首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Min HK  Hyung SW  Shin JW  Nam HS  Ahn SH  Jung HJ  Lee SW 《Electrophoresis》2007,28(6):1012-1021
Capillary RPLC/ESI-MS (cRPLC/ESI-MS) is one of the most powerful analytical tools for current proteomic research. The development of cRPLC techniques coupled online to a mass spectrometer has focused on increasing the separation efficiency, detection sensitivity, and throughput. Recently, the use of high-pressure (over 10,000 psi) LC systems that utilize long, small inner diameter capillary columns has gained much attention for proteomic analyses. In this study, we developed an ultrahigh-pressure dual online SPE/capillary RPLC (DO-SPE/cRPLC) system. This LC system employs two online SPE columns and two capillary columns (75 microm inner diameter x 1 m length) in a single separation system, and has a maximum operating pressure of 10,000 psi. This DO-SPE/cRPLC system is capable of providing high-resolution separation in addition to several other advantageous features, such as high reproducibility in terms of the LC retention time, rapid sample injection, online desalting, online sample enrichment of dilute samples, and increased throughput as a result of essentially removing the column equilibration time between successive experiments. We coupled the DO-SPE/cRPLC system online to a tandem mass spectrometer to allow high-throughput proteomic analyses. In this paper, we demonstrate the efficiency of this DO-SPE/cRPLC/MS/MS system by its use in the analyses of proteomic samples exhibiting different levels of complexity.  相似文献   

2.
The Aria LX4 staggered parallel high performance liquid chromatography (HPLC) system is evaluated for application to good laboratory practice (GLP) level quantitative analysis by liquid chromatography/tandem mass spectrometry (LC/MS/MS). This system consists of four fully independent binary HPLC pumps, a modified autosampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Validation results for four different compounds, each analyzed on a separate channel of the Aria system, show precision and accuracy equivalent to that required of a single-channel system. The results show that sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The flexibility and ease of use of the Aria system suggest that it should be possible to quickly implement it in any analytical LC/MS/MS environment.  相似文献   

3.
In the present study, we report the application of LC‐MS based on two different LC‐MS systems to mycotoxin analysis. The mycotoxins were extracted with an ACN/water/acetic acid mixture and directly injected into a LC‐MS/MS system without any dilution procedure. First, a sensitive and reliable HPLC‐ESI‐MS/MS method using selected reaction monitoring on a triple quadrupole mass spectrometer (TSQ Quantum Ultra AM) has been developed for determining 32 mycotoxins in crude extracts of wheat and maize. This method was operated both in positive and in negative ionization modes in two separate chromatographic runs. The method was validated by studies of spiked recoveries, linearity, matrix effect, intra‐assay precision and sensitivity. Further, we have developed and evaluated a method based on accurate mass measurements of extracted target ions in full scan mode using micro‐LC‐LTQ‐Orbitrap as a tool for fast quantitative analysis. Both instruments exhibited very high sensitivity and repeatability in positive ionization mode. Coupling of micro‐LC to Orbitrap technology was not applicable to the negatively ionizable compounds. The LC triple quadrupole MS method has proved to be stable in quantitation, as it is with respect to the matrix effects of grain samples.  相似文献   

4.
There is a continuing need for increased throughput in the evaluation of new drug entities in terms of their pharmacokinetic (PK) parameters. This report describes an alternative procedure for increasing the throughput of plasma samples assayed in one overnight analysis: the use of parallel high performance liquid chromatography (HPLC) combined with tandem mass spectrometry (parallel LC/MS/MS). For this work, two HPLC systems were linked so that their combined effluent flowed into one tandem MS system. The parallel HPLC/APCI-MS/MS system consisted of two Waters 2690 Alliance systems (each one included an HPLC pump and an autosampler) and one Finnigan TSQ 7000 triple quadrupole mass spectrometer. Therefore, the simultaneous chromatographic separation of the plasma samples was carried out in parallel on two HPLC systems. The MS data system was able to deconvolute the data to calculate the results for the samples. Using this system, 20 compounds were tested in one overnight assay using the rapid rat PK screening model which includes a total of 10 standards plus samples and two solvent blanks per compound tested. This application provides an additional means of increasing throughput in the drug discovery PK assay arena; using this approach a two-fold increase in throughput can be achieved in the assay part of the drug discovery rat PK screening step.  相似文献   

