1.
正A new ionic liquid-based high-performance liquid chromatography stationary phase is reported.A derivative of N-methyl pyrrolidinium tetrafluoroborate was covalently immobilized on the surface of silica particles to prepare silica-based N-methyl pyrrolidinium tetrafluoroborate(SilprMP BF4)stationary phase.The obtained ionic liquid-modified silica was evaluated and confirmed by elemental analysis,infrared spectroscopy,and thermogravimetric analysis.A column was packed with the modified particles.The retention behavior of aromatic compounds,alkyl benzenes,and acidic and basic compounds on the SilprMP BF4 stationary phase was studied under reversed-phase liquid chromatography conditions.The effect of the eluent pH on the separation of the acidic and basic compounds was also studied.The new stationary phase involves multiple retention mechanisms,such as electrostatic,hydrophobic,ion-dipole,and anion-exchange interactions,which might lead to multipurpose separation media.  相似文献   

2.
The silica-based stationary phases with favorable physical characteristics are the most popular in liquid chromatography. However, there are several problems with silica-based materials: severe peak tailing in the chromatography of basic compounds, non-reproducibility for the same chemistry columns, and limited pH stability. Ionic liquids (ILs) as mobile phase components can reduce peak tailing by masking residual free silanol groups. The chromatographic behavior of some alkaloids from different classes was studied on C18, phenyl, and pentafluorophenyl columns with different kinds and concentrations of ionic liquids as additives to aqueous mobile phases. Ionic liquids with different alkyl substituents on different cations or with different counterions as eluent additives were investigated. The addition of ionic liquids has great effects on the separation of alkaloids: decrease in band tailing, increase in system efficiency, and improved resolution. The retention, separation selectivity, and sequence of alkaloid elution were different when using eluents containing various ILs. The increase of IL concentration caused an increase in silanol blocking, thus conducted to decrease the interaction between alkaloid cations and free silanol groups, and caused a decrease of alkaloids retention, improvement of peak symmetry, and increase of theoretical plate number in most cases. The effect of ILs on stationary phases with different properties was also examined. The different properties of stationary phases resulted in differences in analyte retention, separation selectivity, peak shape, and system efficiency. The best shape of peaks and the highest theoretical plate number for most investigated alkaloids in mobile phases containing IL was obtained on pentafluorophenyl (PFP) phase.  相似文献   

3.
《Analytica chimica acta》2005,547(2):172-178
A suppression of silanophilic interactions by the selected ionic liquids added to the mobile phase in thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC) is reported. Acetonitrile was used as the eluent, alone or with various concentrations of water and phosphoric buffer pH 3. Selectivity of the normal (NP) and the reversed (RP) stationary phase material was examined using a series of proton-acceptor basic drugs analytes. The ionic liquids studied appeared to significantly affect analyte retention in NP-TLC, RP-TLC and RP-HPLC systems tested. Consequently, the increased separation selectivity was attained. Due to ionic liquid additives to eluent even analytes could be chromatographed, which were not eluted from the silica-based stationary phase materials with 100% of acetonitrile in the mobile phase. Addition of ionic liquid already in very small concentration (0.5%, v/v) could reduce the amount of acetonitrile used during the optimization of basic analytes separations in TLC and HPLC systems. Moreover, the influence of temperature on the separation of basic analytes was demonstrated and considered in practical HPLC method development.  相似文献   

4.
Hydrophilic interaction chromatography (HILIC) is valuable alternative to reversed-phase liquid chromatography separations of polar, weakly acidic or basic samples. In principle, this separation mode can be characterized as normal-phase chromatography on polar columns in aqueous-organic mobile phases rich in organic solvents (usually acetonitrile). Highly organic HILIC mobile phases usually enhance ionization in the electrospray ion source of a mass spectrometer, in comparison to mobile phases with higher concentrations of water generally used in reversed-phase (RP) LC separations of polar or ionic compounds, which is another reason for increasing popularity of this technique. Various columns can be used in the HILIC mode for separations of peptides, proteins, oligosaccharides, drugs, metabolites and various natural compounds: bare silica gel, silica-based amino-, amido-, cyano-, carbamate-, diol-, polyol-, zwitterionic sulfobetaine, or poly(2-sulphoethyl aspartamide) and other polar stationary phases chemically bonded on silica gel support, but also ion exchangers or zwitterionic materials showing combined HILIC-ion interaction retention mechanism. Some stationary phases are designed to enhance the mixed-mode retention character. Many polar columns show some contributions of reversed phase (hydrophobic) separation mechanism, depending on the composition of the mobile phase, which can be tuned to suit specific separation problems. Because the separation selectivity in the HILIC mode is complementary to that in reversed-phase and other modes, combinations of the HILIC, RP and other systems are attractive for two-dimensional applications. This review deals with recent advances in the development of HILIC phase separation systems with special attention to the properties of stationary phases. The effects of the mobile phase, of sample structure and of temperature on separation are addressed, too.  相似文献   

