A solid‐phase microextraction coupled with gas chromatography and mass spectrometry method has been developed for the determination of ten nitrated polycyclic aromatic hydrocarbons in water samples. Five different kinds of commerical fibers were used to compare the extraction efficiency, including 65 μm polydimethylsiloxane/divinylbenzene, 100 μm polydimethylsiloxane, 30 μm polydimethylsiloxane, 7 μm polydimethylsiloxane, and 85 μm polyacrylate fibers. Five factors were also selected to optimize conditions, including extraction temperature, time, stirring speed, salt concentration, and headspace volume. Taguchi design was applied to design the experiments and obtain the best parameters. The results show that 65 μm polydimethylsiloxane/divinylbenzene fiber directly immersed into aqueous solution for 35 min at 55°C with a constant stirring rate of 1150 rpm were the optimal conditions. Under these conditions, the limits of quantification were 0.007–0.063 μg/L, and the relative standard deviation based on six replicates ranged from 2.8 to 9.5%. The spiked recoveries ranged from 69.1 to 110.1%. Intra‐ and inter day relative standard deviations at three concentration levels were less than 12%, and the recoveries were 66.4–111.5%. The proposed method is reliable for analyzing nitrated polycyclic aromatic hydrocarbons in different water samples.  相似文献   

2.
A method for the determination of polycyclic aromatic hydrocarbons (PAHs) in soil samples using ultrasonic‐assisted extraction with internal surrogates combined with solid‐phase microextraction and GC‐MS has been developed. Five kinds of commercial solid‐phase microextraction fibers, 100 μm PDMS, 30 μm PDMS, 65 μm PDMS/DVB, 50 μm DVB/CAR/PDMS and 85 μm PA, were compared to choose the optimal SPME fiber for extraction of PAHs. One hundred micrometers of PDMS fiber was found to be more suitable for the determination of PAHs due to its wider linear range, better repeatability, lower detection and more satisfactory efficacy than the other fibers. Under the recommended conditions, 100 μm PDMS fiber could provide low nanogram level detection limits with correlation coefficient greater than 0.98. The method was also applied to determine PAHs in a spiked soil sample, obtaining recoveries higher than 79.3%. A field study with naturally contaminated samples from local contaminated sites was carried out. The proposed method was found to be a reliable, inexpensive and simple preparation method for quantitative determination of 16 PAHs in soil samples.  相似文献   

3.
A highly porous fiber coated with polythiophene/hexagonally ordered silica nanocomposite was prepared for solid‐phase microextraction (SPME). The prepared nanomaterial was immobilized onto a stainless‐steel wire for the fabrication of the SPME fiber. Polythiophene/hexagonally ordered silica nanocomposite fibers were used for the extraction of some polycyclic aromatic hydrocarbons from water samples. The extracted analytes were transferred to the injection port of a gas chromatograph using a laboratory‐designed SPME device. The results obtained prove the ability of the polythiophene/hexagonally ordered silica material as a new fiber for the sampling of organic compounds from water samples. This behavior is due most probably to the increased surface area of the polythiophene/hexagonally ordered silica nanocomposite. A one‐at‐a‐time optimization strategy was applied for optimizing the important extraction parameters such as extraction temperature, extraction time, ionic strength, stirring rate, and desorption temperature and time. Under the optimum conditions, the LOD of the proposed method is 0.1–3 pg/mL for analysis of polycyclic aromatic hydrocarbons from aqueous samples, and the calibration graphs were linear in a concentration range of 0.001–20 ng/mL (R2 > 0.990) for most of the polycyclic aromatic hydrocarbons. The single fiber repeatability and fiber‐to‐fiber reproducibility were less than 8.6 and 19.1% (n = 5), respectively.  相似文献   