5.
Quantification of small molecules using liquid chromatography/tandem mass spectrometry (LC/MS/MS) on a triple quadrupole mass spectrometer has become a common practice in bioanalytical support of in vitro adsorption, distribution, metabolism and excretion (ADME) screening. The bioanalysis process involves primarily three indispensable steps: MS/MS optimization for a large number of new chemical compounds undergoing various screening assays in early drug discovery, high-throughput sample analysis with LC/MS/MS for those chemically diverse compounds using the optimized MS/MS conditions, and post-acquisition data review and reporting. To improve overall efficiency of ADME bioanalysis, an integrated system was proposed featuring an automated and unattended MS/MS optimization, a staggered parallel LC/MS/MS for high-throughput sample analysis, and a sophisticated software tool for LC/MS/MS raw data review as well as biological data calculation and reporting. The integrated platform has been used in bioanalytical support of a serum protein binding screening assay with high speed, high capacity, and good robustness. In this new platform, a unique sample dilution scheme was also introduced. With this dilution design, the total number of analytical samples was reduced; therefore, the total operation time was reduced and the overall throughput was further improved. The performance of the protein binding screening assay was monitored with two controls representing high and low binding properties and an acceptable inter-assay consistency was achieved. This platform has been successfully used for the determination of serum protein binding in multiple species for more than 4000 compounds.  相似文献   

6.
7.
We report in this paper an ultra-performance liquid chromatography/tandem mass spectrometric (UPLC(R)/MS/MS) method utilizing an ESI-APCI multimode ionization source to quantify structurally diverse analytes. Eight commercial drugs were used as test compounds. Each LC injection was completed in 1 min using a UPLC system coupled with MS/MS multiple reaction monitoring (MRM) detection. Results from three separate sets of experiments are reported. In the first set of experiments, the eight test compounds were analyzed as a single mixture. The mass spectrometer was switching rapidly among four ionization modes (ESI+, ESI-, APCI-, and APCI+) during an LC run. Approximately 8-10 data points were collected across each LC peak. This was insufficient for a quantitative analysis. In the second set of experiments, four compounds were analyzed as a single mixture. The mass spectrometer was switching rapidly among four ionization modes during an LC run. Approximately 15 data points were obtained for each LC peak. Quantification results were obtained with a limit of detection (LOD) as low as 0.01 ng/mL. For the third set of experiments, the eight test compounds were analyzed as a batch. During each LC injection, a single compound was analyzed. The mass spectrometer was detecting at a particular ionization mode during each LC injection. More than 20 data points were obtained for each LC peak. Quantification results were also obtained. This single-compound analytical method was applied to a microsomal stability test. Compared with a typical HPLC method currently used for the microsomal stability test, the injection-to-injection cycle time was reduced to 1.5 min (UPLC method) from 3.5 min (HPLC method). The microsome stability results were comparable with those obtained by traditional HPLC/MS/MS.  相似文献   

8.
Inhibition curve shift is a commonly used approach for screening of time‐dependent CYP inhibitors which requires parallel paired incubations to obtain two inhibition curves for comparison. For the control incubation, a test compound is co‐incubated with a probe substrate in human liver microsomes (HLM) fortified with NADPH; for the time‐dependent incubation (TDI), the test compound is pre‐incubated with NADPH‐fortified HLM followed by a secondary incubation with a probe substrate. For both incubations, enzyme activity is measured respectively by liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis of the CYP‐specific metabolite, and a TDI inhibitor can be readily identified by inhibition curve shifting as a result of CYP inactivation by the test compound during the pre‐incubation. In the present study, we describe an alternative approach to facilitate TDI screening in which stable isotope labeled CYP‐specific probes are used for the TDI, and non‐labeled substrates are included in the control incubation. Because CYP‐specific metabolites produced in the TDI are stable isotope labeled, two sets of incubation samples can be combined and then simultaneously analyzed by LC/MS/MS in the same batch run to reduce the run time. This new method has been extensively validated using both a number of known competitive and TDI inhibitors specific to five most common CYPs such as 1A2, 2C9, 2C19, 2D6, and 3A4. The assay is performed in a 96‐well format and can be fully automated. Compared to the traditional method, this approach in combination with sample pooling and a short LC/MS/MS gradient significantly enhances the throughput of TDI screening and thus can be easily implemented in drug discovery to evaluate a large number of compounds without adding additional resource. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
This study describes application of liquid chromatography coupled with triple quadrupole mass spectrometry (LC‐MS) for evaluation of vitamin C stability, the objective being prediction of the degradation products. Detection was performed with an UV detector (UV‐Vis) in sequence with a triple‐quad mass spectrometer in the multiple reaction mode. The negative ion mode of ESI and MS‐MRM transitions of m/z 175→115 (quantifier) and 175→89 (qualifier) for ascorbic acid was used. All the validation parameters were within the range of acceptance proposed by the Food and Drug Administration. The method was fully validated in terms of linearity, LOD, LOQ, accuracy, and interday precision. Validation experiments revealed good linearity with R2 = 0.999 within the established concentration range, and excellent repeatability (9.3%). The LOD of the method was 0.1524 ng/mL whereas the LOQ was 0.4679 ng/mL. LC‐MS methodology proves to be an improved, simple, and fast approach to determining the content of vitamin C and its degradation products with high sensitivity, selectivity, and resolving power within 6 minutes of analysis.  相似文献   

