A multilaboratory study was conducted to compare performance of the GeneQuence DNA hybridization (DNAH) method incorporating new 24 h enrichment protocols and reference culture procedures for detection of Salmonella spp. in select foods. Six food types (raw ground turkey, raw ground beef, dried whole egg, milk chocolate, walnuts, and dry pet food) were tested by the DNAH method and by the culture methods of either the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) or the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA/BAM). Fifteen laboratories participated in the study. Four of the foods tested (raw ground turkey, dried whole egg, milk chocolate, and dry pet food), showed no statistically significant differences in performance between the DNAH method and the reference procedure as determined by Chi square analysis. Sensitivity rates for the DNAH method ranged from 92 to 100%. The DNAH method, with the specific enrichment protocol evaluated, was found to be ineffective for detection of Salmonella spp. in walnuts. For raw ground beef, results from one trial showed a statistically significant difference in performance, with more positives obtained by the reference method. However, evidence suggests that the difference in the number of positives was likely due to lack of homogeneity of the test samples rather than to DNAH method performance.  相似文献   

2.
Reveal Salmonella 2.0 is an improved version of the original Reveal Salmonella lateral flow immunoassay and is applicable to the detection of Salmonella enterica serogroups A-E in a variety of food and environmental samples. A Performance Tested Method validation study was conducted to compare performance of the Reveal 2.0 method with that of the U.S. Department of Agriculture-Food Safety and Inspection Service or U.S. Food and Drug Administration/Bacteriological Analytical Manual reference culture methods for detection of Salmonella spp. in chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, raw shrimp, a ready-to-eat meal product, dry pet food, ice cream, spinach, cantaloupe, peanut butter, stainless steel surface, and sprout irrigation water. In a total of 17 trials performed internally and four trials performed in an independent laboratory, there were no statistically significant differences in performance of the Reveal 2.0 and reference culture procedures as determined by Chi-square analysis, with the exception of one trial with stainless steel surface and one trial with sprout irrigation water where there were significantly more positive results by the Reveal 2.0 method. Considering all data generated in testing food samples using enrichment procedures specifically designed for the Reveal method, overall sensitivity of the Reveal method relative to the reference culture methods was 99%. In testing environmental samples, sensitivity of the Reveal method relative to the reference culture method was 164%. For select foods, use of the Reveal test in conjunction with reference method enrichment resulted in overall sensitivity of 92%. There were no unconfirmed positive results on uninoculated control samples in any trials for specificity of 100%. In inclusivity testing, 102 different Salmonella serovars belonging to serogroups A-E were tested and 99 were consistently positive in the Reveal test. In exclusivity testing of 33 strains of non-salmonellae representing 14 genera, 32 were negative when tested with Reveal following nonselective enrichment, and the remaining strain was found to be substantially inhibited by the enrichment media used with the Reveal method. Results of ruggedness testing showed that the Reveal test produces accurate results even with substantial deviation in sample volume or device development time.  相似文献   

3.
The VIDAS Salmonella (SLM) Easy Salmonella method is a specific enzyme-linked fluorescent immunoassay performed in the automated VIDAS instrument. The VIDAS Easy Salmonella method is a simple 2-step enrichment procedure, using pre-enrichment followed by selective enrichment in a newly formulated broth, SX2 broth. This new method was compared in a multilaboratory collaborative study to the U.S. Food and Drug Administration's Bacteriological Analytical Manual, Chapter 5 method for five food matrixes (liquid egg, vanilla ice cream, spinach, raw shrimp, and peanut butter) and the U.S. Department of Agriculture's Microbiology Laboratory Guidebook 4.04 method for deli turkey. Each food type was artificially contaminated with Salmonella at three inoculation levels. A total of 15 laboratories representing government, academia, and industry, throughout the United States, participated. In this study, 1583 samples were analyzed, of which 792 were paired replicates and 791 were unpaired replicates. Of the 792 paired replicates, 285 were positive by both the VIDAS and reference methods. Of the 791 unpaired replicates, 341 were positive by the VIDAS method and 325 were positive by the cultural reference method. A Chi-square analysis of each of the six food types was performed at the three inoculation levels tested. For all foods evaluated, the VIDAS Easy SLM method demonstrated results comparable to those of the reference methods for the detection of Salmonella.  相似文献   

