首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 759 毫秒
1.
A novel 1,3‐alternate 25,27‐bis‐[cyanopropyloxy]‐26,28‐bis‐[3‐propyloxy]‐calix[4]arene‐bonded silica gel stationary phase (CalixPrCN) was prepared and its structure was confirmed by ATR‐FTIR spectroscopy and elemental analysis. The CalixPrCN phase was characterized in terms of its surface coverage, hydrophobic selectivity, aromatic selectivity, shape selectivity, hydrogen bonding capacity, residue metal content, and silanol activity based on Tanaka, Lindner, and SMR 870 test protocols. The effect of the acetonitrile content on the retention and selectivity of the selected neutral, basic, and acidic solutes was studied. The neutral and acidic analytes exhibited classical RP behavior, in which retention time decreases with increasing acetonitrile content. In contrast, basic analytes showed an increase in retention at low and high percentages of acetonitrile, forming “U‐shaped” retention profiles. The new calixarene phase was compared with previously reported 1,3‐alternate 25,27‐bis‐[propyloxy]‐26,28‐bis‐[3‐propyloxy]‐calix[4]arene stationary phase and commercial cyanopropyl column. The results indicate that the CalixPrCN stationary phase behaves like RP packing; however, inclusion complex formation, dipole–dipole, and π–π interactions seem to be involved in the separation process. The selectivity of this phase was demonstrated in separation of polynuclear aromatic hydrocarbons, non‐steroidal anti‐inflammatory drugs, and sulfonamides as analytes.  相似文献   

2.
Enantioseparation of limonene‐based bicyclic 1,3‐aminoalcohols and 1,3,5‐ and 1,3,6‐aminodiols was performed by normal‐phase high‐performance liquid chromatographic and supercritical fluid chromatographic (SFC) methods on polysaccharide‐based chiral stationary phases. The effects of the composition of the mobile phase, the column temperature and the structures of the analytes and chiral selectors on retention and selectivity were investigated by normal‐phase LC and SFC technique. Thermodynamic parameters derived from selectivity–temperature‐dependence studies were found to be dependent on the chromatographic method applied, the nature of the chiral selector and the structural details of the analytes. Enantiorecognition in most cases was enthalpically driven but an unusual temperature behavior was also observed: decreased retention times were accompanied by improved separation factors with increasing temperature, i.e. some entropically driven separations were also observed. The elution sequence was determined in all cases. The separation of the stereoisomers was optimized in both chromatographic modalities.  相似文献   

3.
Hydrophilic interaction liquid chromatography is a separation technique suitable for the separation of moderately and highly polar compounds. Various stationary phases (SPs) for hydrophilic interaction liquid chromatography are commercially available. While the SPs based on the same type of ligand are available from different providers, they can display a distinct retention characteristics and separation selectivity. The current work is focused on characterization and comparison of the separation systems of two amide‐based HPLC columns from two producers, i.e. XBridge Amide column and TSK gel Amide‐80 column. Several characterization procedures (tests) were used to investigate the differences between these columns. The chromatographic behavior of selected analytes indicates that multimodal interactions are responsible for retention and separation on these columns. Multiple testing approaches were used in order to reveal subtle differences between the SPs. Both amide‐based columns showed certain differences in retention, selectivity, and plate counts. Based on the tests used in this study, we conclude that the investigated columns provide a different degree of H‐bonding interactions.  相似文献   

4.
A series of polycyclic aromatic hydrocarbons (PAHs) of different size and shape has been used to characterize the chromatographic behavior of five calix[4]arene stationary phases in 1,3‐alternate conformation synthesized in our laboratory. The selection of linear, four‐ring nonlinear, and five‐ring PAHs gave data on selectivity changes across range of the calix[4]arene columns. Retention of the 12 aromatic solutes has been evaluated at various methanol contents in the mobile phase (70–100% v/v) and column temperatures (20–45°C). The thermodynamic parameters underlying the retention mechanisms revealed that each of the five calix[4]arene columns exhibited variation in selectivity and retention of PAHs caused by enthalpy and entropy effects. The calixarene stationary phases substituted with electron‐withdrawing groups exhibit enhanced selectivity toward PAHs in comparison to the rest of the investigated columns. The observed divergences are due to differences in solute–stationary phase interactions and originate in π–π and π‐electron transfer specific to the analytes and the type of calix[4]arene functionalization at the upper rim, as well as steric and sorption phenomena.  相似文献   

