive characteristics of surface plasmon polaritons (SPPs) supported by a periodically corrugated boundary between vacuum and a negative refractive index, isotropic material were studied theoretically by numerical solution of a dispersion equation. SPP dispersion curves were correlated with the optical response of the corrugated boundary in frequency regions where SPPs can be excited by a normally incident plane wave. Abrupt reflectivity variations, characterized by the presence of a near unity maximum and an almost zero minimum, were found in regions where the boundary without corrugation exhibits low reflectivity and rather featureless reflectivity curves.  相似文献   

9.
施伟华  尤承杰  吴静 《物理学报》2015,64(22):224221-224221
利用光子晶体光纤结构的灵活性和性能的优越性, 设计了一种基于D形光子晶体光纤的折射率和温度传感器. 在D形光子晶体光纤表面抛磨并镀上金纳米薄膜, 作为表面等离子体共振传感通道用来测量液体折射率; 在包层的一个空气孔中填充温敏液体甲苯, 作为定向耦合通道实现对温度的测量. 进一步的数值计算发现, 基于定向耦合效应的温度传感和基于表面等离子体共振的折射率传感相互独立, D形光子晶体光纤同时进行折射率和温度传感检测. 在各向异性的完美匹配层边界条件下利用全矢量有限元法对该传感器特性进行了数值研究, 发现D形光子晶体光纤的空气孔直径决定了定向耦合吸收峰的中心波长和温度传感的灵敏度, 金薄膜的厚度和D形结构的抛磨深度仅影响表面等离子体共振峰的相对强度. 结果表明: 该传感器在-10–80 ℃的温度范围内具有11.6 nm/℃的温度灵敏度, 在1.34–1.44折射率范围内折射率灵敏度最高可达26000 nm/RIU.  相似文献   

10.
提出了一种基于表面等离子体共振(SPR)效应增强的光子晶体光纤折射率传感器。该传感器结构通过光纤熔接机拼接光子晶体光纤(PCF),在光子晶体光纤中间引入一个空气孔形成PCF-空气孔-PCF的光纤传感结构,随后使用磁控溅射镀膜工艺在其表面沉积一层薄金膜制备而成。实验探究了折射率及温度对传感器的响应。结果表明,在1.333~1.389的折射率范围内,所提出的传感器的平均折射率灵敏度为2 142.52 nm,且测量线性度为0.981,品质因子约13.10。实验结果表明该传感器对温度不敏感。相比于无空气孔的PCF传感结构,引入的空气孔增强了SPR效应,使得传感器拥有良好的共振峰深度。得益于上述优势,该类型传感器有望在生物医学、环境监测等领域得到应用。  相似文献   

11.
This work presents a new surface plasmon resonance (SPR) instrument based on Kretschmann configuration. This device acquires and processes the reflected SPR image of the sample by using a webcam together with an image processing algorithm that transforms the RGB image in numeric values and correlates the integrated intensity with the refractive index of the solution. Experimental signals were compared with theoretical values and it was found an excellent agreement. In addition, the applicability of the instrument was tested by measuring the refractive index of solutions in a continuous flow mode. Excellent stability and sensitivity of the signal were found in the presence of small changes of the refractive index.  相似文献   

12.
In this study,a new method utilizing surface plasmon resonance(SPR) sensing technology based on the phase and angular interrogations for measuring the refractive index of a liquid prism is presented.An orthogonal sample box that combined the functions of a prism,cell box,and mirror is adopted to simplify the system and provide the convenience to implement the phase and angular interrogations.The angular interrogation is achieved by the motorized rotation stage with the new sample box,and the phase interrogation is achieved by the linear polarization interferometry between the s-and p-polarization components.The amplitude reflectivity and the phase angle,which are the functions of the incident angle,are obtained by the reflection intensity and the interference intensity of the lights directly.A sensitivity of 7.5 × 10.7 refractive index unit(RIU)/0.1° and a dynamic range of 0.5 RIU are obtained experimentally and theoretically.  相似文献   

13.
深入浅出地分析了金属表面等离体子振荡形成的机理,利用拉普拉斯方程得到了半无限金属、金属薄膜和球状纳米金属颗粒的表面等离体子振荡频率。  相似文献   

14.
This paper proposes an optical method for measuring small displacements using the surface plasmon resonance (SPR) heterodyne interferometry. A heterodyne light beam reflected by a mirror passes through a hemisphere glass and then enters into a surface plasmon resonance apparatus at the resonant angle. A small displacement of the mirror will introduce a phase-difference variation between p- and s-polarizations of the light emerging from the SPR apparatus. The phase-difference variation can be precisely measured with the heterodyne interferometric technique, and the associated displacement can be estimated. The feasibility of this method was verified by experiment, and the displacement measurement resolution of about 1.4 nm over a traveling range of 6 μm was achieved. Our method of measurement has the merits of both common-path interferometry and heterodyne interferometry.  相似文献   

