首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Low-molecular-mass fluorescent compounds excitable in the near UV region with suitable acidobasic and electrophoretic properties are suggested as isoelectric point (pI) markers for isoelectric focusing (IEF) with UV photometric and UV excited fluorometric detection. The experimental set-up of capillary IEF with UV excited fluorometric detection and properties of new UV-induced fluorescent pI markers are given. The pI values of 18 new pI markers determined independently of IEF methods range from 2.1 to 10.3. The examples of separation of new pI markers together with derivatized proteins by capillary IEF with photometric or fluorometric detection are presented.  相似文献   

2.
Colored, low molecular weight pI markers have been developed for isoelectric focusing (IEF) in acidic pH range. Their isoelectric points (pIs) were determined by direct measurement of the pH of the focused bands after completion of IEF on polyacrylamide gels. The practicable suitability of the proposed pI markers as pI standards for IEF was tested by applying gel IEF. The acidic pH gradient was created either by commercial synthetic carrier ampholytes or by mixture of simple buffers consisting of acids (non-ampholytes) and ampholytic buffers. By applying simple acids, it was possible to extend the acidic pH range beyond those achievable with commercial synthetic carrier ampholytes. By using an experimental arrangement without electrode electrolyte reservoirs with electrodes creating the fixed end of the gel, the strongly acidic pH gradient was stable even for prolonged focusing time.  相似文献   

3.
Jin Y  Luo G  Oka T  Manabe T 《Electrophoresis》2002,23(19):3385-3391
Synthetic UV-detectable peptide pI markers were used to estimate isoelectric point (pI) values of proteins separated by capillary isoelectric focusing (CIEF) followed by cathodic mobilization in the absence of denaturing agents. The pI calculation and quantitative analysis of purified proteins showed the feasibility of these peptides as pI markers and internal standards in CIEF separation of proteins. Estimation of pI values of major proteins in human plasma was performed using the peptide pI markers, and the values were compared with those previously obtained by gel isoelectric focusing (IEF). Sera of immunoglobulin G (IgG) myeloma patients, which showed characteristic peaks of myeloma IgG in their CIEF patterns, were also subjected to the analysis and the pI values of the myeloma proteins have been estimated.  相似文献   

4.
An isoelectric point (pI) calibration kit containing fish muscle parvalbumins was prepared and tested for its suitability for isoelectric focusing (IEF) in the presence of 8 M urea. The pattern obtained by urea CleanGel IEF consisted of nine bands covering the pI range 4.96-5.64. This range is relevant for species identification of heated fish by urea IEF. The kit may also be used for native IEF in the low pH range, as demonstrated by running an extract made from the kit together with water-soluble fish muscle proteins on Servalyt Precotes 3-6.  相似文献   

5.
Stastná M  Slais K 《Electrophoresis》2005,26(18):3586-3591
Two-dimensional gel isoelectric focusing (2-D gel IEF) is presented as the combination of the same separation method used consecutively in two directions of the same gel. In this new method, after completion of IEF process in the first dimension the gel was cut into the separate strips, each containing selected analytes together with the appropriate part of the original broad pH gradient, and the strips were rotated by 90 degrees (with regard to the first IEF) and left to diffuse overnight. After diffusion the strips were subjected to the second IEF. During the second IEF, the corresponding narrow part of pH gradient in each strip was restored again, however, now along the strip. The progress of the separation process can be monitored visually by using colored low-molecular-weight isoelectric point (pI) markers loaded into the gel simultaneously with proteins. The unique properties of IEF, focusing and resolution power were enhanced by using the same technique twice. Two forms of beta-lactoglobulin (pI values 5.14 and 5.31, respectively) non-separated in the first IEF were successfully separated in the second dimension at relatively low voltage (330 V) with the resolution power comparable to the high-resolution gels requiring the high voltage during the run and long separation time. Glucose oxidase loaded as diluted solution into ten positions across the gel was finally focused into a single band during 2-D gel IEF. Since the first and second IEF are carried out on the same gel, no losses and contamination of analyte occur. The suggested method can be used for separation/fractionation of complex biological mixtures, similarly as other multidimensional separation techniques applied in proteomics, and can be followed by further processing, e.g., mass spectrometry analysis. The focusing properties of IEF could be useful especially in separation of mixtures, where components are at low concentration levels.  相似文献   