5.
6.
There are various reversed‐phase stationary phases that offer significant differences in selectivity and retention. To investigate different reversed‐phase stationary phases (aqueous stable C18, biphenyl, pentafluorophenyl propyl, and polar‐embedded alkyl) in an automated fashion, commercial software and associated hardware for mobile phase and column selection were used in conjunction with liquid chromatography and a triple quadrupole mass spectrometer detector. A model analyte mixture was prepared using a combination of standards from varying classes of analytes (including drugs, drugs of abuse, amino acids, nicotine, and nicotine‐like compounds). Chromatographic results revealed diverse variations in selectivity and peak shape. Differences in the elution order of analytes on the polar‐embedded alkyl phase for several analytes showed distinct selectivity differences compared to the aqueous C18 phase. The electron‐rich pentafluorophenyl propyl phase showed unique selectivity toward protonated amines. The biphenyl phase provided further changes in selectivity relative to C18 with a methanolic phase, but it behaved very similarly to a C18 when an acetonitrile‐based mobile phase was evaluated. This study shows the value of rapid column screening as an alternative to excessive mobile phase variation to obtain suitable chromatographic settings for analyte separation.  相似文献   

7.
The understanding of the retention behavior of large molecules is an area of interest in liquid chromatography. Resorcinarene‐based cavitands are cavity‐shaped cyclic oligomers that can create host–guest interactions. We have investigated the chromatographic behavior of two types of cyclic tetramers as analytes in high‐performance liquid chromatography. The experiments were performed at four different temperatures (15, 25, 35, 45°C) on two types of reversed stationary phases (C8 and C18) from two different manufacturers. We have found a huge difference between the retention of resorcinarenes and cavitands. In some cases, the retention factor of cavitands was even a hundred times larger than the retention factor of resorcinarenes. The retention of methylated derivates was two to four times larger compared to that of demethylated compounds on every column. The opposite retention behavior of the resorcinarenes and cavitands on the two types of stationary phases showed well the difference of the selectivity of the XTerra and BDS Hypersil columns. The retention mechanism was studied by the thermodynamic parameters calculated from the van't Hoff equation.  相似文献   

8.
A novel imidazolium‐embedded iodoacetamide‐functionalized silica‐based stationary phase has been prepared by surface radical chain‐transfer polymerization. The stationary phase was characterized by Fourier transform infrared spectrometry, thermogravimetric analysis, and element analysis. Fast and efficient separations of polar analytes, such as nucleosides and nucleic acid bases, water‐soluble vitamins and saponins, were well achieved in hydrophilic interaction chromatography mode. Additionally, a mixed mode of hydrophilic interaction and reversed‐phase could be also obtained in the analysis of polar and nonpolar compounds, including weak acidic phenols, basic anilines and positional isomers, with high resolution and molecular‐planarity selectivity, outperforming the commercially available amino column. Moreover, simultaneous separation of polar and nonpolar compounds was also achieved. In conclusion, the multimodal retention capabilities of the imidazolium‐embedded iodoacetamide‐functionalized silica‐based column could offer a wide range of retention behavior and flexible selectivity toward hydrophilic and hydrophobic compounds.  相似文献   

9.
Ion exchange chromatography, an alternative to reversed‐phase (RP) chromatography, is described in this paper. We aimed to obtain optimal conditions for the separation of basic drugs because silica‐based RP stationary phases show silanol effect and make the analysis of basic analytes hardly possible. The retention, separation selectivity, symmetry of peaks and system efficiency were examined in different eluent systems containing different types of buffers at acidic pH and with the addition of organic modifiers: methanol and acetonitrile. The obtained results reveal a large influence of the salt cation used for buffer preparation and the type of organic modifier on the retention behavior of the analytes. These results were also compared with those obtained on an XBridge C18 column. The obtained results demonstrated that SCX stationary phases can be successfully used as alternatives to C18 stationary phases in the separation of basic compounds. The most selective and efficient chromatographic systems were applied for the quantification of some psychotropic drugs in fortified human serum samples. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
First‐ and second‐dimension retention times for a series of alkyl phosphates were predicted for multiple column combinations in GC×GC. This was accomplished through the use of a three‐parameter thermodynamic model where the analytes’ interactions with the stationary phases in both dimensions are known. Ionic liquid columns were employed to impart unique selectivity for alkyl phosphates, and it was determined that for alkyl phosphate compounds, ionic liquid columns are best used in the primary dimension. Retention coordinates for unknown phosphates are predicted from the thermodynamic parameters of a set standard alkyl phosphates. Additionally, we present changing retention properties of alkyl phosphates on some ionic liquid columns, due to suspected reaction between the analyte and column. This makes it difficult to accurately predict their retention properties, and in general poses a problem for ionic liquid columns with these types of analytes.  相似文献   

