首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The determination of isotopes of uranium by alpha spectrometry in different environmental components (sediments, soil, water, plants and phosphogypsum) is presented and discussed in this paper. The alpha spectrometry is a very convenient and good technique for activity concentration of natural uranium isotopes (234U, 235U, 238U) in environmental samples and provides the most accurate determination of isotopic activity ratios between 234U and 238U. The analysis were provided information about possible sources of high concentrations of uranium in the examined sites determined by anthropogenic sources. The calculation of values 234U/238U in all analyzed samples was applied to identifying natural or anthropogenic uranium origin. Activity concentration of uranium isotopes in analyzed environmental samples shows that measurement of uranium levels is of great importance for environmental and safety assessment especially in contaminated areas (phosphogypsum waste heap).  相似文献   

2.
In the paper the results of determination of 210Po, 238U and 239+240Pu radionuclides in the biggest Polish rivers are presented. Our results show the Vistula and the Oder as well as three Pomeranian Rivers are important sources of these radionuclides for the southern Baltic Sea.  相似文献   

3.
The concentrations of uranium and the234U/238U ratio in natural Syrian phosphates were measured by gamma- and alpha-ray spectroscopy. The234U/238U activity ratios showed that uranium in Syrian phosphate is in equilibrium under the climatic conditions. Soma anomalous observations in these ratios were explained by earlier leaching of the phosphate by water (rain or other).  相似文献   

4.
High-resolution alpha-particle spectrometry was performed on three uranium materials enriched in 235U. Besides the 235U peaks, separate peaks belonging to impurity traces of 234U could be quantified. Relying on the isotopic composition of the uranium, as determined by mass spectrometry, the ratio of the half-lives of 238U and 235U was determined via the activity ratio of 234U and 235U in the materials. As an intermediate link, the 234U/238U half-life ratio was taken from published mass spectrometric analyses of ‘secular equilibrium’ uranium material. The resulting half-life ratio T 1/2(238U)/T 1/2(235U) = 6.351±0.031 is in agreement with the commonly adopted half-life values determined by Jaffey et al.  相似文献   

5.
The uranium concentration and the234U/238U,235U/238U activity ratios were studied in water samples from Jucar River, using low-level -spectrometry. The effects of pH, temperature and salinity were considered and more detailed sampling was done in the neighbourhood of Cofrentes Nuclear Plant (Valencia, Spain). Changes were observed in the uranium concentration with the salinity and the234U/238U activity ratio was found to vary with pH. Leaching and dilution, which depend on pH and salinity, are the probable mechanisms for these changes in the concentration of uranium and the activity ratios.  相似文献   

6.
A study of the radioactive content of drinking mineral bottled water in Poland was carried out. 210Po,238U and 234U activity concentrations were determined by alpha-spectrometry with low-level-activity silicon detectors. The results revealed that the mean concentration of 210Po,238U and 234U in analyzed water sample were 1.28, 0.80 and 0.80 mBq.dm-3, respectively. The effective doses due to the polonium and uranium emissions were calculated for bottled drinking water.  相似文献   

7.
234U/238U α-activity ratios determined by α-spectrometry (AS) and those calculated from the atom ratio data using the half-life values are compared in some of the isotopic reference materials of uranium and a few other uranium samples. For α-spectrometry, electrodeposited sources were prepared and a large area passivated ion implanted (IPE) detector (450 mm2) was used for recording the α-spectra. The isotopic composition of U was determined by thermal ionisation mass spectrometry (TIMS) and the recommended half-life values of234U and238U were used to calculate the α-activity ratio. It is observed that234U/238U α-activity ratios calculated from the atom ratio data are consistently high, with a mean difference of about 5%, when compared to the α-spectrometry results. This discrepancy warrants confirmation by a few more laboratories and suggests redetermination of the half-life values of234U and238U.  相似文献   

8.
238U, 234U and 210Po activity concentrations were determined in beer in Poland by alpha-spectrometry with low-level activity silicon detectors. The results revealed that the mean concentrations of 238U, 234U and 210Po in the analyzed beer samples were 4.63, 4.11 and 4.94 mBq·dm−3, respectively, the highest in Tyskie (5.71 for 210Po, 5.06 for 234U and 6.11 for 238U) and the lowest in Lech (2.49 for 210Po). The effective radiation dose due to uranium and polonium ingestions by beer was calculated and were compared to the effective radiation dose from drinking water. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

9.
Activity concentrations of 238U, 235U and 234U were determined in different sources of drinking water at the Obuasi gold mines and its surrounding areas in Ghana. Water samples collected from the mines and its surrounding areas were analyzed using direct gamma-ray spectrometry and neutron activation analysis. The 234U/238U and 235U/238U ratios were calculated and the mean values range from 1.27 to 1.38 and from 0.044 to 0.045 respectively. The average 234U/238U ratio was from 1.27 for groundwater to 1.38 for treated water, demonstrating the lack of equilibrium. The average 235U/238U activity ratio is 0.045, indicating that only natural uranium was detected in the samples investigated.  相似文献   

