首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
A CE method was developed for the determination of total (free and weakly bound) cyanide in electroplating solutions based on the use of a cationic surfactant (TTAB) and complexation with Ni(II)-NH3 solutions to Ni(CN)4 2–. Both direct complexation and cyanide distillation combined with complexation were tested. Under optimized conditions, this method is time-saving compared to standard methods. Total cyanide determined by CE had detection limits (with respect to the initial sample concentration) of 0.5 μg/mL for direct complexation and 50 ng/mL for distillation combined with complexation. Total cyanide and cyanide not amenable by chlorination (CNAC) were determined in real samples from spent electroplating baths. Received: 5 February 1998 / Revised: 26 July 1998 / Accepted: 1 August 1998  相似文献   

2.
A method for sampling and determination of hydrogen cyanide in cigarette smoke is described. Cigarette smoke is filtered through a glass fiber filter paper, and only gaseous compounds, such as hydrogen cyanide, are collected in a dilute sodium hydroxide solution. The cyanide is determined spectrophotometrically at 550 nm by the isonicotinic acid–pyrazolone method. Maximum absorbance is achieved within 10 min at room temperature, and remains constant for about 20 min. Beer’s law is obeyed in the range 0.04∼0.80 μg mL–1 cyanide, with a molar absorptivity of 3.48 × 104 L mol–1 cm–1. Received: 30 November 1998 / Revised: 21 April 1999 / Accepted: 30 April 1999  相似文献   

3.
Sampling and determination of hydrogen cyanide in cigarette smoke   总被引:1,自引:0,他引:1  
A method for sampling and determination of hydrogen cyanide in cigarette smoke is described. Cigarette smoke is filtered through a glass fiber filter paper, and only gaseous compounds, such as hydrogen cyanide, are collected in a dilute sodium hydroxide solution. The cyanide is determined spectrophotometrically at 550 nm by the isonicotinic acid–pyrazolone method. Maximum absorbance is achieved within 10 min at room temperature, and remains constant for about 20 min. Beer’s law is obeyed in the range 0.04∼0.80 μg mL–1 cyanide, with a molar absorptivity of 3.48 × 104 L mol–1 cm–1. Received: 30 November 1998 / Revised: 21 April 1999 / Accepted: 30 April 1999  相似文献   

4.
A method was developed for sampling and selective quantitative determination of typical volatile organic compounds (VOCs) in ambient urban air. A mobile and self-contained dual-channel air sampling tool based on solid phase adsorption was constructed. A simple calibration procedure circumventing the adsorption/desorption process was designed. The method was validated for seven “key-analytes”: n-hexane, 3-methyl-2-pentene, benzene, tetrachloroethene, styrene, 1,2,4-trimethylbenzene and acetophenone. The complete air sampling equipment is easily accommodated in a business suitcase. The lower limits of the practical working ranges are between 0.1 μg m–3 (tetrachloroethene) and 1.2 μg m–3 (benzene). Air samples were collected at a location in Salzburg with heavy motor vehicle traffic and measured in order to prove a satisfactory method performance under practical monitoring conditions. Received: 4 January 1998 / Revised: 14 September 1998 / Accepted: 21 October  相似文献   

5.
A method for the determination of cyanide in blood plasma by differential pulse polarography (DPP) is described without a drastic acidification of the sample. Cyanide was determined as tetracyanonickelate(II)-anion complex after a microwave-acid assisted cleanup and a selective complex extraction in a polyethylene methylene blue (PE-MB) impregnated column. The cyano complex was eluted from the column with water/acetonitrile and determined by pulse-polarography at –380 mV (Ag/AgCl). The linear range of calibration was obtained from 1.2 to 9.6 μg of cyanide with r = 0.99 and RSD = 9% of 1.2 μg of cyanide. A detection limit of 40 μg L–1 was calculated and the recoveries of cyanide from spiked samples were about 80%. This method was compared with the classical pyridine-pyrazolone method.  相似文献   

