首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
G Azadi  A Tripathi 《Electrophoresis》2012,33(14):2094-2101
Control of EOF in microfluidic devices is essential in applications such as protein/DNA sizing and high‐throughput drug screening. With the growing popularity of poly(methyl methacrylate) (PMMA) as the substrate for polymeric‐based microfludics, it is important to understand the effect of surfactants on EOF in these devices. In this article, we present an extensive investigation exploring changes in EOF rate induced by SDS, polyoxyethylene lauryl ether (Brij35) and CTAB in PMMA microfluidic capillaries. In a standard protein buffer (Tris‐Glycine), PMMA capillaries exhibited a cathodic EOF with measured mobility of 1.54 ± 0.1 (× 10?4 cm2/V.s). In the presence of surfactant below a critical concentration, EOF was independent of surfactant concentration. At high concentrations of surfactants, the electroosmotic mobility was found to linearly increase/decrease as the logarithm of concentration before reaching a constant value. With SDS, the EOF increased by 257% (compared to buffer), while it was decreased by 238% with CTAB. In the case of Brij35, the electroosmotic mobility was reduced by 70%. In a binary surfactant system of SDS/CTAB and SDS/Brij35, addition of oppositely charged CTAB reduced the SDS‐induced EOF more effectively compared to nonionic Brij35. We propose possible mechanisms that explain the observed changes in EOF and zeta potential values. Use of neutral polymer coatings in combination with SDS resulted in 50% reduction in the electroosmotic mobility with 0.1% hydroxypropyl methyl cellulose (HPMC), while including 2% poly (N,N‐dimethylacrylamide) (PDMA) had no effect. These results will potentially contribute to the development of PMMA‐based microfluidic devices.  相似文献   

2.
Belder D  Deege A  Kohler F  Ludwig M 《Electrophoresis》2002,23(20):3567-3573
The channels of microfluidic glass chips have been coated with poly(vinyl alcohol) (PVA). Applied for microchip electrophoresis, the coated devices exhibited a suppressed electroosmotic flow and improved separation performance. The superior performance of PVA-coated channels could be demonstrated by electrophoretic separations of labeled amines and by video microscopy. While a distorted sample zone is injected using uncoated channels the application of PVA-coated channels results in an improved shape of the sample zone with less band broadening. Applying PVA-coated microchips for the separation of amines labeled with Alexa Fluor 350 even sub-second separations, utilizing a separation length of only 650 microm, could be obtained, while this was not possible using uncoated devices. By using PVA-coated devices rather than an uncoated chip a threefold increase in separation efficiencies could be observed. As the electroosmotic flow (EOF) was suppressed, the anionic compounds were detected at the anode whereas the dominant EOF in uncoated devices resulted in an effective mobility to the cathode. Besides improved separation performance another important feature of the PVA-coated channels was the suppressed adsorption of fluorescent compounds in repetitive runs which results in an improved robustness and detection sensitivity. Applying PVA-coated channels, rinsing or etching steps could be omitted while this was necessary for a reliable operation of uncoated devices.  相似文献   

3.
The surface properties of microfluidic devices play an important role in their flow behavior. We report here on an effective control of the surface chemistry and performance of polymeric microchips through a bulk modification route during the fabrication process. The new protocol is based on modification of the bulk microchip material by tailored copolymerization of monomers during atmospheric-pressure molding. A judicious addition of a modifier to the primary monomer solution thus imparts attractive properties to the plastic microchip substrate, including significant enhancement and/or modulation of the EOF (with flow velocities comparable to those of glass), a strong pH sensitivity and high stability. Carboxy, sulfo, and amino moieties have thus been introduced (through the incorporation of methylacrylic acid, 2-sulfoethyl-methacrylate and 2-aminoethyl-methacrylate monomers, respectively). A strong increase in the electroosmotic pumping compared to the native poly(methylmethacrylate)(PMMA) microchip (ca. electroosmotic mobility increases from 2.12 to 4.30 x 10(-4) cm(2) V(-1) s(-1)) is observed using a 6% methylacrylate (MAA) modified PMMA microchip. A 3% aminoethyl modified PMMA microchip exhibits a reversal of the electroosmotic mobility (for example, -5.6 x 10(-4) cm(2) V(-1) s(-1) at pH 3.0). The effects of the modifier loading and the pH on the EOF have been investigated for the MAA-modified PMMA chips. The bulk-modified devices exhibit reproducible and stable EOF behavior. The one step fabrication/modification protocol should further facilitate the widespread production of high-performance plastic microchip devices.  相似文献   