4.
The BAX System PCR assay for Salmonella detection in foods was previously validated as AOAC Research Institute (RI) Performance Tested Method (PTM) 100201. New studies were conducted on beef and produce using the same media and protocol currently approved for the BAX System PCR assay for E. coli O157:H7 multiplex (MP). Additionally, soy protein isolate was tested for matrix extension using the U.S. Food and Drug Administration-Bacteriological Analytical Manual (FDA-BAM) enrichment protocols. The studies compared the BAX System method to the U.S. Department of Agriculture culture method for detecting Salmonella in beef and the FDA-BAM culture method for detecting Salmonella in produce and soy protein isolate. Method comparison studies on low-level inoculates showed that the BAX System assay for Salmonella performed as well as or better than the reference method for detecting Salmonella in beef and produce in 8-24 h enrichment when the BAX System E. coli O157:H7 MP media was used, and soy protein isolate in 20 h enrichment with lactose broth followed by 3 h regrowth in brain heart infusion broth. An inclusivity panel of 104 Salmonella strains with diverse serotypes was tested by the BAX System using the proprietary BAX System media and returned all positive results. Ruggedness factors involved in the enrichment phase were also evaluated by testing outside the specified parameters, and none of the factors examined affected the performance of the assay.  相似文献   

5.
A collaborative study was conducted to compare the VIDAS Salmonella (SLM) with Rappaport-Vassiliadis (RV) method for detection of Salmonella in foods to the current standard method presented in the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM) and the culture method presented in AOAC's Official Methods of Analysis. The VIDAS SLM with RV method uses tetrathionate broth in combination with RV medium in place of selenite cystine broth for selective enrichment, thereby eliminating the hazardous waste issue for laboratories. Twenty five laboratories participated in the evaluation, each testing one or more of 8 test products: nonfat dry milk, dried egg, soy flour, lactic casein, milk chocolate, raw ground pork, raw ground turkey, and raw peeled shrimp. Results of the study showed no significant differences in the numbers of confirmed positive samples with the VIDAS SLM with RV procedure and the BAM/AOAC culture procedure. The VIDAS SLM with RV method was effective for rapid detection of Salmonella in foods. It is recommended that AOAC INTERNATIONAL modify the VIDAS Salmonella SLM procedure to include the RV method.  相似文献   

6.
Reveal Salmonella Enteritidis (SE) is a lateral flow-based immunodiagnostic assay used for rapid detection of Salmonella enterica serovar Enteritidis from pooled shell eggs and environmental samples. This assay uses highly specific antibodies to accurately detect S. Enteritidis. Studies were conducted to compare the performance of this test against reference procedures for detection of S. Enteritidis from both pooled shell eggs and environmental samples. Pooled shell eggs were inoculated with low levels ofS. Enteritidis and were enriched according to the procedure prescribed by the U.S. Food and Drug Administration. Uninoculated samples were included in each trial. Reveal SE exhibited 100% sensitivity and 100% specificity in comparison to the reference method in all trials. An abbreviated 48 h/(no hold) enrichment procedure was also developed and validated for detection ofS. Enteritidis from pooled shell egg samples. This shortened enrichment procedure can be used in conjunction with the Reveal SE test and offers a significant enrichment time savings of 96 h. Chi-square analysis revealed that there was no significant difference between the abbreviated Reveal method and the reference procedure for detection ofS. Enteritidis from pooled shell egg samples. Out of 245 natural drag swabs screened internally, only three samples tested Reveal SE positive and were confirmed by the reference procedure, resulting in 100% sensitivity and 100% specificity. An external laboratory screened 147 poultry house environmental samples and obtained 35 Reveal SE confirmed positives for Reveal SE sensitivity of 100% and specificity of 90%. Inoculation trials with drag swabs resulted in 96% sensitivity and 100% specificity. Thus, these data demonstrate that Reveal SE is a highly sensitive and specific assay for the detection of S. Enteritidis from both pooled shell eggs and environmental samples.  相似文献   

