1.
The highest precision in the determination of nuclear and atomic masses can be achieved by Penning trap mass spectrometry. The mass value is obtained through a measurement of the cyclotron frequency of the stored charged particle. Two different approaches are used at the Penning trap mass spectrometer TRIGA-TRAP for the mass determination: the destructive Time-Of-Flight Ion Cyclotron Resonance (TOF-ICR) technique and the non-destructive Fourier Transform Ion Cyclotron Resonance (FT-ICR) method. New developments for both techniques are described, which will improve the detection efficiency and the suppression of contaminations in the case of TOF-ICR. The FT-ICR detection systems will allow for the investigation of an incoming ion bunch from a radioactive-beam facility on the one hand, and for the detection of a single singly charged ion in the Penning trap on the other hand.  相似文献   

2.
TITAN is an on-line facility dedicated to precision experiments with short-lived radioactive isotopes, in particular mass measurements. The achievable resolution on mass measurement, which depends on the excitation time, is limited by the half life of the radioactive ion. One way to bypass this is by increasing the charge state of the ion of interest. TITAN has the unique capability of charge-breeding radioactive ions using an electron-beam ion trap (EBIT) in combination with Penning trap mass spectrometry. However, the breeding process leads to an increase in energy spread, ??E, which in turn negatively influences the mass uncertainty. We report on the development of a cooler Penning trap which aims at reducing the energy spread of the highly charged ions prior to injection into the precision mass measurement trap. Electron and proton cooling will be tested as possible routes. Mass selective cooling techniques are also envisioned.  相似文献   

3.
The low-energy beam and ion trap facility LEBIT at NSCL/MSU is at present the only facility where precision experiments are performed with stopped rare isotope beams produced by fast-beam fragmentation. LEBIT combines high-pressure-gas stopping with advanced ion manipulation techniques to provide brilliant low-energy beams. So far these beams have mainly been used for mass measurements on short-lived rare isotopes with a 9.4T Penning trap mass spectrometer. Recent examples include 70m Br , located at the proton dripline, 32Si and the iron isotopes 63-65Fe . While the measurement of 32Si helps to solve a long-standing dispute over the validity of the isobaric multiplet mass equation (IMME) for the A = 32 , T = 2 multiplet, the mass measurements of 65m,g Fe marked the first time a nuclear isomeric state has been discovered by Penning trap mass spectrometry.  相似文献   

4.
The TITAN facility at TRIUMF-ISAC will use four ion traps with the primary goal of determining nuclear masses with high precision, particularly for short lived isotopes with lifetimes down to approximately 10 ms. The design value for the accuracy of the mass measurement is 1 ×10???8. The four main components in the facility are an RF cooler/buncher (RFCT) receiving the incoming ion beam, an electron beam ion trap (EBIT) to breed the ions to higher charge states, a cooler Penning trap (CPET) to cool the highly charged ions, and finally the measurement Penning trap (MPET) for the precision mass determination. Additional goals for this system are laser spectroscopy on ions extracted from the RFCT and beta spectroscopy in the EBIT (in Penning trap mode) on ions that are purified using selective buffer gas cooling in the CPET. The physics motivation for the mass measurements are manifold, from unitarity tests of the CKM matrix to nuclear structure very far from the valley of stability, nuclear astrophysics and the study of halo-nuclei. As a first measurement the mass of 11Li will be determined. With a lifetime of 8.7 ms and a demonstrated production rate of 4×104 ions/sec at ISAC the goal for this measurement at TITAN is a relative uncertainty of 5×10???8. This would check previous conflicting measurements and provide information for nuclear theory and models.  相似文献   

5.
A novel method to determine independent yields in particle-induced fission employing the ion guide technique and ion counting after a Penning trap has been developed. The method takes advantage of the fact that a Penning trap can be used as a precision mass filter, which allows an unambiguous identification of the fission fragments. The method was tested with 25MeV and 50MeV proton-induced fission of 238U . The data is internally reproducible with an accuracy of a few per cent. A satisfactory agreement was obtained with older ion guide yield measurements in 25MeV proton-induced fission. The results for Rb and Cs yields in 50MeV proton-induced fission agree with previous measurements performed at an isotope separator equipped with a chemically selective ion source.  相似文献   

6.
A novel technique for a direct and coherent measurement of the modified cyclotron frequency of an ion in a Penning trap at energies close to the thermal cooling limit is presented. This allows a rapid and both precise and accurate determination of the free-space cyclotron frequency in real Penning traps despite the existence of electric and magnetic field imperfections and relativistic shifts. The demonstrated performance paves the way for considerably improved bound-state g-factor measurements on the 10?ppt level and mass measurements in the 1?ppt range and possibly below.  相似文献   