5.
The effects of temperature and mobile phase on LC chromatographic separation of phenolic antioxidants on zirconia-based columns were investigated. Unlike silica-based materials, zirconia columns show excellent thermal stability over a wide range of temperatures and enable high-temperature separations. Enthalpic and entropic contributions to the retention of phenolic compounds on ZR-Carbon and ZR-Carbon C18 columns were determined from retention versus temperature plots in order to elucidate the retention mechanism of sample compounds over the temperature range up to 14 degrees C. High-temperature liquid chromatography on ZR-Carbon columns was used for comprehensive LC x LC two-dimensional separation systems based on the different selectivity of a Zorbax SB micro-column used in the first dimension and a ZR-Carbon column used in the second dimension. Two-dimensional LC x LC systems employing a setup with two alternately operated parallel ZR-Carbon columns in the second dimension were used for the analysis of phenolic antioxidants in beer and wine samples.  相似文献   

6.
The use of silica columns together with non-aqueous ionic eluents provides a stable yet flexible system for the high-performance liquid chromatographic analysis of basic drugs. At constant ionic strength, eluent pH influences retention via ionisation of surface silanols and protonation of basic analytes, pKa values indicating the pH of maximum retention. At constant pH, retention is proportional to the reciprocal of the eluent ionic strength for fully protonated analytes and quaternary ammonium compounds. The addition of water up to 10% (v/v) has little effect on retention if the protonation of the analytes is unaffected. Thus, it is likely that retention is mediated primarily via cation exchange with surface silanols. However, additional factors must play a part with compounds such as morphine which give tailing peaks at acidic or neutral eluent pHs.  相似文献   

7.
Song  Chunying  Yu  Dongping  Jin  Gaowa  Zhou  Yongzheng  Han  Ziwei  Zhou  Han  Huo  Liduo  Liu  Lijie  Guo  Zhimou  Liang  Xinmiao 《Chromatographia》2022,85(5):447-454

Fluorinated stationary phases provide unique separation effect on basic compounds, due to the fluorine atoms, and pentafluorophenyl stationary phases (PFPs) are the most widely used. Considering that some fluoroalkyls have higher fluorine contents than PFPs do, it is speculated that fluoroalkyl stationary phases should have potential new applications. Herein, we synthesized a silica-based stationary phase bonding perfluoroctyl (FC8) proved by characterization through elemental analysis and solid-state 13C cross-polarization/magic-anglespinning nuclear magnetic resonance. The chromatographic behavior of the stationary phase was evaluated with test compounds. In addition, to further study the applicability of FC8 materials, Corydalis decumbens (Thunb.) Pers. fraction, considered as a challenging medicine on reversed-phase chromatography columns, was chosen as a test sample. Results demonstrated that the FC8 stationary phase had better and more satisfactory separation performance than the PFP stationary phase on basic compounds.

  相似文献   

8.
The reversed-phase liquid chromatographic analysis of basic pharmaceuticals can be problematic. Both the properties of the eluent and the stationary phase can influence the chromatographic performance. Therefore selection of suitable experimental conditions for the analysis of basic compounds can be difficult. This paper shows that the organic modifier and the nature of the buffer influence the eluent properties. Moreover, the nature and amount of modifier also influence the basicity of the analytes. Investigations showed that the nature of the buffer can have a significant influence on retention and peak shape of basic compounds. Test procedures using basic analytes as test probes provided relevant information with respect to selecting columns to analyse basic pharmaceutical compounds. Test procedures using compounds like aniline, phenol and benzene were found to be less suitable.  相似文献   

9.
Summary The chromatographic properties of an alkylphosphonate-modified magnesia-zirconia composite stationary phase have been investigated by reversed-phase high-performance liquid chromatography with basic compounds as probes. The influence of organic modifier composition and mobile phase pH was studied. The new stationary phase, similar to a silica-based reversed-phase stationary phase, has hydrophobic properties, but greater pH stability. Use of the phase results in more symmetric peaks for basic compounds. A possible mechanism of retention of basic solutes on the new stationary phase is discussed. The chromatographic behavior of the basic solutes depends mainly on hydrophobic interactions between the solutes and the hydrophobic moiety of the stationary phase. Br?nsted acidic and basic sites on the surface of the new stationary phase play an important role in the retention of ionized solutes by ion-exchange interaction. Promising separations of some basic compounds have been achieved by use of methanolic TRIS buffer, pH 10.0, as the mobile phase.  相似文献   