7.
The RapidChek SELECT Salmonella Enteritidis Test System was validated for the detection of Salmonella Enteritidis (SE) in poultry house drag swabs, shell egg pools, and chicken carcass rinsates. The method utilizes RapidChek SELECT Salmonella (AOAC PTM License No. 080601) proprietary primary and secondary enrichment media. Following enrichment, an immunochromatographic test strip is inserted into the tube containing the secondary enrichment broth, developed for 10 min, and interpreted. Salmonella Enteritidis-inoculated samples (1-5 CFU SE/analytical unit) were tested by the test method as well as the appropriate cultural reference method U.S. Food and Drug Administration-Bacteriological Analytical Manual (drag swabs and egg pools) or U.S. Department of Agriculture-Food Safety and Inspection Service (chicken carcass rinsates). A total of 80 samples were tested by both methods in the study. Fifty-two samples were positive by the RapidChek SELECT Salmonella Enteritidis method and 38 were found positive by the respective reference method. The sensitivity of the method was 100% and the specificity was 100%. The accuracy of the test method was 137%, indicating that the method was more sensitive than the reference method. The RapidChek SELECT Salmonella Enteritidis method was tested with 82 Salmonella Group D1 strains including 63 Salmonella Enteritidis strains as well as 32 non-Salmonella Group D1 strains representing 10 bacteria genera. The test method detected all 82 Group D1 strains (100% sensitivity). None of the non-Salmonella Group D1 or other genera of bacteria were detected, indicating a specificity of 100%. The method was shown to be highly robust and stable under control and accelerated stability conditions.  相似文献   

8.
Real-time PCR methods for detecting foodborne pathogens offer the advantages of simplicity and quick time-to-results compared to traditional culture methods. In this study, the MicroSEQ real-time PCR system was evaluated for detection of Salmonella spp. in 10 different food matrixes following the AOAC Research Institute's Performance Tested Method validation program. In addition, the performance of the MicroSEQ system was evaluated for the detection of Salmonella in peanut butter as a part of the Emergency Response Validation Program sponsored by the AOAC Research Institute. The system was compared to the ISO 6579 reference method using a paired-study design for detecting Salmonella spp. in raw ground beef, raw chicken, raw shrimp, Brie cheese, shell eggs, cantaloupe, chocolate, black pepper, dry infant formula, and dry pet food. For the peanut butter study, the system was compared to the U.S. Food and Drug Administration's Bacteriological Analytical Manual procedures using an unpaired-study design. No significant difference in performance was observed between the MicroSEQ Salmonella spp. detection system and the corresponding reference methods for all 11 food matrixes. The MicroSEQ system detected all Salmonella strains tested, while showing good discrimination against detection of an exclusivity panel of 30 strains, with high accuracy.  相似文献   

9.
Singlepath Salmonella is an immunochromatographic (lateral flow) assay for the presumptive qualitative detection of Salmonella spp. in food. The AOAC Performance-Tested Method study evaluated Singlepath Salmonella as an effective method for the detection of Salmonella spp. in the following selected foods: dried skimmed milk, black pepper, dried pet food, desiccated coconut, cooked peeled frozen prawns, raw ground beef, and raw ground turkey. When the foods were inoculated with Salmonella spp. at levels ranging from low [0.23-1.08 colony forming units (CFU)/25 g] to high (2.3-6.0 CFU/25 g), a Chi-square value of 0.9 indicated that there was no significant difference between Singlepath Salmonella and the ISO 6579:2002 reference method. Singlepath Salmonella gave a false-positive rate of 7.3% and a false-negative rate of 2.5%. For the inclusivity study, all 105 Salmonella serovars reacted with Singlepath Salmonella. For the exclusivity study, 58 non-Salmonella spp. were tested. There were no cross-reactions with Singlepath Salmonella from these strains.  相似文献   

