首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The separation of the enantiomers of 17 chiral sulfoxides was studied on polysaccharide‐based chiral columns in polar organic mobile phases. Enantiomer elution order (EEO) was the primary objective in this study. Two of the six chiral columns, especially those based on amylose tris(3,5‐dimethylphenylcarbamate) and cellulose tris(4‐chloro‐3‐methylphenylcarbamate) (Lux Cellulose‐4) proved to be most successful in the separation of the enantiomers of the studied sulfoxides. Interesting examples of EEO reversal were observed depending on the chiral selector or the composition of the mobile phase. For instance, the R‐(+) enantiomer of lansoprazole eluted before the S‐(?) enantiomer on Lux Cellulose‐1 in both methanol or ethanol as the mobile phase, while the elution order was opposite in the same eluents on amylose tris(3,5‐dimethylphenylcarbamate) with the S‐(?) enantiomer eluting before the R‐(+) enantiomer. The R‐(+) enantiomer of omeprazole eluted first on Lux Amylose‐2 in methanol but it was second when acetonitrile was used as the mobile phase with the same chiral selector. Several other examples of reversal in EEO were observed in this study. An interesting example of the separation of four stereoisomers of phenaminophos sulfoxide containing chiral sulfur and phosphor atoms is also reported here.  相似文献   

2.
The separation of enantiomers of 10 chiral antimycotic drugs was studied on polysaccharide-based chiral columns with polar organic mobile phases. The emphasis was placed on some interesting examples of enantiomer elution order reversal observed depending on the chemistry of the chiral selector, separation temperature, major component, as well as the minor additive in the mobile phase. In particular, it was found that the elution order of enantiomers of chiral drug terconazole was opposite on cellulose- and amylose-based columns with the same pendant group. The affinity pattern of enantiomers of another chiral drug bifonazole was opposite towards to two amylose-based chiral selectors with different pendant groups. The affinity pattern of terconazole enantiomers also changed on some columns when the alcohol-based mobile phase was replaced with acetonitrile. An interesting effect of the minor acidic (formic acid) additives to the mobile phase on the affinity pattern of terconazole enantiomers was observed on Cellulose-2 and Cellulose-4 columns. In addition, a reversal of elution order of bifonazole enantiomers was observed on Amylose-2 column by variation of a separation temperature.  相似文献   

3.

The separation of enantiomers of 10 chiral antimycotic drugs was studied on polysaccharide-based chiral columns with polar organic mobile phases. The emphasis was placed on some interesting examples of enantiomer elution order reversal observed depending on the chemistry of the chiral selector, separation temperature, major component, as well as the minor additive in the mobile phase. In particular, it was found that the elution order of enantiomers of chiral drug terconazole was opposite on cellulose- and amylose-based columns with the same pendant group. The affinity pattern of enantiomers of another chiral drug bifonazole was opposite towards to two amylose-based chiral selectors with different pendant groups. The affinity pattern of terconazole enantiomers also changed on some columns when the alcohol-based mobile phase was replaced with acetonitrile. An interesting effect of the minor acidic (formic acid) additives to the mobile phase on the affinity pattern of terconazole enantiomers was observed on Cellulose-2 and Cellulose-4 columns. In addition, a reversal of elution order of bifonazole enantiomers was observed on Amylose-2 column by variation of a separation temperature.

  相似文献   

4.
In this paper the elution order reversal of enantiomers of fluorenylmethoxycarbonyl- or FMOC-isoleucine is described depending on the separation temperature and composition of the mobile phase when using the polysaccharide-based chiral column Lux Cellulose-1 in HPLC with normal-phase eluent. Reversal of the enantiomer elution order (EEO) in HPLC depending on the column temperature and content of the polar modifier in the mobile phase has been reported before in the literature. However, EEO reversal by changing the content of acidic modifier in the mobile phase seems to be described for the first time in the present work.  相似文献   

