首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
SLIM is a large area experiment (440 m2) installed at the Chacaltaya cosmic ray laboratory since 2001, and about 100 m2 at Koksil, Himalaya, since 2003. It is devoted to the search for intermediate mass magnetic monopoles (107–1013 GeV/c2) and nuclearites in the cosmic radiation using stacks of CR-39 and Makrofol nuclear track detectors. In four years of operation it will reach a sensitivity to a flux of about 10-15 cm-2 s-1 sr-1. We present the results of the calibration of CR-39 and Makrofol and the analysis of a first sample of the exposed detector.  相似文献   

2.
Radon alpha activity concentration has been measured in 28 homes in the Erbil Capital-Iraqi Kurdistan region during the autumn season by using time-integrated passive radon dosimeters containing CR-39 solid state nuclear track detectors “SSNTDs”. The radon activity concentrations in these homes range from (10.33–90.34) with an average of . The average absorption effective dose equivalent for a person living in homes for which the investigation were done was found to be , obtained by using an equilibrium factor of 0.5 and an occupancy factor of 0.8. The average lung cancer cases per year per 106 person was found to be 23±12.  相似文献   

3.
Experimental results and theoretical studies show that protons from the hydrogen plasma focus are emitted predominantly in the axial direction. In this work the results of the flux and energy distribution measurements of the axial protons using CR-39 detector are presented. The main purpose of the experiment is to test the suitability of a plasma focus device as a source for (p,) nuclear reactions, especially and .  相似文献   

4.
Radon exhalation rate from fly ash samples and from the homogeneous mixture of fly ash of different proportions additive in soil and cement samples to study the effect of the addition was measured by cup dosimeter using SSNTDs. Radon activities were found to vary from (1018±38) to ( whereas the radon exhalation rate varied from (366±14) to . A gradual increase has been observed in samples having fly ash as an additive in cement samples whereas a gradual decrease was observed in soil samples after the addition of fly ash. 238U in fly ash was measured by a low-level NaI (Tl)-based gamma ray spectrometer. The results show enhancement in U concentration in fly ash as compared to coal samples, whereas radon exhalation rate is less in fly ash samples.  相似文献   

5.
Subsequent to the proposal of a two-layer structured radiator for more efficient detection of high-energy neutrons with a plastic nuclear track detector (PNTD), its availability has been investigated both experimentally and theoretically. An inner deuterized hydrocarbon (CD2) layer adjacent to PNTD should play the role of both a radiator of deuterons recoiled there and a degrader for energetic protons recoiled in the outer layer of a CH2 material. It was found that the energy dependence of the efficiency was changed sensitively by the thickness of the CD2 layer. A best combination of CH2 and CD2 thickness was estimated under a condition of a constant total thickness. For example, the sensitivity could be flattened within 20% between about 5 and 70 MeV by using -CD2 and -CH2.  相似文献   

6.
Recoiling daughters of -decaying U and Th impurities in mica and other minerals produce localised lattice damage: alpha-recoil tracks. The age of a sample can be calculated from the number of tracks per unit volume (NART). To this end, the mica is etched and the etch pits at the sites of recoil-tracks are counted under the optical microscope. Because the measured track densities increase with etching time, NART is calculated from the fitted regression line. A number of problems inherent in this approach are overcome by the etch–anneal–etch and the mirror-image methods. The track densities determined with these methods are independent of etching time. Although both methods need improvement, they hold the potential of a precise determination of NART from a single measurement in future recoil-track dating.  相似文献   

7.
A device to determine the detection efficiency of CR-39 for alpha particles is presented. A beehive collimator restricted the angle of incidence of alpha particles on a CR-39 sheet, such that the total number of alpha emitters could be determined. This makes it possible to obtain the critical angle of incidence, ΘC, and the maximum angle of incidence resulting in round (diameter ratio <1.100) etch pits, Θmax. In this work, these angles were determined for incidence energies around 7.5 MeV (more specifically 6.1 and 8.8 MeV).  相似文献   