4.
Ludwig M  Belder D 《Electrophoresis》2003,24(15):2481-2486
Chiral separations of fluorescein isothiocyanate-labeled amines have been performed in poly(vinyl alcohol) (PVA)-coated microfluidic glass chips. Baseline separation of enantiomers could be realized in coated devices while they could not be resolved in uncoated chips. The electroosmotic flow (EOF) in PVA-coated channels is suppressed over a wide pH range which leads to a considerable improved reproducibility of migration times in repetitive analysis. Due to the high resolution obtained in such devices, it was possible to reliable determine the enantiomeric purity with high accuracy. One percent of the minor enantiomer could be determined in the presence of large excess of the other enantiomer. As the EOF was suppressed, the anionic compounds were detected at the anode whereas the dominant EOF in uncoated devices resulted in an effective mobility to the cathode. Applying PVA-coated channels considerable improved precision of migration times was found. The relative standard deviation of migration times was below 1% in PVA-coated devices. Accordingly, excessive rinsing or etching steps in order to stabilize the EOF could be omitted while this was necessary for a reliable operation of uncoated devices.  相似文献   

5.
A novel method for studying unlabeled living mammalian cells based on their autofluorescence (AF) signal in a prototype microfluidic device is presented. When combined, cellular AF detection and microfluidic devices have the potential to facilitate high-throughput analysis of different cell populations. To demonstrate this, unlabeled cultured cells in microfluidic devices were excited with a 488 nm excitation light and the AF emission (> 505 nm) was detected using a confocal fluorescence microscope (CFM). For example, a simple microfluidic three-port glass microstructure was used together with conventional electroosmotic flow (EOF) to switch the direction of the fluid flow. As a means to test the potential of AF-based cell sorting in this microfluidic device, granulocytes were successfully differentiated from human red blood cells (RBCs) based on differences in AF. This study demonstrated the use of a simple microfabricated device to perform high-throughput live cell detection and differentiation without the need for cell-specific fluorescent labeling dyes and thereby reducing the sample preparation time. Hence, the combined use of microfluidic devices and cell AF may have many applications in single-cell analysis.  相似文献   

6.
Electrokinetic flow of a suspension of erythrocytes (red blood cells, RBCs) in 20 num cylindrical fused-silica capillaries is examined in the present work. Flow direction anomalies are observed experimentally and tentatively explained by the development of a pH gradient between the cathode well and the anode well due to electrolysis reactions at the electrodes. This pH gradient alters the local zeta potentials of both the capillary and the RBC and thus the local electroendosmotic liquid flow (EOF) velocities and RBC electrophoretic (EP) velocities. The two velocities are opposite in direction but with EOF dominating such that the RBC moves toward the cathode, opposite to the anode migration observed in bulk conditions. The opposing zeta potentials also lead to RBC aggregation at the anode end for low fields less than 25 V/cm. As the electroendosmotic velocity decreases at the anode end due to decreasing pH, pressure-driven back flow develops to oppose the original EOF at the remaining portions of the capillary ensuring constant fluid flux. When the anode EOF velocity is smaller in magnitude than the EP velocity, reversal of blood cell transport is observed after a short transient time in which a pH gradient forms. RBC velocities and pH dependencies on electric field and MgCl(2) concentration are presented along with data showing the accumulation of charge separation across the capillary. Also, a short-term solution to the pH gradient formation is presented that could help thwart development of pH gradients in micro-devices at lower voltages.  相似文献   