5.
The separation of the stereoisomers of 23 chiral basic agrochemicals was studied on six different polysaccharide‐based chiral columns in high‐performance liquid chromatography with various polar organic mobile phases. Along with the successful separation of analyte stereoisomers, emphasis was placed on the effect of the chiral selector and mobile phase composition on the elution order of stereoisomers. The interesting phenomenon of reversal of enantiomer/stereoisomer elution order function of the polysaccharide backbone (cellulose or amylose), type of derivative (carbamate or benzoate), nature, and position of the substituent(s) in the phenylcarbamate moiety (methyl or chloro) and the nature of the mobile phase was observed. For several of the analytes containing two chiral centers all four stereoisomers were resolved with at least one chiral selector/mobile phase combination.  相似文献   

6.
The HPLC enantioseparation of nine atropisomeric 3,3′,5,5′‐tetrasubstituted‐4,4′‐bipyridines was performed in normal and polar organic (PO) phase modes using two immobilized polysaccharide‐based chiral columns, namely, Chiralpak IA and Chiralpak IC. The separation of all racemic analytes, the effect of the chiral selector, and mobile phase (MP) composition on enantioseparation and the enantiomer elution order (EEO) were studied. The beneficial effect of nonstandard solvents, such as tetrahydrofuran (THF), dichloromethane (DCM), and methyl t‐butyl ether on enantioseparation was investigated. All selected 4,4′‐bipyridines were successfully enantioseparated on Chiralpak IA under normal or PO MPs with separation factors from 1.14 to 1.70 and resolutions from 1.3 to 6.5. Two bipyridines were enantioseparated at the multimilligram level on Chiralpak IA. Differently, Chiralpak IC was less versatile toward the considered class of compounds and only five bipyridines out of nine could be efficiently separated. In particular, on these columns, the ternary mixture n‐heptane/THF/DCM (90:5:5) as MP had a positive effect on enantioseparation. An interesting phenomenon of reversal of the EEO depending on the composition of the MP for the 3,3′‐dibromo‐5,5′‐bis‐(E)‐phenylethenyl‐4,4′‐bipyridine along with an exceptional enantioseparation for the 3,3′‐dibromo‐5,5′‐bis‐ferrocenylethynyl‐4,4′‐bipyridine (α = 8.33, Rs = 30.6) were observed on Chiralpak IC.  相似文献   

7.
A comprehensive study into the effects of mobile phase composition and column temperature on enantiomer elution order was conducted with a set of chiral rod-like liquid crystalline materials. The analytes were structurally similar and comprised variances such as length of terminal alkyl chain, presence of chlorine, number of phenyl rings, and type of chiral center. Experiments were carried out in polar organic and reversed-phase modes using amylose tris(3-chloro-5-methylphenylcarbamate) immobilized on silica gel as the chiral stationary phase. For all liquid crystals, reversal of elution order of enantiomers was observed based on type of used cosolvent and/or its content in the mobile phase; for some of the liquid crystals a temperature-induced reversal was also observed. Both linear and nonlinear dependencies of natural logarithm of enantioselectivity on temperature were found. Tested mobile phases comprised pure organic solvents and binary and tertiary mixtures of acetonitrile with organic solvents and/or water. Effect of acidic/basic mobile phase additives was also tested. Effect of structure of chiral selector is briefly discussed.  相似文献   

8.
In this work, a novel polysaccharide‐based chiral stationary phase, cellulose tris(4‐chloro‐3‐methylphenylcarbamate), also called Sepapak 4 has been evaluated for the chiral separation of amlodipine (AML) and its two impurities. AML is a powerful vasodilatator drug used for the treatment of hypertension. Capillary columns of 100 μm id packed with the chiral stationary phase were used for both nano‐LC and CEC experiments. The optimization of the mobile phase composed of ACN/water, (90:10, v/v) containing 15 mM ammonium borate pH 10.0 in nano‐LC allowed the chiral separation of AML and the two impurities, but not in a single run. With the purpose to obtain the separation of the three pairs of enantiomers simultaneously, CEC analyses were performed in the same conditions achieving better enantioresolution and higher separation efficiencies for each compound. To fully resolve the mixture of six enantiomers, parameters such as buffer pH and concentration sample injection have been then investigated. A mixture of ACN/water (90:10, v/v) containing 5 mM ammonium borate buffer pH 9.0 enabled the complete separation of the three couples of enantiomers in less than 30 min. The optimized CEC method was therefore validated and applied to the analysis of pharmaceutical formulation declared to contain only AML racemate.  相似文献   

