首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
陈瑞清  俞道进  陈锋  黄一帆 《色谱》2010,28(10):997-1000
建立了测定鸡肉组织中癸氧喹酯(DEC)残留的高效液相色谱-串联质谱(HPLC-MS/MS)方法。样品经乙腈提取,正己烷脱脂,固相萃取(SPE)小柱净化;采用0.1%甲酸乙腈溶液-0.1%甲酸水溶液(78:22, v/v)为流动相,电喷雾正离子电离(ESI+)模式,多反应监测(MRM)检测模式,以内标法进行定量。结果表明: DEC在1~200 μg/L范围内呈良好的线性关系,相关系数(r2)大于0.99; 1、10、100 μg/kg 3个添加水平的回收率为78.2%~107.4%,日内、日间相对标准偏差(RSD)均小于15%,方法检出限为0.25 μg/kg,定量限为0.5 μg/kg。该方法简便、灵敏、精确,可用于鸡肉组织中DEC药物残留的确证检测。  相似文献   

2.
The recent worldwide shortage of acetonitrile has prompted interest in alternative solvents for liquid chromatography/mass spectrometry (LC/MS). In this work, acetone was substituted for acetonitrile in the separation of a peptide mixture by reversed‐phase high‐performance liquid chromatography (RP‐HPLC) and in the positive electrospray ionization mass spectrometry (ESI‐MS) of individual peptides. On both C12 and C18 stationary phases, the substitution of acetone for acetonitrile as the organic component of the mobile phase did not alter the gradient elution order of a five‐peptide retention standard, but did increase peak width, shorten retention times, and increase peak tailing. Positive ESI mass spectra were obtained for angiotensin I, bradykinin, [Leu5]‐enkephalin, and somatostatin 14 dissolved in both acetonitrile/water/formic acid (25%/75%/0.1%) and acetone/water/formic acid (25%/75%/0.1%). Under optimized ESI‐MS conditions, the mass spectral response of [Leu5]‐enkephalin was increased two‐fold when the solvent contained acetone. The substitution of acetone for acetonitrile resulted in only slight changes in the responses of the remaining peptides. A higher capillary voltage was required for optimum response when acetone was used. Compared with acetonitrile/water/formic acid (50/50/0.1%), more interfering species below m/z = 140 were found in the ESI‐MS spectra of acetone/water/formic acid (50/50/0.1%). Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
液相色谱-串联质谱法测定鸡组织中沃尼妙林残留   总被引:1,自引:0,他引:1  
建立了鸡组织中沃尼妙林残留的液相色谱-电喷雾串联质谱(LC-ESI-MS /MS) 检测方法.样品用乙腈提取后,过Strata-X-C固相萃取小柱净化.以乙腈-0.1%甲酸水溶液(35∶ 65,V/V)为流动相,经Luna C18色谱柱分离,采用电喷雾电离,多反应监测(MRM)正离子模式对沃尼妙林进行定性与定量分析.采用基质匹配法,对鸡皮肤、肌肉、肾脏和肝脏中沃尼妙林的含量进行标准校正,在5(7.5)~500 μg/kg范围内线性良好(r>0 998),在鸡肝脏中的检出限(LOD)及定量限(LOQ)分别为4.0和7.5 μg/kg;其它3种组织中的LOD及LOQ分别为2.5和5.0 μg/kg.在5(7.5), 50及500 μg/kg添加水平下,4中组织中沃尼妙林的平均回收率为78 5%~104.0%.日内相对标准偏差(RSD)为1.2%~9.8%,日间相对标准偏差为3.7%~13.2%.  相似文献   