7.
While polymer-based microfluidic devices offer some unique opportunities in developing low-cost systems for a variety of application areas, the ability to sort electrophoretically with high efficiency a number of different targets has remained somewhat elusive with an example consisting of achieving single base resolution as required for DNA sequencing. While the reasons for this are many-fold, it is clear that some type of coating is required on the polymer substrate to suppress the EOF and/or minimize potential solute/wall interactions. To this end, we report on a simple grafting procedure to allow the formation of polymer coats, which in this example used linear polyarcylamides (LPAs), onto a poly(methyl methacrylate) (PMMA) microfluidic device. The procedure involved creating an amine-terminated PMMA surface by appropriately functionalizing the PMMA through either a chemical or photochemical process. The aminated surface could then be used to covalently anchor methacrylic acid, which was used as a scaffold to produce LPAs on the surface through radical polymerization of acrylamide. The resulting surfaces demonstrated EOFs that were nearly an order of magnitude smaller than native PMMA. In addition, these LPA-coated devices could produce highly reproducible migration times of over approximately 20 runs with plate numbers exceeding 10(5) m(-1). Using gel electrophoretic analysis of a single base track generated from an M13mp18 template using Sanger cycle sequencing and dye-primer chemistry, the resolution value obtained for bases 199 and 200 was 0.18 while for bases 208 and 209 it was 0.21. For the native PMMA, these bands were found to comigrate.  相似文献   

8.
In this paper, we describe an amperometric-type enzymeless glucose sensing system based on a nanoporous platinum (Pt) electrode embedded in a microfluidic chip. This microchip system is comprised of a microfluidic transport channel network and a miniaturized electrochemical cell for nonenzymatic glucose sensing. Sample and buffer solutions were transferred to the cell by programmed electroosmotic flow (EOF). A nanoporous Pt electrode with the roughness factor of 200.6 was utilized to determine glucose concentrations in phosphate buffered saline (PBS) by the direct oxidation of glucose, without any separation process. The sensitivity of the developed system is 1.65 microA cm-2 mM-1 in the glucose concentration range from 1-10 mM in PBS.  相似文献   

9.
An electroosmotic flow (EOF)-switchable poly(dimethylsiloxane) (PDMS) microfluidic channel modified with cysteine has been developed. The native PDMS channel was coated with poly(diallyldimethylammonium chloride) (PDDA), and then gold nanoparticles by layer-by-layer technique was assembled on PDDA to immobilize cysteine. The assembly was followed by infrared spectroscopy/attenuated total reflection method, contact angle, EOF measurements and electrophoretic separation methods. EOF of this channel can be reversibly switched by varying the pH of running buffer. At low pH, the surface of channels is positively charged, EOF is from cathode to anode. At high pH, the surface is negatively charged, EOF is from anode to cathode. At pH 5.0, near the isoelectric point of the chemisorbed cysteine, the surfaces of channels show neutral. When pH is above 6.0 or below 4.0, the magnitude of EOF varies in a narrow range. And the modified channel surface displayed high reproducibility and good stability, a good reversibility of cathodic-anodic EOF transition under the different pH conditions was observed. Separation of dopamine and epinephrine as well as arginine and histidine were performed on the modified chip.  相似文献   

10.
Separation rates and resolutions within capillary electrophoretic (CE) systems can be enhanced when surface zeta potentials are uniform with minimum deviations from ideal pluglike flow. Microfluidic CE devices based on poly(methyl methacrylate) (PMMA) are being developed due to the optical clarity, availability, stability, and reproducible electroosmotic flow (EOF) rates displayed by this polymer. Control of EOF in polymer-based CE systems can be achieved by surface zeta potential alteration through chemical modification. Herein, a method will be presented for the surface functionalization of PMMA with chemistry analogous to formation of trichlorosilane self-assembled monolayers on SiO2. The current method involves two separate steps. First, surface activation with water-vapor plasma introduces surface hydroxylation. Second, treatment of the plasma-treated PMMA with a substituted trichlorosilane solution forms the functional surface layer. The modified surfaces were characterized using several analytical techniques, including water contact angle, X-ray photoelectron spectroscopy, Fourier transform infrared-attenuated total reflection, secondary ion mass spectroscopy, and measurement of EOF velocities within PMMA microchannels.  相似文献   