9.
Xiang C  Liu G  Kang S  Guo X  Yao B  Weng W  Zeng Q 《Journal of chromatography. A》2011,1218(48):8718-8721
Enantioseparation of naproxen was performed on an immobilized polysaccharide-based chiral stationary phase (CSP), Chiralpak IA, in the normal-phase mode. The effects of polar alcohol modifier in mobile phase and column temperature on retention, enantioseparation, and elution order were investigated. Two unusual phenomena were observed. One was solvent-induced reversal of elution order for the two enantiomers. Not only the type but also the content of polar alcohol modifier could induce the reversal. Another uncommon phenomenon was peak deformation under some chromatographic conditions.  相似文献   

10.
The retention behavior of a set of polar peptides separated on a silica hydride stationary phase was examined with a capillary HPLC system coupled to ESI‐MS detection. The mobile phases consisted of formic acid or acetic acid/acetonitrile/water mixtures with the acetonitrile content ranging from 5 to 80% v/v. The effects on peptide retention of these two acidic buffer additives and their concentrations in the mobile phase were systematically investigated. Strong retention of the peptides on the silica hydride phase was observed with relatively high‐organic low‐aqueous mobile phases (i.e. under aqueous normal‐phase conditions). However, when low concentrations of acetic acid were employed as the buffer additive, strong retention of the peptides was also observed even when high aqueous content mobile phases were employed. This unique feature of the stationary phase therefore provides an opportunity for chromatographic analysis of polar peptides with water‐rich eluents, a feature usually not feasible with traditional RP sorbents, and thus under conditions more compatible with analytical green chemistry criteria. In addition, both isocratic and gradient elution procedures can be employed to optimize peptide separations with excellent reproducibility and resolution under these high aqueous mobile phase conditions with this silica hydride stationary phase.  相似文献   

11.
RP high‐performance liquid chromatographic methods were developed for the enantioseparation of eleven unusual β2‐homoamino acids. The underivatized analytes were separated on a chiral stationary phase containing (+)‐(18‐crown‐6)‐2,3,11,12‐tetracarboxylic acid as chiral selector. The effects of organic (alcoholic) and acidic modifiers, the mobile phase composition and temperature on the separation were investigated. The structures of the substituents in the α‐position of the analytes substantially influenced the retention and resolution. The elution sequence was determined in some cases: the S enantiomers eluted before the R enantiomers.  相似文献   

12.
An LC method was developed and prevalidated for the enantiomeric purity determination of S‐amlodipine in polar organic solvent chromatography using a chlorine‐containing cellulose‐based chiral stationary phase (CSP). The concentration of formic acid (FA) (0.01–0.2%) in the mobile phase containing acetonitrile as the main solvent was found to influence the elution order of amlodipine enantiomers as well as the enantioresolution. A reversal of the enantiomer elution order of amlodipine was only observed with chiral stationary phases with both electron‐withdrawing (chloro) and electron‐donating groups (methyl) on the phenyl moieties of the chiral selector, namely cellulose tris(3‐chloro‐4‐methylphenylcarbamate) and cellulose tris(4‐chloro‐3‐methylphenylcarbamate). The highest enantioresolution (Rs: 4.1) value was obtained at the lowest FA concentration (0.01%) using cellulose tris(4‐chloro‐3‐methylphenylcarbamate) as the chiral selector and the enantiomeric impurity, R‐amlodipine, eluted first under these conditions. Therefore, the mobile phase selected for the prevalidation of the method consisted of ACN/0.1% DEA/0.01% FA and the temperature was set at 25°C. The method was prevalidated by means of the strategy based on the total measurement error and the accuracy profile. The method was found to be selective and the limit of quantification was found to be about 0.05% for R‐amlodipine, while the limit of detection was close to 0.02%.  相似文献   

