首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Xu Y  Qin W  Li SF 《Electrophoresis》2005,26(3):517-523
A portable capillary electrophoresis (CE) system with a novel potential gradient detection (PGD) was utilized to separate DNA fragments. For the first time it was demonstrated that separation of DNA fragments in polymer solution could be detected by a portable CE system integrated with PGD, with a limit of detection (LOD) comparable to that of the CE-ultraviolet (UV) method. Effects of buffer solution, sieving medium, and applied voltage were also investigated. The portable CE-PGD system shows several potential advantages, such as simplicity, cost effectiveness, and miniaturization.  相似文献   

2.
Xu Y  Li SF 《Electrophoresis》2006,27(20):4025-4028
It was demonstrated that separation of DNA fragments by a CE-contactless conductivity detection system (CE-CCD) could be enhanced with multiple-wall carbon nanotubes (MWCNs) as buffer additive. For HaeIII digest of PhiX174 DNA, optimized MWCN concentration was obtained when the MWCN was above its threshold concentration, at which MWCN could form a network in the buffer as pseudostationary phase to provide additional interaction sites. In the case of larger DNA, MWCN near or below its threshold concentration was enough to provide great improvement of the resolution, which was shown by the separation of the 2-Log DNA ladder. Furthermore, the buffer containing MWCN could provide a more stable baseline in the CE-CCD system, owing to less fluctuation of its conductivity. Compared with CE-UV, CE-CCD with MWCN could provide lower LODs as well as better resolution.  相似文献   

3.
基于微芯片电泳的脱氧核糖核酸片段的浓缩和分离   总被引:1,自引:0,他引:1  
徐中其  廣川健 《色谱》2009,27(1):102-106
采用超负荷电动供给(electrokinetic supercharging, EKS)预浓缩技术,在微芯片电泳(MCE)上对脱氧核糖核酸(DNA)片段进行浓缩和分离。EKS是集合样品电动进样(EKI)和过渡等速电泳(tITP)的一种在线浓缩方法。研究表明:采用该方法后,在40.5 mm长的单通道芯片上能够实现对低浓度样品的大量进样、浓缩和基线分离。在普通的紫外检测条件(检测波长为260 nm)下,对DNA片段的平均检出限(S/N=3)约为0.07 mg/L,仅为十字芯片上的微芯片电泳检出限的1/40。本文还对浓缩过程中的一些关键因素和定性分析进行了探讨。  相似文献   

4.
We developed a new kind of capillary array for electrophoresis by using the numerical-control (NC) wiring technique conventionally used to produce printed-circuit boards. Laminating two polyimide sheets after laying cylindrical capillaries between them according to designed geometries, we fabricated a 16-lane laminated capillary array (LCA) 9.9 cm long, 7.2 cm wide, and 0.5 mm thick in which the effective length of all capillaries was only 10.9 cm. This compact LCA thus had separation columns as short as those in capillary array electrophoresis chips fabricated by lithography techniques. Like conventional capillary arrays, it also enabled pipetting-less direct injection of analytes from sample preparation plates. Using the LCA with LIF detection and a replaceable fluid sieving matrix, we demonstrated high-speed ssDNA fragment separations. At an electric field strength of 316 V/cm, 15 fragments ranging from 50 to 500 bases were completely separated within 5.8 min in all lanes. The lane-to-lane CV of migration time was only 0.38%, and the fragment size for which the resolution per base was 0.59 was 258 +/- 15 bases (average +/-SD).  相似文献   

5.
Han F  Xue J  Lin B 《Talanta》1998,46(4):735-742
A new kind of sieving matrix is presented in this paper to allow satisfactory separation of DNA fragments in a relatively low viscous solution. When a certain amount of mannitol was added to cellulose solution not concentrated enough to separate PGEM-3Zf(+)/HaeIII standards well, a polymer solution with low viscosity but with very good separation effects was obtained. The separation result of this sieving buffer was comparable with those using highly concentrated cellulose solutions. The sieving ability of solutions with different cellulose concentrations and different amounts of mannitol has been investigated. It was proved that 0.5% was the minimum hydroxypropylmethylcellulose (HPMC) concentration that could be used to separate DNA fragments satisfactorily. HPMC solutions with a concentration of less than 0.5% could not separate the standard DNA fragments even in the presence of mannitol. It was found that 6% was the optimized mannitol concentration because either more or less mannitol will lead a decrease of resolution. The principle of the positive influence of mannitol has also been discussed.  相似文献   