8.
The behaviour of ubiquitous radon (), thoron () and their progeny in the indoor atmosphere generally reflect a complex interplay between a number of processes, the most important of which are radioactive -decay, ventilation, attachment to aerosols and deposition on the surfaces. The present work involved a long-term (1997–2000) passive monitoring of and in the indoor environment of the North-Eastern region of India. This region being a zone of high seismicity, the indoor radon and thoron measurement of the region will provide a better insight and a valuable database for any study related to radon and thoron anomalies.  相似文献   

9.
Measurement of the correct neutron fluence in various energy intervals in and around the neutron sources is important for the purpose of personnel and environmental neutron dosimetry. In the present paper we present a method for the measurement of neutron fluence using a CR-39 plastic track detector. The samples exposed to fission neutrons from a reactor with 1012 fluence and to fast neutrons from a 241Am–Be source with a fluence of were etched for 14 time intervals starting from 10 to 570 min in 6 N NaOH at . The etched samples were exposed to the monochromatic light signal from an iodine–tungsten lamp and the transmittance was measured after each etching time interval using a UV Spectrophotometer. An exponential decay of the transmittance has been observed with increasing etching time. The behaviour of the fission neutrons having four different values of fluence has been observed to be distinctly different from that of the fast neutrons. It has also been observed that there is a linear relationship between the transmittance decay constant and fission neutron fluence.  相似文献   

10.
Neutron dosimetry based on U and Th thin films was used for fission-track dating of the age standard Moldavite, the central European tektite, from the Middle Miocene deposit of Jankov (southern Bohemia, Czech Republic). Our fission-track age () agrees with a recent 40Ar/39Ar age, , based on several determinations on Moldavites from different sediments, including the Jankov deposit. This result indicates that the U and Th thin film neutron dosimetry represents a reliable alternative for an absolute approach in fission-track dating.  相似文献   

11.
The role of oxygen for stabilising radicals to form permanent damages in irradiated samples which are basically important for the etching process of track detectors has been studied. Samples of CR-39 were irradiated with 4 MeV -particles with a fluence of 30 000 particles per cm2. The irradiations were performed in three different regimes:
• variation of out-gassing time in vacuum before irradiation;

• no out-gassing time but varied post-irradiation storage times in vacuum;

• variation of both storage times in vacuum before and after irradiation.

Generally, the absence of dissolved oxygen in the irradiated sample results in a decreased detection sensitivity in comparison with the detection properties and track parameters of samples irradiated in air. To determine the sensitivity the depth dependence of the track etch rate vT(x) along the particle trajectory has been measured. From the observation of the dependence of the decreasing sensitivity on the post-irradiation storage time in vacuum, a lifetime of free radicals of 30 min could be derived. The amount of permanent damages responsible for the etching mechanism is related to the concentration profile of back-diffused oxygen and the REL-dependent radical concentration. This confirms previous results that the detection sensitivity is not a simple function of REL but depends on both REL and x the stronger the deeper within the irradiated sample.  相似文献   


12.
We consider the implications from the possibility that the recently observed state X(3872) is a meson–antimeson molecule. We write an effective Lagrangian consistent with the heavy-quark and chiral symmetries needed to describe X(3872). We explore the consequences of the assumption that X(3872) is a molecular bound state of D*0 and mesons for the existence of bound states in the and channels.  相似文献   

13.
In radiobiology, low doses of high-LET radiation correspond to a few particle traversals through the cell population. Therefore, for studies on cell monolayers irradiated with a low dose of -particles, it is extremely useful if the number and position of particle traversals can be determined. In this study we describe a new method, based on UV-curing, to obtain a thick CR-39 grafted onto a thick PolyEthylene Terephtalate (PET). This thin double polymeric layer, used as a dish base, has a regular and reproducible detector thickness which can be traversed by 3.5 MeV -particles, with a sufficient residual energy to traverse mammalian cells attached to the base. The recording properties of a PET-CR-39 dish, together with a demonstration of its use for radiobiological experiments, are presented. This new tool allows the precise determination of single-track impact parameters at a sub-cellular level.  相似文献   