13.
N‐(2,4‐dinitrophenyl)‐proline and N‐(2,4‐dinitrophenyl)‐serine were enantiomerically resolved on the BSA chiral stationary phase by HPLC in reversed‐phase mode. Effects of chromatographic conditions on enantioseparation and elution order have been investigated in detail. For these two samples, reversal of enantiomer elution order was observed by changing buffer pH, the content of acetonitrile, or alcohol modifiers in mobile phase, which is firstly reported in the BSA chiral stationary phase studies. More interestingly, combined effect between buffer pH and the content of acetonitrile was also observed. In addition, coelution range of enantiomers varied along with the content of acetonitrile in mobile phase.  相似文献   

14.
以不同配比的甲醇和水作洗脱液,对手性物质酒石酸和5-氰基-1,3-二苯基-4,5-二氢吡唑进行了手性色谱柱高效液相色谱分离。对于亲水性的酒石酸,以纯水作为洗脱液,手性异构体不能得到分离;洗脱液中甲醇的含量增加到50%,D-和L-异构体得到分离,但是内消旋异构体和D-异构体仍然混在一个峰中;以100%甲醇作洗脱液,酒石酸的内消旋及D-和L-三个异构体的色谱峰全部分开。对于憎水性的5-氰基-1,3-二苯基-4,5-二氢吡唑,以100%甲醇作为洗脱液;当洗脱液中水的含量增加到30%时,R-和S-手性异构体的色谱峰开始分离,但是两个峰大小不相等,分离效果不理想;当洗脱液中水的含量增加到35%时,R-和S-手性异构体的色谱峰分离为两个大致相等的色谱峰,但是两个色谱峰仍有部分交叠。保留时间加长,有利于对映异构体的分离,保留时间长的色谱峰变宽。  相似文献   

15.
The applications of polysaccharide phenyl carbamate derivatives as chiral stationary phases (CSPs) for capillary electrochromatography (CEC) are often hindered by longer retention times, especially using a normal-phase (NP) eluent due to very low electroosmotic flow (EOF). Therefore, in this study, we propose an approach for the aforementioned problems by introducing two new types of negatively charged sulfate and sulfonated groups for polysaccharide CSPs. These CSPs were utilized to pack CEC columns for enantioseparation with a NP eluent. Compared to conventional cellulose tris(3,5-dimethylphenyl carbamate) or CDMPC CSPs, the sulfated CDMPC CSP (sulfur content 4.25%, w/w) shortened the analysis time up to 50% but with a significant loss of enantiomeric resolution (∼60%). On the other hand, the sulfonated CDMPC CSP (sulfur content 1.76%, w/w) not only provided fast throughput but also maintained excellent resolving power. In addition, its synthesis is much more straightforward than the sulfated one. Furthermore, we studied several stationary phase parameters (CSP loading and silica gel pore size) and mobile phase parameters (including type of mobile phase and its composition) to evaluate the throughput and enantioselectivity. Using the optimized conditions, a chiral pool containing 66 analytes was screened to evaluate the enantioselectivity under three different mobile phase modes (i.e., NP, polar organic phase (POP) and reversed-phase (RP) eluents). Among these mobile phase modes, the RP mode showed the highest success rate, whereas some degree of complementary enantioselectivity was observed with NP and POP. Finally, the feasibility of applying this CSP for CEC–MS enantioseparation using internal tapered column was evaluated with NP, POP and RP eluents. In particular, the NP-CEC–MS provided significantly enhanced sensitivity when methanol was replaced with isopropanol in the sheath liquid. Using aminoglutethimide as model chiral analyte, all three modes of CEC–MS demonstrated excellent durability as well as excellent reproducibility of retention time and enantioselectivity.  相似文献   

16.
The selectivity tuning of two columns coupled in series is investigated in chiral high-performance liquid chromatography. Two columns with reversal enantioselectivities [(R,R) Whelk-O 1 and (S,S) Whelk-O 1] are coupled in series via a T connector. Selectivity of such a column series is tuned by varying the mobile phase flows in the individual columns. The flow ratio necessary for the required selectivity is calculated on the basis of retention factors measured on the individual columns. The performance of this method for adjusting the required selectivity is studied by the separation of enantiomers of alkoxy substituted esters of phenylcarbamic acid. It is demonstrated that the change of the mobile phase flows in the individual columns enables change in the elution order of enantiomers.  相似文献   

