首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 664 毫秒
1.
Zusammenfassung Es wird eine photometrische Bestimmungsmethode beschrieben für Anilin (40–720 g/ml), Monoäthylanilin (90–1650 g/ml) und Diäthylanilin (100–1600 g/ml) mit Natriumchlorit in äthanolisch-wäßrigen Lösungen, sowie für Diäthylanilin (85–1140 g/ml) und Dimethylanilin (30–330 g/ml) neben den primären und sekundären Aminen in essigsaurer Lösung mit demselben Reagens. Das Verfahren liefert gute Ergebnisse.
Summary A photometric procedure is described for the determination of aniline (40–720 g/ml), monoethylaniline (90–1650 g/ml), and diethylaniline (100–1600 g/ml) with sodium chlorite in aqueous ethanolic solutions and of diethylaniline (85–1140 g/ml) and dimethylamline (30 to 330 g/ml) in presence of the primary and secondary amines in acetic acid solution using the same reagent. Good results have been obtained,
  相似文献   

2.
    
Zusammenfassung 2-Thiobarbitursäure wird zum Nachweis und zur Bestimmung von Fe(III) verwendet. Im Reagensglas kann noch 1 g Fe(III)/ml nachgewiesen werden. Eine größere Empfindlichkeit (0,2 g/ml) wird bei Anwendung eines mit Thiobarbitursäurelösung getränkten Papiers erreicht. Die photometrische Bestimmung ist im Konzentrationsbereich 4–40 g/ml mit einem Fehler von höchstens ±0,5 g möglich.
Summary 2-Thiobarbituric acid is recommended for the detection and determination of trivalent iron. In the test tube 1 g of Fe(III)/ml can be detected, whereas this limit can be reduced to 0.2 g of Fe(III)/ml by use of paper impregnated with the reagent. The photometric determination is possible within the range of 4–40 g of Fe(III)/ml with an error of not more than ±0.5 g.
  相似文献   

3.
The absorption spectra of 4f electron transitions of the complexes of neodymium and erbium with 5,7-dibromo-8-hydroxyquinoline in the presence of octylphenol poly(ethyleneglycol)ether have been studied by normal and third-derivative spectrophotometry. The proposed method is free of interference of other rare earths. The calibration graphs were linear up to 18 g/ml of neodymium and 21 g/ml of erbium (in the final solution). The derivative molar absorptivities are 395 l.mol–1.cm–1 for neodymium and 3421.mol–1.cm–1 for erbium. The corresponding values of Sandell's sensitivity were 0.36 and 0.49 g.cm–1, respectively. The relative standard deviations evaluated from ten independent determinations of 2.5 g/ml of neodymium and erbium are 1.5 and 3.8% for neodymium and 1.8 and 4.1% for erbium in absence and presence of 70 g of lanthanum, respectively. The detection limits (signal to noise ratio=2) are 0.23 g/ml for neodymium and 0.30 g/ml for erbium. The method has been used for the determination of neodymium and erbium in mixed rare earths with satisfactory results.  相似文献   

4.
Summary Methods of sampling atmospheres contaminated by pesticides in factory and agricultural environments, and subsequent analysis by HPLC, are discussed. Air sampling is carried out using porous polymer or filter collection media, usually a 100 dm3 air volume is suitable. Detection limits with ultra-violet detection are in the range 0.1 to 10 g m–3.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

5.
The formation of nucleic acids/8-hydroxyquinoline/yttrium(III) ternary complexes and their fluorescent properties have been studied. The nucleic acids studied include native and thermally denatured calf thymus DNA, fish sperm DNA and yeast RNA. In the range of pH 7.6–8.5, controlled by NH3-NH4C1 buffer, ternary complexes are formed that fluoresce at different wavelengths with different nucleic acids. Based on the fluorescence reactions, sensitive spectrofluorimetric methods for nucleic acids are proposed. In optimal conditions, the calibration curves were linear in the range 0.5–4.0 gml–1 for calf thymus DNA, 0.5–2.5 g ml–1 for fish sperm DNA and 0.5–4.0 g ml–1 for yeast RNA. The limits of determination (3 ) were 0.030 g ml–1 for calf thymus DNA, 0.020 g ml–1 for fish sperm DNA and 0.090 g ml–1 for yeast RNA. Corresponding to the interferences of coexisting substances, six synthetic samples were constructed and the results of determination were satisfactory.  相似文献   

