首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
在线单柱二维液相色谱法快速纯化牛胰腺中细胞色素C   总被引:1,自引:0,他引:1  
用二维(弱阳,疏水)色谱柱首次完成了在线单柱二维液相色谱法快速纯化牛胰腺中的细胞色素C.在将牛胰腺粗提液进样到该二维色谱柱后,在弱阳离子交换模式下,以梯度洗脱方式进行一维色谱分离,并将分离得到的细胞色素C样品液收集到色谱仪的附加样品储液管内.然后将储液管中样品液全部排出,并二次进样到同一根二维色谱柱中,与此同时也完成了对该样品液的缓冲溶液交换,按疏水色谱(HIC)分离模式进行分离.最终对细胞色素C完成了第二维的HIC纯化.上述全部操作均为在线,在一具有正压的封闭体系中进行并可在52分钟内完成.细胞色素C的最终产品纯度高达94.7%(RSD=1.91%),质量回收率为80.5%(RSD=2.20%).预计此在线单柱二维液相色谱法也可能用于牛胰腺中其他功能蛋白的快速纯化,并可能将其放大到制备和生产规模.  相似文献   

2.
Summary Separations of compounds in plasma were performed on a Hypersil Duet C18/SCX capillary electrochromatography (CEC) column, utilizing an automated injection system combined with a short in-house designed and fabricated micro-electrospray CEC mass spectrometer interface. Protein precipitation was used prior to the CEC separations. More than two hundred separations of the corticosteroids Dexamethasone and Betamethasone 17-valerate, and Fluticasone Propionate in complex plasma matrix were performed on a single column under isocratic conditions. The method demonstrated good reproducibility, selectivity, sensitivity and high efficiencies. Linear calibration with good correlation was typical. Estimated detection limits in the low micromolar and nanomolar range for all compounds were obtained using UV-Vis absorbance (UV) and Electrospray Mass Spectrometric (ES/MS) detection respectively. Efficiencies for all compounds were typically 87,500 plates on a 25 cm column (350,000 plates m−1) and increased with the number of plasma samples injected, up to 250,000 plates per column (1,000,000 plates m−1). These very high observed plate counts may be artificially enhanced by the inadequate scan possibilities of the MS over very narrow chromatographic peaks.  相似文献   

3.
In this work, the simultaneous analysis of five triazolopyrimidine sulfoanilide herbicides (flumetsulam, florasulam, metosulam, cloransulam-methyl, and diclosulam) by HPLC using UV detection and a C18 monolithic column is proposed. The mobile phase which was composed of ACN, water, and formic acid was pumped at a high flow rate (5 mmL/min) providing an analysis time of all the compounds in less than 2.3 min. The LODs were in the low microg/L range (i.e. between 60 microg/L for flumetsulam and 90 microg/L for florasulam) and the calibration curves showed good linearity (R2 > 0.9949). The method was applied to the analysis of these compounds in spiked mineral and tap waters and soils after an SPE preconcentration procedure using C18 cartridges. Mean recovery values ranged between 35 and 110% for water samples providing LODs of the whole procedure in the low ng/L level, down to 280 ng/L, and between 77 and 92% for soil samples with LODs down to 9.38 microg/kg. This is the first time that this family of pesticides is simultaneously analyzed in both types of samples by HPLC and also using a monolithic column.  相似文献   

4.
Application of polymeric probes was proposed for evaluation of partition properties of the high performance liquid chromatographic stationary phases. The approach was tested with selected silica gel C-18 column packings. Polystyrene (PS) and poly(n-butyl methacrylate) (PnBMA) narrow molar mass standards of low polarity were applied to avoid adsorption of macromolecules on silanols and other polar groups present within column packings. Polar eluent components further reduced contingency of silanophilic interactions. The major eluent component was dimethylformamide (DMF), a thermodynamically poor solvent for polymer probes, which strongly promoted enthalpic partition of macromolecules in favor of the C18 bonded phase. Methyl ethyl ketone (MEK) and diethyl malonate (DEM) were also tested as the partition promoting eluent components. With polystyrenes, MEK was rather inefficient as a partition promoter while DEM was similarly active as DMF. A thermodynamically good solvent for polymer probes, viz. tetrahydrofuran (THF) was added to eluent to reduce and control the extent of partition. The differences in elution behavior of column tested indicate their unlike partition properties.  相似文献   

