首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Johns C  Macka M  Haddad PR 《Electrophoresis》2000,21(7):1312-1319
The use of highly absorbing anionic dyes as probes and isoelectric ampholytes as buffers in background electrolytes (BGEs) combined with the use of a light emitting diode (LED) as a light source has been studied for ultrasensitive indirect photometric detection in capillary electrophoresis (CE). Potential dyes and buffers were evaluated based on characteristics relevant to indirect photometric detection principles, such as the electrophoretic mobility of the probe dye, its solubility and adsorption behaviour, and the isoelectric point and buffering capacity of the ampholytic buffer. Two dyes, tartrazine and naphthol yellow S, and histidine as the ampholytic buffer, were selected for detailed investigation. Purification of the probes was vital to avoid anionic impurities interfering with the detection. For the electrolytes containing a purified probe (0.5 mM) and histidine as the isoelectric buffer (p/ 7.7), hydroxypropylmethyl cellulose (approximately 0.05%) was effective in suppression of the electroosmotic flow (EOF). Analytical method performance characteristics were determined. For both probes, experimentally determined mobilities were generally close to literature values, excellent peak shapes and separation efficiencies of up to 298 000 theoretical plates were obtained, and detection limits were generally at the sub-microM level. For the naphthol yellow S-histidine BGE, linearity and reproducibility were also evaluated, with excellent linearity being observed over a range of 5-500 microM, and reproducibility (relative standard deviation, RSD) less than 1% for migration times and 2-8% for normalised peak areas. The approach developed was applied successfully to several real samples including tap water, mineral waters, and beer.  相似文献   

2.
Two capillary isoelectric focusing (CIEF) systems have first been optimized: one uses a bare silica capillary and 30% (v/v) of glycerol in the separation medium while the other uses a coated capillary and an aqueous background electrolyte. To perform permanent capillary coating, two neutral polymers have been compared: hydroxypropylcellulose (HPC) and polyvinylalcohol (PVA). HPC coating gave best results for electroosmotic flow (EOF) limitation on a wide pH range: as compared to a bare silica capillary, it allowed to decrease EOF by 96% at pH 7.2 after acidic and basic treatments, whereas PVA coating lead only to a 76% decrease. The glycerol CIEF system was more satisfying for the separation of model proteins classically used as pI markers. Finally, the use of "narrow pH cuts" of carrier ampholytes added to commercial ampholyte mixtures allowed increasing resolution up to a factor 2.4 at a chosen pH for the separation of pI markers and milk proteins.  相似文献   

3.
In this study, positively charged alkylaminosilyl monomers were used to modify the inner surface of fused silica capillaries, which subsequently were employed in capillary electrophoresis (CE) and capillary electrochromatography (CEC). The obtained surfaces yield a reversed electroosmotic flow (EOF) and have varying carbon chain lengths, that interact with the analytes and give chromatographic retention. The coating procedure is very simple and fast. The performance of the modified capillaries was evaluated regarding pH influence on EOF and chromatographic interactions. The experiments were conducted with UV and mass spectrometry (MS) and applied to the separation of various neuropeptides. The derivatized surfaces showed a linear (R(2) approximately 0.99) pH dependence with isoelectric points (pI) at 8.6-8.8. Rapid separations of peptide standards and a protein digest with efficiencies as high as 5 x 10(5) plates/m were performed.  相似文献   

4.
North RY  Vigh G 《Electrophoresis》2008,29(5):1077-1081
The operational pH value of a buffering membrane used in an isoelectric trapping separation is determined by installing the membrane as the separation membrane into a multicompartmental electrolyzer operated in the two-separation compartment configuration. A 3相似文献   

5.
A multi-chamber apparatus for preparative isoelectric focusing is described. The apparatus is constructed of 32 separation chambers and 2 electrode chambers, all separated by uncharged porous membranes. The total volume of the 32 separation chambers is 660 mL. A cooling system and a stirring system are built in. Human serum proteins were separated by isoelectric focusing in a natural pH gradient. The fractionation was monitored by fused rocket immunoelectrophoresis. The number of proteins in each fraction was monitored by crossed immunoelectrophoresis. The apparent pI values of IgG, transferrin and alpha-1-antitrypsin are as found in the literature. Orosomucoid (alpha-1-acid glycoprotein) (pI = 1.8) is concentrated at the acid end of the pH gradient.  相似文献   