6.
A method for the determination/identification of residual sulfadimidine (SDD) in milk and eggs by high-performance liquid chromatography (HPLC) with a photo-diode array detector was developed. The sample preparation was performed by shaking with a mixture of 20% (w/v) trichloroacetic acid-methanol (4:1, v/v) followed by ultra-filtration using Molcut II?. A LiChrospher? 100 RP-8 (e) column and a mobile phase of 4% (v/v) acetic acid solution-acetonitrile (6:4, v/v) were used. The average recoveries from spiked SDD samples were 80.8–88.0% with coefficients of variation of 2.8–5.5%. The limits of detection in milk and eggs were 0.01 μg/mL and 0.01 μg/g, respectively. The total time required for the analysis of one sample was less than 20 min. Received: 7 October 1998 / Revised: 29 December 1998 / Accepted: 30 December 1998  相似文献   

7.
An analytical method for detecting and quantifying cefotaxime in plasma and several tissues is described. The method was developed and validated using plasma and tissues of rats. The samples were analyzed by reversed phase liquid chromatography (HPLC) with UV detection (254 nm). Calibration graphs showed a linear correlation (r > 0.999) over the concentration ranges of 0.5–200 μg/mL and 1.25–25 μg/g for plasma and tissues, respectively. The recovery of cefotaxime from plasma standards prepared at the concentrations of 25 μg/mL and 100 μg/mL was 98.5 ± 3.5% and 101.8 ± 2.2%, respectively. The recovery of cefotaxime from tissue standards of liver, fat and muscle, prepared at the concentration of 10 μg/g was: 89.8 ± 1.2% (liver), 103.9 ± 6.5% (fat) and 97.8 ± 2.1% (muscle). The detection (LOD) and quantitation (LOQ) limits for plasma samples were established at 0.11 μg/mL and 0.49 μg/mL, respectively. The values of these limits for tissues samples were approximately 2.5 times higher: 0.3 μg/g (LOD) and 1.25 μg/g (LOQ). For plasma samples, the deviation of the observed concentration from the nominal concentration was less than 5% and the coefficient of variation for within-day and between-day assays was less than 6% and 12%, respectively. The method was used in a pharmacokinetic study of cefotaxime in the rat and the mean values of the pharmacokinetic parameters are given. Received: 25 May 1998 / Revised: 27 July 1998 / Accepted: 1 August 1998  相似文献   

8.
A fast, sensitive and specific method for routine determination of residues from Chlormequat (CAS no. 7003-89-6) is described. The method is based on a simple clean-up using an SPE-C18 cartridge, high-performance liquid chromatography on a standard C18 column (Spherisorb S5 ODS1) and specific detection and quantification by electrospray mass spectrometry (LC-MS/MS). 13C-Chlormequat was synthesised for use as internal standard. Samples were extracted with methanol – water – acetic acid. Internal standard and ammonium acetate were added before C18-cartridge clean up and residues eluted with methanol – water – acetic acid, containing 50 mM ammonium acetate. Chromatographic separation was achieved using a solvent composed of acetonitrile – methanol – water – acetic acid (53:21:25:1 by volume), containing 50 mM ammonium acetate. Electrospray ionisation mass spectrometry was employed using m/z 58 (daughter ion of the Chlormequat quaternary ammonium ion, m/z 122) and m/z 61 (daughter ion of the 13C-Chlormequat quaternary ammonium ion, m/z 125) for quantification. The LC analysis time was 15 min and the limit of detection of the analytical method was 9 μg/kg. The performance of the method was demonstrated analysing grain material from an inter-comparison study. In Denmark the primary use of Chlormequat chloride (CCC, cycocel, or chlorocholin chloride, CAS no. 999-81-5) is for winter cereals and 11 such winter wheat samples from the Danish National Pesticide Survey were analysed. Residue contents were from below 0.01 up to 0.45 mg/kg, and thus below the EU maximum residue level of 2.0 mg/kg for wheat. Received: 22 December 1997 / Revised: 29 January 1998 / Accepted: 31 January 1998  相似文献   