5.
An HPLC method of high resolution has been developed and validated for the simultaneous determination of ten prominent flavonoid aglycones in plant materials using a fused‐core C18‐silica column (Ascentis® Express, 4.6 mm × 150 mm, 2.7 μm). The separation was accomplished with an acetonitrile‐tetrahydrofuran gradient elution at a flow rate of 1 mL/min and temperature of 30°C. UV spectrophotometric detection was employed at 370 nm for flavonols (quercetin [QU], myricetin [MY], isorhamnetin [IS], kaempferol [KA], sexangularetin [SX], and limocitrin [LM]) and 340 nm for flavones (apigenin [AP], acacetin [AC], chrysoeriol [CH], and luteolin [LU]). The high resolution of critical pairs QU/LU (10.50), QU/CH (3.40), AP/CH (2.51), SX/LM (2.30), and IS/KA (2.70) was achieved within 30.3 min. The observed column back pressure was less than 4300 psi, thus acceptable for conventional HPLC equipment. The method was sensitive enough having LODs of 0.115–0.525 ng and good linearity (r > 0.9999) over the test range. The precision values, expressed as RSD values, were <7.5%, and the accuracy was in the range of 95.3–100.2% for all analytes except MY (73.8%). The method was successfully employed for the determination of flavonoids in several medicinal plants, such as Ginkgo biloba, Betula pendula, and a variety of Sorbus species.  相似文献   

6.
High-performance liquid chromatography using a Chrompack P-300-RP column containing a polystyrene-divinylbenzene copolymer-based packing was examined to analyze bovine milk protein components. The separation of major raw-milk proteins could be performed rapidly and reliably with this HPLC/UV method. The determinations were performed in the linear ranges of 0.01-2.0 mg/ml for alpha-lactalbumin, 0.04-2.5 mg/ml for caseins and 0.02-2.0 mg/ml for beta-lactoglobulin. The validity of the method was verified. Since the chromatographic column enabled the quantification of only "native" milk proteins, the extent of denaturation and loss of milk proteins could be examined. Thus, evaluation of heat-induced proteins denaturation was carried out in raw milk heated for 5 min at pre-determined temperatures.  相似文献   

7.
The simultaneous determination of Cr(III) and Cr(VI) by ion interaction chromatography has been investigated. The mobile phase consisted of a 5 mM octylammonium orthophosphate at pH 4.0 with 35% (v/v) MeOH. The Nucleosil-100, C18 (5 microm, 250 x 4.6 mm) was used as the separating column and the component was detected at 200 nm. The separation of Cr(III) and Cr(VI) was based on anionic interaction. Since the Cr(III) did not exist as an anionic form like the Cr(VI) (Cr2O7(2-)) presented at the optimum condition, Cr(II) was firstly reacted with EDTA (1:40 mole ratio) to form the anionic complex prior to injecting into the chromatographic system. The characteristics of the method for separation of Cr(III)-EDTA and Cr(VI) were satisfactory. The wide linear range (0.3-50.0 mg l(-1)) was achieved. The repeatabilities (%R.S.D.) calculated from peak areas were 0.49% and 0.14%, detection limit (signal to noise ratio of 3) of 0.02 mg l(-1) and 0.3 mg l(-1) were obtained and the average of percent recoveries were found to be 98.5% and 99.6% for Cr(III) and Cr(VI), respectively.  相似文献   

8.
The choice of T and tG as variables for controlling selectivity and resolution during reversed-phase liquid chromatography (RPLC) method development can be used to minimize problems caused by column batch-to-batch irreproducibility. When a new column fails to provide adequate separation of the sample, altered values of T and tG can be predicted that will restore the separation obtained with the previous column. Alternatively, columns from different manufacturers can be tested during method development, in order to find a common set of conditions (T and tG) that provide acceptable separation with two or more of these columns. In this way, any of several columns from different sources become usable for the method. Examples are shown of these different computer-assisted procedures for minimizing problems due to column variability.  相似文献   

9.
A method was developed for the preconcentration and separation of trace manganese from natural water samples by complexation with dithiocarbamate followed by adsorption onto C18-solid phase extraction column prior to irradiation. The Mn recovery was better than 99.8% without inteference from iron(III) at 5 mg.l-1, copper(II), zinc(II), aluminum(III) and cobalt(II) at 0.5 mg.l-1 and sodium(I), potassium(I), magnesium(II) and calcium(II) at 1 mg.l-1. The separation factor was 100 and the detection limit was 0.01 μg.l-1 with good precision and accuracy with a relative error lower than 3%. The method was applied to the determination of Mn in tap, well, river and treated water samples. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   

10.
Gaseous samples of fresh tobacco smoke were injected on to a packed polar column (2,2-oxydipropionitrile) in all-glass chromatographic system. With the aid of a warm syringe, selected fractions were withdrawn from the bottom of the electron capture detector of the packed column for further injection into an efficient non-polar glass capillary column (SF-96), connectable on-line to a mass spectrometer. The method has permitted the separation and identification of some polar and non-polar components of tobacco smoke, which gave previously mixed, broad, tailing peaks when the smoke was injected directly into a non-polar capillary column.  相似文献   

