首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Dynamic nuclear polarization of metabolically active compounds labeled with (13)C has been introduced as a means for imaging metabolic processes in vivo. To differentiate between the injected compound and the various metabolic products, an imaging technique capable of separating the different chemical-shift species must be used. In this paper, the design and testing of a pulse sequence for rapid magnetic resonance spectroscopic imaging (MRSI) of hyperpolarized (13)C is presented. The pulse sequence consists of a small-tip excitation followed by a double spin echo using adiabatic refocusing pulses and a "flyback" echo-planar readout gradient. Key elements of the sequence are insensitivity to calibration of the transmit gain, the formation of a spin echo giving high-quality spectral information, and a small effective tip angle that preserves the magnetization for a sufficient duration. Experiments in vivo showed three-dimensional coverage with excellent spectral quality and SNR.  相似文献   

2.
There is a continuing need for improved RF pulses that achieve proper refocusing in the context of ultra-high field (≥ 7 T) human MRI. Simple block or sinc pulses are highly susceptible to RF field inhomogeneities, and adiabatic pulses are generally considered too SAR intensive for practical use at 7 T. The performance of the array of pulses falling between these extremes, however, has not been systematically evaluated. The aim of this work was to compare the performances of 21 non-selective refocusing pulses spanning a range of durations and SAR levels. The evaluation was based upon simulations and both phantom and in vivo human brain experiments conducted at 7 T. Tested refocusing designs included block, composite block, BIR-4, hyperbolic secant, and numerically optimized composite waveforms. These pulses were divided into three SAR classes and two duration categories, and, based on signal gain in a 3-D spin echo sequence, practical recommendations on usage are made within each category. All evaluated pulses were found to produce greater volume-averaged signals relative to a 180° block pulse. Although signal gains often come with the price of increased SAR or duration, some pulses were found to result in significant signal enhancement while also adhering to practical constraints. This work demonstrates the signal gains and losses realizable with single-channel refocusing pulse designs and should assist in the selection of suitable refocusing pulses for practical 3-D spin-echo imaging at 7 T. It further establishes a reference against which future pulses and multi-channel designs can be compared.  相似文献   

3.
郑宏军  刘山亮  黎昕  徐静平 《物理学报》2007,56(4):2286-2292
采用分步傅里叶方法数值研究了初始线性啁啾和非线性啁啾双曲正割光脉冲在单模光纤反常色散区的线性传输特性,并与啁啾高斯脉冲的线性传输特性作了比较.给出了双曲正割光脉冲频谱宽度和时间带宽积随初始线性啁啾变化的表达式.结果表明,双曲正割脉冲在线性啁啾|C|>0.1时随传输距离的增加逐渐演化成近高斯型,在0≤|C|≤0.1时最后将演化为近双曲正割脉冲.|C|越小,脉冲时域波形越趋近双曲正割曲线.负啁啾对脉冲时域展宽的影响比正啁啾要大得多.当|C|≥0.5时,初始啁啾对双曲正割光脉冲展宽的影响比对高斯脉冲的影响更大.非线性啁啾双曲正割光脉冲在线性传输过程中会出现时域波形分裂现象,比具有相同啁啾的高斯脉冲时域波形分裂严重. 关键词: 频率啁啾 双曲正割光脉冲 线性传输 时域波形分裂  相似文献   

4.
An algorithm to calculate NMR signals of a multi-echo pulse sequence with arbitrary position dependent B0 and B1 fields taking into account relaxation and spin-diffusion is presented. The multi-echo pulse sequence consists of an initial RF pulse ("90 degrees " RF pulse) and a series of L refocusing RF pulses with arbitrary phases and flip-angles. The calculation is exact and takes into account all the magnetization pathways that contribute to the signal on a predefined spatial grid. The theoretical prediction is verified experimentally using a high field NMR microscopy system. The algorithm was implemented in a simulation program in order to optimize the design of an inside-out MR intra-vascular catheter that is used for characterization of vessel wall tissue. Measured data obtained with the catheter are in good agreement with the theoretical prediction of the simulation.  相似文献   