6.
A method for the simultaneous spectrophotometric determination of cobalt, nickel and iron based on the formation of their complexes with 1,5-bis(di-2-pyridylmethylene) thiocarbonohydrazide is proposed. The absorption curves of these complexes overlap severely in the scanning range 390–510 nm. The analyte concentrations are calculated by a least squares fit of the pure spectra to the mixture spectra, which therefore makes the simultaneous determination of these metallic ions possible without tedious pretreatment. The detection limits afforded by the proposed method range from 0.05 g/ml for Fe and Ni to 0.1 g/ml for Co. Root-mean-squared errors of prediction of 0.085 g/ml for Co, 0.048 g/ml for Ni and 0.1172 g/ml for Fe were obtained using the wavelength range 400–510 nm and 0.147 g/ml for Co, 0.107 g/ml for Ni and 0.127 g/ml for Fe using the wavelength range 420–434 nm. The effect of interferences is studied and the proposed method is applied to analysis for the above elements in synthetic samples and real samples, such as biological materials and alloys.  相似文献   

7.
Zusammenfassung Eine neue Methode zur Durchführung gravimetrischer Bestimmungen im Mikrogrammbereich wurde beschrieben; diese beruht im wesentlichen darauf, daß der Niederschlag nicht mehr zusammen mit dem Filter, sondern nach Überführen mit einem geeigneten Lösungsmittel in einem separaten Wägegefäß gewogen wird.Die dazu nötigen Geräte und deren Herstellung wurden beschrieben. Nach dieser Methode wurden folgende Bestimmungen mit zufriedenstellender Richtigkeit durchgeführt: 2,5–25g Al, 5–50g Cu und 5–50g Zn mit Oxin, 2,5–25g Fe(III) und 2,5–25g Ti(IV) mit N-Benzoyl-phenylhydroxylamin, 5–50g Ni und 5–50g Cu mit Salicylaldoxim, 2,5–50g Co(II) und 2,5–50g Fe(III) mit -Nitroso--naphthol sowie 5–50g Chlorid als Silberchlorid.
Precipitation analysis in the microgram-scale: A new method
Summary A new method for gravimetric determinations in the microgram-scale is described. This method is based on the fact that the precipitate is not weighed together with the filter but is transferred to a separate weighingvessel using a suitable solvent. The necessary simple devices and their use are described. The following determinations were carried out with satisfying accuracy: 2,5–25g Al, 5–50g Cu and 5–50g Zn with Oxine, 2,5–25g Fe and 2,5–25g Ti withN-benzoylphenylhydroxylamine, 5–50g Ni and 5–50g Cu with salicylaldoxime, 2,52–50g Co and 2,5–50g Fe with -nitroso--naphthol and 5–50g chloride as silver chloride.
  相似文献   

8.
The absorption spectra of 4f electron transitions of the neodymium and erbium complexes with benzoyl-indan-1,3-dione and cetylpyridinium chloride have been studied by conventional and derivative spectrophotometry. The second-derivative spectrum has been used to eliminate the interference of the other lanthanides, and to increase the sensitivity by a further factor of 4–6. Beer's Law is obeyed for 6–29 g/ml Nd and 7–33 g/ml Er. The relative standard deviations evaluated from 10 independent determinations of 5.0 g/ml Nd and Er were 1.1% (Nd) and 1.6% (Er). The detection limits obtained from the sensitivity of the calibration graphs and 3s b, (standard deviation of the blank,n = 11) were 0.63 g/ml Nd and 0.61 g/ml Er. The quantification limits (10s b) were 2.1 g/ml Nd and 2.0 g/ml Er. A method for the direct determination of neodymium and erbium in rare earth mixtures with good accuracy and selectivity is proposed.  相似文献   