6.
He QH  Fang Q  Du WB  Huang YZ  Fang ZL 《The Analyst》2005,130(7):1052-1058
An automated and continuous sample introduction system for microfluidic chip-based capillary electrophoresis (CE) was developed in this work. An efficient world-to-chip interface for chip-based CE separation was produced by horizontally connecting a Z-shaped fused silica capillary sampling probe to the sample loading channel of a crossed-channel chip. The sample presentation system was composed of an array of bottom-slotted sample vials filled alternately with samples and working electrolyte, horizontally positioned on a programmable linearly moving platform. On moving the array from one vial to the next, and scanning the probe, which was fixed with a platinum electrode on its tip, through the slots of the vials, a series of samples, each followed by a flow of working electrolyte was continuously introduced electrokinetically from the off-chip vials into the sample loading channel of the chip. The performance of the system was demonstrated in the separation and determination of FITC-labeled arginine and phenylalanine with LIF detection, by continuously introducing a train of different samples. Employing 4.5 kV sampling voltage (1000 V cm(-1) field strength) for 30 s and 1.8 kV separation voltage (400 V cm(-1) field strength) for 70 s, throughputs of 36 h(-1) were achieved with <1.0% carryover and 4.6, 3.2 and 4.0% RSD for arginine, FITC and phenylalanine, respectively (n = 11). Net sample consumption was only 240 nL for each sample.  相似文献   

7.
Wu CH  Scampavia L  Ruzicka J 《The Analyst》2003,128(9):1123-1130
Automated sampling and fluorogenic derivatization of islet proteins (insulin, proinsulin, c-peptide) are separated and analyzed by a novel lab-on-valve capillary electrophoresis (LOV-CE) system. This fully integrated device is based on a micro sequential injection instrument that uses a lab-on-valve manifold to integrate capillary electrophoresis. The lab-on-valve manifold is used to perform all microfluidic tasks such as sampling, fluorogenic labeling, and CE capillary rejuvenation providing a very reliable system for reproducible CE separations. Fluorescence detection was coupled to an epiluminescence fluorescence microscope using a customized capillary positioning plate. This customized plate incorporated two fused-silica fiber optic probes that allow for simultaneous absorbance and fluorescence detection, extending the utility of this device. Derivatization conditions with respect to the sequence of addition, timing, injection position, and volumes were optimized through iterative series of experiments that are executed automatically by software control. Reproducibility in fluorogenic labeling was tested with repetitive injections of 3.45 mM insulin, yielding 1.3% RSD for peak area, 0.5% RSD for electromigration time, and 2.8% RSD for peak height. Fluorescence detection demonstrated a linear dynamic range of 3.43 to 6.87 microM for insulin (r2 = 0.99999), 0.39 to 1.96 pM for proinsulin (r2 = 0.99195) and 260 to 781 nM for c-peptide (r2 = 0.99983). By including hydrodynamic flushing immediately after the detection of the last analyte, the sampling frequency for islet protein analysis was increased. Finally, an in vitro insulin assay using rat pancreatic islet excretions was tested using this lab-on-valve capillary electrophoresis system.  相似文献   

8.
Principles of DNA separation with capillary electrophoresis   总被引:7,自引:0,他引:7  
Heller C 《Electrophoresis》2001,22(4):629-643
During the last decade, capillary electrophoresis (CE) of DNA has undergone rapid development. This improvement was especially important for DNA sequencing, where CE has now become a standard method facilitating to decipher several genomes within a very short time. Here, we give a review of the fundamentals of DNA separation in CE and the major factors influencing the performance.  相似文献   

9.
Ueda M  Kiba Y  Abe H  Arai A  Nakanishi H  Baba Y 《Electrophoresis》2000,21(1):176-180
A laser-induced fluorescence detection system coupled with a highly sensitive silicon-intensified target (SIT) camera is successfully applied to the imaging of a band for DNA fragment labeling by fluorescence dye in a microchannel, and to the visualizing of the separation process on a microfabricated chip. We demonstrated that an only 6 mm separation channel is sufficient for the separation of triplet repeat DNA fragment and DNA molecular marker within only 12 s. The separation using the microfabricated capillary electrophoresis device is confirmed to be at least 18 times faster than the same separation carried out by conventional capillary electrophoresis with 24.5 cm effective length. The use of a short capillary with 8.5 cm effective length is also efficient for fast separation of DNA; however, the microchip technology is even faster than capillary electrophoresis using a short capillary.  相似文献   