11.
J S Buch  P C Wang  D L DeVoe  C S Lee 《Electrophoresis》2001,22(18):3902-3907
The application of the field-effect for direct control of electroosmosis in a polydimethylsiloxane (PDMS)-based microfluidic system, constructed on a silicon wafer with a 2.0 microm electrically insulating layer of silicon dioxide, is demonstrated. This microfluidic system consists of a 2.0 cm open microchannel fabricated on a PDMS slab, which can reversibly adhere to the silicon wafer to form a hybrid microfluidic device. Aside from mechanically serving as a robust bottom substrate to seal the channel and support the microfluidic system, the silicon wafer is exploited to achieve field-effect flow control by grounding the semiconductive silicon medium. When an electric field is applied through the channel, a radial electric potential gradient is created across the silicon dioxide layer that allows for direct control of the zeta potential and the resulting electroosmotic flow (EOF). By configuring this microfluidic system with two power supplies at both ends of the microchannel, the applied electric potentials can be varied for manipulating the polarity and the magnitude of the radial electric potential gradient across the silicon dioxide layer. At the same time, the longitudinal potential gradient through the microchannel, which is used to induce EOF, is held constant. The results of EOF control in this hybrid microfluidic system are presented for phosphate buffer at pH 3 and pH 5. It is also demonstrated that EOF control can be performed at higher solution pH of 6 and 7.4 by modifying the silicon wafer surface with cetyltrimethylammonium bromide (CTAB) prior to assembly of the hybrid microfluidic system. Results of EOF control from this study are compared with those reported in the literature involving the use of other microfluidic devices under comparable solution conditions.  相似文献   

12.
The necessity for microchannel wall coatings in capillary and chip-based electrophoretic analysis of biomolecules is well understood. The regulation or elimination of EOF and the prevention of analyte adsorption is essential for the rapid, efficient separation of proteins and DNA within microchannels. Microchannel wall coatings and other wall modifications are especially critical for protein separations, both in fused-silica capillaries, and in glass or polymeric microfluidic devices. In this review, we present a discussion of recent advances in microchannel wall coatings of three major classes--covalently linked polymeric coatings, physically adsorbed polymeric coatings, and small molecule additives. We also briefly review modifications useful for polymeric microfluidic devices. Within each category of wall coatings, we discuss those used to eliminate EOF, to tune EOF, to prevent analyte adsorption, or to perform multiple functions. The knowledgeable application of the most promising recent developments in this area will allow for the separation of complex protein mixtures and for the development of novel microchannel wall modifications.  相似文献   

13.
Tang G  Yan D  Yang C  Gong H  Chai JC  Lam YC 《Electrophoresis》2006,27(3):628-639
Joule heating is inevitable when an electric field is applied across a conducting medium. It would impose limitations on the performance of electrokinetic microfluidic devices. This article presents a 3-D mathematical model for Joule heating and its effects on the EOF and electrophoretic transport of solutes in microfluidic channels. The governing equations were numerically solved using the finite-volume method. Experiments were carried out to investigate the Joule heating associated phenomena and to verify the numerical models. A rhodamine B-based thermometry technique was employed to measure the solution temperature distributions in microfluidic channels. The microparticle image velocimetry technique was used to measure the velocity profiles of EOF under the influence of Joule heating. The numerical solutions were compared with experimental results, and reasonable agreement was found. It is found that with the presence of Joule heating, the EOF velocity deviates from its normal "plug-like" profile. The numerical simulations show that Joule heating not only accelerates the sample transport but also distorts the shape of the sample band.  相似文献   

14.
We report here the photochemical surface modification of poly(methyl methacrylate), PMMA, microfluidic devices by UV light to yield pendant carboxylic acid surface moieties. Patterns of carboxylic acid sites can be formed from the micrometer to millimeter scale by exposure of PMMA through a contact mask, and the chemical patterns allow for further functionalization of PMMA microdevice surfaces to yield arrays or other structured architectures. Demonstrated here is the relationship between UV exposure time and PMMA surface wettability, topography, surface functional group density, and electroosmotic flow (EOF) of aqueous buffer solutions in microchannels made of PMMA. It is found that the water contact angle on PMMA surfaces decreases from 70 degrees to 24 degrees after exposure to UV light as the result of the formation of carboxylic acid sites. However, upon rinsing with 2-propanol, the water contact angle increases to approximately 80 degrees , and this increase is attributed to changes in surface roughness resulting from removal of low molecular weight PMMA formed from scission events. In addition, the surface roughness and surface coverage of carboxylic acid groups exhibit a characteristic trend with UV exposure time. Electroosmotic flow (EOF) in PMMA microchannels increases upon UV modification and is pH dependent. The possible photolysis mechanism for formation of carboxylic acid groups on PMMA surfaces under the conditions outlined in this work is discussed.  相似文献   