10.
Zheng J  Yamada M 《Talanta》2006,68(3):932-939
The determination of uranium is important for environmental radioactivity monitoring, which investigates the releases of uranium from nuclear facilities and of naturally occurring radioactive materials by the coal, oil, natural gas, mineral, ore refining and phosphate fertilizer industries, and it is also important for studies on the biogeochemical behavior of uranium in the environment. In this paper, we describe a quadrupole ICP-MS (ICP-QMS)-based analytical procedure for the accurate determination of U isotope ratios (235U/238U atom ratio and 234U/238U activity ratio) in sediment samples. A two-stage sample cleanup using anion-exchange and TEVA extraction chromatography was employed in order to obtain accurate and precise 234U/238U activity ratios. The factors that affect the accuracy and precision of U isotope ratio analysis, such as detector dead time, abundance sensitivity, dwell time and mass bias were carefully evaluated and corrected. With natural U, a precision lower than 0.5% R.S.D. for 235U/238U atom ratio and lower than 2.0% R.S.D. for 234U/238U activity ratio was obtained with less than 90 ng uranium. The developed analytical method was validated using an ocean sediment reference material and applied to an investigation into the uranium isotopic compositions in a sediment core in a brackish lake in the vicinity of U-related nuclear facilities in Japan.  相似文献   

11.
Nearshore surface sediments from various locations of the West Coast of India were leached by saturated ammonium carbonate solution for the extraction of uranium isotopes. The reagent chosen was found to have high efficiency for leaching uranium isotopes without attacking the mineral core of the sediment particle. The activity ratios of234U/238U are in the range of 1.11 to 1.14 and the activity ratios of235U/235U are in the range of 0.045 to 0.047. The respective activity ratios in leachates, and residues after removal of surface organic matter from the sediment particles by treatment with hydrogen peroxide and 0.05M HCl, revealed disequilibrium between238U and234U only in the surface organic matter. The activity ratios of234U/238U and235U/238U have also been determined in some seawater samples from the Arabian Sea.  相似文献   

12.
The activity concentrations of 234U and 238U in thermal groundwater, deep well water and river water samples from Central Poland were determined. Concentration of 234U and 238U in the examined waters varied from <0.013 (LLD) to 16.8 mBq/dm3 and from <0.013 (LLD) to 45.5 mBq/dm3 respectively. The highest uranium activity concentrations were measured in the thermal groundwater from Mszczonow and Cieplice, while the lowest were observed in thermal ground water from Uniejow and Poddebice. In thermal groundwater from Skierniewice, uranium activity concentrations were below lower limit of detection (0.013 mBq/dm3). The 234U/238U activity ratio varied from 0.37 (Cieplice) to 1.30 (Poddebice well water).  相似文献   

13.
Within this work, the activity concentrations of uranium isotopes (234U, 235U, and 238U) were analyzed in some of the popular and regularly consumed Hungarian mineral-, spring-, therapeutic waters and tap waters. Samples were selected randomly and were taken from different regions of Hungary (Balaton Upland, Bükk Mountain, Somogy Hills, Mez?föld, and Lake Hévíz). Concentration (mBq L?1) of 234U, 235U, and 238U in the waters varied from 1.1 to 685.2, from <0.3 to 7.9, and from 0.8 to 231.6 respectively. In general, the highest uranium concentrations were measured in spring waters, while the lowest were found in tap waters. In most cases radioactive disequilibrium was observed between uranium isotopes (234U and 238U). The activity ratio between 234U and 238U varies from 0.57 to 4.97. The calculated doses for the analyzed samples of spring water are in the range 0.07–32.39 μSv year?1 with an average 4.32 μSv year?1. This is well below the 100 μSv year?1 reference level of the committed effective dose recommended by WHO and the EU Council. The other naturally occurring alpha emitting radionuclides (226Ra and 210Po) will be analyzed later to complete the dose assessment. This study provides preliminary information for consumers and authorities about their internal radiological exposure risk due to annual intake of uranium isotopes via water consumption.  相似文献   

14.
Geochemical radioanalytical studies of groundwater were performed in the valleys of Villa de Reyes and San Luis Potosi (Mexico). The experiments were designed to measure radon and uranium content and234U/238U activity ratio in groundwater samples taken from wells in these sites and at the Nuclear Center of Salazar, Mexico.222Rn content varied depending on the sample source, reaching a maximum value of 235 pCi/l; uranium concentration results were less than 1 g/1 and234U/238U activity ratios were close to equilibrium.  相似文献   