10.
Retention properties of 79 fungal metabolites (including neutral, acidic, basic, and amphoteric compounds) were evaluated on distinct mixed-mode reversed-phase/weak anion exchange (RP/WAX)-type stationary phases by liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS) in gradient as well as in isocratic elution mode. The RP/WAX separation materials were prepared by functionalising thiol-modified silica with N-(10-undecenoyl)-3-aminoquinuclidine and N-(10-undecenoyl)-3-alpha-aminotropane, respectively. To evaluate complementarity in chromatographic selectivity the physico-chemically heterogeneous solute set was analysed also on a RP phase (C(18)), an amino-type WAX phase, and a commercially available RP/WAX-like mixed-mode phase. Analytes may interact with the RP/WAX ligands via (attractive/repulsive) ionic, RP-like hydrophobic, as well as hydrophilic (HILIC) retention mechanisms. Individual interactive increments were found to be basically controlled by the nature and amount of organic modifier, pH value of eluent, and ionic strength of buffer additives. It could be demonstrated that RP/WAX columns offer the potential to separate compounds by exploiting a combination of various chromatographic interaction modes, which is not accessible with conventional RP and WAX columns. Such multi-modal properties increase both versatility and degrees of freedom for adjustment of chromatographic selectivity. For example, highly polar mycotoxins such as moniliformin were well retained on RP/WAX-type phases without compromising RP-selectivity for neutral (e.g. aflatoxins) and most basic solutes (e.g. epimer separation of ergot alkaloids) under fully MS-compatible conditions like a hydro-organic eluent with acetonitrile as organic modifier and an acetic acid/ammonium acetate buffer. Flexibility of the employed mixed-mode separation materials may be of value particularly for LC-ESI-MS/MS-based bioanalytics involving analytes with widely varying physico-chemical properties or applications prone to matrix effects.  相似文献   

11.
This paper describes the characterisation of reversed-phase liquid chromatography (RPLC) columns using thermodynamic measurements. Retention versus 1/T data were used to construct Van't Hoff plots. The slope of these plots indicates the standard enthalpy of transfer of the analyte from the mobile to the stationary phase. The standard entropy can be calculated from the intercept. Van't Hoff plots were linear for the investigated RPLC columns, meaning that for basic analytes over the temperature range studied no changes in the retention mechanism occurred. Enthalpies and entropies of transfer of basic analytes from the mobile to the stationary phase revealed information about the types of interaction of protonated and neutral compounds with the stationary phases. However, a clear view using the present set of basic compounds on how these thermodynamic data may explain the observed substantial differences in peak symmetry cannot be given. It is considered that addition of N,N-dimethyloctylamine (DMOA) to the eluent will results in a dynamically coating of the stationary phase. Addition of DMOA to the eluent resulted for protonated basic compounds in a reduction of both enthalpy and entropy. In practice, with DMOA in the eluent symmetrical peaks were obtained. It is assumed that this is due to blocking residual silanols and/or ion exclusion effects.  相似文献   

12.
The type of the stationary phase for reversed-phase liquid chromatography significantly affects the sample elution. Hydrodynamic properties, efficiency and gradient elution of proteins were investigated on five commercial C18 columns with wide-pore totally porous particles, with superficially porous layer particles, non-porous particles and a silica-based monolithic bed. The efficiency in the terms of reduced plate height is higher for low-molecular ethylbenzene than for proteins, but depends on the character of the pores in the individual columns tested. The superficially porous Poroshell and the non-porous Micra columns provide the best efficiency for proteins at high mobile phase flow rates, probably because of similar pore architecture in the stationary phase. The Zorbax column with similar pore architecture as the Poroshell active layer, i.e. narrow pore distribution of wider pores shows better efficiency than the packed column with narrow pores and broad pore distribution. The monolithic column shows lower efficiency for proteins at high flow rates, but it performs better than the broad-pore distribution totally porous particulate columns. Different pore architecture affects also the retention and selectivity for proteins on the individual columns. The retention times on all columns can be predicted using the model for reversed-phase gradient elution developed originally for low-molecular compounds. Consideration of the limited pore volume accessible to the biopolymers has negligible effect on the prediction of retention on the columns packed with non-porous or superficially porous particles, but improves the accuracy of the predicted data for the totally porous columns with broad pore distribution.  相似文献   