6.
Different ways of determining isoelectric points (pI) of proteins in capillary isoelectric focusing are reviewed here. Due to the impossibility of direct pH measurements in the liquid phase, such assessments have to rely on the use of pI markers. Different types of pI markers have been described: dyes, fluorescently labelled peptides, sets of proteins of known pI values. It appears that, perhaps, the best system is a set of 16 synthetic peptides, trimers to hexamers, made to contain each a Trp residue for easy detection at 280 nm. By a careful blend of acidic (Asp, Glu), mildly basic, with pK around neutrality (His), and basic (Lys, Arg) amino acids, it is possible to obtain a series of pI markers with pI values quite evenly distributed along the pH scale, possessing good buffering capacity and conductivity around their pI values and thus focusing as sharp peaks. Another approach to pI determination is the monitoring of the current during mobilization: this allows, with the aid of known pI markers, to calibrate the system with a pI/current graph. Pitfalls and common errors in pI determinations are reviewed here and guidelines given for minimizing such errors in pI estimation.  相似文献   

7.
Four acidic, isoelectric buffers, for peptide and protein separations, have been recently described and adopted in capillary zone electrophoresis: cysteic acid [Cys-A, isoelectric point (pI) 1.85], iminodiacetic acid (IDA, pI 2.23), aspartic acid (Asp, pI 2.77) and glutamic acid (Glu, pI 3.22). These four buffers allow to explore an acidic portion of the titration curves of macroions, covering about 1.6 pH units (from pH 1.85 to ca. 3.45), thus permitting resolution of compounds having coincident titration curves at a given pH value. Given the rather acidic pI values of these buffers, their long-term stability has been investigated, by monitoring pH and conductivity changes upon increasing storage times. When dissolved in plain water, all four buffers appear to give constant pH and conductivity readings up to 15 days; after that, the conductivity keeps steadily increasing in a similar fashion. The same parameters, when the same buffers are dissolved in 6 M urea, appear to be stable for only one week, with the conductivity progressively augmenting after this period. A similar behaviour is exhibited by histidine (pI 7.70), a neutral, isoelectric buffer adopted for separation of DNA fragments. By mass spectrometry, Cys-A shows minute amounts (ca. 1%) of a degradation product after ageing for 3 weeks; in the same time period, Glu is extensively degraded (20%). No degradation species could be detected in IDA and Asp solutions. It is additionally shown that the acidic buffers are not quite stationary in the electric field, but can be transported at progressively higher rates (according to the pI value) from the cathodic to the anodic vessel. This is due to the fact that, at their respective pI values, a fraction of the amphotere has to be negatively charged in order to provide counterions to the excess of protons due to bulk water dissociation. Guidelines are given for the proper use and storage of such buffers.  相似文献   

8.
pH-biased isoelectric trapping separations are hindered by the lack of suitable isoelectric buffers with pI values in the 5.8 < pI range. Two generic approaches are described here for the cost-effective synthesis of a family of diamino sulfate buffers that have high buffering capacities in their isoelectric state: the first approach relies on the sulfation of existing, commercially available diamino alcohol intermediates, the second approach calls for the synthesis of diamino alcohols from epichlorohydrin and widely available secondary amines, and subsequent sulfation of the new diamino alcohol. The diamino sulfate buffers are recovered in isoelectric state, in high purity. Four members of the family having pI values in the 5.8 < pI < 8.9 range have been synthesized, analytically characterized by capillary electrophoresis (CE), electrospray ionization-time of flight-mass spectrometry (ESI-TOF-MS), 1-D and 2-D nuclear magnetic resonance (NMR) spectroscopy, and X-ray crystallography. All four diamino sulfates have been successfully used as pH biasers in the receiving stream in preparative-scale pH-biased isoelectric trapping protein separations.  相似文献   