5.
Resolved NMR spectra from samples in inhomogeneous B0 and B1 fields can be obtained with the so-called "ex situ" methodology, employing a train of composite or adiabatic z-rotation RF pulses to periodically refocus the inhomogeneous broadening during the detection of the time-domain signal. Earlier schemes relied on a linear correlation between the inhomogeneous B0 and B1 fields. Here the pulse length, bandwidth, and amplitude of the adiabatic pulses of the hyperbolic secant type are adjusted to improve the refocusing for a setup with non-linear correlation. The field correlation is measured using a two-dimensional nutation experiment augmented with a third dimension with varying RF carrier frequency accounting for off-resonance effects. The pulse optimization is performed with a computer algorithm using the experimentally determined field correlation and a standard adiabatic z-rotation pulse as a starting point for the iterative optimization procedure. The shape of the z-rotation RF pulse is manipulated to provide refocusing for the conditions given by the sample-, magnet-, and RF-coil geometry.  相似文献   

6.
Functional magnetic resonance imaging favors the use of multi-slice gradient-recalled echo-planar imaging due to its short image acquisition times, whole brain coverage and sensitivity to BOLD contrast. However, despite its advantages, gradient-recalled echo-planar imaging also is sensitive to static magnetic field gradients arising primarily from air-tissue interfaces. This can lead to image artifacts such as voxel shifts and complete signal loss. A method to recover signal loss by adjusting the refocusing gradient amplitude in the slice-select direction, preferably axially, is proposed. This method is implemented as an automated computer algorithm that partitions echo-planar images into regions of recoverable signal intensities using a histogram analysis and determines each region's proper refocusing gradient amplitude. As an example, different refocusing gradient amplitudes are interleaved in a fMRI acquisition to maximize the signal to noise ratio and obtain functional activation in normal and dropout regions. The effectiveness of this method is demonstrated by recovering signal voids in the orbitofrontal cortex, parahippocampal/amygdala region, and inferior visual association cortex near the cerebellum.  相似文献   

7.
A fast method for quantitative imaging of T2 and displacement (flow and diffusion) is presented. The pulse sequence combines multi-PGSE NMR with multi-echo acquisition and compensates for flow effects in the read gradient and diffusion during multi-echo trains. The impact of the gradient pulses in a multi-echo train on the signal phase and amplitude is discussed. It is shown that separate T2 and displacement images with microscopic resolution can be obtained within minutes. The capability for 3D flow imaging is demonstrated. The sequence is then used to investigate forced detachment of a biofilm in a tube.  相似文献   

8.
The Look–Locker echo-planar imaging (LL-EPI) sequence has been numerically optimized in terms of the signal-to-noise ratio in the measured value of T1, for both single-shot (repetition time (TR) = ∞), and dynamically repeated T1 measurements. The sequence is optimized for the normal biologic range of T1 (0.2 s to 2.0 s) and for a range of sequence parameters found on most magnetic resonance (MR) scanners. Both linearly and geometrically spaced magnetization sample pulse intervals were considered. For single-shot measurements, the sequence with 24 linearly spaced sample pulses, an inversion time of 0.01 s, an inter-sample pulse delay of 0.10 s, and a sample radiofrequency (RF) pulse flip angle of 25o was found to be optimum. When the number of sample pulses was limited due to hardware limitations, different pulse sequence parameters were indicated. The optimization procedures used are appropriate for any single-shot T1 mapping sequence variant and for any rapid T1 mapping application. The use of an optimized Look–Locker echo-planar imaging sequence is demonstrated by an example of dynamic contrast-enhanced scanning in the brain using fast T1 mapping.  相似文献   