6.
Sixteen peptides (trimers to hexamers) were designed for use as a set of pI markers for capillary isoelectric focusing (CIEF). Each peptide contains one tryptophan residue for detection by UV absorption and other amino acid residues having ionic side chains, which are responsible for focusing to its pI. The pIs of these peptides were determined by slab-gel IEF using commercial carrier ampholytes. The focused peptides in the gel were detected by absorption measurement at 280 nm using a scanning densitometer and the pH gradient was determined by measuring the pH of the gel using an oxidized metal membrane electrode. The pI values of the peptides ranged from 3.38 to 10.17. The obtained values agreed well with the predicted ones, which were calculated based on amino acid compositions, with root mean square differences of 0.15 pH unit. The peptides were detected at 280 nm as very sharp peaks when separated by CIEF. The pI values of some standard proteins were redetermined by CIEF by using this set of peptide pI markers and the values agreed closely with those reported previously. The sharp focusing, stability, high purity and high solubility of these synthetic pI markers should facilitate the profiling of a pH gradient in a capillary and the determination of the pI values of proteins.  相似文献   

7.
We prepared a series of low-molecular-mass fluorescent ampholytes with narrow pI range. These fluorescein-based ampholytes are detection compatible with argon laser-induced fluorescence (LIF) detection. The selected properties, important for their routine use as fluorescent pI markers, were examined. The pI values of new fluorescein-based pI markers were determined by capillary isoelectric focusing (CIEF) using currently available low-molecular-mass pI markers for CIEF with photometric detection. The examples of CIEF with fluorometric detection of new compounds together with fluorescein isothiocyanate (FITC) derivatized proteins are presented.  相似文献   

8.
Sample preparation is often necessary to separate and concentrate various compounds prior to analysis of complex samples. In this regard, isoelectric focusing (IEF) is one of the best sample preparation methods. With this approach, however, carrier ampholytes have to be introduced into the samples, which may result in matrix interferences. In this paper, a simple ampholyte-free IEF free-flow electrophoresis design was developed for the separation of proteins. beta-Lactoglobulin, hemoglobin, myoglobin and cytochrome c were selected as model analytes. The experimental design took advantage of the electrolysis-driven production of H(+) and OH(-) ions that migrated from the anode and cathode, respectively, establishing a pH gradient spanning from 2.3 to 8.9. The separation chamber was filled with silanized glass beads as a support medium. Dialysis membranes were mounted at the two sides of the separation chamber (made of glass slides) and sealed with 2% agarose gel. The separated proteins drained from the outlets of the separation chamber and could be successfully collected into small glass tubes. The focusing process was visually observed and the separation was confirmed by capillary isoelectric focusing (cIEF) with pI markers.  相似文献   

9.
Different ways of determining isoelectric points (pI) of proteins in capillary isoelectric focusing are reviewed here. Due to the impossibility of direct pH measurements in the liquid phase, such assessments have to rely on the use of pI markers. Different types of pI markers have been described: dyes, fluorescently labelled peptides, sets of proteins of known pI values. It appears that, perhaps, the best system is a set of 16 synthetic peptides, trimers to hexamers, made to contain each a Trp residue for easy detection at 280 nm. By a careful blend of acidic (Asp, Glu), mildly basic, with pK around neutrality (His), and basic (Lys, Arg) amino acids, it is possible to obtain a series of pI markers with pI values quite evenly distributed along the pH scale, possessing good buffering capacity and conductivity around their pI values and thus focusing as sharp peaks. Another approach to pI determination is the monitoring of the current during mobilization: this allows, with the aid of known pI markers, to calibrate the system with a pI/current graph. Pitfalls and common errors in pI determinations are reviewed here and guidelines given for minimizing such errors in pI estimation.  相似文献   

10.
Investigation of isoelectric focusing (IEF) kinetics has been performed to provide the theoretical basis for miniaturization of classical IEF in immobilized pH-gradients. Standard IEF demands colinearity of the electric field and pH-gradient directions (serial devices). It is shown that the IEF separation process based on a continuous, serial pH gradient is incompatible with miniaturization of separation devices. The new realization of the IEF device by a parallel IEF chip is suggested and analyzed. The main separation tool of the device is a dielectric membrane (chip) with conducting channels that are filled by Immobiline gels of varying pH. The membrane is held perpendicular to the applied electric field and proteins are collected (trapped) in the channels whose pH are equal to the pI of the proteins. The pH value of the surrounded aqueous solution is not equal to any channel's pH. The fast particle transport between different channels takes place due to convection in the aqueous solution. The new device geometry introduces two new spatial scales to be considered: the scale of transition region from a solution to the gel in a channel and a typical channel size. The corresponding time scales defining the IEF process kinetics are analyzed and scaling laws are obtained. It is shown both theoretically and experimentally that parallel IEF accelerates the fractionation of proteins by their pI down to several minutes and enables possible efficient sample collection and purification.  相似文献   