13.
The general goal of this work is to investigate the precision of chromatographic data and to determine which properties of chromatographic columns influence this factor. Chromatographic data were acquired under five different sets of experimental conditions for 30 neutral, acidic and basic test compounds on columns packed with Vydac 218TP C18, a polymeric, wide-pore silica-based stationary phase. Five columns packed with samples from the same batch of this packing material were used to measure the column-to-column reproducibility and six columns packed with material from six different batches to measure the batch-to-batch reproducibility. The parameters studied were the retention time, the retention and separation factors, the hydrophobic and the steric selectivities, the column efficiency, and the tailing factor.  相似文献   

14.
The reproducibility of retention data and band profile characteristics was investigated for a series of columns packed with Luna C18 (2), a silica-based, reversed-phase adsorbent. High precision data were obtained and statistically compared among five columns from the same batch (column-to-column reproducibility) and nine columns from as many different batches (batch-to-batch reproducibility). These data were acquired under five different sets of chromatographic conditions, for a group of 30 neutral, acidic, and basic compounds selected as probes following an experimental protocol previously described. This work is part of a study on the precision of chromatographic analyses. Its purpose is to illustrate the contribution of the stationary phase reproducibility to this precision.  相似文献   

15.
The high-performance liquid chromatographic behavior of some basic drugs was studied on a n-octadecylphosphonic acid modified magnesia-zirconia (C18PZM) stationary phase. The effect of mobile phase variables such as methanol content, ionic strength, and pH on their chromatographic behavior was investigated. The retention mechanism of basic drugs on the stationary phase was elucidated. The results indicate that both hydrophobic and cation-exchange interactions contribute to solute retention under most chromatographic conditions. The inherent Br?nsted-acid sites and also the adsorbed Lewis base anionic buffer constituents on accessible ZM surface Lewis acid sites play a role in the retention of ionized solutes by cation-exchange interaction. However, especially at high mobile phase pH, the retention of basic drugs depends mainly on hydrophobic interactions between solutes and support. Separations of the basic drugs on the C18PZM phase by a predominantly reversed-phase retention mode were very promising. The mixed-mode retention feature on this phase, as a result of the adsorbed Lewis base anionic buffer constituents acting as sites for cation-exchange, could also be very useful, e.g. for enhancing the chromatographic selectivity of such analytes. The C18PZM seems to be an excellent alternative to silica-based reversed-phase stationary phase for the separation of strongly basic solutes.  相似文献   

16.
The two major modes of retention of basic compounds in reversed-phase liquid chromatography on both octadecyl silane bonded silica-based (ODS) and polybutadiene coated zirconia (PBD-ZrO2) materials are hydrophobic and ion-exchange (Coulombic) interactions. Although the influence of reversed-phase and Coulombic interactions on the chromatography of organic cations is qualitatively well recognized, the quantitative relationship between hydrophobic and ion-exchange interactions remains unclear. In this work, the retention mechanisms on both of the above types of phases were probed by studying the retention of a homologous series of p-alkylbenzylamines as a function of the ammonium concentration in the eluent. The various columns tested were studied in terms of plots of retention factor vs. the inverse of the displacingcation concentration. The analysis of such plots as well as plots of log k' vs. number of methylene groups in the solutes and plots of log k' vs. log[NH4+] clearly shows that at least two types of sites--a pure reversed-phase site and a "hydrophobically-assisted ion-exchange site" similar to the type of site described by Neue [J. Chromatogr. A 925 (2001) 49] are needed to explain the observations. In addition, we have found a quantitative measure of the relative amount of reversed-phase and ion-exchange interaction on a given solute has on a given stationary phase which allows unambiguous classification of columns. It is now clear that ion-exchange contributions to retention on PBD-ZrO2, sometimes exceeding 90%, are even more important than previously thought and relative to hydrophobic interaction much more significant on PBD-ZrO2 than on ODS type-B silicas.  相似文献   