4.
In this study, a polarization‐induced electrospray ionization mass spectrometry (ESI‐MS) was developed. A micro‐sized sample droplet was deposited on a naturally available dielectric substrate such as a fruit or a stone, and then placed close to (~2 mm) the orifice of a mass spectrometer applied with a high voltage. Taylor cone was observed from the sample droplet, and a spray emitted from the cone apex was generated. The analyte ion signals derived from the droplet were obtained by the mass spectrometer. The ionization process is similar to that in ESI although no direct electric contact was applied on the sample site. The sample droplet polarized by the high electric field provided by the mass spectrometer initiated the ionization process. The dielectric sample loading substrate facilitated further the polarization process, resulting in the formation of Taylor cone. The mass spectral profiles obtained via this approach resembled those obtained using ESI‐MS. Multiply charged ions dominated the mass spectra of peptides and proteins, whereas singly charged ions dominated the mass spectra of small molecules such as amino acids and small organic molecules. In addition to liquid samples, this approach can be used for the analysis of solid and viscous samples. A small droplet containing suitable solvent (5–10 µl) was directly deposited on the surface of the solid (or viscous) sample, placed close the orifice of mass spectrometer applied with a high voltage. Taylor cone derived from the droplet was immediately formed followed by electrospray processes to generate gas‐phase ions for MS analysis. Analyte ions derived from the main ingredients of pharmaceutical tablets and viscous ointment can be extracted into the solvent droplet in situ and observed using a mass spectrometer. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

5.
In liquid chromatography/mass spectrometry (LC/MS) of 1,3,5-trinitro-1,3,5-triazacyclohexane (RDX), attachment of an anion to the analyte molecule is the major way of producing characteristic ions under electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) conditions. The formation of RDX cluster ions in LC/MS and the origin of the clustering agents have been studied. In order to determine whether the clustering anions originate from self-decomposition of RDX in the source or from impurities in the mobile phase, isotopically labeled RDX ((13)C(3)-RDX and (15)N(6)-RDX) and isotopically labeled glycolic acid, acetic acid, ammonium formate and formaldehyde have been used in order to establish the composition and formation route of RDX adduct ions produced in ESI and APCI sources. The results showed that, in ESI, self-decomposition of RDX plays no role in adduct ion formation; rather, RDX clusters with formate, acetate, hydroxyacetate, and chloride anions present in the mobile phase as impurities at ppm levels. In APCI, part of the RDX molecules decompose yielding NO(2) (-) species which in turn cluster with a second RDX molecule producing abundant [M+NO(2)](-) cluster ions.  相似文献   

6.
We report a cyclic sample pooling technique devised in two‐dimensional liquid chromatography–electrospray ionization mass spectrometry (LC‐ESI‐MS) shotgun proteomics that renders deeper proteome coverage; we combined low pH reversed‐phase (RP) LC in trifluoroacetic acid in the first dimension, followed by cyclic sample pooling of the eluate and low‐pH RP‐LC in formic acid in the second dimension. The new protocol has a significantly higher resolving power suitable for LC‐ESI‐MS/MS shotgun proteomics. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
A simple, rapid, sensitive and specific liquid chromatography/tandem mass spectrometry method was developed and validated to quantify troxerutin in human plasma. The analyte and rutin, used as the internal standard, were analyzed on a Phenomenex Synergi Fusion RP column interfaced with a triple-quadrupole tandem mass spectrometer using positive electrospray ionization. Acetonitrile/water (20:80 v/v) was used as the isocratic mobile phase, with 0.1% formic acid in water. A simple sample preparation method of protein precipitation with perchloric acid was employed. The assay was linear over the concentration range 31.25-4000 pg/mL. Correlation coefficients generated by linear regression with a 1/x(2) weighting factor ranged from 0.9991 to 0.9996. The intra- and inter-day precision over the entire concentration range were less than 12.28%. The method was successfully applied to a pharmacokinetic study after oral administration of a 300 mg troxerutin drop pill to 18 healthy volunteers.  相似文献   