4.
A novel design of hollow‐fiber liquid‐phase microextraction containing multiwalled carbon nanotubes as a solid sorbent, which is immobilized in the pore and lumen of hollow fiber by the sol–gel technique, was developed for the pre‐concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples. The proposed method utilized both solid‐ and liquid‐phase microextraction media. Parameters that affect the extraction of polycyclic aromatic hydrocarbons were optimized in two successive steps as follows. Firstly, a methodology based on a quarter factorial design was used to choose the significant variables. Then, these significant factors were optimized utilizing central composite design. Under the optimized condition (extraction time = 25 min, amount of multiwalled carbon nanotubes = 78 mg, sample volume = 8 mL, and desorption time = 5 min), the calibration curves showed high linearity (R 2 = 0.99) in the range of 0.01–500 ng/mL and the limits of detection were in the range of 0.007–1.47 ng/mL. The obtained extraction recoveries for 10 ng/mL of polycyclic aromatic hydrocarbons standard solution were in the range of 85–92%. Replicating the experiment under these conditions five times gave relative standard deviations lower than 6%. Finally, the method was successfully applied for pre‐concentration and determination of polycyclic aromatic hydrocarbons in environmental water samples.  相似文献   

5.
An inorganic–organic hybrid nanocomposite (zinc oxide/polypyrrole) that represents a novel kind of coating for in‐tube solid‐phase microextraction is reported. The composite coating was prepared by a facile electrochemical polymerization strategy on the inner surface of a stainless‐steel tube. Based on the coated tube, a novel online in‐tube solid‐phase microextraction with liquid chromatography and mass spectrometry method was developed and applied for the extraction of three monohydroxy polycyclic aromatic hydrocarbons in human urine. The coating displayed good extraction ability toward monohydroxy polycyclic aromatic hydrocarbons. In addition, long lifespan, excellent stability, and good compression resistance were also obtained for the coating. The experimental conditions affecting the extraction were optimized systematically. Under the optimal conditions, the limits of detection and quantification were in the range of 0.039–0.050 and 0.130–0.167 ng/mL, respectively. Good linearity (0.2–100 ng/mL) was obtained with correlation coefficients larger than 0.9967. The repeatability, expressed as relative standard deviation, ranged between 2.5% and 9.4%. The method offered the advantage of process simplicity, rapidity, automation, and sensitivity in the analysis of human urinary monohydroxy polycyclic aromatic hydrocarbons in two different cities of Hubei province. An acceptable recovery of monohydroxy polycyclic aromatic hydrocarbons (64–122%) represented the additional attractive features of the method in real urine analysis.  相似文献   

6.
A novel mesoporous‐coated stainless steel wire microextraction coupled with the HPLC procedure for quantification of four polycyclic aromatic hydrocarbons in water has been developed, based on the sorption of target analytes on a selectively adsorptive fiber and subsequent desorption of analytes directly into HPLC. Phenyl‐functionalized mesoporous materials (Ph‐SBA‐15) were synthesized and coated on the surfaces of a stainless steel wire. Due to the high porosity and large surface area of the Ph‐SBA‐15, high extraction efficiency is expected. The influence of various parameters on polycyclic aromatic hydrocarbons extraction efficiency were thoroughly studied and optimized (such as the extraction temperature, the extraction time, the desorption time, the stirring rate and the ionic strength of samples). The results showed that each compound for the analysis of real water samples was tested under optimal conditions with the linearity ranging from 1.02×10?3 to 200 μg/ L and the detection limits were found from 0.32 to 2.44 ng/ L, respectively. The RSD of the new method was smaller than 4.10%.  相似文献   

7.
Graphene has great potentials for the use in sample preparation due to its ultra high specific surface area, superior chemical stability, and excellent thermal stability. In our work, a novel graphene‐based SPE disk was developed for separation and preconcentration of trace polycyclic aromatic hydrocarbons from environmental water samples. Based on the strong π–π stacking interaction between the analytes and graphene, the analytes extracted by graphene were eluted by cyclohexane and then determined by GC‐MS. Under the optimized conditions, high flow rate (30 mL/min) and sensitivity (0.84–13 ng/L) were achieved. The proposed method was successfully applied to the analysis of real environmental water samples with recoveries ranging from 72.8 to 106.2%. Furthermore, the property of anticlogging and reusability was also improved. This work reveals great potentials of graphene‐based SPE disk in environmental analytical.  相似文献   