17.
L. Szepesy  G. Rippel 《Chromatographia》1992,34(5-8):391-397
Summary Retention and selectivity in hydrophobic interaction chromatography (HIC) depend both on the type of stationary phase and on the mobile phase. In the last few years various high performance packing materials and columns have been introduced for HIC resulting in a range of different retentions and selectivity. We have investigated the effect of the stationary phase on the retention of various proteins. The retention of some solutes of different hydrophobicities were measured on three commercial HIC columns (TSK-Phenyl, Synchropack-Propyl, CAA-HIC) under isocratic conditions using water-methanol mixtures as eluent. The log kw values determined according to the literature were devalues determined according to the literature were dependent on the type and structure of the stationary phase and indicated a much less hydrophobic character for these columns than that obtained for reversed phase columns. Gradient separations were then carried out on a standard protein mixture using ammonium sulfate and sodium citrate to change the gradient time. In order to compare the effect of the stationary phase and the two salts investigated apparent capacity factors (kg) were determined and plotted against the gradient time obtained for the three columns in the two eluent system. It was shown that the type of stationary phase had a significant effect on the retention of proteins. In addition, the effect of the mobile phase composition, i.e. salt type, was considerably different on the various stationary phases. In order to exploit the potential of HIC to modulate selectivity for the separation of proteins, the combined effect of the stationary phase and the type of salt should be taken into account.Dedicated to Professor Leslie S. Ettre on the occasion of his 70th birthday.  相似文献   

18.
The retention and selectivity of the chromatographic separation of basic (cationic) analytes on a polybutadiene-coated zirconia (PBD-ZrO2) stationary phase have been studied in greater detail than in previous studies. These separations are strongly influenced by the chemistry of the accessible surface of zirconia. In the presence of buffers which contain hard Lewis bases (e.g., phosphate, fluoride, carboxylic acids) zirconia's surface becomes negatively charged due to adsorption of the buffer anion at the hard Lewis acid sites. Consequently, under most conditions (e.g., neutral pH), cationic analytes undergo both hydrophobic and cation-exchange interactions. This mixed-mode retention process generally leads to greater retention factors for cations relative to those on silica-based reversed phases despite the lower surface areas of the zirconia phase, but, more importantly, adsorption of hard Lewis bases can be used to control the chromatographic selectivity for cationic analytes on these zirconia-based stationary phases. In contrast to our prior work, here we show that when mixed-mode retention takes place, both retention and selectivity are easily adjusted by changing the type of hard Lewis base buffer anion, the type of buffer counter-ion (e.g., sodium, potassium, ammonium), the pH, and the ionic strength of the eluent as well as the type and amount of organic modifier.  相似文献   

19.
The effect of ionic composition of mobile phase on retention and chromatographic separation of optical isomers of several derivatives of 2-arylpropanoic acid on a chiral stationary phase Diaspher-Chiralsel-E with a grafted eremomycin antibiotic was studied. As was shown, the mechanism of retention differs from that for hydrophobic reverse-phase adsorbents, as it involves a substantial ion-exchange component that determines the nonmonotonic dependence of the retention factor and the enantioselectivity on eluent pH. The effect of the concentration of buffer salt in the eluent on the chromatography of this class of compounds is discussed.  相似文献   

20.
A monolithic silica stationary phase functionalized with an enantioselective strong cation exchanger based on an aminosulfonic acid derivative was used for chiral separations of basic test solutes by nonaqueous CEC and capillary LC. The effects of the applied electric field as well as the ionic strength in the eluent on electrokinetic and chromatographic contributions to the overall separation performance in the electrically driven mode were investigated. Hence, under the utilized experimental conditions, i. e., at an electric field strength in the range of approximately 120-720 V/cm (applied voltages 4-24 kV) and an ionic strength of the counterion between 5 and 25 mM (at constant acid-to-base, i. e., co- to counterion ratio of 2:1), no deviations from the expected linearity of the EOF were observed. This led to the conclusion that an occurrence of the so-called electrokinetic effects of the second kind resulting from electric double layer overlap inside the mesopores of the monolithic stationary phase and concentration polarization phenomena were largely negligible. Additional support to this conclusion was inferred from the observed independence of CEC retention factors on the electric field strength across the investigated ionic strength range of the BGE. As a consequence, a simple framework allowing for calculation of the CEC mobilities from the individual separation contributions, viz. electroosmotic and electrophoretic mobilities as well as retention factors, could be applied to model CEC migration. There was a reasonable agreement between calculated and experimental CEC mobility data with deviations typically below 5%. The deconvolution of the individual contributions to CEC migration and separation is of particular value for the understanding of the separation processes in which electrophoretic migration of ionic sample constituents plays a significant role like in ion-exchange CEC and may aid the optimization procedure of the BGE and other experimental conditions such as the optimization of the surface chemistry of the stationary phase. In combination with the remarkable column performance evident from the low theoretical plate heights observed under CEC conditions for all test solutes (3.5-7.5 microm in the flow rate range of 0.4-1.2 mm/s, corresponding to (130,000-300,000 plates per meter), the presented framework provides an attractive tool as the basis for the assessment of chromatographic selectivities in a miniaturized CEC screening of new selectors and chiral stationary phases (CSPs), respectively, from experimental CEC data and known CE mobilities.  相似文献   