15.
徐跃  薛鹏  张瑞  陈媛媛 《应用光学》2023,44(1):226-233
研究了基于波长调制的螺旋形塑料光纤(plastic optical fiber, POF)表面等离子体共振(surface plasmon resonance, SPR)折射率传感器。采用机械热压和扭曲法将塑料光纤制备成螺旋形,在螺旋形POF上通过磁控溅射蒸镀一定厚度(约50 nm)的金属薄膜来激励SPR效应,从而形成螺旋形POF-SPR传感器。通过对螺旋形POF-SPR传感器的结构进行修饰,研究不同结构参数对折射率传感特性的影响。实验结果表明:由厚度为500μm扁平形POF扭制、螺纹数为4的螺旋形POF-SPR传感器具有较好的线性度和折射率传感特性,在折射率为1.335~1.400范围内测得的灵敏度为1 262 nm/RIU。该传感器具有成本较低、制备简单、结构稳定等优点。  相似文献   

16.
结合物理光学原理和表面等离子体共振(SPR)角度传感器,提出了可以突破衍射极限的纳米间距检测方法。在理论上建立起纳米间距和位相改变量之间的函数关系,借助于SPR角度传感器的高灵敏性,提出通过检测出射光束振动方向的p分量和s分量的位相差值来实现纳米间距的实时检测。模拟结果显示:纳米间距改变量从-0.5~0.5μm变化时,位相改变量可实现-150°~150°的变化,检测灵敏度〉1 nm。该检测方法能够实现10 nm以下间距的灵敏检测,且具有结构简单,易于操作,实时检测的特点。  相似文献   

17.
利用LabVIEW编写硬件控制软件,搭建了基于表面等离激元共振原理的光强探测型液体折射率测量实验平台.实验测量纯水和纯酒精的表面等离激元共振的共振角分别与理论计算数据相吻合,证明该系统测量的共振角数值能正确地反映液体折射率的变化.利用该系统测量了不同浓度的酒精-水混合液的折射率.  相似文献   

18.
We report on the optical absorption properties of as prepared gold naoparticles of different shapes and sizes measured by photoacoustic (PA) method. The gold nanoparticles of two different shapes (dots, rods) have been prepared using the seed mediated growth method. The shape and the size of these different nanoparticles were determined by STM measurements. PA spectra show the splitting of the surface plasmon resonance (SPR) into two modes (transverse and longitudinal) in case of gold nanorods. The increase in the aspect ratio of the nanorods leads to clear redshifts of the longitudinal SPR. These shifts were used to determine the dielectric constant of the surrounding medium and its variation with the aspect ratios.  相似文献   

19.
The surface photoelectric effect and the surface plasmon resonances appear when a p/transverse magnetic polarized laser hits a gas-solid interface. We model this effect in the long wave length (LWL) domain (λvac > 10 nm,  < 124 eV) by combining the Ampère-Maxwell equation, written in classical approximation, with the material equation for the susceptibility. The resulting model, called the vector potential from the electron density (VPED), calculates the susceptibility as a product of the bulk susceptibility and the electron density of the actual system. The bulk susceptibility is a sum of the bound electron scalar susceptibility taken from the experiment and of the conduction electron non-local isotropic susceptibility tensor in a jellium metal (Lindhard, 1954 [1]). The electron density is the square of the wave function solution of the Schrödinger equation. The analysis of observables, the reflectance R and the photoelectron yield Y as well as the induced charge density permits to identify and characterize the multipole surface plasmon resonance of Al(111) appearing at ωm ∼ 0.8ωp or 11-12 eV.  相似文献   

20.
Wu SY  Ho HP  Law WC  Lin C  Kong SK 《Optics letters》2004,29(20):2378-2380
A high-sensitivity surface plasmon resonance (SPR) biosensor based on the Mach-Zehnder interferometer design is presented. The novel feature of the new design is the use of a Wollaston prism through which the phase quantities of the p and s polarizations are interrogated simultaneously. Since SPR affects only the p polarization, the signal due to the s polarization can be used as the reference. Consequently, the differential phase between the two polarizations allows us to eliminate all common-path phase noise while keeping the phase change caused by the SPR effect. Experimental results obtained from glycerin-water mixtures indicate that the sensitivity limit of our scheme is 5.5 x 10(-8) refractive-index units per 0.01 degrees phase change. To our knowledge, this is a significant improvement over previously obtained results when gold was used as the sensor surface. Such an improvement in the sensitivity limit should allow SPR biosensors to become a possible replacement for conventional biosensing techniques based on fluorescence. Monitoring of the bovine serum albumin (BSA) binding reaction with BSA antibodies is also demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号