首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Yu L  Li SF 《Electrophoresis》2005,26(22):4360-4367
There is a need to develop simple yet effective preconcentration methods to enhance concentration sensitivity for CE analysis of trace level analytes in real samples, particularly when commonly available but less sensitive detection methods, e.g., UV detection, are used. In this report, a hyphenated online preconcentration strategy combining dynamic pH junction with sweeping (i.e., dynamic pH junction-sweeping) was employed for the analysis of four toxic pyrrolizidine alkaloids (PAs) of senkirkine, senecionine, retrorsine, and seneciphylline in Chinese herbal medicine (Kuan donghua). Direct electrokinetically focusing of a large sample volume injection (up to 20% of capillary length) on the capillary was performed using the dynamic pH junction-sweeping method. A sample matrix consisting of 10 mM phosphate with 20% methanol at pH 4.0 and a BGE containing 20 mM borate, 30 mM SDS, and 20% methanol at pH 9.1 were utilized to realize dynamic pH junction-sweeping for PAs. This online preconcentration strategy resulted in sensitivity enhancement factors ranging from 23.8- to 90.0-fold for the four toxic PAs, giving an LOD as low as 30 ppb for the PAs. Critical factors such as sample matrix type, pH, and salt concentration were also examined to achieve higher sensitivity enhancement, shorter analysis time, and better resolution. The results indicate that the proposed dynamic pH junction-sweeping technique is a powerful alternative approach for identification and determination of trace levels of these toxic PAs and other hydrophobic, protonatable compounds in real samples.  相似文献   

2.
Summary Velocity-difference induced focusing (V-DIF) of analytes by a dynamic pH junction represents a simple yet effective on-line preconcentration method to improve concentration sensitivity in capillary electrophoresis (CE). Differences in buffer type, pH and conductivity between sample and background electrolyte (BGE) segments of the capillary are properties used to optimize purine focusing within a multi-section electrolyte system. This method permits the injection of large volumes of sample (up to 450 nL or about 18% of capillary length), resulting in over a 50-fold improvement in sensitivity with baseline resolution. The limit of detection (S/N=3) for xanthine is determined to less than 4.0×10−8 M under optimum conditions when using UV detection. Analysis of micromolar amounts of xanthine in pooled urine is also demonstrated without sample pretreatment. A dual mechanism involving dynamic pH and isotachophoretic modes is proposed to enhance analyte focusing performance when employing buffer pH junctions based on different types of electrolyte co-ions.  相似文献   

3.
Dynamic pH junction is an online focusing method in CE based on the electrophoretic mobility difference of analytes in the sample matrix and the background electrolyte. An advantage of this method over the conventional CE is that the sensitivity can be significantly improved. By injecting a long sample plug in the capillary and focusing the analytes at the pH boundary between the background electrolyte and sample matrix, the LOD can be improved by 10–100 folds. The dynamic pH junction method can be easily coupled with ESI‐MS. In this work, we used this method for the analysis of microcystins (MCs). The detection limits and dynamic ranges were studied. The separation was optimized by adjusting the injection time, and concentrations and pH values of the background electrolyte. The optimization of analyte focusing leads to enhanced detection response compared to conventional injections, achieving 200–400 fold higher averaged peak heights for four microcystin (MC) variants. More importantly, this method was successfully used for the quantitative analysis of microcystins (MCs) in crude algae samples from natural water bodies, making it promising for practical applications.  相似文献   

4.
Arnett SD  Lunte CE 《Electrophoresis》2003,24(11):1745-1752
Capillary electrophoresis has been widely used for the analysis of physiological samples such as plasma and microdialysate. However, sample destacking can occur during the analysis of these high-ionic strength samples, resulting in poor separation efficiency and reduced sensitivity. A technique termed pH-mediated stacking of anions (base stacking) has previously been developed to analyze microdialysate samples and achieve on-line preconcentration of analytes by following sample injection with an injection of sodium hydroxide. In this work, the mechanism of base stacking was investigated. Peak efficiency was shown to be a function of background electrolyte and sample ionic strength. Analytes representing several classes of compounds with a wide range of mobilities were used to study the effects of multiple parameters on sample stacking. The length of hydroxide injection required for stacking was shown to be dependent on analyte mobility and the type of amine background electrolyte used. Combinations of electrokinetic and hydrodynamic injections of sample and hydroxide were examined and it was concluded that although stacking could be achieved with several injection modes, electrokinetic injection of both sample and hydroxide was most effective for sample stacking. The mechanism of pH-mediated stacking for each of these modes is presented.  相似文献   

