1.
The objective of this study was to evaluate the potential of sub-2 μm totally porous particles and sub-3 μm shell particles for peptide and protein analysis. Specific analytical strategies must be developed for these biomolecules as their importance in the pharmaceutical industry increases and as their structural complexity involves some issues when classical LC conditions are employed. Attention was paid on comparing these different columns in various LC conditions (different temperatures, gradient times, and mobile phase flow rates). The comparison of the different supports was assessed considering columns characteristics (quality of packing, silanol activity, pore size, totally porous or shell particles). In this article, peptides were first analyzed with both column technologies. Similar results to those achieved with low molecular weight compounds were obtained (peak capacity >100 for tgrad around 3 min and columns dimensions of 2.1 mm id × 50 mm), but specific conditions were required (elevated temperature and the use of a volatile ion-pairing reagent, namely TFA). For peptide analysis following tryptic digestion, the goal was to improve peak capacity and resolution because of the large number of generated peptides. For this purpose, longer columns packed with porous sub-2 μm or shell sub-3 μm particles (i.e., 150 mm) and gradient times (i.e., up to 30 min) were tested. On the other hand, proteins in their intact forms have higher molecular weights (MW > 5000 Da) and a tertiary structure, thus requiring different conditions in terms of stationary phase hydrophobicity (C4vs. C18) and pore size (300 vs. 120 Å). In addition, there were issues with adsorption onto the LC system and/or the column itself. This study showed that proteins with MWs lower than 40,000 Da required chromatographic conditions close to those employed for peptide analysis. For larger proteins, a C4 300 Å stationary phase gave the best results, confirming theoretical predictions.  相似文献   

2.
We report on the optimization of nano‐LC gradient separations of proteomic samples that vary in complexity. The gradient performance limits were visualized by kinetic plots depicting the gradient time needed to achieve a certain peak capacity, while using the maximum system pressure of 80 MPa. The selection of the optimal particle size/column length combination and corresponding gradient steepness was based on scouting the performance of 75 μm id capillary columns packed with 2, 3, and 5 μm fully porous silica C18 particles. At optimal gradient conditions, peak capacities up to 500 can be obtained within a 120 min gradient using 2 μm particle‐packed capillary columns. Separations of proteomic samples including a cytochrome c tryptic digest, a bovine serum albumin tryptic digest, a six protein mix digest, and an Escherichia coli digest are demonstrated while operating at the kinetic‐performance limit, i.e. using 2‐μm packed columns, adjusting the column length and scaling the gradient steepness according to sample complexity. Finally, good run‐to‐run retention time stability (RSD values below 0.18%) was demonstrated applying ultra‐high pressure conditions.  相似文献   

3.
A commercially available 4.6 mm id x 50 mm polymethacrylate-based monolithic strong anion exchange column (ProSwift SAX-1S) designed for the separation of proteins has been successfully used to separate small inorganic anions in the presence of a seawater sample matrix. Using a hydroxide eluent with suppressed conductivity detection the ion exchange capacity of this column declined over time; however, using KCl as the eluent, the column performance was stable with a capacity of 530 microequiv. for nitrate. The optimum conditions for the separation of iodate, bromate, nitrite, bromide and nitrate were assessed by constructing van Deemter plots using 1.00 and 0.100 M KCl. Efficiencies of up to 26 700 plates/m were recorded using 1.00 M KCl, at a flow rate of 0.20 mL/min but iodate was not baseline resolved from the void peak. By reducing the concentration of the eluent to 0.100 M, efficiencies of up to 39 900 plates/m could be obtained at 0.35 mL/min. By employing a linear gradient ranging from 0.05 to 1.00 M KCl the ions dissolved in distilled water or a salt water matrix could be baseline separated in less than 3 min at a flow rate of 2.50 mL/min.  相似文献   