8.
Ultra‐performance hydrophilic interaction liquid chromatography (UPHILIC) interfaced with the electrospray ionization (ESI) source of a tandem mass spectrometer (MS/MS) was developed for the simultaneous determination of everolimus in mouse plasma samples. UPHILIC was performed on a sub‐2 µm bare silica particle packing with the column pressure under traditional high‐performance liquid chromatography (HPLC) to allow fast separation of pharmaceutical compounds within a chromatographic analysis time of 1 min. This UPHILIC technology is comparable with reversed‐phase ultra‐performance liquid chromatography (RPUPLC) in terms of chromatographic efficiency but demands neither expensive ultra‐high‐pressure instrumentation nor new laboratory protocols. With the ESI source, multiple reaction monitoring (MRM) of the ammoniated adduct ions of the analyte was used for tandem mass spectrometric detection. The retention mechanism profiles of the test compounds under HILIC conditions were explored. The influences of experimental factors such as the compositions of mobile phases on the chromatographic performance and the ionization efficiency of the test compounds in positive ion mode were investigated. A UPHILIC/MS/MS approach following a protein precipitation procedure was applied for the quantitative determination of everolimus at the low ng/mL region in support of a pharmacodynamic study. The analytical results obtained by the UPHILIC/MS/MS approach were fond to be in good agreement with those obtained by the RPUPLC/MS/MS method in terms of assay sample throughput, sensitivity and accuracy. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Electrospray ionization (ESI) is commonly used in macromolecular mass spectrometry, yet the dynamics of macromolecules in ESI droplets are not well understood. In this study, a Monte Carlo based model was developed, which can predict the efficiency of electrospray ionization for macromolecules, i.e., the number of macromolecular ions produced per macromolecules electrosprayed. The model takes into account ESI droplet evaporation, macromolecular diffusion within the droplet, droplet fissions, and the statistical nature of the ESI process. Two idealized representations of macromolecular analytes were developed, describing cluster prone, droplet surface inactive macromolecules and droplet surface active macromolecules, respectively. It was found that surface active macromolecules are preferentially ionized over surface inactive cluster prone macromolecules when the initial droplet size is large and the analyte concentration in solution is high. Simulations showed that ESI efficiency decreases with increasing initial droplet size and analyte molecular weight, and is influenced by analyte surface activity, the properties of the solvent, and the variance of the droplet size distribution. Model predictions are qualitatively supported by experimental measurements of macromolecular electrospray ionization made previously. Overall, this study demonstrates the potential capabilities of Monte Carlo based ESI models. Future developments in such models will allow for more accurate predictions of macromolecular ESI intensity.  相似文献   

10.
Aripiprazole is an important antipsychotic drug. A simple, sensitive and rapid ultra‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (UPLC‐ESI‐MS/MS) method was developed and validated for the simultaneous quantification of this compound in rat plasma and brain homogenate. The analyte was extracted from rat plasma and brain homogenate using a weak cation exchange mixed‐mode resin‐based solid phase extraction. The compound was separated on an Agilent Eclipse Plus C18 (2.1 × 50 mm, 1.8 µm) column using a mobile phase of (A) 0.1% formic acid aqueous and (B) acetonitrile with gradient elution. The analyte was detected in positive ion mode using multiple reaction monitoring. The method was validated and the specificity, linearity, limit of quantitation (LOQ), precision, accuracy, recoveries and stability were determined. The LOQ was 0.5 ng/mL for aripiprazole in plasma and 1.5 ng/g in brain tissue. The MS response was linear over the concentration range 0.5–100 ng/mL for aripiprazole in plasma and 1.5–300 ng/g in brain tissue. The precision and accuracy for intra‐day and inter‐day were better than 14%. The relative and absolute recoveries were above 72% and the matrix effects were low. This validated method was successfully used to quantify the rat plasma and brain tissue concentrations of the analyte following chronic treatment with aripiprazole. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
本文采用高效液相色谱与电喷雾质谱联用技术在线分析鉴定了车前草提取物中的三种苯乙醇苷化合物。实验采用反相C18色谱柱,0.2%的醋酸水溶液和乙腈梯度洗脱,车前草中的苯乙醇苷化合物得到很好的分离。在电喷雾质谱负离子条件下,获得了三种苯乙醇苷化合物的分子离子峰,分子量信息,进一步通过质谱的源内CID技术得到相应化合物的结构信息。通过得到的这些信息与文献中的已知化合物或标准品对照从而推断出化合物的结构。  相似文献   