9.
Column preconcentration methods have been established for the spectrophotometric determination of trace nitrite with sulfanilic acid (SA) orp-aminoacetophenone (AAP) as the diazotizable aromatic amine andN, N-dimethylaniline (DMA) or 1-aminonaphthalene (AN) as the coupling agent, using differention-pairs co-precipitated with biphenyl. Nitrite ion reacts with SA in the pH range 2.0–3.0 and AAP in the pH range 1.7–3.0 in HCl medium to form water-soluble colourless diazonium cations. These cations are subsequently coupled with DMA in the pH range 3.7–6.1 for the SA-DMA system and AN in the pH range 1.7–2.3 for the AAP-AN system to be retained on microcrystalline biphenyl packed in a column. The solid mass is dissolved out from the column with 5 ml of DMF and the absorbance is measured by a spectrophotometer at 420 nm for the SA-DMA system and at 517 nm for the AAP-AN system. The calibration was linear over the concentration ranges 0.3–6.0 g of nitrite in 5 ml of DMF solution (i.e., 0.02–0.40 g/ml in the sample solution) for the SA-DMA system and 0.5–7.0 g of nitrite in 5 ml of DMF solution (i.e., 0.03–0.47 g/ml in the sample solution) for the AAP-AN system. The molar absorptivity and Sandell's sensitivity were respectively 2.63 × 104lmol–1cm–1 and 1.75 × 10–3 g cm–2 for SA-DMA and 3.28 × 104lmol–1 cm–1 and 1.40 × 10–3 g cm–2 for AAP-AN. The concentration factors were 4 and 16 for SA-DMA and AAP-AN, respectively. The detection limits were 0.0138 and 0.0175 g/ml NO2 for SA-DMA and AAP-AN, respectively. Seven replicate determinations of a solution containing 3.5 g of nitrite gave mean absorbances of 0.410 and 0.500 with relative standard deviations of 0.51 and 0.55% for SA-DMA and AAP-AN, respectively. Interference from various foreign ions has been studied and the methods have been applied to the determination of nitrite in environmental samples.  相似文献   

10.
The absolute concentrations of iodine, bromine and chlorine in milk, have been determined by epithermal neutron activation followed by high resolution gamma-ray spectrometry. Two kinds of milk commonly consumed in Israel have been investigated. The concentration of iodine, bromine and chlorine were found to be 0.18–0.30 g/ml, 2.02–2.85 g/ml and 0.65 mg/ml, respectively. The method is fast, selective, accurate and highly sensitive.  相似文献   

11.
Summary Nitrosamines in alcoholic beverages and malted barley were analysed by adsorption from the gas phase onto a porous polymer trap of Chromosorb 104 and subsequent desorption of the trapped compounds directly to a gas chromatograph fitted with glass capillary column and alkali-FID. The detection limit for NDMA was 0.05 g/l in beer samples and 0.3 g/kg in malted barley.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

12.
A selective and sensitive method for the extraction and microgram determination of molybdenum (VI) with hydroxamic acid as yellow molybdenum-hydroxamate complex from acidic medium is described. The molybdenum-PCPPSAHA complex has max 388 nm, molar absorptivity 5.0 × 103l mol–1 cm–1. The system obeys Beer's law in the range of 1–28 g/ml of molybdenum(VI). Sandell's sensitivity is 0.0192 g cm2 and stoichiometry of the complex is 12, molybdenum: PCPPSAHA while mixed complex molybdenum-PCPPSAHA-morin has max 400 nm and molar absorptivity 5.9 × 103lmo1–1 cm–1 and stoichiometry of the complex is 121.The molybdenum is determined by graphite furnace atomic absorption spectrophotometry after directly pipetted the extract into the furnace which increases the sensitivity 20 fold.  相似文献   

13.
The effect of cationic surfactants (cetyltrimethylammonium bromide, cetylpyridinium bromide, and tetrabutylammonium perchlorate) and a nonionic surfactant (OP-7) on the conditions of the immobilization of 4-(2-pyridylazo)resorcinol (PAR) on three types of silica gel (Silochrom S-120 (200–350 m), Silochrom S-120 (315–500 m), and Silochrom S-80 (200–350 m)) was studied. It was found that OP-7 does not affect the adsorption of surfactants. The effect of cationic surfactants increases in the order tetrabutylammonium perchlorate < cetyltrimethylammonium bromide < cetylpyridinium bromide. The adsorption activity of silica gels increases in the order Silochrom S-120 (315–500 m) < Silochrom S-80 (200–350 m) < Silochrom S-120 (200–350 m). Cetylpyridinium bromide provides full immobilization of PAR on silica gel Silochrom S-120 (200–350 m) in the pH range 2–9.  相似文献   