10.
Reveal for Salmonella test system.   总被引:2,自引:0,他引:2  
The Reveal for Salmonella (RSS) test system is a presumptive qualitative test that detects the presence of Salmonella organisms in foods within 21 h total testing time, allowing the user to release negative products 24 h earlier than when using other rapid test kits. Foods are enriched with a proprietary resuscitation medium called Revive and then selectively enriched with either Selenite Cystine or Rappaport-Vassiliadis selective media. The enriched culture is used to inoculate the RSS detection device, which initiates a lateral flow through a reagent zone containing anti-Salmonella antibodies conjugated to colloidal gold particles that capture antigens present in the culture. The antigen-antibody complex migrates farther and is captured by an additional anti-Salmonella antibody, causing the colloidal gold to precipitate and form a visual line, indicating a positive result. A procedural control line also will form regardless of the presence of Salmonella organisms to indicate the test is working properly. Existing AOAC Official Methods for Salmonella organisms require a 48 h enrichment before testing. Hence, a food product has to be held before release, adding extra cost to the company and the consumer. The RSS test system was evaluated by quantitative spiking studies. Although AOAC encourages inclusion of naturally contaminated foods, almost all microbiological AOAC validation studies have been performed with artificially contaminated foods for absolute control over the study. The RSS test system is designed to test many food types for Salmonella organisms and has a limit of detection of 5-10 colony-forming units (cfu)/25 g with a false-negative rate of < 1% and a false-positive rate of < 5.0%. It showed an 81% overall agreement with the traditional procedure of the U.S. Department of Agriculture's Food Safety Inspection Service.  相似文献   

11.
A collaborative study was conducted to compare a new enrichment procedure for the TECRA Salmonella Visual Immunoassay with the reference method given in the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM 7th Ed.). Three food types (milk powder, black pepper, and soy flour) were analyzed in Australia, and 3 food types (milk chocolate, dried egg, and raw turkey) were analyzed in the United States. Thirty-eight collaborators participated in the study. No significant differences (p > 0.05) were observed for the pairwise comparison of the proportion of positive samples for the TECRA method with that for the reference method. The new enrichment procedure for the TECRA method has been adopted First Action by AOAC INTERNATIONAL.  相似文献   

12.
A Performance Tested Method validation study was conducted for a new lateral flow immunoassay (Reveal Listeria 2.0) for detection of Listeria spp. in foods and environmental samples. Results of inclusivity testing showed that the test detects all species of Listeria, with the exception of L. grayi. In exclusivity testing conducted under nonselective growth conditions, all non-listeriae tested produced negative Reveal assay results, except for three strains of Lactobacillus spp. However, these lactobacilli are inhibited by the selective Listeria Enrichment Single Step broth enrichment medium used with the Reveal method. Six foods were tested in parallel by the Reveal method and the U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) reference culture procedure. Considering data from both internal and independent laboratory trials, overall sensitivity of the Reveal method relative to that of the FDA/BAM procedure was 101%. Four foods were tested in parallel by the Reveal method and the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference culture procedure. Overall sensitivity of the Reveal method relative to that of the USDA-FSIS procedure was 98.2%. There were no statistically significant differences in the number of positives obtained by the Reveal and reference culture procedures in any food trials. In testing of swab or sponge samples from four types of environmental surfaces, sensitivity of Reveal relative to that of the USDA-FSIS reference culture procedure was 127%. For two surface types, differences in the number of positives obtained by the Reveal and reference methods were statistically significant, with more positives by the Reveal method in both cases. Specificity of the Reveal assay was 100%, as there were no unconfirmed positive results obtained in any phase of the testing. Results of ruggedness experiments showed that the Reveal assay is tolerant of modest deviations in test sample volume and device incubation time.  相似文献   