11.
Two new kinds of alanine‐substituted calix[4]arene stationary phases of 5,11,17,23‐p‐tert‐butyl‐25,27‐bis(l ‐alanine‐methylester‐N‐carbonyl‐methoxy)‐26,28‐dihyroxycalix[4]arene‐bonded silica gel stationary phase (BABS4) and 5, 11, 17, 23‐p‐tert‐butyl‐25,26,27,28‐tetra(l ‐alanine‐methylester‐N‐carbonyl‐methoxy)‐calix[4]arene‐bonded silica gel stationary phase (TABS4) were prepared and characterized in the present study. They were compared with each other and investigated in terms of their chromatographic performance by using polycyclic aromatic hydrocarbons, disubstituted benzene isomers, and mono‐substituted benzenes as solute probes. The results indicated that both BABS4 and TABS4 exhibited multiple interactions with analytes. In addition, the commonly used Tanaka characterization protocol for the evaluation of commercially available stationary phases was applied to evaluate the properties of these two new functionalized calixarene stationary phases. The Tanaka test results were compared with Zorbax Eclipse XDB C18 and Kromasil phenyl columns, respectively. BABS4 has stronger hydrogen‐bonding capacity and ion‐exchange capacity than TABS4, and features weaker hydrophobicity and hydrophobic selectivity. Both of them behave similarly in stereoselectivity. Both BABS4 and TABS4 are weaker than C18 and phenyl stationary phases in hydrophobicity and hydrophobic selectivity.  相似文献   

12.
Mixed‐mode chromatographic stationary phases require functionalization with at least two functional groups to yield multiple interactions with analytes. Departing from reported methods, a mixture of two different monomers, glycidyl methacrylate and 2‐dimethylaminoethylmethacrylate, was grafted onto the surface of silica by a one‐step surface‐initiated atom transfer radical polymerization to prepare a novel hydrophilic interaction/anion‐exchange mixed‐mode chromatographic stationary phase. The grafted amounts of functional groups were controlled via varying the ratio of monomers in the polymerization system. The influences of water content, salt concentration and pH in the mobile phase were investigated to illustrate the mixed interaction between the stationary phase and analytes. The retention of various solutes on three columns, especially acidic and basic solutes, showed an obvious dependence on the ratio of the two monomers in the polymerization system. The results indicated that the strategy proposed in this work was beneficial to develop various types of mixed‐mode chromatographic stationary phases with adjustable selectivity to meet the needs of complex samples. Finally, the column was successfully employed in the isolation of melamine in liquid milk.  相似文献   

13.
14.
Unbonded silicon oxynitride and silica high‐performance liquid chromatography stationary phases have been evaluated and compared for the separation of basic compounds of differing molecular weight, pKa, and log D using aqueous/organic mobile phases. The influences of percentage of organic modifier, buffer pH, and concentration in the mobile phase on base retention were investigated on unbonded silicon oxynitride and silica phases. The results confirmed that unbonded silicon oxynitride and silica phases demonstrated excellent separation performance for model basic compounds and both the unbonded phases examined possessed a hydrophobic/adsorption and ion‐exchange character. The silicon oxynitride stationary phase exhibited high hydrophilicity compared with silica with a reversed‐phase mobile phase. An ion‐exclusion‐type mechanism becomes predominant for the separation of three aimed bases on the silicon oxynitride column at pH 2.8. Different from silicon oxynitride stationary phase, no obvious change for the retention time of three model bases on silica stationary phase at pH 2.8 can be observed.  相似文献   

15.
A dicationic imidazolium ionic liquid modified silica stationary phase was prepared and evaluated by reversed‐phase/anion‐exchange mixed‐mode chromatography. Model compounds (polycyclic aromatic hydrocarbons and anilines) were separated well on the column by reversed‐phase chromatography; inorganic anions (bromate, bromide, nitrate, iodide, and thiocyanate), and organic anions (p‐aminobenzoic acid, p‐anilinesulfonic acid, sodium benzoate, pathalic acid, and salicylic acid) were also separated individually by anion‐exchange chromatography. Based on the multiple sites of the stationary phase, the column could separate 14 solutes containing the above series of analytes in one run. The dicationic imidazolium ionic liquid modified silica can interact with hydrophobic analytes by the hydrophobic C6 chain; it can enhance selectivity to aromatic compounds by imidazolium groups; and it also provided anion‐exchange and electrostatic interactions with ionic solutes. Compared with a monocationic ionic liquid functionalized stationary phase, the new stationary phase represented enhanced selectivity owing to more interaction sites.  相似文献   