12.
In this work, a liquid chromatography–tandem mass spectrometric detection technique was developed and validated for the determination of brotizolam residues in beef muscle and commercial whole milk. This procedure involves the extraction of the analyte from the samples via liquid–solid extraction, and caffeine was used as an internal standard. The analyte was successfully separated on an XTerra‐C18 column, with a mobile phase composed of 0.01% formic acid in acetonitrile and 1 mm ammonium formate–0.01% formic acid in water. The one‐step extraction method evidenced good selectivity, precision (RSD = 9.87–26.47%), and the recovery of the extractable analyte was 92.61–115.98% in the matrices. The limits of quantification ranged between 0.4 and 0.5 µg/kg. The developed method is simple since it requires no additional cleanup procedures. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
A new, fast and sensitive high‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI‐MS/MS) method was developed and validated for isovalerylshikonin in rat plasma using emodin as internal standard (IS). The analyte was extracted from rat plasma with ethyl acetate, after 10% HCl treatment and protein precipitated by methanol. The compound was separated on an Ultimate? XB‐C18 analytical column using a mobile phase of methanol–10 mM ammonium acetate in water–acetonitrile containing 0.05% formic acid (45 : 10 : 45, v/v/v) with isogradient elution. The analyte was detected in negative ion mode using multiple‐reaction monitoring. The method was validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. LLOQ was 9 ng/mL for isovalerylshikonin. Correlation coefficient (r) value for the linear range of the analyte was greater than 0.99. The intra‐day and inter‐day precision and accuracy were better than 8.52%. The relative and absolute recovery was above 86% and no matrix effects were observed for isovalerylshikonin. This validated method provides a modern, rapid and robust procedure for the pharmacokinetic study of the two compounds in rats after intravenous administration to rats (n = 4). Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
A sensitive, rapid and specific quantitative liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for the determination of apomorphine (APO) in canine plasma. The analytes were prepared using one-step liquid-liquid extraction, and analyzed on a Waters Symmetry C(18) column interfaced with triple quadrupole tandem mass spectrometer. A mixture of methanol/0.1% formic acid in water (70: 30, v/v) was employed as the isocratic mobile phase. Positive electrospray ionization was utilized as the ionization source. The analyte and clenbuterol (internal standard) were both detected using multiple reaction monitoring (MRM) mode. The limit of detection (LOD) obtained was 0.03 ng/mL. The assay was linear over the concentration range of 0.1-100 ng/mL, and provided good precision (RSD) and good accuracy (RE). The analyte was stable by using antioxidants throughout the whole study. The experimental results show that LC/MS/MS is a rapid and sensitive method to analyze APO in plasma. Finally, the proposed method was successfully applied to a pharmacokinetic study of APO after intranasal administration of 0.5 mg apomorphine to 10 healthy beagle dogs.  相似文献   

15.
A derivatization procedure has been developed for the improved characterization of fatty alcohol ethoxylate non‐ionic surfactants by liquid chromatography/mass spectrometry. The end hydroxyl group of each surfactant species was converted into an oxycarbonylbenzene‐2‐sulfonic acid group with 2‐sulfobenzoic anhydride under mild conditions. The produced sulfonic acid group allows all species, including fatty alcohols and those with less than three ethoxylates, to be uniformly ionized by electrospray ionization (ESI) mass spectrometry. Both acid and base can be used as a mobile phase additive for liquid chromatography without affecting Mn and average ethoxylate values, although ion intensities are suppressed during the ESI process. The method was used to analyze seven commercial fatty alcohol ethoxylate non‐ionic surfactants, and the determined Mn and EO values were comparable with the results obtained by NMR. The relative ratio of different fatty alcohol based ethoxylates in a sample can also be determined using the summed mass spectral data. Copyright © 2009 The Dow Chemical Company  相似文献   

16.
In the present study, an ultra-performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) approach was designed to measure the rat plasma levels of verubecestat with diazepam as the internal standard. Acetonitrile-based protein precipitation was applied for sample preparation, then the analyte verubecestat was subjected to gradient elution chromatography with a mobile phase composed of acetonitrile (A) and 0.1% formic acid in water (B). Verubecestat was monitored by m/z 410.1 → 124.0 transition for quantification by multiple reaction monitoring (MRM) in positive ion electrospray ionization (ESI) source. When the concentration of verubecestat ranged from 1 to 2500 ng/mL, the method exhibited good linearity. For verubecestat, the intra- and inter-day precision were determined with the values of 2.9–9.0% and 0.4–6.5%, respectively; and the accuracy ranged from −2.2% to 10.4%. Matrix effect, extraction recovery, and stability data were in line with the standard FDA guidelines for validating a bioanalytical method. The validity of the developed method was confirmed through the pharmacokinetic study.  相似文献   