13.
The TECRA Salmonella Visual Immunoassay (VIA) using Rappaport-Vassiliadis RV[R10] as a single selective enrichment broth has Final Action approval (AOAC Method 998.09). TECRA has recently developed a protocol (TECRA ULTIMA), which involves the addition of a new additive to a 1 mL aliquot of the RV[R10] broth, prior to the heat-killing step, thereby allowing the RV[R10] broth to be tested directly in the kit and thus eliminating the need for the 2 h post-enrichment in M broth. An in-house validation study was conducted to compare the modified AOAC Method 998.09 to the reference culture method. Three foods were used in the study: Naturally contaminated raw ground poultry at high (10-50 cells/25 g), and low (1-5 cells/25 g) levels; and milk powder and peanut butter, artificially inoculated at low and high levels with Salmonella bovismorbificans and S. enterica Mbandaka, respectively. Twenty test portions were analyzed for each level with 10 uninoculated control samples per food. Overall, no significant differences (p <0.05) were observed when the proportion of positive test portions for the modified VIA were compared with that for the reference method. This minor modification, which employs the additive (provided in the TECRA ULTIMA SALMONELLA Test Kit) to permit the direct analysis of RV[R10] broth has demonstrated the utility of the TECRA ULTIMA SALMONELLA protocol. It is recommended that the minor modification to Method 998.09 be approved First Action as an additional option within the method.  相似文献   

14.
A collaborative study was conducted to compare a new enrichment procedure for the TECRA Salmonella Visual Immunoassay (TSVIA) with the reference method given in the U.S. Food and Drug Administration's Bacteriological Analytical Manual (7th Ed.). Three food types (milk powder, pepper, and soy flour) were analyzed in Australia and 3 food types (milk chocolate, dried egg, and raw turkey) were analyzed in the United States. Thirty-eight collaborators participated in the study. The TECRA method was evaluated using both Rappaport-Vassiliadis R10 (RV(R10)) and tetrathionate (TT) broths for selective enrichment. M broth cultures arising from each of the 2 selective enrichment broths were tested in the TSVIA using 2 individual wells, one for each selective broth, and a single well to test the pooled selective enrichment broths. The results for the pooled enrichment broths were reported elsewhere. This study presents the results for the use of single enrichment broths, i.e., RV(R10) only or TT only, with the TSVIA. No significant differences (p > 0.05) were observed for the pairwise comparison of the proportion of positive samples for either RV(R10) or TT used as a single enrichment broth for the TSVIA with that for the reference method.  相似文献   

15.
The TECRA Unique Salmonella test uses the principle of immunoenrichment to allow rapid detection of Salmonellae in food. A collaborative study was conducted to compare the TECRA Salmonella Unique test with the reference culture method given in the U.S. Food and Drug Administration's Bacteriological Analytical Manual. Three food types (milk powder, pepper, and soy flour) were analyzed in Australia and 2 food types (milk chocolate and dried egg) were analyzed in the United States. Forty-one collaborators participated in the study. For each of the 5 foods at each of the 3 levels, a comparison showed no significant differences (p > or = 0.05) in the proportion of positive test samples for Unique and that for the reference method using the Chi-square test for independence with continuity correction.  相似文献   

16.
Six foods representative of a wide variety of processed, dried powder processed, and raw food types were analyzed by the Visual Immunoprecipitate Assay (VIP) for Salmonella and AOAC INTERNATIONAL culture method. Paired samples of each food type were simultaneously analyzed; one sample by the VIP method and one by the AOAC culture method. A total of 24 laboratories representing federal government agencies and private industry, in the United States and Canada, participated in this collaborative study. Food types were inoculated with species of Salmonella with the exception of raw ground chicken, which was naturally contaminated. No statistical differences (p < 0.05) were observed between VIP for Salmonella interpretation and the AOAC culture method for any inoculation level of any food type or naturally contaminated food. The method was adopted Official First Action status by AOAC INTERNATIONAL.  相似文献   

17.
A multilaboratory study was conducted to compare the automated BAX System to the standard cultural methods for detection of Salmonella in selected foods. Five food types--frankfurters, raw ground beef, mozzarella cheese, raw frozen tilapia fish, and orange juice--at 3 inoculation levels, were analyzed by each method. A sixth food type, raw ground chicken, was tested using 3 naturally contaminated lots. A total of 16 laboratories representing government and industry participated. In this study, 1386 samples were analyzed, of which 1188 were paired samples and 198 were unpaired samples. Of the 1188 paired samples, 461 were positive by both methods and 404 were negative by both methods. Thirty-seven samples were positive by the BAX System but negative by the standard reference method, and 11 samples were positive by standard cultural method and negative by the BAX System. Of the 198 unpaired samples, 106 were positive by the BAX System and 60 were positive by the standard cultural method. A Chi square analysis of each of the 6 food types, at the 3 inoculation levels tested, was performed. For all foods, the BAX System demonstrated results comparable to those of the standard reference methods based on the Chi square results.  相似文献   