17.
(S)‐N‐(3,5‐dinitrobenzoyl)leucine‐N‐phenyl‐N‐propylamine‐bonded silica was used as a chiral stationary phase for separation of a set of racemic π‐acidic and π‐basic α‐amino acid amides in electrolyteless ACN‐water eluents by CEC in the RP and polar organic (PO) modes. The effect of the amount of water in the ACN‐water eluent on chiral separation was examined. As water is added to ACN, retention was shortened but resolution and selectivity deteriorated severely. Retention, enantioselectivity, and resolution factors obtained in 100% ACN were compared with those in an n‐hexane‐isopropanol eluent with a small amount of water by normal phase (NP) CEC. Much shorter retention times with comparable enantioselectivities were observed with 100% ACN, demonstrating the advantage of separation on (S)‐N‐(DNB)leucine‐N‐phenyl‐N‐propylamine‐bonded silica in PO‐CEC over NP‐CEC.  相似文献   

18.
An investigation on the high‐performance liquid chromatography enantioseparation of 12 polyhalogenated 4,4′‐bipyridines on polysaccharide‐based chiral stationary phases is described. The overall study was directed toward the generation of efficient separations in order to obtain pure atropisomers that will serve as ligands for building homochiral metal organic frameworks. Four coated columns—namely, Lux Cellulose‐1, Lux Cellulose‐2, Lux Cellulose‐4, and Lux Amylose‐2—and two immobilized columns—namely, Chiralpak IC and IA—were used under normal, polar organic, and reversed‐phase elution modes. Moreover, Chiralcel OJ was considered under normal‐phase and polar organic conditions. The effect of the chiral selector and mobile phase composition on the enantioseparation, the enantiomer elution order and the beneficial effect of nonstandard solvents were studied. The effect of water in the mobile phase on the enantioselectivity and retention was investigated and retention profiles typical of hydrophilic interaction liquid chromatography were observed. Interesting phenomena of solvent‐induced enantiomer elution order reversal occurred under normal‐phase mode. All the considered 4,4′‐bipyridines were enantioseparated at the multimilligram level.  相似文献   

19.
M. Yarim  S. Sarac 《Chromatographia》2002,56(5-6):307-312
Summary Analytical HPLC methods using derivatized cellulose chiral stationary phases have been developed for separation of the enantiomers of 25 racemic 4-aryl-7,7-dimethyl- or 1,77-trimethyl-1,2,3,4,5,6,7,8-octahydroquinazoline-2,5-diones, condensed derivatives of dihydropyrimidines. The enantiomers of the compounds were resolved by normal-phase chromatography on silica-based cellulose tris(3,5-dimethylphenylcarbamate) (Chiralcel OD) and amylose tris(3,5-dimethylphenylcarbamate) (Chiralpak AD) columns with mobile phases consisting of mixtures ofn-hexane and an alcohol (2-propanol, ethanol, or methanol) in different proportions. The mobile phase and the chiral stationary phase were varied to achieve the best resolution. The effect of the concentration of alcohol in the mobile phase was studied. The resolution obtained on the two columns was complementary.  相似文献   

20.
The direct high-performance liquid chromatographic separation of three pairs of structurally related enantiomers on derivatized cellulose and amylose chiral stationary phases (Chiralcel OD, Chiralpak AD and Chiralpak AS) was studied using hexane as the mobile phase with 2-propanol or ethanol as modifiers. The separation, retention and elution order of the enantiomers on the different columns using different alcohol modifiers were compared. The effect of structural variation of the solutes on their k' was noted. A reversal of elution order of one enantiomeric pair upon changing the mobile-phase modifier was observed. Chiralcel OD and Chiralpak AD columns provided different elution orders of the enantiomers, including a fourth pair of enantiomers that were not structurally related to the other three pairs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号