4.
Small columns packed with core-shell and sub-2 μm totally porous particles and monolith columns are very popular to conduct fast and efficient chromatographic separations. In order to carry out fast separations, short (2-5 cm) and narrow-bore (2-2.1 mm) columns are used to decrease the analyte retention volume. Beside the column efficiency, another significant issue is the extra-column band-spreading. The extra-column dispersion of a given LC system can dramatically decrease the performance of a small very efficient column. The aim of this study was to compare the extra-column peak variance contribution of several commercially available LC systems. The efficiency loss of three different type 5 cm long narrow bore, very efficient columns (monolith, sub-2 μm fully porous and sub-2 μm core-shell packing) as a function of extra-column peak variance, and as a function of flow rate and also kinetic plots (analysis time versus apparent column efficiency) are presented.  相似文献   

5.
A new, trilobal‐shaped capillary‐channeled polymer fiber is under development to address the issues of poor A‐term performance of the previous eight‐channeled form. The trilobal geometry should provide better packing homogeneity due to the fewer potential orientations of the symmetric fiber geometry. Comparisons of separation efficiency and peak shape were made between the two fiber shapes through several dynamic parameters. Column hydrodynamics were investigated with two marker compounds, uracil and bovine serum albumin, with van Deemter plots of those two compounds revealing differences in the packing qualities between the different fiber shapes. Parametric fitting to the van Deemter, Knox, and Giddings equations provides insights into the column physical structures. Separation quality for both shapes was evaluated across differences in fiber packing density, gradient rate, and mobile phase linear velocity for the reversed phase separation of a four protein mixture, containing ribonuclease A, cytochrome c, lysozyme, and myoglobin. The results of this study lay the ground work for future efforts in the use of trilobal fibers for the separation of biomacromolecules.  相似文献   

6.
The effect of combining sub-2 microm porous particles with elevated operating temperatures on chromatographic performance has been investigated in terms of chromatographic efficiency, productivity, peak elution order, and observed operating pressure. The use of elevated temperature in LC does not increase the obtainable performance but allows the same performance to be obtained in less time. Increasing the column temperature did allow the use of longer columns, generating column efficiencies in excess of 100,000 plates and gradient peak capacities approaching 1000. Raising the temperature increased the optimal mobile phase linear velocity, negating somewhat the pressure benefits observed by reducing the solvent viscosity. When operating at higher temperature the analyte retention is not only reduced, but the order of elution will also often change. High temperature separations allowed exotic organic modifiers such as isopropanol to be exploited for alternative selectivity and faster analysis. Finally, care must be taken when using high temperature separations to ensure that the narrow peak widths produced do not compromise the quality of data obtained from detectors such as high resolution mass spectrometers.  相似文献   

7.
A rapid and selective HPLC method using monolithic columns was developed for the separation and quantification of the principal amphetamines in ecstasy tablets. Three monolithic (Chromolith RP18e) columns of different lengths (25, 50 and 100 mm) were assessed. Validation studies including linearity, selectivity, precision, accuracy and limit of detection and quantification were carried out using the Chromolith SpeedROD, RP-18e, 50 mm x 4.6 mm column. Column backpressure and van Deemter plots demonstrated that monolithic columns provide higher efficiency at higher flow rates when compared to particulate columns without the loss of peak resolution. Application of the monolithic column to a large number of ecstasy tablets seized in Ireland ensured its suitability for the routine analysis of ecstasy tablets.  相似文献   

8.
We investigated the achievable separation performance of a 9-cm-long and 1-mm-wide pillar array channel (volume = 0.6 μL) containing 5 μm diameter Si pillars (spacing 2.5 μm) cladded with a mesoporous silica layer with a thickness of 300 nm, when this channel is directly interfaced to a capillary LC instrument. The chip has a small footprint of only 4 cm × 4 mm and the channel consists of three lanes that are each 3 cm long and that are interconnected using low dispersion turns consisting of a narrow U-turn (10 μm), proceded and preceded by a diverging flow distributor. Measuring the band broadening within a single lane and comparing it to the total channel band broadening, the additional band broadening of the turns can be estimated to be of the order of 0.5 μm around the minimum of the van Deemter curve, and around some 1 μm (nonretained species) and 2 μm (retained species) in the C-term dominated regime. The overall performance (chip + instrument) was evaluated by conducting gradient elution separations of digests of cytochrome c and bovine serum albumin. Peak capacities up to 150 could be demonstrated, nearly completely independent of the flow rate.  相似文献   