18.
The SDIX RapidChek Listeria F.A.S.T. test system was validated against the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) cultural reference method for the detection of Listeria species on stainless steel, plastic, rubber, and painted concrete. The SDIX method uses a proprietary RapidChek Listeria enrichment media for a one-step, 24-40 h enrichment at 30 degrees C, and detects Listeria on an immunochromatographic lateral flow device in 10 min. Different Listeria species were used to spike each of the environmental surfaces. Environmental surfaces were spiked at levels ranging from 50 to 400 CFU/surface (1 in.2 swabs for painted concrete, 4 in.(2) for sponge). A total of 120 spiked samples were tested by the SDIX method at 24 and 40 h and the cultural reference method. Total confirmed positives were 49, 54, and 48 for the SDIX 24 h method, the SDIX 40 h method, and the USDA-FSIS cultural reference method, respectively. Nonspiked samples from all environmental surfaces were reported as negative for Listeria spp. by all methods. The overall Chi square was 0.017 (P = 0.104) and 0.611 (P= 0.566) after a 24 and 40 h enrichment, respectively, indicating that the test method was equivalent in performance to the reference method at both enrichment times. The SDIX method was evaluated for the detection of 50 Listeria and 35 non-Listeria bacterial strains. All 50 Listeria strains were detected by the method (100% sensitivity). Five out of 35 non-Listeria species gave light test signals when grown in nonselective broth culture and tested undiluted. However, when grown in the RapidChek Listeria F.A.S.T. proprietary media, only one bacterial strain (Staphylococcus aureus) was detected, giving a very low test signal (97% specificity). The method was shown to be robust toward several alterations in testing and storage conditions.  相似文献   

19.
AOAC Official Method 996.10, Assurance Enzyme Immunoassay (EIA) for Escherichia coli O157:H7 (EHEC), was modified to incorporate a new enrichment protocol using BioControl EHEC8 medium for testing raw and cooked beef. Foods were tested by EIA and the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) enrichment conditions and the FDA Bacteriological Analytical Manual (BAM) isolation and confirmation techniques. A total of 14 collaborators participated. Raw and cooked ground beef were inoculated with E. coli O157:H7 at 2 different levels: a high level where predominantly positive results were expected, and a low level where fractional recovery was anticipated. Collaborators tested 378 test portions and controls by both the 8 h EIA and the USDA/FSIS enrichment methods, for a total of 756 test portions. Of the 378 paired test portions, 75 were positive and 212 were negative by both methods. Thirteen test portions were presumptively positive by EIA and could not be confirmed culturally; 30 were negative by EIA, but confirmed positive by culture; and 65 were negative by the culture method, but confirmed positive by the EIA method. There was no statistical difference between results obtained with the Assurance EIA for EHEC 8 h method and the culture method for raw ground beef. The Assurance EIA had a significantly higher recovery for cooked beef.  相似文献   

20.
In 2010, the BAX System PCR assay for Salmonella was modified to include a hot start functionality designed to keep the reaction enzyme inactive until PCR begins. To validate the assay's Official Methods of Analysis status to include this procedure modification, an evaluation was conducted on four food types that were simultaneously analyzed with the BAX System and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Identical performance between the BAX System method and the reference methods was observed. Additionally, lysates were analyzed using both the BAX System Classic and BAX System Q7 instruments with identical results using both platforms for all samples tested. Of the 100 samples analyzed, 34 samples were positive for both the BAX System and reference methods, and 66 samples were negative by both the BAX System and reference methods, demonstrating 100% correlation. No instrument platform variation was observed. Additional inclusivity and exclusivity testing using the modified test kit demonstrated the test kit to be 100% accurate in evaluation of test panels of 352 Salmonella strains and 46 non-Salmonella strains.  相似文献   