5.
Li P  Duan J  Hu B 《Electrophoresis》2008,29(14):3081-3089
A hollow fiber-based liquid-liquid-liquid microextraction (HF-LLLME) combined with on-line large-volume sample stacking (LVSS) has been developed for the speciation of organomercury in biological samples by CE with UV detection. Separation was achieved in less than 11 min with an electrolyte consisting of 35 mM sodium tetraborate at pH 9.1. In LVSS, a reverse electrode polarity-stacking mode (REPSM) was applied as on-line preconcentration strategy. In HF-LLLME, the analytes were extracted from 12 mL volume of sample solution (pH adjusted to 3.0) into bromobenzene impregnated in the pores of the hollow fiber, and into an acceptor solution of L-cysteine (15 microL, 0.02% w/v) inside the hollow fiber. Under the optimized conditions, concentration factors of 2610-4580 were achieved and LODs in the range of 0.03-0.14 microg/L were feasible. The linearity was found to be over two orders of magnitude with correlation coefficient of 0.9991-0.9996. The developed method has been validated using a certified reference material (DORM-2, dogfish muscle), and the determined values coincided very well with the certified values. The method was also applied to the speciation of organomercury in three kinds of fish samples and human hair samples.  相似文献   

6.
毛细管电泳作为一种快速、高效的分离分析技术,已应用于许多领域.该文就近年来毛细管电泳中的样品堆积、扫集、等速电泳、动态pH连接及固相萃取等样品富集方法的原理进行了简单介绍,并对它们的应用进行了总结和评述,引用文献161篇.  相似文献   

7.
The use of concentrated samples is usually avoided during conventional separations since utilization of concentrated samples normally compromises the quality of separation. However, in case of the detection of low‐abundance components, highly concentrated samples are necessary, which leads to an extremely high concentration for high‐abundant components. This will make the separation difficult due to the serious longitudinal dispersion. Here, we developed a method to separate high concentration of components based on the modified capillary electrophoresis. The mechanism involves concentrated sample stretched into a wider zone in the higher electric field strength; the sample zone is fractionated into thin sections via a cutting effect; these thin sections are then separated. Based on this mechanism, we examined to separate an overloaded mixture of N ,N ′‐diphenylguanidine and N ,N ′‐di(o‐tolyl)guanidine. Baseline separation was achieved due to much small longitudinal dispersion. The theoretical plate numbers of peaks were around 3.5 × 105 m−1. The practicality of the new approach is demonstrated in the separation of a model protein mixture, containing lysozyme, bovine serum albumin, and ribonuclease A.  相似文献   

8.
A non-aqueous capillary electrophoresis (NACE) method for quantifying the seven crocin metabolites that are the major biologically active ingredients of saffron was developed. Separation is done by using a fused silica capillary filled with a 12.5 mM H3BO3/37.5 mM sodium tetraborate methanolic solution as background electrolyte. The results obtained were compared with the total index "safranal value", widely used as a quality measure of saffron products. The comparison revealed that the proposed NACE method provides useful information not obtained in the safranal value. Infact, samples with a similar safranal value can contain crocin metabolites in different concentrations and relative proportions. This new method is very useful for quality control in commercial saffron samples.  相似文献   

9.
采用动态pH联接-扫集毛细管电泳法对化妆品中的迷迭香酸进行检测。用重力进样的方式,进样高度为15 cm的情况下,研究了硼砂浓度、pH、十二烷基硫酸钠(SDS)浓度、甲醇浓度、样品基体、进样时间、分离电压对富集与分离的影响。优化后的实验条件:15 mmol/L硼砂-45 mmol/L SDS(pH8.8)-15%甲醇为缓冲液,进样时间60s,分离电压16kV,样品中磷酸盐浓度10 mmol/L,样品基质pH 4.7。在上述条件下,迷迭香酸(RA)的线性回归方程式为y=539200ρ+53588(r=0.9985),线性范围为0.144~3.6μg/mL,检出限0.036μg/mL,迷迭香酸的回收率为92.5%~103%,相对标准偏差为2.5%。  相似文献   

10.
A sensitive and effort-saving method was established and validated for the quantitative determination of recombinant Arg-Gly-Asp-hirudin (rRGD-hirudin) in human urine samples. The assay was performed on a uncoated fused silica capillary of 70 cm × 50 μm I.D. and a positive voltage of 30 kV was applied. The sample was injected under pressure of 50 mbar for 300 s and the temperature of capillary was kept 25 °C. Sheath liquid consisting of 30% methanol and 70% of 0.1% formic acid aqueous solution flowing at 7 μL/min was supplied to the CE-electrospray interface. Utilizing the dynamic pH junction technique, a lower limit of quantitation of approximately 35 nM was achieved (concentration coefficiency was about 100-fold) without complex sample preprocessing procedure. CE-MS conditions and parameters were also optimized to obtain better performance. The method has been successfully applied in clinical research of rRGD-hirudin.  相似文献   