11.
A simple high-performance liquid chromatography (HPLC) method for the separation and quantitative determination of the main antioxidant phenolic compounds from bitter fennel, Foeniculum vulgare, was developed. The use of a narrow bore reversed phase (RP) C18 column and an acidic mobile phase enabled ten compounds (caffeoylquinic acids, dicaffeoylquinic acids, flavonoids and rosmarinic acid) to be separated within a 40 min time analysis. The method was validated to demonstrate its selectivity, linearity, precision, accuracy and robustness. In addition, some parameters were studied to optimize the complete extraction of the phenolic compounds. The method was applied to the evaluation of three different fennel materials: distilled and non-distilled aerial parts, as well as defatted fruits. Distilled fennel was found to contain a higher proportion of antioxidant phenolic compounds than the non-distilled plan material.  相似文献   

12.
Successful remediation of oil-contaminated soils relies on a sound preceding characterization of the oil chemical composition and physicochemical properties. Comprehensive two-dimensional gas chromatography with flame ionization detection (GCxGC/FID) is known to be very suitable for the analysis of complex samples such as petroleum hydrocarbons. However, in spite of the high-separation power offered by GCxGC, it fails to completely separate certain hydrocarbon groups in petroleum hydrocarbon mixtures. This hampers a detailed chemical composition assessment which can lead to wrong conclusions on the behaviour of the oil in soil systems, e.g. biological degradability and water solubility. This paper describes a high-performance liquid chromatography (HPLC) system with a silver-modified column as a prefractionation step to GCxGC to improve chemical identification. With HPLC, the petroleum hydrocarbons were baseline separated into a saturated fraction (including alkanes and cycloalkanes) and an unsaturated fraction (including alkenes, aromatic hydrocarbons and heterocyclic components). Each fraction eluted in a small time window limiting the dilution caused by HPLC. The two fractions were collected and quantitatively analyzed with GCxGC/FID. Cold splitless injection of 4 microl was adopted to compensate the dilution caused by the prefractionation step. With oil-spiked soil samples, a good reproducibility was obtained (RSD=3.5%; n=7) and the recovery was satisfactory (87.7%).  相似文献   

13.
14.
An ultra‐fast high‐performance LC‐ESI‐MS/MS method was developed for the analysis and quantification of caffeoylquinic acid derivatives, including chlorogenic acid, 1,3‐di‐O‐caffeoylquinic acid (cynarin) and 1,5‐di‐O‐caffeoylquinic acid, in artichoke (Cynara scolymus L.) heads and leaves. The rapid separation (less than 4 min) was achieved based on a Halo fused core C18‐silica column (50 mm×2.1 mm id, 2.7 μm). The target compounds were detected and quantified by a triple‐quadrupole mass spectrometer in multiple‐reaction monitoring mode. The calibration function is linear from 0.06 to 2800 ng/mL for chlorogenic acid, 0.3–3000 ng/mL for cynarin and 0.24–4800 ng/mL for 1,5‐di‐O‐caffeoylquinic acid, respectively. The average recoveries ranged from 92.1 to 113.2% with RSDs ≤6.5%. Moreover, four batches of artichoke head and leaf extracts were analyzed using the established method. The results indicated that the Halo fused core column provided much faster separations and higher sample throughput without sacrificing column ruggedness and reliability, and triple‐quadrupole MS provided extraordinarily lower LOQs for most of the target analytes. Comparing to conventional quantitative approaches, the established method was fast, sensitive and reliable for the determination of caffeoylquinic acid derivatives in artichoke.  相似文献   

15.
On-line coupled analytical techniques can be advantageous in the assay of smaller peptides in complex biological matrices such as plasma, cerebrospinal fluid (CSF) and tissues. The present study shows the feasibility of a recently developed system, consisting of a size-exclusion chromatographic (SEC) separation followed by a trapping procedure on an RP18 microcolumn with subsequent elution of the trapped fraction and separation by capillary zone electrophoresis (CZE) for the quantification of structural-related peptides in biological matrices, as demonstrated for a number of enkephalins in CSF. After SEC separation of the enkephalins from large proteins present in CSF a heart-cut of 200 nuL, containing the enkephalin peak, is taken, concentrated on the RP18 microcolumn and, after elution of the enkephalins with 80% acetonitrile, a fraction of the eluate is electrokinetically injected into the CZE system, where stacking and separation is achieved. The degradation of the peptides, caused by endogenous peptidases in the matrix, is sufficiently inhibited with imipramine HCl. The assay has a satisfactory linearity and intraday (9.70-16.3%) precision considering the complexity of this multidimensional separation system. The sensitivity of the method, with a concentration limit of quantification of 2.5 nug/mL, is comparable with other CZE assays for peptides and sufficient for the quantification of peptide drugs in biological matrices.  相似文献   