9.
Single-shot line scan imaging using stimulated echoes   总被引:2,自引:0,他引:2  
A new high-speed MRI method is described for single-shot line scan imaging (LSI) based on stimulated echoes (STE). To allow for multislice imaging, the technique comprises a series of slice-selective preparation pulses (each corresponding to the first RF pulse of a STE sequence), a slab-selective refocusing pulse (second RF pulse), and multiple line-selective read pulses (third RF pulses). An alternative version employs packages of two slice-selective pulses followed by multiple line-selective read pulses. Experimental applications deal with human brain imaging on a clinical MRI system at 2.0 T. The technique offers user-selectable trade-offs between volume coverage (1-15 sections) and in-plane spatial resolution (1-5 mm linear pixel dimension) within total acquisition times of less than 500 ms. Although LSI yields a lower signal-to-noise ratio than Fourier imaging, single-shot LSI with STEs is free from resonance offset effects (e.g., magnetic field inhomogeneities and susceptibility differences) that are typical for echo-planar imaging. Moreover, the technique exhibits considerable robustness against motion and provides access to arbitrary fields-of-view, i.e., localized imaging of inner volumes without aliasing artifacts due to phase wrapping.  相似文献   

10.
杨振峰  杨振军  张书敏 《光子学报》2008,37(9):1722-1725
利用理论推导和数值模拟方法,给出了超短双曲正割脉冲较为严格的均方根脉冲宽度与通常使用的半高全宽脉冲宽度的解析表达式,并对两种脉冲宽度进行了比较.研究结果表明,对于亚周期(半高全宽脉冲宽度小于一个光学振荡周期)双曲正割脉冲,均方根脉冲宽度与半高全宽脉冲宽度有较大的差异,并且绝对相位对均方根脉冲宽度的影响很大.所以描述亚周期双曲正割脉冲时应该使用更加严格的均方根脉冲宽度.  相似文献   

11.
Diffusion magnetic resonance imaging (MRI) was performed with a high-resolution segmented echo-planar imaging technique, which provided images with substantially less susceptibility artifacts than images obtained with single-shot echo-planar imaging (EPI). Diffusion imaging performed with any multishot pulse sequence is inherently sensitive to motion artifacts and in order to reduce motion artifacts, the presented method utilizes navigator echo phase corrections, performed after a one-dimensional Fourier transform along the frequency-encoding direction. Navigator echo phases were fitted to a straight line prior to phase correction to avoid errors from internal motion. In vivo imaging was performed using electro cardiographic (ECG) triggering. Apparent diffusion coefficient (ADC) maps were calculated on a pixel-by-pixel basis using up to seven diffusion sensitivities, ranging from b = 0 to 1129 x 10(6) s/m(2).  相似文献   

12.
A study was undertaken to assess the use of excitation flip angles greater than 90° for T1 weighted spin-echo (SE) imaging with a single 180° refocusing pulse and short TR values. Theoretical predictions of signal intensity for SE images with excitation pulse angles of 90–180° were calculated based on the Bloch equations and then measured experimentally from MR images of MnCl2 phantoms of various concentrations. Liver signal-to-noise ratios (SNR) and liver-spleen contrast-to-noise ratios (CNR) were measured from breathhold MR images of the upper abdomen in 16 patients using 90 and 110° excitation flip angles. The theoretical predictions showed significant improvements in SNR with excitation flip angles >90°, which were more pronounced at small TR values. The phantom studies showed reasonably good agreement with the theoretical predictions in correlating the excitation pulse angle with signal intensity. In the human imaging studies, the 110° excitation pulse angle resulted in a 7.4% (p < .01) increase in liver SNR and an 8.2% (p = .2) increase in liver-spleen CNR compared to the 90° pulse angle at TR = 275 ms. Increased signal intensity resulting from the use of large flip angle excitation pulses with a single echo SE pulse sequence was predicted and confirmed experimentally in phantoms and humans.  相似文献   

13.
The generalized magic asymmetric gradient stimulated echo (generalized MAGSTE) sequence compensates background gradient cross-terms and can be adjusted to asymmetric timing boundary conditions which for instance are present in echo-planar MR imaging. However, its efficiency is not optimal because one of the two diffusion-weighting gradients applied in each interval usually must have a reduced amplitude to ensure the desired cross-term compensation. In this work, a modification of generalized MAGSTE is investigated where this gradient pulse is replaced by two gradient pulses with full amplitude but opposite polarities. It is shown that with these bipolar gradients (i) the sequence retains the cross-term compensation capability for an appropriate choice of the gradient pulse durations and (ii) the diffusion-weighting efficiency is improved, i.e. higher k and b values can be achieved without prolonging the echo time. These results are confirmed in MR imaging experiments on phantoms and in vivo in the human brain at 3 T using spin-echo and echo-planar MR imaging. In the examples shown, the b value could be increased between about 30% and 200% when using the bipolar gradient pulses. Thus, bipolar gradients may help to improve the applicability of the generalized MAGSTE sequence.  相似文献   