11.
A novel, rapid and continuous on-line concentration approach based on dynamic pH junction for the analysis of trimethoprim (TMP) and sulfamethoxazole (SMZ) by microfluidic capillary electrophoresis (CE) combined with flow injection analysis is developed in this paper. Stacking is due to decreases in the velocity of analytes when migrating from the low-pH sample zone (sample was dissolved in 50 mM HCl) to a relatively high-pH buffer (30 mM phosphate buffer, pH 8.5) filled in the capillary. This results in 2.9-4.7-fold improvement in concentration sensitivity relative to conventional capillary electrophoresis methods. The separation could be achieved within 2 min and sample throughput rate can reach up to 38 h(-1).  相似文献   

12.
To improve detection sensitivity of cationic analytes, a dynamic pH junction technique was examined. Dynamic pH junction is an on-line focusing method in capillary electrophoresis (CE) based on the difference in the analyte's mobility between the background electrolyte (BGE) and sample matrix. The effects of pH values and concentrations of the BGE and the sample matrix on dynamic pH junction were examined. Optimization of analyte focusing resulted in enhanced detection responses of about 100-160-fold in terms of peak heights for some anilines in comparison to conventional injections. In particular, the concentration limits of detection (LOD) (S/N = 3) for the test anilines obtained with dynamic pH junction were from 1.9 to 3.7 ppb with UV detection without any pretreatment procedure.  相似文献   

13.
The aim of the study was to develop a new capillary zone electrophoresis (CZE) method for determination of enzymatic activity of hyaluronidase. The method permits monitoring of the process of hyaluronic acid digestion by hyaluronidase. Studies were performed using CZE instrument equipped with capillary of 64.5 cm total length, 56 cm effective length and internal diameter 75 µm. Separation was performed in the phosphate buffer (pH 8.10) in the electric field of 20 kV, λ = 220 nm. The procedure was based on mixing a known quantity of hyaluronic acid and an aliquot of hyaluronidase solution, followed by obtaining CZE profiles after a known period of incubation (0.5 h). The activity of hyaluronidase was calculated using multiple regression analysis in which sizes of the peaks of the main degradation products were used. The newly developed method was fully validated and it is appropriate to evaluate the activity of hyaluronidase originating from different sources with high precision and accuracy. t‐Tests showed that there were no significant differences between results obtained using turbidimetric, viscosimetric and the new CZE method. The developed method is characterized by a short duration of analysis, low volume of analyzed sample, small amount of buffers used and low cost of analysis. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
A precise and accurate method has been developed for the determination of methylmercury in biological material using capillary gas chromatography with electron-capture detection. Homogenized fish or mussel samples were digested with acid, spiked with ethylmercury chloride as an internal standard and extracted with toluene. After treatment of the solvent extract with sodium thiosulphate and cupric bromide the alkylmercurials were extracted into benzene as their bromide derivatives and analyzed using an OV-275 coated glass capillary column. The detection limit of the method for methylmercury was 5 g/kg tissue.  相似文献   

15.
Su HL  Feng LI  Jen HP  Hsieh YZ 《Electrophoresis》2008,29(20):4270-4276
We have employed a high-sensitivity on-line preconcentration method, cation-selective exhaustive injection (CSEI) and sweeping MEKC, for the analysis of cocaine, benzoylecgonine, norcocaine, and cocaethylene. We monitored the effects of several of the CSEI-sweeping-MEKC parameters - including the pH, the concentrations of SDS and organic modifier, the injection length of the high-conductivity buffer, and the injection time of the sample - to optimize the separation process. The optimal BGE was 100 mM phosphoric acid (pH 1.8) containing 75 mM SDS with 10% 2-propanol and 10% tetrahydrofuran as the organic modifier. In addition, electrokinetic injection of the sample at 15 kV for 900 s provided both high separation efficiency and enhanced sweeping sensitivity. The sensitivity enhancements for cocaine, norcocaine, and cocaethylene ranged from 2.06 x 10(4) to 3.96 x 10(4); for benzoylecgonine it was 1.75 x 10(3); the coefficients of determination exceeded 0.9958. The LODs, based on an S/N ratio of 3:1, of sweeping-MEKC ranged from 33.5 to 52.8 ng/mL; in contrast, when using CSEI-sweeping-MEKC the sensitivity increased to range from 29.7 to 236 pg/mL. Under the optimal conditions, we analyzed cocaine in a human urine sample prepared using off-line SPE to minimize the influence of the matrix. The recovery of the SPE efficiency was satisfactory (ca. 74.9-87.6%). Our experimental results suggest that, under the optimal conditions, the CSEI-sweeping-MEKC method can be used to determine cocaine and its metabolites with high sensitivity in human urine.  相似文献   