8.
A fiber‐in‐tube solid‐phase microextraction device based on a gold‐functionalized stainless‐steel wire and tube was developed and characterized by scanning electron microscopy and energy dispersive X‐ray spectroscopy. In combination with high‐performance liquid chromatography, it was evaluated using six polycyclic aromatic hydrocarbons as model analytes. Important parameters including sampling rate, sample volume, organic solvent content and desorption time were investigated. Under optimized conditions, an online analysis method was established. The linearity was in the range of 0.15–50 μg/L with correlation coefficients ranging from 0.9989 to 0.9999, and limits of detection ranged from 0.05 to 0.1 μg/L. The method was applied to determine model analytes in mosquito‐repellent incense ash and river water samples, with recoveries in the range of 85–120%.  相似文献   

9.
Silk fibers were carbonized to develop a biomass carbon material as an adsorbent for solid‐phase microextraction. The surface structure of the carbonized silk fibers was characterized by scanning electron microscopy, and the graphitization degree was determined by Raman spectrometry. After carbonization under high temperature, the orderliness and structural regularity of carbon atoms on silk fibers were promoted. Extraction tube packed with carbonized silk fibers was prepared for in‐tube solid‐phase microextraction. Coupled with high performance liquid chromatography, it exhibited good extraction performance for hydrophobic polycyclic aromatic hydrocarbons. Main parameters including sampling volume, sampling rate, methanol content in sample, and desorption time were systematically investigated. Under the optimum conditions, the analysis method was established and it exhibited wide linear range (0.016–20 μg/L) with good linearity (correlation coefficient ≥ 0.9947), low limits of detection (0.005–0.050 μg/L), and high enrichment factors (1189–2775). Relative standard deviations (n = 3) for intraday (≤3.3%) and interday (≤9.6%) tests indicated that the extraction material had satisfactory repeatability. Finally, the analytical method was successfully applied to detect trace polycyclic aromatic hydrocarbons in real water samples, demonstrating its satisfactory practicability.  相似文献   

10.
A simple and rapid solid‐phase microextraction approach for the isolation of polycyclic aromatic sulfur heterocycles from the aromatic fraction of crude oil is described. 8‐Hydroxyquinoline silica gel impregnated with palladium chloride was used as a sorbent material for extraction. Operational parameters of the extraction solvents have been evaluated and optimized. Benzothiophene, dibenzothiophene, and benzo[b]naphtho[1,2‐d]thiophene and their C1–C4 alkyl derivatives were identified and quantified by GC–MS. Under optimum conditions, the limits of detection for benzothiophene, dibenzothiophene, and benzo[b]naphtho[1,2‐d]thiophene were 0.277, 0.193, and 0.597 μg/g oil, respectively. The recoveries for the polycyclic aromatic sulfur heterocycles ranged from 81.5 to 92.1%, and the linear dynamic range was from 10 to 1000 ng/mL. The developed methodology was tested in the characterization of crude oil samples collected at the DY, SZ, ZH, and HC petroleum oil fields of the Bohai Sea. The results proved that SPE coupled with GC–MS is a promising tool for the quantitative analysis of polycyclic aromatic sulfur heterocycles in crude oils, especially for oil samples with low concentrations of polycyclic aromatic sulfur heterocycles.  相似文献   