9.
A continuous flow-through solid phase spectrophotometric system was developed for the determination of ascorbic acid based on the measurement of its intrinsic absorbance in the UV region when retained on a 1 mm Sephadex QAE A-25 anion exchanger gel layer which is placed into an appropriate quartz flow-through cell, the absorbance exhibited by this solid phase being monitored at 267 nm. A monochannel manifold was used, the sample (300, 600 or 1000 μL) being injected into the carrier solution (acetate buffer). This solution also elutes the analyte after developing the analytical signal, and regenerates the resin layer which, therefore, remains ready for the next sample. The linear dynamic range and other analytical parameters vary according to the sample volume injected. Three calibration lines were established for 300, 600 and 1000 μL sample volume, which ranged from 1.0 to 20.0, 0.5 to 10.0 and 0.2 to 6.0 μg mL–1, respectively. The detection limits were 0.04 (300 μL), 0.03 (600 μL) and 0.02 μg mL–1 (1000 μL), the sampling rates 28, 24 and 21 h–1, and the RSDs (n = 10) 0.87%, 1.08% and 0.90%, respectively. The amount of ascorbic acid in various samples (pharmaceuticals, sweets and urine) were successfully determined with this method. Received: 28 April 1998 / Revised: 3 June 1998 / Accepted: 30 June 1998  相似文献   

10.
A continuous flow-through solid phase spectrophotometric system was developed for the determination of ascorbic acid based on the measurement of its intrinsic absorbance in the UV region when retained on a 1 mm Sephadex QAE A-25 anion exchanger gel layer which is placed into an appropriate quartz flow-through cell, the absorbance exhibited by this solid phase being monitored at 267 nm. A monochannel manifold was used, the sample (300, 600 or 1000 μL) being injected into the carrier solution (acetate buffer). This solution also elutes the analyte after developing the analytical signal, and regenerates the resin layer which, therefore, remains ready for the next sample. The linear dynamic range and other analytical parameters vary according to the sample volume injected. Three calibration lines were established for 300, 600 and 1000 μL sample volume, which ranged from 1.0 to 20.0, 0.5 to 10.0 and 0.2 to 6.0 μg mL–1, respectively. The detection limits were 0.04 (300 μL), 0.03 (600 μL) and 0.02 μg mL–1 (1000 μL), the sampling rates 28, 24 and 21 h–1, and the RSDs (n = 10) 0.87%, 1.08% and 0.90%, respectively. The amount of ascorbic acid in various samples (pharmaceuticals, sweets and urine) were successfully determined with this method. Received: 28 April 1998 / Revised: 3 June 1998 / Accepted: 30 June 1998  相似文献   

11.
Total cyanide species are determined in a flow injection system which includes UV-photodissociation, gas-diffusion separation and spectrofluorimetric detection. Without the irradiation step, only cyanide easily released in acid medium, i.e. labile cyanide, is determined. Cyanide diffuses through a microporous PTFE membrane from an acid donor stream to a sodium hydroxide acceptor stream. Then, the transferred cyanide reacts with ?o-phthalaldehyde and glycine to form a highly fluorescent isoindole derivative. Complete cyanide recoveries were obtained for the most important metal cyanide complexes found in environmental samples, excepting cobaltocyanide. The sampling frequency for total cyanide was 4 samples h–1 and the detection limit was 0.4 μg L–1. Recoveries of total cyanide from river water obtained with this method are about 90% of those obtained with APHA Method 4500-CN C for total cyanide. Received: 10 February 1999 / Revised: 7 May 1999 / Accepted: 13 May 1999  相似文献   

12.
 Well-rounded grains are normally used as filtration media, because the spherical shape seems to be most suitable to get rapid and efficient removal operations. In this sense, the direct use of natural clays as filtration media is problematic, due to the plate-type shape of the particles. In this work, rounded grains of two natural clays processed by spray-drying are tested as filtration media. The settling regime of the grains in a filtration column was determined and the chromium removal from water was also tested. Sieved fractions now used (355–1680 μm) show settling behavior according to the transition regime. Preliminary results of chromium removal by the selected 355–420 μm sieved fraction bed show interesting capabilities for the Cr3+ species, while chromate (VI) retention is extremely low. Received: 12 January 1998 Accepted: 2 April 1998  相似文献   