16.
An on-line sample stacking method, namely field-amplified sample injection, has been developed for the separation and determination of carnosine, anserine, and homocarnosine by capillary electrophoresis. Using electrokinetic injection, about 130- to 160-fold improvement of sensitivity was achieved without loss of separation efficiency when compared to conventional sample injection. For conventional injection, the samples were dissolved in running buffer and then hydrodynamically injected for 10 s (3.45 kPa). Various parameters affecting separation and sample stacking were optimized. Under optimum conditions, linear responses were obtained over two orders of magnitude and the detection limits (defined as S/N = 3) of carnosine, anserine, and homocarnosine were 1.5 x 10(-8) to 1.6 x 10(-8) mol/L.  相似文献   

17.
An online preconcentration technique by dynamic pH junction was studied to improve the detection limit for anionic arsenic compounds by CE. The main target compound is roxarsone, or 3-nitro-4-hydroxyphenylarsonic acid, which is being used as an animal feed additive. The other inorganic and organoarsenic compounds studied are the possible biotransformation products of roxarsone. The arsenic species were separated by a dynamic pH junction in a fused-silica capillary using 15 mM phosphate buffer (pH 10.6) as the BGE and 15 mM acetic acid as the sample matrix. CE with UV detection was monitored at a wavelength of 192 nm. The influence of buffer pH and concentration on dynamic pH junction were investigated. The arsenic species focusing resulted in LOD improvement by a factor of 100-800. The combined use of C18 and anion exchange SPE and dynamic pH junction to CE analysis of chicken litter and soils helps to increase the detection sensitivity. Recoveries of spiked samples ranged between 70 and 72%.  相似文献   

18.
In this work, a simple online preconcentration method for quantitative detection of pepsin was realized by using the binary mixed polymer brushes coated capillary with switchable properties toward protein adsorption. Firstly, the binary mixed polymer brushes were prepared by grafting poly(2-methyl-2-oxazoline) and poly(4-vinylpyridine) onto the inner wall of the capillary through a polydopamine anchor. Then the coatings were characterized by X-ray photoelectron spectrometer and electroosmotic flow measurement. The results indicated that the composition of coating could be controlled by varying the feed ratio of poly(2-methyl-2-oxazoline) to poly(4-vinylpyridine) and the inner surface charge could be tuned toward the change of pH and ionic strength. The results showed that when the poly(2-methyl-2-oxazoline)/poly(4-vinylpyridine) mass ratio was 80/20, the highest online preconcentration effect was obtained and the sensitivity enhancement factor was 6.3. Moreover, satisfactory sensitivity (limit of detection: 7.5 ng/mL) and good repeatability were obtained with the online preconcentration method. The polymer-coated capillary was still stable for online preconcentration and detection of pepsin after 50 consecutive runs. Last, the proposed method was used successfully to online preconcentrate pepsin in the saliva matrix.  相似文献   

19.
Systemin is an important group of plant peptide hormones participating in the regulation of plant defensive responses. An improved method, based on dynamic pH junction and capillary electrophoresis‐quadrupole time‐of‐flight mass spectrometry, was developed for online enrichment and sensitive determination of trace systemins in plants. After optimization, the online enrichment factors for six target systemins ranged from 90‐ to 127‐fold. The detection limits reached lower than 0.5 nM, which were comparable with the sensitivity of LC‐MS method. Satisfactory quantitative results were obtained in terms of linearity (R2 ≥ 0.993), dynamic range (3–120 ng/mL), and reproducibility (≤6.7%). For the analysis of real plant samples, a rapid sample preparation method was developed, using two steps of SPE purification with different retention and separation mechanisms. Finally, this method realized the successful detection of tomato systemin and tobacco hydroxyproline‐rich systemin I from plant leaves with shorter analysis time.  相似文献   

20.
Large volume stacking using the electroosmotic flow (EOF) pump (LVSEP) in capillary electrophoresis under a reverse potential is a convenient and straightforward approach for on-line concentration of dilute anionic sample solutions. LVSEP achieves automatic sample matrix removal and subsequent separation without intermediate polarity switching nor complicated instrumental setup. Since anionic analytes should move against the EOF in LVSEP, EOF needs to be suppressed. We extended the range of LVSEP up to pH 11 using various EOF suppression methods, such as dynamic coating by polymer pretreatment and permanent coating. Weakly acidic organic compounds (pKa<5.2), chlorinated phenols (pKa=7-9), and aromatic amino acids (pKa2∼9.3) were concentrated and separated. By hydrodynamically filling the whole capillary of 27 cm long with the sample solution, fast and reliable injection was achieved and sensitivity enhancement factors as large as 170 were readily obtained in less than 8 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号