14.
The determination of trace metals, e.g. Bi, Cd, Pb, in high-purity aluminium, zinc and commercial steel by flame or graphite furnace atomic absorption spectrometry following their preconcentrations as iodo complexes on XAD-1180 resin by means of a short column system is described. The recoveries are quantitative (95%). The relative standard deviations varies between 6% and 10%. The relative errors are less than 8% in a concentration range of 1 × 10–3 –4 × 10–5%. Detection limits for flame AAS and GFAAS were in the ranges of 0.002–0.110 g/ml and 0.0003–0.004 g/ml or in the ranges of 0.08–4.40 g/g and 0.012–0.16 g/g with respect to the solid samples, respectively.  相似文献   

15.
Nanometer-sized l-cysteine-capped ZnS particles have been synthesized and used as a fluorescence probe to investigate the effect of proteins on fluorescent intensity. With =190 nm, maximum and constant synchronous fluorescence enhancement was produced at 267 nm and pH 5.12 in the presence of proteins. A highly sensitive synchronous fluorescence method for the rapid determination of proteins has been developed. Under optimum conditions, calibration graphs are linear over the range 0.03–8.0 g mL–1 for bovine serum albumin (BSA), 0.01–6.0 g mL–1 for human serum albumin (HSA), 0.05–8.0 g mL–1 for -globulin (-G), and 0.04–4.0 g mL–1 for ovalbumin, respectively. The relative standard deviations of seven replicate measurements were 1.75% for 1.0 g mL–1 BSA, 1.90% for 1.0 g mL–1 HSA, 1.65% for 1.0 g mL–1 -G, and 2.32% for 1.0 g mL–1 ovalbumin.  相似文献   

16.
A first-order derivative spectrophotometric method has been developed for the simultaneous determination of copper, mercury and lead at g/L levels using dithizone as reagent. The procedure involves the simultaneous extraction of these elements by dithizone in chloroform from weakly alkaline solutions. Linear calibration curves were obtained in the ranges 0.5–10 (Cu), 1–10 (Hg) and 1–10 (Pb) g present in 40 ml of aqueous phase with detection limits of 5 g/L (Cu) and 20 g/L (Hg and Pb). The R.S.D.s for 100 g/L of copper, mercury and lead were 2.5, 2.6 and 3.1% respectively, for 5 determinations. The method is applicable for the determination of copper and lead in marine sediment samples with good precision and accuracy.  相似文献   

17.
New homopolynuclear nickel(II) xanthate complexes with nitrogen donor heterocycles as bridging ligands have been prepared, namely [Ni(Rxa)2(-L)]n and [Ni2(Rxa)4(-L1)], where R=i-Pr,i-Am; xa=OCS2– L=1,2-bis(4- pyridyl)ethane (bpe), 4,4-dithiodipyridyl (dtp), 1,2-bis(4- pyridyl)ethylene (dpe), 4,4-trimethylene-dipyridine (tmd); L1=2,3-bis(2-pyridyl)pyrazine (bpp), 2,4-bis(5,6- diphenyl-1,2,4-triazine-3-yl)pyridine (bdt), or 2,4,6-tris(2- pyridyl)-1,3,5-triazine (tpt). The compounds have been characterized by elemental analyses, i.r. and electronic spectroscopies, magnetochemical and conductivity measurements. The results show that the [Ni(Rxa)2(-L)]n complexes are linear polymers in which the nitrogen heterocycles bridge between the nickel(II) ions, which are coordinated by four sulfur and two nitrogen atoms and have trans-octahedral geometry. The nearly constant values of the effective magnetic moment (3.36–3.34 eff/B) over the 77–295 K temperature range indicate that exchange interactions are lacking among the paramagnetic centres in the linear structure, [Ni(i-Amxa)2(dpe)]n. The variable- temperature magnetic susceptibilities of the [Ni2(i-Prxa)4(bpp)] (3.00–2.95eff/B per Ni atom), [Ni2(i-Prxa)4(bdt)] (2.72–2.63 eff/B per Ni atom), and [Ni2(i-Amxa)4(tpt)] (2.76–1.87 eff/B per Ni atom) were measured down to liquid nitrogen temperature. In the case of binuclear nickel(II) complexes with bdt or tpt, antiferromagnetic coupling between the nickel(II) ions was detected, giving the exchange integral J=–4.0cm–1 and –29.6cm–1, respectively.  相似文献   