13.
Procedures were developed for the speciation of trace amounts of aluminium present in percolating water of forest soil by online coupling of different chromatographic separation methods to an ICP-MS detection system. Inorganic and organic aluminium species were fractionated on a cation exchange column IONPAC CG12 (10-32). Phytotoxic polymeric aluminium hydroxides, as e.g. Al13 (AlO4Al12(OH)24(H2O)12 7+), were determined using pyrocatechol violet (PCV) as a species dependant complexing reagent prior to the cation exchange step. Size fractionation of the organic aluminium species was obtained by size exclusion chromatography using the columns Superdex-75-HR 10/30 and Superdex-Peptide-HR 10/30. Validation of the speciation procedures proved that online coupling HPLC to the element selective and sensitive ICP-MS detection system leads to low detection limits of 0.3–0.6 μg/L and high precision and reproducibility (1.2–3.5%) of the speciation procedures. Speciation data determined for aluminium in a percolating water of the Zierenberg catchment are given. Received: 20 November 1998 / Revised: 28 January 1999 / Accepted: 3 February 1999  相似文献   

14.
This work assesses the potential of natural analcime zeolite as a sorbent for the preconcentration of palladium. Palladium is quantitatively retained on modified analcime zeolite loaded with zincon using the column method in the pH range from 2.5 to 3.5 at a flow rate of 1 mL/min. The palladium complex was removed from the column with 5.0 mL of dimethylsulfoxide (DMSO) and determined by third-derivative spectrophotometry. The detection limit is 0.03 μg/mL (signal-to-noise ratio = 3) in the final solution. Since it is possible to retain 0.15 μg of palladium from 600 mL of solution passing through the column, elution with 5.0 mL of DMSO gives a detection limit of 0.25 ng/mL for palladium in the initial aqueous solution. The calibration curve is linear over the range 0.1 to 5.0 μg/mL of palladium(II) in the final solution with a correlation coefficient of 0.9996. Seven replicated determinations of 5.0 μg of palladium in 5.0 mL dimethylsulfoxide gave a mean d 3 A/dλ3 (peak-to-peak signal between λ2 = 625 and λ1 = 654 nm) of 0.64 with a relative standard deviation of 1.2%. The sensitivity of the method (d 3 A/dλ3) is 0.5843 mL/μg of palladium(II) from the slope of the calibration curve. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the determination of trace palladium in various synthetic and water samples. The text was submitted by the authors in English.  相似文献   

15.
An organic solvent-soluble membrane filter (MF) is proposed for the simple and rapid reconcentration with subsequent spectrophotometric determination of trace levels of iron (II) in water. Iron (II) is collected on a nitrocellulose membrane filter as ion associate of an anionic complex, which is formed by iron (II) and Ferrozine and a cation-surfactant. The ion-pair compound and the MF can be dissolved in small volumes of 2-ethoxyethanol and the absorbance of the resulting solution is measured at 560 nm against a reagent blank with molar absorptivity of 4.01 × 104 L mol–1 cm–1. Beer’s law is obeyed over the concentration range 0–10 μg L–1 of iron (II) in water and the detection limit is 0.03 μg L–1 with a 50-fold enrichment factor. The proposed method can satisfactorily be applied to the determination of iron (II) in natural water and sea water. Received: 23 June 1998 / Revised: 21 July 1998 / Accepted: 25 August 1998  相似文献   