15.
Our dynamic capillary electrophoresis model which uses material specific input data for estimation of electroosmosis was applied to investigate fundamental aspects of isoelectric focusing (IEF) in capillaries or microchannels made from bare fused-silica (FS), FS coated with a sulfonated polymer, polymethylmethacrylate (PMMA) and poly(dimethylsiloxane) (PDMS). Input data were generated via determination of the electroosmotic flow (EOF) using buffers with varying pH and ionic strength. Two models are distinguished, one that neglects changes of ionic strength and one that includes the dependence between electroosmotic mobility and ionic strength. For each configuration, the models provide insight into the magnitude and dynamics of electroosmosis. The contribution of each electrophoretic zone to the net EOF is thereby visualized and the amount of EOF required for the detection of the zone structures at a particular location along the capillary, including at its end for MS detection, is predicted. For bare FS, PDMS and PMMA, simulations reveal that EOF is decreasing with time and that the entire IEF process is characterized by the asymptotic formation of a stationary steady-state zone configuration in which electrophoretic transport and electroosmotic zone displacement are opposite and of equal magnitude. The location of immobilization of the boundary between anolyte and most acidic carrier ampholyte is dependent on EOF, i.e. capillary material and anolyte. Overall time intervals for reaching this state in microchannels produced by PDMS and PMMA are predicted to be similar and about twice as long compared to uncoated FS. Additional mobilization for the detection of the entire pH gradient at the capillary end is required. Using concomitant electrophoretic mobilization with an acid as coanion in the catholyte is shown to provide sufficient additional cathodic transport for that purpose. FS capillaries dynamically double coated with polybrene and poly(vinylsulfonate) are predicted to provide sufficient electroosmotic pumping for detection of the entire IEF gradient at the cathodic column end.  相似文献   

16.
A hydrophilic polymer, poly(vinylpyrrolidone) (PVP), was employed for suppressing the electroosmotic flow (EOF). A capillary was filled with aqueous PVP solution for coating the capillary wall with PVP; the PVP solution was then replaced by a migration buffer solution containing no PVP. Three types of PVP with different molecular weights were examined. The EOF was suppressed more effectively as the molecular weight of PVP increased. The EOF in the coated capillary was approximately 10-fold smaller than that of a bare capillary and was constant in the pH range of 6-8. The suppressed EOF was stable even when no PVP was added to the migration buffer. However, the EOF increased significantly when sodium dodecyl sulfate was added into the migration buffer. The method was applied for determining the electrophoretic mobilities of inorganic anions that have negative electrophoretic mobilities larger than the electroosmotic mobility of the bare capillary. A novel method for determining the electrophoretic mobilities was proposed based on the linear relationship between electric current and electrophoretic mobility. The electrophoretic mobility was proportional to the electric current. Therefore, the intercept of the regression equation represents the electrophoretic mobility at room temperature. The electrophoretic mobilities were in good agreement with the absolute electrophoretic mobilities.  相似文献   

17.
The determination of glucose in microfluidic chips made of glass or PMMA was used as a model for the combination of an enzymatic reaction with the separation of compounds. It was based on the enzymatic oxidation of glucose and the amperometric detection of hydrogen peroxide. Real samples frequently contain compounds, such as ascorbic acid, which may interfere with quantitative glucose determinations. Thus, electrophoretic separation of specific from unspecific signals was envisaged by applying electric fields which are also used to control the flow of liquid via electroosmotic effects. Surface charge densities of the capillaries influence the electroosmotic flow (EOF). They are dependent on the chip material and on the adsorption of components from the background electrolyte. Reversal of the EOF after addition of cetyltrimethylammonium bromide (CTAB) and an increase in EOF after addition of sodium dodecylsulfate (SDS) were observed at lower surfactant concentrations with the PMMA chips rather than with the glass chips. For both chip materials these concentrations were below the critical micelle concentration. Effective separation of H2O2 and ascorbic acid was achieved with low CTAB concentrations, which lead to a reduction, but not to a reversal of the EOF. Reversal of the EOF by higher CTAB concentrations or the increase in cathodic EOF by SDS accelerated ascorbic acid transportation and reduced the differences in migration times. Thus, for the specific determination of glucose, glucose oxidase was added together with low CTAB concentrations to the background electrolyte. This avoided interference from ascorbic acid, and data obtained from the analysis of fruit juices showed a good correlation to data obtained from a reference method.  相似文献   