7.
We describe how a single hydrogen-like ion (C5+) is prepared, cooled with the method of resistive cooling and non-destructively detected with the image-current technique in a cryogenic Penning trap at T = 4 K. The storage time for C5+-ions in the cryogenically pumped vacuum chamber is longer than six months. The experimental techniques of preparing, cooling and detecting highly-charged ions in a Penning trap are relevant for precision experiments such as g-factor measurements, mass spectroscopy and laser spectroscopy. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

8.
A novel approach to mass measurements at the 10?9 level for short-lived nuclides with half-lives well below one second is presented. It is based on the projection of the radial ion motion in a Penning trap onto a position-sensitive detector. Compared with the presently employed time-of-flight ion-cyclotron-resonance technique, the novel approach is 25-times faster and provides a 40-fold gain in resolving power. Moreover, it offers a substantially higher sensitivity since just two ions are sufficient to determine the ion’s cyclotron frequency. Systematic effects specific to the technique that can change the measured cyclotron frequency are considered in detail. It is shown that the main factors that limit the maximal accuracy and resolving power of the technique are collisions of the stored ions with residual gas in the trap, the temporal instability of the trapping voltage, the anharmonicities of the trapping potential and the uncertainty introduced by the conversion of the cyclotron to magnetron motion.  相似文献   

9.
The low-energy beam and ion trap facility LEBIT at the NSCL at MSU has demonstrated that rare isotopes produced by fast-beam fragmentation can be slowed down and prepared such that precision experiments with low-energy beams are possible. For this purpose high-pressure gas-stopping is employed combined with advanced ion manipulation techniques. Penning trap mass measurements on short-lived rare isotopes have been performed with a 9.4 T Penning trap mass spectrometer. Examples include 66As, which has a half-live of only 96 ms, and the super-allowed Fermi-emitter 38Ca, for which a mass accuracy of 8 ppb (280 eV) has been achieved. The high accuracy of this new mass value makes 38Ca a new candidate for the test of the conserved vector current hypothesis.   相似文献   

10.
Savard  G. 《Hyperfine Interactions》1993,81(1-4):135-142
A tandem Penning trap system, the ISOLTRAP, is now used at the on-line mass separator ISOLDE at CERN, Geneva, for accurate mass measurements of short-lived nuclei. The mass of the stored ions is measured by the determination of the cyclotron frequency c=qB/m in theB=6 T magnetic field of the trap. A new technique has been developed and implemented to allow reliable high-efficiency loading of the trap with radioactive heavy ions.  相似文献   

11.
ISOLTRAP is a Penning trap mass spectrometer for high-precision mass measurements on short-lived nuclides installed at the on-line isotope separator ISOLDE at CERN. The masses of close to 300 radionuclides have been determined up to now. The applicability of Penning trap mass spectrometry to mass measurements of exotic nuclei has been extended considerably at ISOLTRAP by improving and developing this double Penning trap mass spectrometer over the past two decades. The accurate determination of nuclear binding energies far from stability includes nuclei that are produced at rates less than 100 ions/s and with half-lives well below 100ms. The mass-resolving power reaches 107 corresponding to 10keV for medium heavy nuclei and the uncertainty of the resulting mass values has been pushed down to below 10-8. The article describes technical developments achieved since 1996 and the present performance of ISOLTRAP.  相似文献   

12.
13.
The precise determination of the 3He/3H mass ratio, and hence the tritium ??-decay endpoint energy E 0, is of relevance for the measurement of the electron anti-neutrino mass performed by the Karlsruhe Tritium Neutrino experiment (KATRIN). By determining this ratio to an uncertainty of 1 part in 1011, systematic errors of E 0 can be checked in the data analysis of KATRIN. To reach this precision, a Penning Trap Mass Spectrometer was constructed at the University of Washington and has been transferred to the Max Planck Institute for Nuclear Physics in Heidelberg at the end of 2008. Since then it is called MPIK/UW-PTMS. Special design features are the utilization of an external ion source and a double trap configuration. The external Penning ion source efficiently ionizes the helium and tritium gas and can give superior elimination of unwanted ion species compared to the previously utilized in-trap-ionization by electrons from a field-emission point. The design as a double Penning trap allows a faster measurement procedure. This should help to avoid problems resulting from long-term drifts in the experimental conditions. Additionally, the laboratory in Heidelberg was carefully prepared to have very stable environmental conditions. Experimental challenges and the first Heidelberg results with the new spectrometer are presented.  相似文献   