16.
Protein retention is very sensitive to the change of solvent composition in reversed‐phase liquid chromatography for so called “on–off” mechanism, leading to difficulty in mobile phase optimization. In this study, a novel 3‐chloropropyl trichlorosilane ligand bonded column was prepared for protein separation. The differences in retention characteristics between the 3‐chloropropyl trichlorosilane ligand bonded column and n‐alkyl chain modified (C2, C4, C8) stationary phases were elucidated by the retention equation . Retention parameters (a and c) of nine standard proteins with different molecular weights were calculated by using homemade software. Results showed that retention times of nine proteins were similar on four columns, but the 3‐chloropropyl trichlorosilane ligand bonded column obtained the lowest retention parameter values of larger proteins. It meant that their retention behavior affected by acetonitrile concentration would be different due to lower |c| values. More specifically, protein elution windows were broader, and retentions were less sensitive to the change of acetonitrile concentration on the 3‐chloropropyl trichlorosilane ligand bonded column than that on other columns. Meanwhile, the 3‐chloropropyl trichlorosilane ligand bonded column displayed distinctive selectivity for some proteins. Our results indicated that stationary phase with polar ligand provided potential solutions to the “on–off” problem and optimization in protein separation.  相似文献   

17.
The chromatographic behavior of six calix[n]arene phases (n=4, 6, 8) and one calix[4]resorcinarene phase is described for the separation of cis- and trans-isomers of three thioxanthene (flupentixol, clopenthixol, chlorprothixene) and one benz[b,e]oxepin derivative (doxepin). The influences of two different organic modifiers (MeOH, MeCN) for the separation of the isomers on every column are described. Different selectivities of the stationary phases exist as a function of the ring size of the calixarenes and their substitution at the "upper rim" with p-tert.-butyl groups. Furthermore, the influence of free phenol groups on the resorcinarene phase is discussed. Relations between structural elements of the analytes and the retention behavior on the stationary phases are found. The selectivity of the calixarene and resorcinarene stationary phases is compared with a RP-C18 phase containing the same base silica. Advantages of the resorcinarene as well as of the calixarene columns exist for the separation of cis- and trans-isomers of three compounds dependent from the substitution in position 2 of the thioxanthenes, respectively the kind of the basic side chain of all substances.  相似文献   

18.
Poly(ionic liquid)‐modified stationary phases can have multiple interactions with solutes. However, in most stationary phases, separation selectivity is adjusted by changing the poly(ionic liquid) anions. In this work, two poly(ionic liquid)‐modified silica stationary phases were prepared by introducing the cyano or tetrazolyl group on the pendant imidazolium cation on the polymer chains. Various analytes were selected to investigate their mechanism of retention in the stationary phases using different mobile phases. Two poly(ionic liquid)‐modified stationary phases can provide various interactions toward solutes. Compared to the cyano‐functionalized poly(ionic liquid) stationary phase, the tetrazolyl‐functionalized poly(ionic liquid) stationary phase provides additional cation‐exchange and π‐π interactions, resulting in different separation selectivity toward analytes. Finally, applicability of the developed stationary phases was demonstrated by the efficient separation of nonsteroidal anti‐inflammatory drugs.  相似文献   

19.
Adopting a stationary phase convention circumvents problematic definition of the boundary between the stationary and the mobile phase in the liquid chromatography, resulting in thermodynamically consistent and reproducible chromatographic data. Three stationary phase definition conventions provide different retention data, but equal selectivity: (i) the complete solid phase moiety; (ii) the solid porous part carrying the active interaction centers; (iii) the volume of the inner column pores. The selective uptake of water from the bulk aqueous‐organic mobile phase significantly affects the volume and the properties of polar stationary phases. Some polar stationary phases provide dual‐mode retention mechanism in aqueous‐organic mobile phases, reversed‐phase in the water‐rich range, and normal‐phase at high concentrations of the organic solvent in water. The linear solvation energy relationship model characterizes the structural contributions of the non‐selective and selective polar interactions both in the water‐rich and organic solvent‐rich mobile phases. The inner‐pore convention provides a single hold‐up volume value for the retention prediction on the dual‐mode columns over the full mobile phase range. Using the dual‐mode monolithic polymethacrylate zwitterionic micro‐columns alternatively in each mode in the first dimension of two‐dimensional liquid chromatography, in combination with a short reversed‐phase column in the second dimension, provides enhanced sample information.  相似文献   

20.
Retention and selectivity characteristics of different calixarene‐, resorcinarene‐ and alkyl‐bonded stationary phases are examined by analyzing a set of test solutes covering the main interactions (hydrophobic, steric, ionic, polar) that apply in HPLC. Therefore Dolan and Snyder's multiple term linear equation has been adapted to fit the properties of calixarene‐bonded columns. The obtained parameters are used to describe retention and selectivity of the novel Caltrex® phases and to elucidate underlying mechanisms of retention. Here, differences of stationary phase characteristics at different methanol concentrations in the mobile phases are examined. Both selectivity and retention were found to depend on the methanol content. Differences of these dependencies were found for different stationary phases and interactions. The differences between common alkyl‐bonded and novel calixarene‐bonded phases increase with increasing methanol content.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号