18.
M Sureda  A Miller  FJ Diez 《Electrophoresis》2012,33(17):2759-2768
A time-resolved microPIV method is presented to measure in an EOF the particles zeta potential in situ during the transient start-up of a microdevice. The method resolves the electrophoretic velocity of fluoro-spheres used as tracer particles in microPIV. This approach exploits the short transient regime of the EOF generated after a potential drop is imposed across a microchannel and before reaching quasisteady state. During the starting of the transient regime, the electrophoretic effect is dominant in the center of the channel and the EOF is negligible. By measuring the velocity of the tracer particles with a microPIV system during that starting period, their electrophoretic velocity is obtained. The technique also resolves the temporal evolution of the EOF with three regions identified. The first region occurs before the electroosmotic effect reaches the center of the channel, the second region extends until the EOF reaches steady state, and thereafter is the third region. The two time constants separating these regions are also obtained and compared to the theory. The zeta potential of 860 nm diameter polystyrene particles is calculated for different solutions including borate buffer, sodium chloride, and deionized water. Results show that the magnitudes of the electrophoretic and electroosmotic velocities are in the range of |300| to |700| μm/s for these measurements. The zeta potential values are compared to the well-established closed cell technique showing improved accuracy. The method also resolves the characteristic response time of the EOF, showing small but important deviations from current analytical predictions. Additionally, the measurements can be performed in situ in microfluidic devices under actual working EOF conditions and without the need for calibrations.  相似文献   

19.
We present an experimental study of the effect of pH, ionic strength, and concentrations of the electroosmotic flow (EOF)-suppressing polymer polyvinylpyrrolidone (PVP) on the electrophoretic mobilities of commonly used fluorescent dyes (fluorescein, Rhodamine 6G, and Alexa Fluor 488). We performed on-chip capillary zone electrophoresis experiments to directly quantify the effective electrophoretic mobility. We use Rhodamine B as a fluorescent neutral marker (to quantify EOF) and CCD detection. We also report relevant acid dissociation constants and analyte diffusivities based on our absolute estimate (as per Nernst-Einstein diffusion). We perform well-controlled experiments in a pH range of 3-11 and ionic strengths ranging from 30 to 90 mM. We account for the influence of ionic strength on the electrophoretic transport of sample analytes through the Onsager and Fuoss theory extended for finite radii ions to obtain the absolute mobility of the fluorophores. Lastly, we briefly explore the effect of PVP on adsorption-desorption dynamics of all three analytes, with particular attention to cationic R6G.  相似文献   

20.
Electroosmotic flow (EOF) was investigated in microfabricated fluidic devices using the current monitoring technique. Current changes ranging from 50 to 130 pA/s were detected. These observations indicate that in microfluidic devices with small reservoir volumes, electrolysis of water influences the fluid transport, giving rise to changes in pH and increase in concentration of ionic species in the fluidic system. As a result of the electrolysis and associated increment in ion concentration, the thickness of the Debye layer and surface potential vary, affecting the overall migration behavior of the solution. The magnitude of EOF and the electrophoretic properties of molecules can no longer be treated as constant/invariant. These temporal anomalies are undesirable during analytical separations and in fluid control applications. A numerical analysis of the impact of the continuous ionic strength increase on the EOF dynamics is presented using well-established conduction and EOF theories. The numerical results are found to be in good agreement with the observed current changes. These results indicate that to improve assay reproducibility, monitoring the electric current is an effective tool to determine whether electrolytic reactions are taking place. Our work also serves to test the numerical accuracy of EOF theories and models.  相似文献   