11.
A new protein fractionation technique based on off-gel isoelectric focusing (IEF) is presented, where the proteins are separated according to their isoelectric point (pI) in a multiwell device with the advantage to be directly recovered in solution for further analysis. The protein fractions obtained with this technique have then been characterized with polymer nanoelectrospray for mass spectrometry (MS) analyses or with Bioanalyzer for mass identification. This methodology shows the possibility of developing alternatives to the classical two-dimensional (2-D) gel electrophoresis. One species numerical simulation of the electric field distribution during off-gel separation is also presented in order to demonstrate the principle of the purification. Experiments with pI protein markers have been carried out in order to highlight the kinetics and the efficiency of the technique. Moreover, the resolution of the fractionation was shown to be 0.1 pH unit for the separation of beta-lactoglobulin A and B. In addition, the isoelectric fractionation of an Escherichia coli extract was performed in standard solubilization buffer to demonstrate the performances of the technique, notably for proteomics applications.  相似文献   

12.
A divergent-flow isoelectric focusing (DF IEF) technique has been applied for the separation and preparative analysis of peptides. The parameters of the developed DF IEF device such as dimension and shape of the separation bed, selection of nonwoven material of the channel, and separation conditions were optimized. The DF IEF device was tested by the separation of a peptide mixture originating from the tryptic digestion of BSA, cytochrome c, and myoglobin. The pH gradient of DF IEF was created by the autofocusing of tryptic peptides themselves without any addition of carrier ampholytes. The focusing process was monitored visually using colored pI markers, and the obtained fractions were analyzed by RP-HPLC and ESI/TOF-MS. DF IEF operating in the autofocusing mode provides an efficient preseparation of peptides, which is comparable with a commercially available MicroRotofor multicompartment electrolyzer and significantly improves sequence coverage of analyzed proteins. The potential of the DF IEF device as an efficient tool for the preparative scale separations was demonstrated by the isolation of caseinomacropeptide (CMP) from a crude whey solution.  相似文献   

13.
We studied the effects of fluorescent labeling on the isoelectric points (pI values) of proteins using capillary isoelectric focusing with laser-induced fluorescence detection (cIEF-LIF). Specifically, we labeled green fluorescent protein (GFP) from the jellyfish Aequorea victoria with the fluorogenic dye 3-(2-furoyl)quinoline-2-carboxaldehyde (FQ). cIEF-LIF was used to monitor the native fluorescence of GFP and showed pI changes in GFP's FQ-labeled products. Multiple labeling of GFP with FQ produced a series of products with pI values shifted towards a low pH. We verified cIEF-LIF results with traditional slab gel IEF. Our cIEF-LIF technique can routinely detect 10(-11) M of FQ-labeled protein, whereas traditional slab gel IEF with silver stain detection gives detection limits of 10(-7) M in the same samples.  相似文献   

14.
For the first time, the application of a commercial Shimadzu microchip electrophoresis system MCE-2010 equipped with an imaging UV detector for isoelectric focusing (IEF) of therapeutic proteins is reported. By proper adjustment of the pH gradient, samples with pI values ranging from 2.85 to 10.3 can be focused to the imaged part of the separation channel. Three therapeutic proteins (hirudin, erythropoietin, and bevacizumab) have been successfully focused on the microchip, and the results have been compared to conventional capillary IEF in terms of peak profile, pI values, and reproducibility.  相似文献   

15.
Slais K 《Electrophoresis》2008,29(12):2451-2457
Continuous-flow isoelectric focusing (IEF) has the potential to be an important method in proteome analysis. The current devices do not fully use the advantages of IEF, because they do not utilize all its important features including changes in background conductivity during the focusing. A novel continuous-flow IEF method has been developed based on planar divergent flow and control of local electric field by conductivity of electrode electrolytes. A hydrophilized polypropylene nonwoven fabric was used for creation of flow and electric manifold, making the assembled device cheap, flexible and easy to set up and operate. By using the colored low-molecular-weight pI markers we demonstrated much higher speed of focusing in the new designed channel in comparison with a channel based on currently used rectangular geometry. The developed divergent-flow IEF combines the speed of micro flow channels with the separation efficiency and sample load capacity of preparative devices.  相似文献   