18.
T-21 silica, a commonly used encapsulation material in neutron activation analysis of small samples, was analyzed by INAA to determine trace levels of the following impurities: Na, Sc, Cr, Fe, Co, Ni, Zn, Br, Sb, La, Ce, Sm, Tb, Hf and Au. In the unprocessed form supplied by the manufacturer, pieces of T-21 weighing 50 mg contain 6·10–2 g Na; 9·10–3 g Fe; 3·10–7–7·10–6 g light REE, Sc and Hf and 4·10–8 g Tb and Au. In a series of glass-blowing steps, in which unfiltered gases were used for fuel, and cleaning steps, in which reagent grade aqua regia was used, irradiation vials were produced which contain higher average levels of Sc, La, Sm, Tb and Hf, by factors ranging from 1.3 for Sm to 11.5 for La, and lower average levels of Co, Na and Fe, by factors of 1.4, 2.0 and 4.0, respectively, than the unprocessed material. These contamination levels lead to blank corrections of 21% for La, 2.6% for Ce and 3.0% for Hf in 40 g samples of refractory inclusions from carbonaceous chondrites, if counted in their irradiation vials.  相似文献   

19.
Summary Selective and sensitive procedures are described for the direct differential pulse polarographic determination of antimony(III), indium(III) and cadmium(II) in propylene carbonate. This method was based on the salting-out extraction of their halide complexes into the solvent from acidic aqueous media. The extracted Sb(III), In(III) and Cd(II) complexes exhibit sharp differential pulse polarographic peaks at –0.21 V, –0.63 V and –0.72 V vs. SCE in salted-out propylene carbonate phases respectively. The lower limits of determination are 5.0g for Sb(III), 0.6g for In(III), and 0.2g for Cd(II) in 10 ml of the organic phase. A number of foreign ions are eliminated through both processes of solvent extraction and polarography using propylene carbonate.
Propylencarbonat als Lösungsmittel für die Fällungs-Extraktion und die nachfolgende Differential-Puls-Polarographie
Zusammenfassung Selektive und empfindliche Verfahren für die direkte Bestimmung von Sb(III), In(III) und Cd(II) in Propylencarbonat mit Hilfe der Differential-Puls-Polarographie wurden beschrieben. Die vorliegende Methode beruht auf der Fällungs-Extraktion der Halogenid-Komplexe aus wäßrig-saurem Medium in das Lösungsmittel. Die extrahierten Komplexe des Sb(III), In(III) und Cd(II) ergeben scharfe Peaks bei –0,21 V, –0,63 V und –0,72 V gegen die Kalomelelektrode in den betreffenden Propylencarbonat-Phasen. Die unteren Grenzen der Bestimmungen liegen bei 5,0g Sb, 0,6g In bzw. 0,2g Cd in 10 ml organischer Phase. Eine Anzahl Fremdionen wird durch die beiden Prozesse der Extraktion und der Polarographie in Propylencarbonat ausgeschaltet.
  相似文献   

20.
Summary Retention characteristics of metoprolol have been studied in reversed phase mode on RP2, RP8 and CN columns. The plots of retention time as a function of the acetonitrile content and of the ionic strength of the mobile phase permitted the choice of the best conditions to separate metoprolol from plasma components by switching of these three types of columns.Human plasma (0.5–1 ml) diluted with water is first injected on a RP2 column (25–40 m particle diameter, prepared by dry packing) and rinsed with water. The sample is then back eluted with acetonitrile-0.022 M acetate buffer (7525, v:v) and switched to a CN column (10 cm long, 5 m particle diameter). The heart cut of the eluate is selected and loaded on a RP8 analytical column (25 cm long, 5 m particle diameter) with acetonitrile-0.088 M acetate buffer (7525, v:v) as mobile phase.Auto-sampler and switching valves are actuated automatically by a computing integrator based on a fixed time schedule. The duration of one cycle is about 30 min, but the last analytical step is about 15 min and represents the time interval between two injections. Metoprolol, its alpha-hydroxy metabolite and the internal standard are detected by fluorescence (ex= 225 nm; em > 320 nm).Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