10.
Amino acids are naturally occurring compounds in many edible or medicinal plants, which possess a variety of pharmacological effects on humans. The aim of this study is to develop and validate a hydrophilic interaction LC coupled with MS/MS method for the absolute and relative quantification of amino acids without derivatization. The application of this method has been proven through 20 naturally occurring amino acids in 21 samples from different parts and phenological growth stage of Sophora alopecuroides. The method was performed on an ultra‐high performance LC separation system coupled with ESI‐MS on a triple quadrupole mass spectrometer. The proposed absolute quantitative method was fully validated in terms of linearity, sensitivity, precision, repeatability as well as recovery. The analysis results showed that S. alopecuroides is rich in free amino acids. In addition, relative quantitative determination of amino acids with several amino acids selected for the best accuracy was investigated. The accuracies of relative quantitative method for amino acids determinations suggest that it is feasible to quantify amino acids by the proposed relative quantitative determination method, which contributes to breaking through the choke point of lack of standards.  相似文献   

11.
Liquid chromatography-mass spectrometry (LC/MS) has become one of the most widely used analytical techniques in both qualitative and quantitative analysis of small molecules. Recently, with the increasing demand for ever-higher sample throughput, the use of faster chromatographic separations has become popular, along with other LC/MS methods that decrease analytical cycle-time. The burgeoning use of LC/MS has meant that the primary expertise of many practitioners today is not in the field of LC/MS, which has been facilitated by the ease-of-use of modern LC/MS systems. An examination of the current state of the literature, relating to "fast LC/MS", should serve well to those new to LC/MS, and should help them in the development of fast LC/MS methods that are effective in terms of both the chromatography and the utilization of the mass spectrometer. This review paper focuses on fast LC/MS analyses of small molecules that have been reported in peer-reviewed publications.  相似文献   

12.
The preparation of protein substrates requires that a large number of chromatographic fractions be analyzed for the presence of reactants, products and by-products. Analyses using linear matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) or single column liquid chromatography/mass spectrometry (LC/MS) have been inadequate because of mass resolution or throughput. Therefore, a high-throughput method employing an eight-channel parallel reverse-phase LC/MS system was developed. This system is capable of screening fractions from preparative ion-exchange chromatography with the required mass accuracy and throughput so that the protein purification process can be monitored in a relatively short period of time. As an example, the purification and analysis of an acylated protein with a molecular weight of 8.9 kDa is described and the detection of a contaminating by-product that differs in size by less than 20 Da is demonstrated. Using the current instrumentation and approach, it is practical to analyze 50 protein-containing fractions from column chromatography in less than 1 hour using parallel LC/MS.  相似文献   

13.
The feasibility of high throughput on-line solid phase extraction/tandem mass spectrometry (SPE/MS/MS) is tested for target analysis of paclitaxel in human serum. The use of a dual Prospekt system, with parallel SPE and elution directly to the mass spectrometer, resulted in a cycle time of 80 seconds for the entire, fully automated assay. The assay proved to be linear from 1 to 1000 ng/mL. Cartridges packed with small sorbent particles functioned both as SPE cartridges and as short analytical columns.  相似文献   