11.
A solid‐phase microextraction with carbon nanospheres coated fiber coupled with gas chromatographic detection was established for the determination of eight polycyclic aromatic hydrocarbons (naphthalene, biphenyl, acenaphthene, fluorine, phenanthrene, anthracene, fluoranthene, and pyrene) in water and soil samples. The experimental parameters (extraction temperature, extraction time, stirring rate, headspace volume, salt content, and desorption temperature) which affect the extraction efficiency were studied. Under the optimized conditions, good linearity between the peak areas and the concentrations of the analytes was achieved in the concentration range of 0.5‐300 ng/mL for water samples, and in the concentration range of 6.0‐2700 ng/g for soil samples. The detection limits for the analytes were in the range of 0.12‐0.45 ng/mL for water samples, and in the range of 1.53‐2.70 ng/g for soil samples. The method recoveries of the polycyclic aromatic hydrocarbons for spiked water samples were 80.10‐120.1% with relative standard deviations less than 13.9%. The method recoveries of the analytes for spiked soil samples were 80.40‐119.6% with relative standard deviations less than 14.4%. The fiber was reused over 100 times without a significant loss of extraction efficiency.  相似文献   

12.
For the first time, Vacuum Assisted Headspace Solid Phase Microextraction (Vac-HSSPME) is used for the recovery of polycyclic aromatic hydrocarbons (PAHs) from solid matrices. The procedure was investigated both theoretically and experimentally. According to the theory, reducing the total pressure increases the vapor flux of chemicals at the soil surface, and hence improves HSSPME extraction kinetics. Vac-HSSPME sampling could be further enhanced by adding water as a modifier and creating a slurry mixture. For these soil-water mixtures, reduced pressure conditions may increase the volatilization rates of compounds with a low KH present in the aqueous phase of the slurry mixture and result in a faster HSSPME extraction process. Nevertheless, analyte desorption from soil to water may become a rate-limiting step when significant depletion of the aqueous analyte concentration takes place during Vac-HSSPME. Sand samples spiked with PAHs were used as simple solid matrices and the effect of different experimental parameters was investigated (extraction temperature, modifiers and extraction time). Vac-HSSPME sampling of dry spiked sand samples provided the first experimental evidence of the positive combined effect of reduced pressure and temperature on HSSPME. Although adding 2 mL of water as a modifier improved Vac-HSSPME, humidity decreased the amount of naphthalene extracted at equilibrium as well as impaired extraction of all analytes at elevated sampling temperatures. Within short HSSPME sampling times and under mild sampling temperatures, Vac-HSSPME yielded linear calibration curves in the range of 1–400 ng g−1 and, with the exception of fluorene, regression coefficients were found higher than 0.99. The limits of detection for spiked sand samples ranged from 0.003 to 0.233 ng g−1 and repeatability from 4.3 to 10 %. Finally, the amount of PAHs extracted from spiked soil samples was smaller compared to spiked sand samples, confirming that soil could bind target analytes more strongly and thus decrease the readily available fraction of target analytes.  相似文献   

13.
Nano‐molybdenum trioxide was prepared from nano‐molybdenum disulfide by simple firing in muffle furnace. Nano‐molybdenum trioxide was used as the extraction coating on the stainless steel wire. Four wires were filled in a polyetheretherketone tube to get an extraction tube. The tube was connected to the six‐port valve of a high performance liquid chromatograph, and the online analysis system was constructed. Extraction selectivity of the tube for different types of compounds, including polycyclic aromatic hydrocarbons, plasticizers, estrogens, anilines and neonicotinoids, was studied. Good enrichment ability for polycyclic aromatic hydrocarbons, but the extraction efficiency of others was not satisfactory. Using eight polycyclic aromatic hydrocarbons as the targets, an analytical method was established after optimizing main factors such as sampling volume, sampling rate, methanol content, and desorption time. The established method exhibited wide linear range to 0.016–20.00 μg/L and low limits of detection to 0.005 μg/L, and the enrichment factors can be up to 2443. The method was applied to the detection of trace polycyclic aromatic hydrocarbons in tap water and river water, and a good recovery was obtained. The tube showed good durability and chemical stability, and it still remained good extraction effect after more than 140 run.  相似文献   