15.
Due to the importance of water in human life, its quality must be strictly controlled; so simple and reliable analytical methods must be available. For this purpose a rapid procedure for the determination of uranium isotopes in natural water samples with elevated salinity was adopted. It was tested in 16 water samples from Upper and Lower Silesia Regions in Poland. Water samples had salinity in a range of 290–26,925 mg l− 1.In water samples the concentrations of 234U and 238U ranged from 2.07 to 52.08 mBq l– 1 and from 2.18 to 43.38 mBq l– 1 respectively, while 235U level was below MDA (0.7 mBq l− 1).The isotopic ratio of 234U/238U varies in the range from 0.949 to 3.344 in all investigated waters which means that there is usually no radioactive equilibrium between the parent nuclide 238U and its daughter product 234U.These results do not show a correlation between total dissolved solids (TDS) values and concentration of dissolved uranium isotopes.Committed effective dose for adults due to uranium intake as a result of drinking water usage was in range of 0.15–3.29 µSv y− 1 with an average value of 1.09 µSv y− 1 far below the 100 µSv y− 1 WHO recommendation.  相似文献   

16.
In the course of measurements of uranium contamination in rivers of the Guadiana basin we have found the logical contamination near the uranium mines and a234U/238U ratio near 1 in the neighbourhood of the sources. With distance we find not only the expected decreasing contamination but also higher values of the activity ratio234U/238U. This observation seems to contradict the usual explanation of preferential leaching of234U as origin of the general234U enrichment of ground water.  相似文献   

17.
The 234U/238U isotope ratio has been widely used as a tracer for geochemical processes in underground aquifers. Quadrupole-based inductively coupled plasma mass spectrometry (ICP-MS) equipped with a high-efficiency nebulizer and a membrane desolvator was employed for the determination of 234U/238U isotope ratios in natural water samples. The instrumental limit of detection for 234U was at the low pg L−1 level with very low sample consumption. Measurement precision (234U/238U) was 3–5% for bottled mineral water with elevated uranium concentration (>1 μg L−1). For the analysis of groundwater samples from the Almonte-Marisma underground aquifer (Huelva, Spain), uranium was stripped from stainless steel planchets that had previously been used as radiometric counting sources for alpha-particle spectrometry. Potential spectral interferences from other metals introduced during the dissolution were investigated. Matrix-matched blank solutions were needed to subtract the background on 234U due to the formation of platinum argides, and to allow for mass bias correction and background correction. The Pt appears to be an impurity present in the stainless steel, either as a minor component by itself or after extraction from the anode and a subsequent uranium electrodeposition. The 234U/238U isotope ratio data were in very good agreement with those of alpha spectrometry, while precision was improved by a factor of up to 10 and counting time was reduced down to ~20 min (10 replicate measurements).  相似文献   

18.
A series of leaching experiments with HF, HCl, HNO3 were carried out on samples of uranium minerals (uraninite and carnotite samples). Anomalously high234U/238U ratios were observed in some uranium fractions. The observed234U/238U activity ratios varied between the values of 1.019±0.155 and 6.210±0.504 (Ci/Ci), while the bulk carnotite sample had an activity ratio of 1.010±0.005 (Ci/Ci). These results are interpreted as due to alpha-recoil effect and changes in oxidation state of uranium.  相似文献   

19.
Uranium concentration in groundwater reflect both redox conditions and uranium content in host rock. In the present study an attempt has been made to study the uranium concentration and activity ratios of uranium isotopes to present the geochemical conditions of the groundwater in Malwa region of Punjab state, India and the reason for high uranium levels and variation of activity ratios from secular equilibrium conditions. Uranium concentration in groundwater samples was found to be in the range of 13.9 ± 1.2 to 172.8 ± 12.3 μg/l with an average value of 72.9 μg/l which is higher than the national and international guideline values. On the basis of uranium concentration, the groundwater of the study region may be classified as oxidized aquifer on normal uranium content strata (20 %) or oxidized aquifer on enhanced uranium content strata (80 %). The 238U, 235U and 234U isotopic concentration in groundwater samples was found to be in the range of 89.2–1534.5, 4.4–68.5, and 76.4–1386.2 mBq/l, respectively. Activity ratios of 234U/238U varies from 0.94 to 1.85 with a mean value of 1.11 which is close to unity that shows secular equilibrium condition. High value of 234U isotope than 238U may be due to alpha recoil phenomenon. The plot of AR of 234U/238U against the total uranium content in log scale reveals that the groundwaters of the study region either belongs to stable accumulation or normal oxidized aquifer.  相似文献   

20.
The234U/238U and235U/238U ratios from uranium compounds by -spectrometry technique have been obtained. Ten commercially available uranium reagents were analyzed. The well-separated peaks corresponding to uranium isotopes are evident, providing an energy spectrum of the -particles of uranium isotopes. It was found that some commerical uranium salts were depleted in234U and235U.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号