14.
INTRODUCTION: Image contrast between tissue types can be generated based on their T1/T2 ratio using spin-lock MRI techniques. An interesting application of such a concept would be to generate contrast in tissue with tissue relaxation times modified using exogenous contrast agents. An amplitude-modulated adiabatic waveform has been shown in the past to perform spin-lock MRI. However, implementation of this waveform may not prove to be efficient and practical in research or a clinical setup due to high radiofrequency power deposition. Recent advancement in software and hardware MR technology allows implementation of amplitude- and phase-modulated adiabatic waveforms on MR systems. The aim of this work was to explore role of adiabatic waveforms in performing rho imaging and demonstrate that amplitude- and phase-modulated waveforms [e.g., hyperbolic secant, B1 independent rotation-4 (BIR-4) waveforms] can be used to distinguish materials that differ in T1/T2 ratio. METHODS AND RESULTS: MR simulation was performed using computer routines implemented in MATLAB environment (Mathworks, Natick, MA). Modified Bloch equations with trapezoidal, hyperbolic secant and BIR-4 waveforms were used to perform MR simulation. Trapezoidal waveforms were only used for comparison to other waveforms. Gadolinium DTPA (Gad-DTPA) (T1/T2 approximately 1) and manganese chloride (MnCl(2)) (T1/T2 approximately 10) were used as examples of contrast agents due to their routine use in clinical and research setups and more importantly because they provide good examples of materials differing in T1/T2 ratios. Results of spin locking using trapezoidal waveform agree very well with the previously published results, thereby validating the computer routines used in this MR simulation. Plots of M(rho) (magnetization vector in rho domain) vs. offset frequency show distinct curves for these materials differing in T1/T2 for the three waveforms. BIR-4 waveform demonstrated a 40% difference in M(rho) ( approximately 150 Hz) for the materials. Rate of spin lock with hyperbolic secant waveform was rapid compared to other waveforms. DISCUSSION: MR simulation using contrast agents Gad-DTPA and MnCl(2) provided a useful way to demonstrate that amplitude- and phase-modulated adiabatic waveforms can be used to perform spin-lock imaging. Future work involves implementation of these waveforms on MR scanners and performing in vivo imaging to generate tissue contrast based on relaxation times ratio.  相似文献   

15.
The magic asymmetric gradient stimulated echo (MAGSTE) sequence developed to compensate background-gradient cross-terms in the preparation and readout interval independently, assumes identical lengths for the two gradient pulses applied in each interval. However, this approach is rather inefficient if some extra delay time is present in one half of an interval, e.g. as required for special RF excitations or spatial encoding prior to the stimulated echo in MR imaging. Therefore, a generalized version of the sequence is presented that considers different gradient pulse lengths within an interval. It is shown theoretically that (i) for any pulse lengths a "magic" amplitude ratio exists which ensures the desired cross-term compensation in each interval and that (ii) prolonging one of the gradients can deliver a considerably higher diffusion weighting efficiency. These results are confirmed in MR imaging experiments on phantoms and in vivo in the human brain at 3T using an echo-planar trajectory. In the examples shown, typically 10 times higher b values can be achieved or an echo time reduction with a 40% signal gain in brain white matter. Thus, in case of asymmetric timing requirements, the generalized MAGSTE sequence with different gradient pulse lengths may help to overcome signal-to-noise limitations in diffusion weighted MR.  相似文献   

16.
Slice-selective broadband refocusing pulses are of great interest in localized MR spectroscopy for improving spatial selectivity, reducing chemical-shift displacement errors, and reducing anomalous J modulation. In practice the bandwidth of RF pulses is limited by the maximum available B1 amplitude. The goal of the present work is to design slice-selective and broadband refocusing pulses which are tolerant against B1 deviations. Pulse design is performed by numerical optimization based on optimal control theory. A comprehensive study of different cost functions and their effect on the optimization is given. The optimized slice-selective broadband refocusing pulses are compared to conventional Shinnar-Le Roux (SLR), broadband SLR, and hyperbolic secant pulses. In simulations and experiments optimized pulses were shown to fulfill broadband slice specifications over a range of ±20% B1 scalings. Experimental validation showed a reduction of chemical-shift displacement error by a factor of 3 compared to conventional SLR pulses.  相似文献   