14.
A bonding method was developed for coating molybdenum oxides onto a steel wire substrate, which was used as a solid‐phase microextraction fiber, was coupled with gas chromatography. Based on the characterization, it is found that the as‐prepared molybdenum oxides material contained a nanobelt structure with a uniform size and good dispersibility. In addition, there were a large number of small protrusions on the surface of the nanobelts. These characteristics provided a large specific surface area for extraction. Molybdenum oxides exhibited a high extraction selectivity for polycyclic aromatic hydrocarbons owing to its moderate coordination. After the optimization of the factors, method detection limits of < 1.25 μg/L were achieved, and the calibration curves were linear within the range of 2–600 μg/L. In addition, repeatability was demonstrated, and the relative standard deviation < 6.4%. The molybdenum oxides coating had a high scratch resistance, which could effectively prevent coating wear and failure. Combined with the high thermal and chemical stability, the service life of the coating was improved and could be used 150 times without a significant reduction in the extraction performance. Finally, the as‐prepared fiber had a comparable extraction capacity and higher partition coefficients that those of commercial polyacrylate fibers.  相似文献   

15.
A novel palladium solid‐phase microextraction coating was fabricated on a stainless‐steel wire by a simple in situ oxidation–reduction process. The palladium coating exhibited a rough microscaled surface and its thickness was about 2 μm. Preparation conditions (reaction time and concentration of palladium chloride and hydrochloric acid) were optimized in detail to achieve sufficient extraction efficiency. Extraction properties of the fiber were investigated by direct immersion solid‐phase microextraction of several polycyclic aromatic hydrocarbons and phthalate esters in aqueous samples. The extracted analytes were transferred into a gas chromatography system by thermal desorption. The effect of extraction and desorption conditions on extraction efficiency were investigated. Under the optimum conditions, good linearity was obtained and correlation coefficients between 0.9908 and 0.9990 were obtained. Limits of detection were 0.05–0.10 μg/L for polycyclic aromatic hydrocarbons and 0.3 μg/L for phthalate esters. Their recoveries for real aqueous samples were in the range from 97.1 to 121% and from 89.1 to 108%, respectively. The intra‐ and interday tests were also investigated with three different addition levels, and satisfactory results were also obtained.  相似文献   

16.
A novel, low‐cost and effective in‐needle solid‐phase microextraction device was developed for the enrichment of trace polycyclic aromatic hydrocarbons in water samples. The in‐needle solid‐phase microextraction device could be easily assembled by inserting hydrofluoric acid‐etched wires, which were used as adsorbent, into a 22‐gauge needle tube within spring supporters. Compared with the commercial solid‐phase microextraction fiber, the developed device has higher efficiency for the extraction of polycyclic aromatic hydrocarbons with four to six rings from water samples using the optimized extraction conditions. With gas chromatography equipped with a flame ionization detector, the limits of detection for the polycyclic aromatic hydrocarbons with four to six rings ranged from 0.0020 to 0.0067 ng/mL. The relative standard deviations for one needle and needle‐to‐needle extractions were in the range of 5.2–9.9% (n = 5) and 3.4–12.3% (n = 5), respectively. The spiked recoveries of the polycyclic aromatic hydrocarbons in tap water samples ranged from 73.2 to 95.4%. This in‐needle solid‐phase microextraction device could be a good field sampler because of the low sample loss over a long storage time.  相似文献   