9.
The experimental effects of sampling time on the resolving power of on-line LC×LC were investigated. The first dimension gradient time ((1)t(g)) and sampling time (t(s)) were systematically varied ((1)t(g)=5, 12, 24 and 49 min; t(s)=6, 12, 21 and 40s). The resolving power of on-line LC×LC was evaluated in terms of two metrics namely the numbers of observed peaks and the effective 2D peak capacities obtained in separations of extracts of maize seeds. The maximum effective peak capacity and number of observed peaks of LC×LC were achieved at sampling times between 12 and 21s, at all first dimension gradient times. In addition, both metrics showed that the "crossover" time at which fully optimized 1DLC and LC×LC have equal resolving power varied somewhat with sampling time but is only about 5 min for sampling times of 12 and 21s. The longest crossover time was obtained when the sampling time was 6s. Furthermore, increasing the first dimension gradient time gave large improvements in the resolving power of LC×LC relative to 1DLC. Finally, comparisons of the corrected and effective 2D peak capacities as well as the number of peaks observed showed that the impact of the coverage factor is quite significant.  相似文献   

10.
Stoll DR  Li X  Wang X  Carr PW  Porter SE  Rutan SC 《Journal of chromatography. A》2007,1168(1-2):3-43; discussion 2
The absolute need to improve the separating power of liquid chromatography, especially for multi-constituent biological samples, is becoming increasingly evident. In response, over the past few years, there has been a great deal of interest in the development of two-dimensional liquid chromatography (2DLC). Just as 1DLC is preferred to 1DGC based on its compatibility with biological materials we believe that ultimately 2DLC will be preferred to the much more highly developed 2DGC for such samples. The huge advantage of 2D chromatographic techniques over 1D methods is inherent in the tremendous potential increase in peak capacity (resolving power). This is especially true of comprehensive 2D chromatography wherein it is possible, under ideal conditions, to obtain a total peak capacity equal to the product of the peak capacities of the first and second dimension separations. However, the very long timescale (typically several hours to tens of hours) of comprehensive 2DLC is clearly its chief drawback. Recent advances in the use of higher temperatures to speed up isocratic and gradient elution liquid chromatography have been used to decrease the time needed to do the second dimension LC separation of 2DLC to about 20s for a full gradient elution run. Thus, fast, high temperature LC is becoming a very promising technique. Peak capacities of over 2000 and rates of peak capacity production of nearly 1 peak/s have been achieved. In consequence, many real samples showing more than 200 peaks with signal to noise ratios of better than 10:1 have been run in total times of under 30 min. This report is not intended to be a comprehensive review of 2DLC, but is deliberately focused on the issues involved in doing fast 2DLC by means of elevating the column temperature; however, many issues of broader applicability will be discussed.  相似文献   

11.
Today sub-2 μm packed columns are very popular to conduct fast chromatographic separations. The mass-transfer resistance depends on the particle size but some practical limits exist not to reach the theoretically expected plate height and mass-transfer resistance. Another approach applies particles with shortened diffusion path to enhance the efficiency of separations. In this study a systematical evaluation of the possibilities of the separations obtained with 5 cm long narrow bore columns packed with new 2.6 μm shell particles (1.9 μm nonporous core surrounded by a 0.35 μm porous shell, Kinetex™, Core-Shell), packed with other shell-type particles (Ascentis Express™, Fused-Core), totally porous sub-2 μm particles and a 5 cm long narrow bore monolith column is presented. The different commercially available columns were compared by using van Deemter, Knox and kinetic plots. Theoretical Poppe plots were constructed for each column to compare their kinetic performance. Data are presented on polar neutral real-life analytes. Comparison of a low molecular weight compounds (MW = 270–430) and a high molecular weight one (MW ∼ 900) was conducted. This study proves that the Kinetex column packed with 2.6 μm shell particles is worthy of rivaling to sub-2 μm columns and other commercially available shell-type packings (Ascentis Express or Halo), both for small and large molecule separation. The Kinetex column offers a very flat C term. Utilizing this feature, high flow rates can be applied to accomplish very fast separations without significant loss in efficiency.  相似文献   