16.
A pair of flavanone glucoside diastereomers, (2R)- and (2S)-eriodictyol-5-O-beta-d-glucopyranoside (1a, 1b), was successfully separated by RP-C(18) high-performance liquid chromatography from Balanophora involucrata Hook. f. Some other compounds, including a pair of flavanone enantiomers, (2R)- and (2S)-eriodictyol (2a, 2b), and a pair of flavanone glucoside diastereomers, (2R)- and (2S)-eriodictyol-7-O-beta-d-glucopyranoside(3a, 3b), were separated by capillary electrophoresis from the same plant. The absolute configurations at C-2 of 1a and 1b were determined based on their circular dichroism spectra. Enzymatic hydrolysis of 1a and 1b by beta-d-glucosidase afforded (2R)- and (2S)-eriodictyol, respectively, which were used as the authentic standards for co-elution to determine the migration order of the enantiomers, 2a and 2b. We also report the first example of identifying the migration order of 2a and 2b and resolving the separation of 3a and 3b by capillary electrophoresis. In addition, 1a was unambiguously characterized for the first time by NMR spectra.  相似文献   

17.
HPLC procedures using conventional C18 columns are usually used to separate simple and complex lipid mixtures but these methods of separation remain often laborious and very slow. Here, monolithic columns were successfully applied to separate lipids - radiolabelled fatty acid mixtures and individual phosphatidylcholine (PC) molecular species. For that, isocratic elution was performed using two Chromolith™ Performance RP-18e columns connected in series. Detection was achieved by online measurement of radioactivity for radiolabelled fatty acids and by UV absorbance at 205 nm for PC molecular species. The performances of such silica rods were compared to conventional reverse-phase silica columns. Monolithic stationary phase separated radiolabelled fatty acids and PC molecular species two times and four times faster, respectively. In each analysis, monolithic columns allowed better separation efficiency per unit of time, with lower inlet pressure. The main advantages of this method for lipid separation are that, under isocratic conditions, it is simpler and much faster, while remaining accurate and selective when compared to conventional methods. Therefore, monolithic columns may represent a powerful tool for the near future in the field of lipidomics.  相似文献   

18.
Jiang X  Dong J  Wang F  Feng S  Ye M  Zou H 《Electrophoresis》2008,29(8):1612-1618
An automated nano-LC-MS/MS platform without trap column was established, which only used a 20 cm lauryl methacrylate-ethylene dimethacrylate (LMA-EDMA) monolithic capillary column to allow preconcentration and separation of peptides. The monolithic column had the advantages of good permeability and low backpressure resulting in higher flow rates for capillary columns. Tryptic digests of bovine albumin and yeast protein extract were tested using the monolithic column system. High proteomic coverage using this approach were demonstrated in this study. Furthermore, peptide samples extracted from mouse liver were separated by using the monolithic column system combined with size-exclusion chromatography prefractionation. This monolithic column system might be a promising alternative for the automated system previously using a trap column for routine proteome and peptide profiling analysis.  相似文献   

19.
The elution of ions from a C18 column with mobile phases containing methanol (60%, v/v) and aqueous buffers is studied by mass spectrometry. It is demonstrated that the anions are excluded from the stationary phase by the ionized silanols. However, the ionized silanols interact strongly with cations, which are retained in the column. These cations are later eluted from the column by ion exchange with the cations present in the pH buffered mobile phase. The size of the ions, the mobile phase cation concentration and the mobile phase pH are the main parameters that affect elution of the retained cations. It is also demonstrated that there are at least two different types of ionizable silanols, with different acidities, that contribute to the retention of cations. An estimate of the pKa values of these two groups of silanols in 60% methanol is given.  相似文献   

20.
A continuous and simple UV-photometric flow-through biparameter-sensing device has been developed for the simultaneous determination of paracetamol and caffeine at 275 nm. The sensor is based on temporary sequentiation in the arrival of the analytes to the sensing zone by on-line separation using C18 bonded phase beads (the same as that used in the sensing zone) placed into a minicolumn just before the flow cell. The sample containing these compounds is injected into the carrier solution; paracetamol is determined first because it passes through the minicolumn, while caffeine is strongly retained in it. Then, caffeine is conveniently eluted from the precolumn and develops its transitory signal. Using 200 microl of a sample and deionized water as a carrier, the analytical signal showed a very good linearity in the ranges of 10-160 microg ml(-1) and 3.5-50 microg ml(-1) with detection limits of 0.75 and 0.56 microg ml(-1) for paracetamol and caffeine, respectively. If deionized water with the pH adjusted at 12 was used as a carrier solution, these parameters were 25-400 and 4-55 microg ml(-1) with 2.0 and 0.50 microg ml(-1) as the detection limits, respectively. The biparameter optosensor was satisfactorily applied to the simultaneous determination of these two analytes in pharmaceuticals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号