10.
Copolymer solutions as separation media for DNA capillary electrophoresis   总被引:2,自引:0,他引:2  
Capillary electrophoresis techniques offer high plate numbers and are highly suited for the efficient separations of a wide variety of chemical components in diverse matrices. Because of the small capillary and detection cell dimensions, together with the minute volumes of samples to be injected, sensitive detection schemes based on different physicochemical principles are being developed. One logical approach to increased sensitivity in capillary electrophoresis detection has been the development of chemiluminescence-based detectors. The development of on-line ultrasensitive chemiluminescence detection (referred to the concentration detection limit of nM order of magnitude or mass detection limit of amol order of magnitude) in capillary electrophoresis system is reviewed. The applications and limitations of the current detection methodology are briefly considered and future prospects for the development are discussed.  相似文献   

11.
A portable CE system was developed for the identification of cattle breeds. The system had a width of 44 cm, depth of 27 cm, height of 13 cm, and a weight of only ∼8 kg and included an LIF detector, with everything integrated into a small box. The specific sizes of genes were quickly separated and detected with a high sensitivity based on the difference in the DNA mobility using a diode‐pumped solid‐state LIF detector. Using this system, the 100‐bp DNA ladder was analyzed under a 1.0% PVP (Mr=300 000) sieving gel matrix in a fused silica capillary with LODs of 4.4–13.0 pg/μL (S/N=3) for 100–3000 bp DNAs, which indicates ten times improved value than other commercialized portable CE system. The migration times and the peak areas showed good reproducibilities with relative standard deviations that were less than 0.49 and 1.3% (n=5), respectively. Based on the difference in the DNA mobility of the microsatellite and SNP markers, Korean cattle and Holstein were exactly identified as the model cattle breeds within 32 and 3.5 min, respectively.  相似文献   

12.
A scheme for the separation and detection of native DNA fragments in capillary electrophoresis is presented. A UV laser at 275 nm excites the intrinsic fluorescence of the fragments, which is greatly enhanced at pH 2.8. To provide a compatible system, methylcellulose-based size separation is performed at the identical pH. A sheath-flow arrangement isolates the detection region from the linear polymer for a reduced background level. The performance is an order-of-magnitude enhancement in detectability over absorption detection. We also uncovered a selective degradation/ligation process at these pH conditions that may be useful as additional selectivity for DNA characterization.  相似文献   

13.
14.
M Tabuchi  Y Baba 《Electrophoresis》2001,22(16):3449-3457
We obtained a high-efficiency separation carrier for proteome analysis by capillary electrophoresis. The addition of curdlan or laminaran to the run buffer hastened the migration time without any degradation in resolution. We propose that for the development of the separation carrier it is necessary to synthetically analyze each of the following mobility factors of electroosmotic flow: buffer ionic strength, additional disturbance and adsorption. The total analysis for buffer and additive will be useful for designing high-throughput screening (HTS) systems for proteome analysis without annoying adsorption.  相似文献   

15.
A novel method is presented to detect DNA fragments separated by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection using inverse-flow derivatization. In electrophoresis, the intercalating dye, thiazol orange was only added to the separation buffer at the positive polarity. The negatively charged DNA fragments migrated from the negative polarity to the positive polarity, while the positively charged dye migrated in the opposite direction. When DNA fragments met with dye ions, the DNA–dye complexes were formed. The complexes continued migrating to the positive end, due to their net negative charges. When the complexes passed through the detection window, the fluorescent signals were generated. Importantly, DNA fragments migrated as their native state before DNA–dye complexes were formed. This procedure was used to detect double stranded DNA (dsDNA) and single stranded DNA (ssDNA) fragments, and polymerase chain reaction (PCR) products. The excellent resolution and good reproducibility of DNA fragments were achieved in non-gel sieving medium. This procedure may be useful in genetic mutation/polymorphism detections.  相似文献   