12.
To contribute to the current debate about the "ideal" particle size range (sub-2mum vs. supra-2mum), the present study compares the kinetic performance of some commercially available sub-2mum and 3.5mum particles used under quasi-adiabatic conditions via the kinetic plot method. Under the adopted assumption that viscous heating effects can be neglected (which is uncertain in a pressure range above 400bar), the obtained kinetic plots show that, provided each particle size is used in a column with properly optimized length, the gain in separation speed that sub-2mum particle columns might have over maximally performing 2.5mum particle columns is very small. Sub-2mum particle columns can only yield a gain in separation speed in the range of high-speed/low-resolution-separations (total time based on k=10 below 5 or 10min). And even in this range, the actual gain that can be expected is only marginally small (only a few %). The present study hence suggests that the development and the use of particles in the 2-3mum range should deserve more attention than it did in the past few years. However, to be competitive, this 2-3mum material should be packed in relatively long columns, with a packing quality matching that of the current best performing 3.5mum particle columns. The supra-2mum particles should also be able to withstand the same pressures as the sub-2mum particle material one is comparing it to.  相似文献   

13.
Fast analysis in LC can be performed with sub-2 microm particles at very high pressures (up to 1000 bar) known as ultra performance LC (UPLC). With this configuration, it is possible to obtain fast and/or highly efficient separations compared to conventional LC. For the analysis of compounds without chromophores, the evaporative light scattering detector (ELSD) is an attractive alternative because of its quasi-universality, versatility, low-cost and good sensitivity. The UPLC-ELSD was investigated in terms of sensitivity and apparent efficiency, with a conventional ELSD instrument, for two types of commercially available nebulisers, using different mobile phase flow rates and column ids. Results were finally compared with the UPLC-UV configuration. Three applications with phytochemical compounds were selected to highlight the potential of this approach (i.e. the isocratic separations of artemisinin and its derivatives, of calystegines and the gradient separation of several tropane alkaloids). Depending on the used column length, baseline separations were obtained in 3-10 min, with an average apparent efficiency ranging from 7000 to 30,000 plates.  相似文献   

14.
Reversed-phase ultra-performance liquid chromatography was used for biopolymer separations in isocratic and gradient mode. The gradient elution mode was employed to estimate the optimal mobile phase flow rate to obtain the best column efficiency and the peak capacity for three classes of analytes: peptides, oligonucleotides and proteins. The results indicate that the flow rate of the Van Deemter optimum for 2.1 mm I.D. columns packed with a porous 1.7 microm C18 sorbent is below 0.2 mL/min for our analytes. However, the maximum peak capacity is achieved at flow rates between 0.15 and 1.0 mL/min, depending on the molecular weight of the analyte. The isocratic separation mode was utilized to measure the dependence of the retention factor on the mobile phase composition. Constants derived from isocratic experiments were utilized in a mathematical model based on gradient theory. Column peak capacity was predicted as a function of flow rate, gradient slope and column length. Predicted peak capacity trends were compared to experimental results.  相似文献   

15.
A practical evaluation of the possibilities and limitations of ultra performance liquid chromatography (UPLC) is presented. Acquity BEH columns packed with 1.7 microm particles are evaluated by means of van Deemter and Knox plots. The columns are characterised by high optimal velocities (3.7 mm/s) and low plate heights (4.4 microm). Minimum plate heights of 2d(p) were, however, not reached and reasons are presented and discussed. Furthermore, the use of 1.7 microm particles at 1000 bar is compared, from a theoretical viewpoint, to conventional LC (3.5 and 5 microm particles at 400 bar) in terms of analysis speed and practical maximum efficiency. Experimental data are used to construct kinetic- or "Poppe-plots", which facilitate investigation of the effect of pressure and particle size on speed and efficiency. It is found that UPLC conditions hold advantages in terms of speed of analysis, for required theoretical plate counts up to approximately 80,000.  相似文献   