9.
The non-availability of commercial carrier ampholytes in the pH range greater than 11 has contributed to difficulties in focusing and resolving highly basic proteins/peptides using capillary isoelectric focusing (cIEF). Two different approaches, involving the use of N,N,N',N'-tetramethylethylenediamine (TEMED) and ampholyte 9-11, are investigated for their effects on the extension of separation range in cIEF. The addition of TEMED into pharmalyte 3-10 not only prevents the peptides/proteins from focusing in sections of the capillary beyond the detection point, but also extends the separation range to at least isoelectric point (pI) 12. The combination of ampholyte 9-11 with pharmalyte 3-10 surprisingly provides baseline resolution between bradykinin (pI 12) and cytochrome c (pI 10.3). The sample mixture, containing bradykinin, the high-pI protein calibration kit (pI 5.2-10.3), and cytochrome c digest, is employed to demonstrate the cIEF separation of proteins and peptides over a wide pH range of 3.7-12.  相似文献   

10.
A recirculating, preparative-scale isoelectric trapping device, developed for the binary isoelectric trapping separation of proteins has been used to desalt, isolate and enrich the pI<4 protein fraction from a 150 mL sample of bovine serum. Subsequent re-separation of the 2相似文献   

11.
The first use of plasma polymerization technique to modify the surface of a glass chip for capillary isoelectric focusing (cIEF) of different proteins is reported. The electrophoresis separation channel was machined in Tempax glass chips with length 70 mm, 300 microm width and 100 microm depth. Acetonitrile and hexamethyldisiloxane monomers were used for plasma polymerization. In each case 100 nm plasma polymer films were coated onto the chip surface to reduce protein wall adsorption and minimize the electroosmotic flow. Applied voltages of 1000 V, 2000 V and 3000 V were used to separate mixtures of cytochrome c (pI 9.6), hemoglobin (pI 7.0) and phycocyanin (pI 4.65). Reproducible isoelectric focusing of each pI marker protein was observed in different coated capillaries at increasing concentration 2.22-5 microg microL(-1). Modification of the glass capillary with hydrophobic HMDS plasma polymerized films enabled rapid cIEF within 3 min. The separation efficiency of cytochrome c and phycocyanin in both acrylamide and HMDS coated capillaries corresponded to a plate number of 19600 which compares favourably with capillary electrophoresis of neurotransmitters with amperometric detection.  相似文献   

12.
Low-molecular-mass fluorescent compounds excitable in the near UV region with suitable acidobasic and electrophoretic properties are suggested as isoelectric point (pI) markers for isoelectric focusing (IEF) with UV photometric and UV excited fluorometric detection. The experimental set-up of capillary IEF with UV excited fluorometric detection and properties of new UV-induced fluorescent pI markers are given. The pI values of 18 new pI markers determined independently of IEF methods range from 2.1 to 10.3. The examples of separation of new pI markers together with derivatized proteins by capillary IEF with photometric or fluorometric detection are presented.  相似文献   

13.
Shave E  Vigh G 《Electrophoresis》2007,28(13):2291-2299
The Biflow, a new isoelectric trapping instrument was designed to obtain a narrow DeltapI fraction from a complex feed in one step. The Biflow contains two identical separation units, each unit houses: an anode and cathode compartment, an anodic and cathodic membrane, an anodic and cathodic separation compartment, and a separation membrane. The separation units are connected to independent power supplies. The anodic membranes in Units 1 and 2 typically buffer at the same pH value and so do the cathodic membranes. The separation membranes in Units 1 and 2 buffer at different pH values, these determine the pI range (DeltapI) of the product. The cathodic separation compartments in Units 1 and 2 contain the feed and harvest streams. The two anodic separation compartments, connected through an electrically insulating air gap, form the transfer loop through which the transfer stream is recirculated between Units 1 and 2. Ampholytic components in the feed, with pI values lower than the pH of the buffering membrane in Unit 1, pass into the transfer stream and are shuttled into Unit 2. In Unit 2, components in the transfer stream which have pI values higher than the pH of the buffering membrane in Unit 2, pass into the harvest stream. This double transfer of the target component, oppositely directed, guarantees the complete exclusion of products outside the desired DeltapI range from the harvest stream. The utility of the Biflow unit was demonstrated by isolating carnosine from a mixture of UV-absorbing ampholytes and ovalbumin isoforms as well as 4.4 相似文献   