17.
The separation of basic macrolide antibiotics suffers from peak tailing and poor efficiency on traditional silica‐based reversed‐phase liquid chromatography columns. In this work, a C18HCE column with positively charged surface was applied to the separation of macrolides. Compared with an Acquity BEH C18 column, the C18HCE column exhibited superior performance in the aspect of peak shape and separation efficiency. The screening of mobile phase additives including formic acid, acetic acid and ammonium formate indicated that formic acid was preferable for providing symmetrical peak shapes. Moreover, the influence of formic acid content was investigated. Analysis speed and mass spectrometry compatibility were also taken into account when optimizing the separation conditions for liquid chromatography coupled with tandem mass spectrometry. The developed method was successfully utilized for the determination of macrolide residues in a honey sample. Azithromycin was chosen as the internal standard for the quantitation of spiramycin and tilmicosin, while roxithromycin was used for erythromycin, tylosin, clarithromycin, josamycin and acetylisovaleryltylosin. Good correlation coefficients (r2 > 0.9938) for all macrolides were obtained. The intra‐day and inter‐day recoveries were 73.7–134.7% and 80.7–119.7% with relative standard deviations of 2.5–8.0% and 3.9–16.1%, respectively. Outstanding sensitivity with limits of quantitation (S/N ≥ 10) of 0.02–1 μg/kg and limits of detection (S/N ≥ 3) of 0.01–0.5 μg/kg were achieved.  相似文献   

18.
建立了水果中烯唑醇残留量的高效液相色谱-串联质谱(LC-MS/MS)测定方法。样品采用丙酮-正己烷液液振荡提取,经分散固相萃取(DSPE)净化后,采用ODS-C18柱为分离柱,以乙腈-0.1%甲酸溶液为流动相,采用液相色谱-串联质谱(ESI)多反应监测(MRM)正离子模式测定,外标法定量。烯唑醇在0.002~0.2 mg//L质量浓度范围内线性关系良好,方法定量下限(LOQ)为0.001 mg/kg。在0.005~0.1 mg/kg之间的3个添加浓度水平下,添加回收率为78.8 %~108.0 %,相对标  相似文献   

19.
An automated online solid‐phase extraction with liquid chromatography and tandem mass spectrometry method was developed and validated for the detection of clenbuterol, salbutamol, and ractopamine in food of animal origin. The samples from the food matrix were pretreated with an online solid‐phase extraction cartridge by Oasis MCX for <5 min after acid hydrolysis for 30 min. The peak focusing mode was used to elute the target compounds directly onto a C18 column. Chromatographic separation was achieved under gradient conditions using a mobile phase composed of acetonitrile/0.1% formic acid in aqueous solution. Each analyte was detected in two multiple reaction monitoring transitions via an electrospray ionization source in a positive mode. The relative standard deviations ranged from 2.6 to 10.5%, and recovery was between 76.7 and 107.2% at all quality control levels. The limits of quantification of three β‐agonists were in the range of 0.024–0.29 μg/kg in pork, sausage, and milk powder, respectively. This newly developed method offers high sensitivity and minimum sample pretreatment for the high‐throughput analysis of β‐agonist residues.  相似文献   

20.
Ionic chemical background noise in LC-MS has been one of the major problems encountered in trace analysis. In this study, the typical negative background ions in ESI LC-MS are investigated exemplarily. It was carried out using tandem mass spectrometry to study the products and precursors of the major background ions to examine their structures and structure relationship. Various typical LC eluents with different compositions and additives such as ammonium formate/formic acid and ammonium acetate/acetic acid have been studied. Several types of negative noise ions are concluded, which include the cluster chemical background ions only from mobile phase components and additives. Furthermore, there are also abundant clusters resulting from the solvation of some typical individual contaminants (e.g. additives and degradation products from tubing, impurities in the mobile phase, etc.), accompanied by some minor contribution from contaminants. The elemental composition of some selected ions was confirmed using the FT-ICR accurate mass measurement. This work provides us insight into information about the structures and types of common negative background ions and will help to understand their formation and origins. More importantly, it will guide us to prevent chemical noise interference in practice and also contribute to develop methods for noise reduction based on selective ion-molecule reactions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号