14.
In previous investigations the formation of radicals induced by γ-irradiation in CR-39 samples has been studied by electron spin resonance (ESR) spectroscopy. On the other hand, all attempts fail to detect radicals in samples irradiated by particles (p, and neutrons). The present work succeeded in detection of radicals produced by charged particle radiation in CR-39 (TASTRAK). The detectors were irradiated with protons of 7 MeV and -particles of 3 MeV with fluences in the order of 1011–1012 particles/cm2. The observed ESR signal is composed of at least four different resonance lines for each of which we determined the amplitudes, g-factors, lifetimes and the G-value. The amplitude of the total ESR signal decreases rapidly with a short and a longer lifetime. About 5 days after irradiation the ESR intensity decreased to an undetectable value. The lowest detectable dose (LDD) is of the order of 1 kGy.  相似文献   

15.
Production of f0(1710), a theoretical endeavor of pure scalar glueball state, is studied in detail from exclusive rare B decay within the framework of perturbative QCD. The branching fraction for is estimated to be about 8×10−6, while for it is smaller by roughly an order of magnitude. With the accumulation of almost 1 billion pairs from the BaBar and Belle experiments to date, hunting for a scalar glueball via these rare decay modes should be attainable.  相似文献   

16.
For arbitrary interparticle interaction u(r12), the model two-electron atom in the title is shown to be such that the ground-state electron density ρ(r) is determined uniquely by the correlated kinetic energy density tR(r) of the relative motion. Explicit results for tR(r) are presented for the Hookean atom with force constant k=1/4, and also for . Possible relevance of the Hookean atom treatment to the ground state of the helium atom itself is briefly discussed.  相似文献   

17.
A system to expose biological specimens to medium-energy (2.6–6.0  MeV/u) irradiation has been developed at the NIRS-HIMAC. In order to determine the beam energy or LET at the irradiation position in air, the dose distribution for 6.0  MeV/u carbon beam has been obtained using a secondary electron monitor and a flat-type ionization chamber by using air as the energy absorber. Imaging plates were applied to assess the beam profile distribution. The intensity of photo-stimulated luminescence (PSL) was found to be almost proportional to the energy deposited within the sensitive layer of the imaging plate. It has been confirmed that a uniform irradiation field can be produced (about ±5% within 20 mm in diameter) at low-intensity exposure from 101 to . Long-term beam stability in the low-intensity condition has also been demonstrated. As a consequence, the methodology for uniform, stable and low-intensity beam exposure has been established, and the continuously variable linear energy transfer (LET) values have also been obtained by changing the distance from the endcap of beamport, for biological studies.  相似文献   

18.
We present the calibration of the Makrofol–DE nuclear track detector (NTD) using Pb-ions of 158 GeV/amu. Improvements in the post-etched surfaces, reduction in the surface background of the Makrofol–DE NTDs and high-contrast tracks were achieved with the appropriate addition of ethyl alcohol in KOH aqueous solutions. The calibration of Makrofol–DE has shown for the first time all the peaks arising due to nuclear fragments with Z52. The measurement of the cone heights shows well-separated individual peaks for Z/β=59–82 and 83 (charge pickup).  相似文献   

19.
The response of PN3 and CR-39 personal dosemeters with different configurations, developed by the IReS (Strasbourg), the IPNO (Orsay) and the UAB (Barcelona) groups, is investigated in this study. Both dosemeters were mounted on a water-filled phantom and were simultaneously exposed under different incidence angles (0, 30 and 60) to the following: (i) three ISO neutron sources (241Am-Be, bare 252Cf and moderated 252Cf with Cd shielding), and (ii) two realistic neutron sources (SIGMA and moderated 252Cf) at the IRSN (Cadarache) facilities. After irradiation, the plastic detectors were etched and evaluated according to local routine procedures and corrections for the effect of source-to-detector distance were taken into account. A comparison of the average background, the minimum detectable dose equivalent and the field calibration factor is performed as well.  相似文献   

20.
We show numerically that a Kerr nonlinear system composed of two channel waveguides coupled periodically by circular microresonators can be used as an all optical diode. The diode has low intensity requirements (50 MW/cm2) and compact dimensions (100  m).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号