14.
We have developed and implemented a novel mass spectrometry (MS) platform combining the advantages of high mass accuracy and resolving power of Fourier transform ion cyclotron resonance (FTICR) with the economy and speed of multiple ion traps for tandem mass spectrometry. The instruments are integrated using novel algorithms and software and work in concert as one system. Using chromatographic time compression, a single expensive FTICR mass spectrometer can match the throughput of multiple relatively inexpensive ion trap instruments. Liquid chromatography (LC)-mass spectrometry data from the two types of spectrometers are aligned and combined to hybrid datasets, from which peptides are identified using accurate mass from the FTICR data and tandem mass spectra from the ion trap data. In addition, the high resolving power and dynamic range of a 12 tesla FTICR also allows precise label-free quantitation. Using two ion traps in parallel with one LC allows simultaneous MS/MS experiments and optimal application of collision induced dissociation and electrontransfer dissociation throughout the chromatographic separation for increased proteome coverage, characterization of post-translational modifications and/or simultaneous measurement in positive and negative ionization mode. An FTICR-ion trap cluster can achieve similar performance and sample throughput as multiple hybrid ion trap-FTICR instruments, but at a lower cost. We here describe the first such FTICR-ion trap cluster, its performance and the idea of chromatographic compression.  相似文献   

15.
The identification of quantitative trait loci (QTL) for plant metabolites requires the quantitation of these metabolites across a large range of progeny. We developed a rapid metabolic profiling method using both untargeted and targeted direct infusion tandem mass spectrometry (DIMSMS) with a linear ion trap mass spectrometer yielding sufficient precision and accuracy for the quantification of a large number of metabolites in a high‐throughput environment. The untargeted DIMSMS method uses top‐down data‐dependent fragmentation yielding MS2 and MS3 spectra. We have developed software tools to assess the structural homogeneity of the MS2 and MS3 spectra hence their utility for phenotyping and genetical metabolomics. In addition we used a targeted DIMS(MS) method for rapid quantitation of specific compounds. This method was compared with targeted LC/MS/MS methods for these compounds. The DIMSMS methods showed sufficient precision and accuracy for QTL discovery. We phenotyped 200 individual Lolium perenne genotypes from a mapping population harvested in two consecutive years. Computational and statistical analyses identified 246 nominal m/z bins with sufficient precision and homogeneity for QTL discovery. Comparison of the data for specific metabolites obtained by DIMSMS with the results from targeted LC/MS/MS analysis showed that quantitation by this metabolic profiling method is reasonably accurate. Of the top 100 MS1 bins, 22 ions gave one or more reproducible QTL across the 2 years. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
The study of the metabolic fate of drugs is essential for the safety assessment of new compounds in the drug development process. However, the characterization and structural elucidation of metabolites from in vivo experiments is still a very challenging task. In this paper, we compare a two-dimensional liquid chromatography/mass spectrometry (LC/MS) approach using either a capillary LC/MS system or the recently introduced chip-based nanoelectrospray/MS system (Nanomate) as the second dimension for structural elucidation of metabolites by MS. More than 30 radioactive fractions of a chromatographic separation from a human urine sample were analyzed and 54 metabolites could be identified. The long persisting and stable nanoelectrospray enabled the search for unknown metabolites by precursor-ion scanning experiments followed by product-ion scanning experiments of potential metabolites using a quadrupole time-of-flight (qTOF) mass spectrometer. The number of fragments produced by nanoelectrospray with product-ion scanning was significantly higher compared to LC/MS experiments with in-source fragmentation. Therefore, the assignment of possible modifications in metabolites to certain moieties of the drug could be investigated with higher accuracy. The capillary LC/MS system for the second dimension was more sensitive in the case of low abundant metabolites. These metabolites could not be detected by direct nanoelectrospray infusion, which limits the application of the Nanomate for trace metabolites.  相似文献   

17.
The spatial distribution of proteins in tissue sections can be used to identify potential markers for pathological processes. Tissue sections are often subjected to enzymatic digestion before matrix‐assisted laser desorption/ionization (MALDI) imaging. This study is targeted at improving the on‐tissue identification of tryptic peptides by accurate mass measurements and complementary off‐line liquid chromatography coupled to electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) analysis. Two adjacent mouse brain sections were analyzed in parallel. The first section was spotted with trypsin and analyzed by MALDI imaging. Direct on‐tissue MS/MS experiments of this section resulted in the identification of 14 peptides (originating from 4 proteins). The second tissue section was homogenized, fractionated by ultracentrifugation and digested with trypsin prior to LC/ESI‐MS/MS analysis. The number of identified peptides was increased to 153 (corresponding to 106 proteins) by matching imaged mass peaks to peptides which were identified in these LC/ESI‐MS/MS experiments. All results (including MALDI imaging data) were based on accurate mass measurements (RMS <2 ppm) and allow a confident identification of tryptic peptides. Measurements based on lower accuracy would have led to ambiguous or misleading results. MS images of identified peptides were generated with a bin width (mass range used for image generation) of Δm/z = 0.01. The application of accurate mass measurements and additional LC/MS measurements increased both the quality and the number of peptide identifications. The advantages of this approach for the analysis of biological tissue sections are demonstrated and discussed in detail. Results indicate that accurate mass measurements are needed for confident identification and specific image generation of tryptic peptides in tissue sections. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