16.
Ultralow flow LC employs ultra-narrow bore columns and mid-range pL/min to low nL/min flow rates (i.e., ≤20 nL/min). The separation columns that are used under these conditions are typically 2–30 μm in inner diameter. Ultralow flow LC systems allow for exceptionally high sensitivity and frequently high resolution. There has been an increasing interest in the analysis of scarce biological samples, for example, circulating tumor cells, extracellular vesicles, organelles, and single cells, and ultralow flow LC was efficiently applied to such samples. Hence, advances towards dedicated ultralow flow LC instrumentation, technical approaches, and higher throughput (e.g., tens-to-hundreds of single cells analyzed per day) were recently made. Here, we review the types of ultralow flow LC technology, followed by a discussion of selected representative ultralow flow LC applications, focusing on the progress made in bioanalysis of amount-limited samples during the last 10 years. We also discuss several recently reported high-sensitivity applications utilizing flow rates up to 100 nL/min, which are below commonly used nanoLC flow rates. Finally, we discuss the path forward for future developments of ultralow flow LC.  相似文献   

17.
A simple method to correct the measured extent of band broadening in size exclusion chromatography for the contribution of narrow (polydisperse) standards is presented. It is based on the assumptions that commercial polymer standards can be described by a Poisson distribution and the additivity of peak variances. Two sets of standards (polystyrene from two suppliers) were investigated under normal working conditions, i.e. a combination of four columns with different porosities and a flow rate of 1 ml/min. Furthermore, the polystyrene standards were used to determine the extent of band broadening for four additional combinations of columns (varying in their separation range and porosities) as a function of the elution volume. The assumption of a constant peak variance for band broadening turned out to be a (very) rough approximation for some combinations of columns, but all results taken together demonstrate that this assumption is not generally applicable. Qualitative agreement between theory and experiment was found with a rearranged van Deemter equation.  相似文献   

18.
用气相色谱法测定了苯、甲苯和乙苯在固定液低密度聚乙烯中的保留时间和半峰宽,运用vanDeemter模型进行数据处理,得到3种芳烃小分子在低密度聚乙烯膜材料中的无限稀释扩散系数.  相似文献   

19.
This HPLC tutorial focuses on the preparation and use of kinetic plots to characterise the performance in isocratic and gradient LC. This graphical approach allows the selection of columns (i.e. optimum particle size and column length) and LC conditions (operating pressure and temperature) to generate a specific number of plates or peak capacity in the shortest possible analysis time. Instrument aspects including the influence of extra-column effects (maximum allowable system volume) and thermal operating conditions (oven type) on performance are discussed. In addition, the performance characteristics of porous-shell particle-packed columns and monolithic stationary phases are presented and the potential of future column designs is discussed.  相似文献   

20.
In this study, the performance of monolithic columns was evaluated for ultrafast liquid chromatography/mass spectrometry (LC/MS) analyses and for high-resolution separations of several azaspiracid biotoxin analogs. Because of their high permeability, monolithic columns offer a number of advantages over conventional packed columns; viz., very low backpressures and relatively flat van Deemter curves at high flow rates. That is, very high flow rates can be used for ultrafast analyses or, by using longer than normal columns, high-resolution separations are possible. In a series of experiments, we varied the mobile phase flow rates between 1 and 8 mL/min, and studied their impact on chromatographic parameters such as retention time, resolution, number of plates and pressure. The chromatographic run times could be reduced to ca. 30 s without a significant change in the separation efficiency. A signal intensity comparison revealed interesting differences between atmospheric-pressure chemical ionization (APCI) and electrospray ionization (ESI) in their flow-rate dependency. An explanation with respect to the behavior as of a mass-flow or a concentration-dependent device is given in the paper. Additionally, the column length was varied between 10 and 70 cm. As a result, the number of theoretical plates increased substantially. In the example shown in the report, an increase from 13 000 plates for a 10-cm column to 80 000 for a 70-cm column is demonstrated. In addition, the potential of the monolithic columns for high-resolution LC/MS separations is shown for a complex biotoxin mixture, which was separated on a 40-cm-long column.  相似文献   