17.
A mesoporous silica was functionalized by carbon nanotubes to enhance the extraction performance. The mesoporous material was coated on stainless steel wires, and three wires were inserted inside of a polyetheretherketone tube for in‐tube solid‐phase microextraction. The tube was coupled to high‐performance liquid chromatography with diode array detection to obtain online analytical system, then its extraction performance was evaluated using eight polycyclic aromatic hydrocarbons as the targets. In order to good sensitivity and accuracy, four conditions were optimized such as sampling volume, sampling rate, methanol content in the sample, and desorption time. Under the optimum conditions, an online analytical method was established and exhibited low limits of detection from 0.005 to 0.050 µg/L, wide linear range of 0.016‐20.00 µg/L with acceptable correlation coefficients in 0.9921‐0.9999, as well as large enrichment factors in the range of 311‐2412. The method was successfully applied to determine trace polycyclic aromatic hydrocarbons in some real water samples including, two kinds of bottled water, tap water, and river water, a few polycyclic aromatic hydrocarbons were detected but none quantified in these samples.  相似文献   

18.
Cotton fiber is an environmentally friendly and natural material with a certain extraction capacity, while its enrichment ability is poor. In order to improve the extraction efficiency of cotton fibers, it was carbonized to form a layer of amorphous carbon as the sorbent by a simple carbonization method. Carbonized cotton fibers were filled into a polyetheretherketone tube for in‐tube solid‐phase microextraction. The carbonization time was investigated to obtain high extraction efficiency. Coupled to high‐performance liquid chromatography, the extraction tube was evaluated with polycyclic aromatic hydrocarbons, estrogens and phthalates, and it exhibited best extraction efficiency for polycyclic aromatic hydrocarbons. Under the optimum conditions, an online analysis method for several polycyclic aromatic hydrocarbons was established with large linear ranges (0.016–0.20 μg/L), low limits of detection (0.005–0.020 μg/L), and high enrichment factors (948–2874). Analysis method was successfully applied to the detection of targets in the real samples and shown satisfactory durability and chemical stability. Moreover, the relative recoveries ranged from 82 to 119.2%, which demonstrated the applicability of carbonized cotton fibers in sample preparation. Compared with other reported methods, the proposed method provided shorter extraction time, higher enrichment factors, comparable limits of detection, and recoveries.  相似文献   

19.
A novel microextraction method, ordered mesoporous carbon reinforced hollow fiber liquid‐phase microextraction coupled with high‐performance liquid chromatography and fluorescence detection, was developed for the determination of some organic pollutants in water samples. Four polycyclic aromatic hydrocarbons (fluorene, anthracene, fluoranthene, and pyrene) were selected to validate this new method. Main parameters that could influence the extraction efficiency such as extraction time, fiber length, stirring rate, the type of the extraction solvent, pH value, the concentration of ordered mesoporous carbon, and salt effect were optimized. Under the optimal extraction conditions, good linearity was observed in the range of 2–1000 ng/L, with the correlation coefficients of 0.9954–0.9986. The recoveries for the spiked samples were in the range of 88.96–100.17%. The limits of detection of the method were 0.4–4 ng/L. The relative standard deviations varied from 4.2–5.9%. The results demonstrated that the newly developed method was an efficient pretreatment and enrichment procedure for the determination of polycyclic aromatic hydrocarbons in environmental water samples.  相似文献   

20.
A novel chemically bonded graphene oxide/fused-silica fiber was prepared and applied in solid-phase microextraction of six polycyclic aromatic hydrocarbons from water samples coupled with gas chromatography. It exhibited high extraction efficiency and excellent stability. Effects of extraction time, extraction temperature, ionic strength, stirring rate and desorption conditions were investigated and optimized in our work. Detection limits to the six polycyclic aromatic hydrocarbons were less than 0.08 μg/L, and their calibration curves were all linear (R(2)≥0.9954) in the range from 0.05 to 200 μg/L. Single fiber repeatability and fiber-to-fiber reproducibility were less than 6.13 and 15.87%, respectively. This novel fiber was then utilized to analyze two real water samples from the Yellow River and local waterworks, and the recoveries of samples spiked at 1 and 10 μg/L ranged from 84.48 to 118.24%. Compared with other coating materials, this graphene oxide-coated fiber showed many advantages: wide linear range, low detection limit, and good stability in acid, alkali, organic solutions and at high temperature.  相似文献   