18.
As a continuation of our efforts to improve our high-flow on-line bioanalytical approach for high-throughput quantitation of drugs and metabolites in biological matrices by high-performance liquid chromatography (LC) and tandem mass spectrometry (MS/MS), we have developed a ternary-column on-line LC/MS/MS system with dual extraction columns used in parallel for purification and an analytical column for analysis. The advantage of the dual extraction column system is that sample analysis can take place in one of the extraction columns while the other column is being equilibrated. Thus, the equilibration time does not add to the run time, hence shortening the injection cycle time and increasing the sample throughput. Moreover, the use of two extraction columns in parallel increases the number of samples that can be injected before the system fails due to an overused extraction column. Such a system has successfully been used to develop and validate a positive ion electrospray LC/MS/MS bioanalytical method for the quantitative determination of a guanidine-containing drug candidate in rat plasma. The system used for this work utilized two Oasis HLB extraction columns (1 x 50 mm, 30 microm), one C18 analytical column (3.9 x 50 mm, 5 microm), a ten-port switching value and a tandem mass spectrometer. The on-line analysis was accomplished by the direct injection of 10 microL of the sample, obtained by mixing a rat plasma sample 1:1 with an aqueous internal standard solution. Selected reaction monitoring (SRM) was utilized for the detection of the analyte and internal standard. The standard curve range was 1.00-200 ng/mL. The intra- and inter-day precision and accuracy were within 6.6%. The on-line purification step lasted for only 0.3 min and total run time was only 1.6 min.  相似文献   

19.
A rapid, simple and sensitive LC–MS/MS method was established and validated for simultaneous quantification of ticagrelor and its active metabolite AR‐C124910XX in human plasma. After plasma samples were deproteinized with acetonitrile, the post‐treatment samples were chromatographed on a Dikma C18 column interfaced with a triple quadrupole tandem mass spectrometer. Electrospray negative ionization mode and multiple reaction monitoring were adopted to assay ticagrelor and AR‐C124910XX. Acetonitrile and 5 mΜ ammonium acetate was used as the mobile phase with a gradient elution at a flow rate of 0.5 mL/min. The method was linear in the range of 0.781–800 ng/mL for both ticagrelor and AR‐C124910XX with a correlation coefficient ≥0.994. The intra‐ and inter‐day precisions were within 12.61% in terms of relative standard deviation and the accuracy was within ±7.88% in terms of relative error. The LC–MS/MS method was fully validated for its sensitivity, selectivity, stability, matrix effect and recovery. This convenient and specific LC–MS/MS method was successfully applied to the pharmacokinetic study of ticagrelor and AR‐C124910XX in healthy volunteers after an oral dose of 90 mg ticagrelor.  相似文献   

20.
The detection of the reactive metabolites of drugs has recently been gaining increasing importance. In vitro trapping studies using trapping agents such as glutathione are usually conducted for the detection of reactive metabolites, especially those of cytochrome P450‐mediated metabolism. In order to detect the UDP‐glucuronosyltransferase (UGT)‐mediated bioactivation of drugs, an in vitro trapping method using N‐acetylcysteine (NAC) as a trapping agent followed by liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed in this study. After the test compounds (diclofenac and ketoprofen) had been incubated in human liver microsomes with uridine diphosphoglucuronic acid (UDPGA) and NAC, the NAC adducts formed through their acyl glucuronides were analyzed using LC/MS/MS with electrospray ionization (ESI). The NAC adduct showed a mass shift of 145 units as compared to its parent, and the characteristic ion fragmentations reflected the parent. This is a concise and high‐throughput method for evaluating reactive metabolites by UGT‐mediated bioactivation. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号