14.
Yeung KK  Atwal KK  Zhang H 《The Analyst》2003,128(6):566-570
The use of surfactants as additives was demonstrated for the first time in capillary isoelectric focusing (CIEF) to dynamically modify the surfaces of bare fused silica capillaries. These surfactants were zwitterionic sulfobetaines: dodecyldimethyl (3-sulfopropyl) ammonium hydroxide (C12N3SO3), hexadecyldimethyl (3-sulfopropyl) ammonium hydroxide (C16N3SO3) and coco (amidopropyl)hydroxyldimethylsulfobetaine (Rewoteric AM CAS U). They were added directly to the protein-ampholyte mixture, and remained in the capillary during isoelectric focusing and mobilization. The C16N3SO3 and CAS U coatings were shown effective in CEF. Separation of seven IEF protein standards was obtained, with significantly improved resolution compared to that from an uncoated silica capillary. The effect of these surfactants on the electroosmotic flow (EOF) in CIEF was determined. CAS U was effective in suppressing the EOF at neutral and alkaline pH conditions, C16N3SO3 was effective in suppressing EOF at acidic and neutral pH conditions. C12N3SO3 however had little effect on the EOF. The pH gradients formed inside these surfactant coated capillaries were recta-linear at pH 6 to 9 (R2 approximately equal to 0.99). Reproducibility of migration time and peak area was determined. For all three coatings, the migration time standard deviations were less than 1.6 min, and the relative standard deviations of area were below 10%. The protein recovery in the CAS U-modified capillary was quantitative or near-quantitative for five of the seven proteins studied.  相似文献   

15.
Capillary electrophoresis coupled with indirect UV absorbance detection was employed for the determination of the chemical warfare agent degradation products: methylphosphonic acid, ethyl methylphosphonate, isopropyl methylphosphonate, and pinacolyl methylphosphonate. Glutamic acid was used as a buffering agent at its isoelectric point (pH 3.22). In its zwitterionic form, glutamic acid does not act as a competing co-anion in the system, thus providing buffering capacity while maintaining high sensitivity. The indirect probe (phenylphosphonic acid) concentration was lowered to 1 mM from the 10 mM in previous literature studies, further enhancing sensitivity. Detection limits of 2 μM were achieved with hydrodynamic injection and up to 100-fold lower using electrokinetic injection. The increased buffering capacity of this system over previous methods led to migration time reproducibility RSD values of 0.18 to 0.22%. This represents a 10-fold improvement in reproducibility over previous studies with comparable or improved sensitivity.  相似文献   

16.
Lalwani S  Tutu E  Vigh G 《Electrophoresis》2005,26(10):2047-2055
Two approaches are described in this paper for the synthesis of isoelectric buffers that have pI values in the 1.5 < pI < 4.3 range. The first synthesis relies on the alkylation of existing aminodicarboxylic acids and recovery of the ampholyte as an inner salt. The second synthesis method forms low-pI ampholytes by reacting a secondary amine with two equivalents of an alkylester of a haloalkanecarboxylic acid, followed by hydrolysis of the intermediate in an alkaline solution and recovery of the ampholyte as an inner salt. The new ampholytes have been analytically characterized by capillary electrophoresis, high-resolution electrospray ionization-mass spectrometry, one- and two-dimensional nuclear magnetic resonance (NMR) spectroscopy, and X-ray crystallography. The isoionic solutions of the new ampholytes have high buffering capacity and conductivity, making them good pH biasers in the receiving stream in preparative-scale pH-biased isoelectric trapping separations.  相似文献   