14.
The LEBIT (Low Energy Beam and Ion Trap) facility is the only Penning trap mass spectrometry (PTMS) facility to utilize rare isotopes produced via fast-beam fragmentation. This technique allows access to practically all elements lighter than uranium, and in particular enables the production of isotopes that are not available or that are difficult to obtain at isotope separation on-line facilities. The preparation of the high-energy rare-isotope beam produced by projectile fragmentation for low-energy PTMS experiments is achieved by gas stopping to slow down and thermalize the fast-beam ions, along with an rf quadrupole cooler and buncher and rf quadrupole ion guides to deliver the beam to the Penning trap. During its first phase of operation LEBIT has been very successful, and new developments are now underway to access rare isotopes even farther from stability, which requires dealing with extremely short lifetimes and low production rates. These developments aim at increasing delivery efficiency, minimizing delivery and measurement time, and maximizing use of available beam time. They include an upgrade to the gas-stopping station, active magnetic field monitoring and stabilization by employing a miniature Penning trap as a magnetometer, the use of stored waveform inverse Fourier transform (SWIFT) to most effectively remove unwanted ions, and charge breeding.  相似文献   

15.
Doubly charged silver clusters Agn 2+, n=21, 22, 23, are produced by electron bombardment of an Agn + ensemble stored in a Penning trap. After mass selection the clusters are subjected to collision induced dissociation. The fragmentation channels are determined by time-of-flight mass spectrometry after ejection of the resulting ion ensemble from the trap. Monomer evaporation is the only decay path observed. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   

16.
Penning traps are powerful instruments for the precise and accurate mass determination of rare isotopes. At present, many Penning trap facilities installed at radioactive beam facilities provide key data for nuclear astrophysics, for the study of nuclear structure evolution far from stability, and the test of fundamental interactions. This article summarizes the present status and current limits in the field of high-precision Penning trap mass measurements on short-lived exotic ions.  相似文献   

17.
Mass selective buffer gas cooling is a technique used for ions that are stored in a Penning trap. The technique can be applied to all elements and the mass resolving power achieved has proven to be sufficient to resolve isobars. When not only a few but 106 and more ions are stored at the same time, space charge starts to play a dominant role for the spatial distribution. In addition, the observed cyclotron frequency is shifted. This work investigates these effects by numerical calculations. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

18.
Dipolar and single-phase two-electrode quadrupolar detection schemes have been investigated at a Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) setup built for the KATRIN experiment at the Max-Planck-Institute for Nuclear Physics (MPIK) in Heidelberg. We present first experimental results of 7Li?+? signals from a cylindrical Penning trap configuration for both detection schemes. While the prominent signal of the conventional dipolar detection scheme marks the reduced cyclotron frequency, the main signal for the quadrupolar detection appears at the sum of the reduced cyclotron frequency and the magnetron frequency. For ideal trapping fields, this sum frequency equals the ion cyclotron frequency ?? c ?=?qB/(2??m). Sidebands due to the combined motions of the cyclotron mode and magnetron mode are observed by quadrupolar detection which allows the determination of the respective combinations of eigenfrequencies.  相似文献   

19.
Detailed investigations of laser–ion interactions require well-defined ion targets and detection techniques for high-sensitivity measurements of reaction educts and products. To this end, we have designed and built the High-Intensity Laser-Ion Trap Experiment Penning trap setup, which features various ion-target preparation techniques including selection, cooling, compression, and positioning as well as destructive and non-destructive measurement techniques to determine the number of stored ions for all charge states individually and simultaneously. We have recently performed first commissioning experiments of ion deceleration and dynamic ion capture with highly charged ion bunches from an electron beam ion source. We have characterized our single-pass non-destructive ion counter in detail and were able to determine the ion velocity as well as the number of ions from the signals acquired.  相似文献   

20.
Laser spectroscopy of trapped ions is likely to be limited by the availability of suitable detection systems for fluorescence photons, especially in the infrared transition frequency domain. This restriction can be circumvented when ions are stored in a Penning trap with an additional magnetic field inhomogeneity which couples the ion oscillation frequencies to the oscillation energies in a well-defined way. In such a case, laser cooling (or heating) on the optical transition of interest can be detected electronically by a corresponding shift of the ion oscillation frequency. Thereby, the transition of interest can be determined with high accuracy using only a single stored ion and in absence of any optical detection system.  相似文献   