17.
SolitonTransmissionUsingActivelyMode-lockedFiberRingLaserat2.5GHzand5GHz¥ZHONGShan;LOUCaiyun;LIUJun;GAOYizhi;ZHOUBingkun(Dept...  相似文献   

18.
The objective of this study was to implement a clinically relevant multi-slice multi-echo imaging sequence in order to quantify multi-component T2 relaxation times for normal volunteers at both 1.5 and 3 T. Multi-echo data were fitted using a nonnegative least square algorithm. Twelve echo data with nonlinear echo sampling were acquired using a receive-only eight-channel phased array coil and volume head coil for phantoms and normal volunteers, and compared to 32-echo data with linear echo sampling. It was observed that the performance of the 180 degrees refocusing trains was more spatially uniform for the receive-only eight-channel phased array coil than for the head coil, particularly at 3 T. The phantom study showed that the estimated T2 relaxation times were accurate and reproducible for both single- and multi-slice acquisition from a commercial phantom with known T2 relaxation times. Short T2 components (T2 <50 ms) were mainly observed within the white matter for normal volunteers, and the fraction of short T2 water components (i.e., myelin water) was 7-12% of total water. It was observed that the calculated myelin water fraction map from the nonlinearly sampled 12-echo data was comparable with that from the linearly sampled 32-echo data. Quantification of T2 relaxation times from multi-slice images was accomplished with a clinically acceptable scan times (16 min) for normal volunteers by using a nonselective T2 prep imaging sequence. The use of the eight-channel head coil involved more accurate quantification of T2 relaxation times particularly when the number of echoes was limited.  相似文献   

19.
Ultra-high-field clinical MRI scanners (e.g., 7 T and above) are becoming increasingly prevalent and can potentially enhance diagnostic ability through higher contrast, resolution and/or sensitivity. Diffusion-weighted MRI is a highly valued component in today's radiological exam and may benefit from the enhanced signal-to-noise ratio provided by high field with the appropriate imaging strategy. The most common diffusion pulse sequence readout (echo-planar imaging (EPI)) has been widely employed for in vivo human 7 T diffusion tensor imaging (DTI). In this article, we present results of brain DTI at 7 T with two diffusion-weighted imaging pulse sequence readouts: echo-planar imaging (EPI-DTI) and turbo spin echo (TSE-DTI). Results indicate that analogous coverage, quality and resolution typical of lower field (2 mm) can be obtained by properly processed EPI-DTI at 7 T, and, with some reduction in efficiency and sharpness, TSE-DTI at 7 T. Furthermore, 7 T TSE-DTI shows promise in obtaining higher-resolution results in targeted acquisitions of specific brain areas.  相似文献   

20.
Gapped pulses for frequency-swept MRI   总被引:1,自引:0,他引:1  
A recently introduced method called SWIFT (SWeep Imaging with Fourier Transform) is a fundamentally different approach to MRI which is particularly well suited to imaging objects with extremely fast spin–spin relaxation rates. The method exploits a frequency-swept excitation pulse and virtually simultaneous signal acquisition in a time-shared mode. Correlation of the spin system response with the excitation pulse function is used to extract the signals of interest. With SWIFT, image quality is highly dependent on producing uniform and broadband spin excitation. These requirements are satisfied by using frequency-modulated pulses belonging to the hyperbolic secant family (HSn pulses). This article describes the experimental steps needed to properly implement HSn pulses in SWIFT. In addition, properties of HSn pulses in the rapid passage, linear region are investigated, followed by an analysis of the pulses after inserting the “gaps” needed for time-shared excitation and acquisition. Finally, compact expressions are presented to estimate the amplitude and flip angle of the HSn pulses, as well as the relative energy deposited by the SWIFT sequence.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号