17.
This study addresses the two major problems in the use of dyes as highly absorbing probes for indirect photometric detection in capillary electrophoresis (CE). First, effective electroosmotic flow (EOF) modification or suppression to allow separation and detection of a wide mobility range of analytes is not straightforward when electrolytes containing increased dye concentrations are used. The suppression of EOF to less than + 5x10(-9) m(2)V(-1)s(-1) was achieved with a combination of a poly(ethylenimine) (PEI)-coated capillary and the addition of the neutral polymer hydroxypropylmethylcellulose (HPMC) to the background electrolyte. Second, the deterioration of baselines due to adsorption of the dye probe to the capillary wall is generally a problem. In this work, baseline quality at higher probe concentrations was significantly improved by a rather unusual but highly effective combination of a simultaneous application of a slight overpressure (25 mbar) at the injection end during the separation, and the use of a relatively narrow capillary of 50 microm inner diameter. Both measures would appear to be counterproductive. Optimisation of the probe concentration with regard to signal-to-noise ratio resulted in an electrolyte of 4 mM Orange G, 0.05% HPMC buffered at pH 7.7 by the addition of 10.0 mM histidine isoelectric buffer. Very high separation efficiencies of 128 000-297 000 plates were made possible by the relatively high probe concentration. Combined with excellent detection sensitivity, even with the introduction of hydrodynamic flow and a reduced optical path length, these measures resulted in limits of detection ranging from 0.216 to 0.912 microM with a deuterium lamp light source (248 nm) and from 0.147 to 0.834 microM with a 476 nm blue light-emitting diode (LED) light source. Reproducibility over 30 consecutive runs without changing the electrolyte was excellent, with relative standard deviation (RSD) values of 0.14-0.80% for migration time, 1.27-3.36% for peak area and 0.88-5.12% for peak heights. The optimised electrolyte was used for the analysis of inorganic anions in air filter samples, providing good agreement with results obtained by ion chromatography.  相似文献   

18.
Lalwani S  Shave E  Vigh G 《Electrophoresis》2004,25(20):3323-3330
Hydrolytically stable, low-pI isoelectric membranes have been synthesized from low-pI ampholytic components, poly(vinyl alcohol), and a bifunctional cross-linker, glycerol-1,3-diglycidyl ether. The low-pI ampholytic components used contain one amino group and at least two weakly acidic functional groups. The acidic functional groups are selected such that the pI value of the ampholytic component is determined by the pK(a) values of the acidic functional groups. When the concentration of the ampholytic component incorporated into the membrane is higher than a required minimum value, the pI of the membrane becomes independent of variations in the actual incorporation rate of the ampholytic compound. The new, low-pI isoelectric membranes have been successfully used as anodic membranes in isoelectric trapping separations with pH < 1.5 anolytes and replaced the hydrolytically less stable polyacrylamide-based isoelectric membranes. The new low-pI isoelectric membranes have excellent mechanical stability, low electric resistance, good buffering capacity, and long life time, even when used with as much as 50 W power and current densities as high as 33 mA/cm(2) during the isoelectric trapping separations.  相似文献   

19.
魏芳  刘思敏  徐丽  吴成泰  冯钰锜 《色谱》2004,22(5):476-479
以葫[7]环联脲(CB[7])作为毛细管电泳添加剂,成功地分离了6种硝基苯类化合物。考察了pH值对电渗流的影响,初步评价了其基本的电泳性能,结果表明在所考察的pH值范围内(pH 2~6.5),葫[7]环联脲是质子化的,且吸附到毛细管内壁上,这使得毛细管内壁带上正电荷,电渗流反向;初步考察了葫[7]环联脲的浓度对分离的影响,证明了用葫[7]环联脲作为添加剂可完全分离对硝基乙苯、对硝基甲苯、对氯硝基苯、间二硝基苯、2,4-二硝基氯苯和硝基苯这6种物质,最佳的缓冲液为10 mmol/L Na2HPO4(用盐  相似文献   

20.
A new protein fractionation technique based on off-gel isoelectric focusing (IEF) is presented, where the proteins are separated according to their isoelectric point (pI) in a multiwell device with the advantage to be directly recovered in solution for further analysis. The protein fractions obtained with this technique have then been characterized with polymer nanoelectrospray for mass spectrometry (MS) analyses or with Bioanalyzer for mass identification. This methodology shows the possibility of developing alternatives to the classical two-dimensional (2-D) gel electrophoresis. One species numerical simulation of the electric field distribution during off-gel separation is also presented in order to demonstrate the principle of the purification. Experiments with pI protein markers have been carried out in order to highlight the kinetics and the efficiency of the technique. Moreover, the resolution of the fractionation was shown to be 0.1 pH unit for the separation of beta-lactoglobulin A and B. In addition, the isoelectric fractionation of an Escherichia coli extract was performed in standard solubilization buffer to demonstrate the performances of the technique, notably for proteomics applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号