16.
A reliable and highly sensitive method for the determination of hesperidin is described. It involves the formation of a highly fluorescent complex between hesperidin and aluminium (III) in a micellar medium. There is a linear relationship between fluorescence intensity (λem = 496 nm, λex = 391 nm) and hesperidin concentration over the range 5 × 10–7– 2 × 10–5 mol L–1. The detection limit is 79 μg L–1. The method can easily be adapted to a flow system using a three-channel manifold, the peak height being proportional to the hesperidin concentration over the range 1 × 10–6– 1 × 10–4 mol L–1. Manual and flow-injection procedures have been successfully applied to the determination of hesperidin in orange peel and orange juice. Received: 21 October 1998 / Revised: 16 December 1998 / Accepted: 25 December 1998  相似文献   

17.
A minicolumn packed with poly(aminophosphonic acid) chelating resin incorporated in an on-line preconcentration system for flame atomic-absorption spectrometry was used to determine ultratrace amounts of lead in mussel samples at μg L–1 level. The preconcentrated lead was eluted with hydrochloric acid and injected directly into the nebulizer for atomization in an air-acetylene flame for measurement. The performance characteristics of the determination of lead were: preconcentration factor 26.8 for 1 min preconcentration time, detection limit (3σ) in the sample digest was 0.25 μg g–1 (dry weight) for a sample volume of 3.5 mL and 0.2 g sample (preconcentration time 1 min), precision (RSD) 2.3% for 25 μg L–1 and 2.0% for 50 μg L–1. The sampling frequency was 45 h–1. The method was highly tolerant of interferences, and the results obtained for the determination of lead in a reference material testify to the applicability of the proposed procedure to the determination of lead at ultratrace level in biological materials such as mussel samples. Received: 1 November 2000 / Revised: 8 January 2001/ Accepted: 11 January 2001  相似文献   

18.
The generation of volatile species of silicon as a means to introduce silicon into an inductively coupled plasma has been studied. It is based on the reaction between silicon and fluoride ions in sulfuric acid media and it was carried out using different flow injection mountings. The first mounting works with an injection of 100 μL concentrated sulfuric acid and 150 μL silicon standard solution in a continuous 0.05 mol L–1 NaF solution flow. The method shows a linear response between the intensity of emission at 251.611 nm line and the silicon concentration from 0.1 to 200 μg mL–1, with a reproducibility of 2% and a detection limit of 0.004 μg mL–1. The second mounting produces the volatile species by the reaction between two opposed aerosol flows in a home-made nebulization chamber. This chamber has a Cross-Flow and a Meinhard nebulizer at either end. A linear response ranging from 0.1 to 1000 μg mL–1 of silicon solution is obtained and the reproducibility rises to 8%.The detection limit reached is 0.02 μg mL–1. The silicon content in real water samples was determined by applying both the above-mentioned methods and a third method for reference. Received: 6 November 1996 / Revised: 19 December 1996 / Accepted: 3 January 1997  相似文献   

19.
The sulfur content in metal sulfides can be determined after oxidative dissolution with bromine water-CCl4 at 50 °C by modified EDTA titration. The sulfides were quantitatively oxidized to SO4 2– without evolving H2S, and the metal cations were removed by cation exchange on an H-type column. Sulfate was precipitated as BaSO4, and the remaining Ba2+ was subsequently titrated with EDTA at pH = 10. The standard deviation for the determined sulfur in the metal sulfides, some of which can be hardly dissolved in usual mineral acid media, is about a few %. The method can be carried out with sample amounts containing as little as 1.5–2 mg sulfur. Received: 31 July 1997 / Revised: 5 January 1998 / Accepted: 9 January 1998  相似文献   

20.
The sulfur content in metal sulfides can be determined after oxidative dissolution with bromine water-CCl4 at 50 °C by modified EDTA titration. The sulfides were quantitatively oxidized to SO4 2– without evolving H2S, and the metal cations were removed by cation exchange on an H-type column. Sulfate was precipitated as BaSO4, and the remaining Ba2+ was subsequently titrated with EDTA at pH = 10. The standard deviation for the determined sulfur in the metal sulfides, some of which can be hardly dissolved in usual mineral acid media, is about a few %. The method can be carried out with sample amounts containing as little as 1.5–2 mg sulfur. Received: 31 July 1997 / Revised: 5 January 1998 / Accepted: 9 January 1998  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号