16.
The isoelectric focusing (IEF) properties of human alpha 2-macroglobulin (alpha 2M) and alpha 2M-proteinase complexes from crude and partially purified preparations were studied by column IEF. The average isoelectric point (pI) of the major form was 6.5 for alpha 2M from crude plasma but was 5.3 for purified samples. Following preincubation with either trypsin, chymotrypsin or pancreatic elastase the crude alpha 2M-proteinase complexes displayed pI values ranging from 5.3 to 6.1 and the purified alpha 2M-proteinase complexes ranged from pH 6.0 to 6.1. A comparison of recoveries for focused crude or purified alpha 2M and trypsin-preincubated alpha 2M indicated enhanced recovery for the trypsin-preincubated samples suggesting that the binding of the proteinase enhances the stability of alpha 2M. alpha 2M thus displays column IEF properties which appear to be dependent upon the state of purity of the molecule. These findings are of particular significance to investigators concerned with using expressions of altered alpha 2M electrophoretic patterns for clinical diagnostic purposes in such diseases as multiple sclerosis, diabetes and cystic fibrosis.  相似文献   

17.
pH-biased isoelectric trapping separations are hindered by the lack of suitable isoelectric buffers with pI values in the 5.8 < pI range. Two generic approaches are described here for the cost-effective synthesis of a family of diamino sulfate buffers that have high buffering capacities in their isoelectric state: the first approach relies on the sulfation of existing, commercially available diamino alcohol intermediates, the second approach calls for the synthesis of diamino alcohols from epichlorohydrin and widely available secondary amines, and subsequent sulfation of the new diamino alcohol. The diamino sulfate buffers are recovered in isoelectric state, in high purity. Four members of the family having pI values in the 5.8 < pI < 8.9 range have been synthesized, analytically characterized by capillary electrophoresis (CE), electrospray ionization-time of flight-mass spectrometry (ESI-TOF-MS), 1-D and 2-D nuclear magnetic resonance (NMR) spectroscopy, and X-ray crystallography. All four diamino sulfates have been successfully used as pH biasers in the receiving stream in preparative-scale pH-biased isoelectric trapping protein separations.  相似文献   

18.
North RY  Vigh G 《Electrophoresis》2008,29(5):1077-1081
The operational pH value of a buffering membrane used in an isoelectric trapping separation is determined by installing the membrane as the separation membrane into a multicompartmental electrolyzer operated in the two-separation compartment configuration. A 3相似文献   

19.
The use of low-molecular-mass color pI markers for the determination of pI values of proteins in gel isoelectric focusing (IEF) in combination with mass spectrometry is described. Different types of substituted phenols of known pI values within the mass range 250-400 were used here as pI markers. The pure, synthesized pI markers were studied by MALDI-TOF/TOF MS. Fragmentation studies of the pI markers were also performed. Only stable and well-characterized pI markers were used in this work. The selected pI markers were mixed with proteins, deposited on a gel and separated in a pH gradient. Color pI markers enable supervision of progress of the focusing process and also estimation of the position of the invisible focused bands. The separated bands of the pI markers (containing separated proteins) were excised, and the pI markers were eluted from each gel piece by water/ethanol and identified by MALDI-TOF/TOF MS. From the washed gel pieces the remaining carrier ampholytes were then washed out and proteins were in-gel digested with trypsin. The obtained peptides were measured by MALDI-TOF/TOF MS and the proteins identified via a protein database search. This procedure allows avoiding time-consuming protein staining and destaining procedures, which shortens the analysis time roughly by half. For comparison, IEF gels were stained with Coomassie Brilliant Blue R 250 and proteins in the gel bands were identified according to the standard proteomic protocol. This work has confirmed that our approach can give information about the correct pI values of particular proteins and shorten significantly the time of analysis.  相似文献   

20.
A robust and highly reproducible capillary isoelectric focusing (cIEF) method for the evaluation of charge heterogeneity of monoclonal antibody (mAb) pharmaceutical which contains covalently bound antitumor compounds was developed using a combination of commercially available dimethylpolysiloxane-coated capillary and carrier ampholyte. In order to optimize major analytical parameters for robust mobilization, experimental responses from three pI markers were selected. The optimized method gave excellent repeatability and intermediate precision in estimated pI values of charge variants with relative standard deviations (RSDs) of not more than 0.06% and 0.95%, respectively, when using IgG(4) as a model. Furthermore, RSDs of charge variant compositions were less than 5.0%. These results suggest that the proposed method can be a powerful tool for reproducible evaluation of charge variants of both naked mAbs and their conjugates with high resolution, and it is applicable to quality testing and detailed characterization in the pharmaceutical industry. In addition, it should be noticed that the method provided non-linear pH gradient within the tested ranges, from pI 9.50 to 3.78, and the pH gradient caused the inconsistency of estimated pI ranges between cIEF and gel IEF. This result indicates that selecting appropriate pI markers based on the target pI ranges of charge variants for each mAb related pharmaceutical is highly recommended for the precise determination of pI values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号