16.
This study reports improved pulsed field capillary electrophoresis (PFCE) for separation of large DNA ladders. Important analytical conditions, including gel polymer concentration, ratio of forward to backward pulse duration, and separation potential, were investigated for their effects on the separation performance of DNA ranging in size from 0.1 to 10.0 kilo base pairs (kbp). Results show that DNA fragments from 0.1 to 8.0 kbp can be resolved with high resolution, simultaneously, in a short time. The ratio of forward to backward pulse duration affects the separation performance for DNA fragments greater than 1.5 kbp, and 3 or 4 is the optimum value of the ratio for separation of DNA up to 10 kbp. Furthermore, the separations that were obtained with 74–19,329 bp λ-DNA restriction fragments clearly demonstrate a dramatic improvement in the separation time and resolution over the conventionally used square-wave PFCE. The inversion field capillary electrophoresis reported here may help enable future DNA analysis studies to be performed quickly and effectively.  相似文献   

17.
We have investigated the effect of polymer gel reconditioning, the shape of the capillary, the applied electric field, and the capillary length for single-stranded DNA. The polyethylene oxide gel had deformed under the high electric field causing the degradation of the separation power. By the reintroduction of the fresh polyethylene oxide gel for the next run, one-base resolution was recovered. It turned out that the tip of the capillary at the injection side needed to be clean and symmetric for much improved resolution. Changing DNA motion by the pulsed electric field resulted in the separation of DNA far more than 500 bases.  相似文献   

18.
Polyacrylamide gel electrophoresis (PAGE) is used frequently for isolation and purification of DNA fragments. In the present study, DNA fragments extracted from polyacrylamide gels showed significant band broadening in capillary electrophoresis (CE). A pHY300PLK (a shuttle vector functioning in Escherichia coli and Bacillus subtilis) marker, which contained nine fragments ranging from 80 to 4870 bp, was separated by PAGE, and each fragment was isolated by phenol/chloroform extraction and ethanol precipitation. After extraction from the polyacrylamide gel, the peaks of the isolated DNA fragments exhibited band broadening in CE, where a linear poly(ethylene oxide) was used as a sieving matrix. The theoretical plate numbers of the DNA fragments contained in the pHY300PLK marker were >106 for all the fragments before extraction. However, the DNA fragments extracted from the polyacrylamide gel showed decreased theoretical plate numbers (5–20 times smaller). The degradation of the theoretical plate number was significant for middle sizes of the DNA fragments ranging from 489 to 1360 bp, whereas the largest and smallest fragments (80 and 4870 bp) had no obvious influence. The band broadening was attributed to contamination of the DNA fragments by polyacrylamide fibers during the separation and extraction process.  相似文献   

19.
Ni Y  Dou X  Cheng S  Zhu Y 《Electrophoresis》2011,32(2):238-245
Gel-based DNA separation on microchip will play an important role in future genomic analysis due to its potential for high-efficiency and high-speed. Optimal design of microchip and separation condition is essential to take full advantage of high-speed separation on microchip. Separation length L and electric field strength E, which are crucial for design of microchip system, are focused on in this paper. Simultaneous optimization of L and E was carried out to achieve the most rapid separation. It was shown that the condition of L and E and the shortest separation time is closely related to the shape of resolution Rs surface in a three-dimensional space with axes E, L, and Rs. This surface was investigated, taking sample injection, detector, diffusion, and Joule heating into account. Thermal gradient broadening due to Joule heating helps to produce camber or ridge shape of Rs surface, which is essential for the shortest separation length and separation time. Sample plug length and detection volume should be more carefully controlled in microchip. The property of diffusion coefficient was shown to play a key role in determining Rs surface.  相似文献   

20.
A high‐speed separation method of capillary MEKC with LIF detection had been developed for separation and determination of amino acids in laver. The CE system comprised a manual slotted‐vial array (SVA) for sample introduction that could improve the separation efficiency by reducing injection volume. Using a capillary with 80 mm effective separation length, the separation conditions for amino acids were optimized. Applied with the separation electric field strength of 300 V/cm, the ten amino acids could be completely separated within 2.5 min with 10 mol/L Na2HPO4–NaOH buffer (pH = 11.5) including 30 mmol/L SDS. Theoretical plates for amino acids ranged from 72 000 to 40 000 (corresponding to 1.1–2.0 μm plate heights) and the detection limits were between 25 and 80 nmol/L. Finally, this method was applied to analyze the composition of amino acids in laver and eight known amino acids could be found in the sample. The contents of five amino acids, tyrosine, glutamic acid, glycine, lysine, and aspartic acid that could be completely separated in real sample were determined. The recoveries ranged from 82.3% to 123% that indicated the good reliability for this method in laver sample analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