首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
It is difficult to do internal mass fractionation corrections for isotope dilution analysis by thermal ionization mass spectrometry (TIMS) or multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS), especially for MC-ICP-MS. In this study, calculation methods for direct internal fractionation correction of spiked isotope analysis by TIMS or MC-ICP-MS cycle by cycle for elements having at least two internal reference isotopic ratios are presented. For TIMS, direct internal mass fractionation correction calculation methods, based on both power and exponential laws, are derived; whereas for MC-ICP-MS, due to larger mass fractionation effects, only exponential law is considered. These calculation strategies can be applied for both static and multi-dynamic measurements. For multi-dynamic measurements, the isotope fractionation effect, gain and cup efficiency effects of different collectors, as well as ion beam fluctuation effects are all simultaneously eliminated. The calculation methods were verified by Sr isotopic analyses of spiked NBS987 standard solutions by TIMS and Hf isotopic analyses of spiked geological reference materials by MC-ICP-MS. In addition, precise and accurate calibrations of isotopic ratios of the spikes, based on the calculation methods, are discussed.  相似文献   

2.
Sahoo YV  Nakai S  Ali A 《The Analyst》2006,131(3):434-439
Tungsten isotope composition of a sample of deep-seated rock can record the influence of core-mantle interaction of the parent magma. Samples of kimberlite, which is known as a carrier of diamond, from the deep mantle might exhibit effects of core-mantle interaction. Although tungsten isotope anomaly was reported for kimberlites from South Africa, a subsequent investigation did not verify the anomaly. The magnesium-rich and calcium-rich chemical composition of kimberlite might engender difficulty during chemical separation of tungsten for isotope analyses. This paper presents a simple, one-step anion exchange technique for precise and accurate determination of tungsten isotopes in kimberlites using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Large quantities of Ca and Mg in kimberlite samples were precipitated and removed with aqueous H(2)SO(4). Highly pure fractions of tungsten for isotopic measurements were obtained following an anion exchange chromatographic procedure involving mixed acids. That procedure enabled efficient removal of high field strength elements (HFSE), such as Hf, Zr and Ti, which are small ions that carry strong charges and develop intense electrostatic fields. The tungsten yields were 85%-95%. Advantages of this system include less time and less use of reagents. Precise and accurate isotopic measurements are possible using fractions of tungsten that are obtained using this method. The accuracy and precision of these measurements were confirmed using various silicate standard rock samples, JB-2, JB-3 and AGV-1.  相似文献   

3.
A straightforward one-step Hf purification protocol for geological samples using common anion-exchange chromatography and isotopic measurements by multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS) is described in this paper. The sample is dissolved in concentrated HF–HNO3 mixtures with round-bottom Savillex? Teflon screw-top capsules or high-pressure stainless steel jacketed Teflon bombs. After complete dissolution, the chemical separation between Hf and isobarically interfering elements such as Lu, Yb, and matrix elements like Ti, is performed and achieved simultaneously using a common one-step anion exchange resin (AG1-X8). The Hf yields are >90% and total procedural blanks are lower than 20 pg. This protocol not only avoids using multiple-stage ion exchange resins, but also eliminates perchloric acid to break down fluorides after HF treatment of the sample. In addition to whole rock, this protocol is also practical for zircon and baddeleyite Hf purification prior to isotopic measurement. New Hf isotopic data for zircon 91500, Temora, CN92-1 and FM0411, together with Phalaborwa baddeleyite are presented for this method. Multiple analyses of the international geological reference materials and standard zircon and baddeleyite used in U–Pb geochronology demonstrate that this method is simple, economic, efficient and reproducible.  相似文献   

4.
The unique capabilities of multiple collector inductively coupled mass spectrometry (MC-ICP-MS) for high precision isotope ratio measurements in light elements as Li, Mg, Ca, and Cu are reviewed in this paper. These elements have been intensively studied at the Geological Survey of Israel (GSI) and other laboratories over the past few years, and the methods used to obtain high precision isotope analyses are discussed in detail. The scientific study of isotopic fractionation of these elements is significant for achieving a better understanding of geochemical and biochemical processes in nature and the environment.  相似文献   

5.
This study aims at developing a new analytical procedure for U–Th radioactive disequilibrium of carbonate rock samples. The procedure utilizes commercially available U and Th reagents as spikes for isotope dilution analysis with a multiple-collector inductively coupled mass spectrometer (MC-ICP-MS). Uranium and thorium in a carbonate sample were purified by Fe-coprecipitation, anion exchange resin, and U/TEVA resin. Isotopic compositions of purified spiked and unspiked U and Th were measured respectively for abundance and isotopic analyses. The correction of mass fractionation and the Daly/Faraday gain factor for Th measurements is carried out with a U standard solution. Accuracy of our method was confirmed by analyses of a coral sample that had been dated with thermal ionization mass spectrometry (TIMS). Our results indicate that U–Th disequilibrium studies are possible using easily available U and Th reagents as spikes.  相似文献   

6.
Fujii T  Suzuki D  Watanabe K  Yamana H 《Talanta》2006,69(1):32-36
The total evaporation technique of thermal ionization mass spectrometry was applied to the isotopic analysis of chromium. High measurement reproducibility of the chromium isotope ratios was verified (2 S.E. < 0.05% (53Cr/52Cr)), while a clear mass fractionation effect was observed by using conventional measurement technique. The chromium isotope ratios analyzed by the total evaporation method were not affected by the sample amount on the rhenium filament (50-500 ng Cr). The isotopic analysis under the coexistence of zinc was also performed, and its effect to the chromium isotope ratios was confirmed.  相似文献   

7.
Ulfbeck D  Baker J  Waight T  Krogstad E 《Talanta》2003,59(2):365-373
A new method for rapid sample digestion and efficient chemical separation of Hf and REE from rock samples for precise isotopic analysis is presented. Samples are digested by fusion in the presence of a lithium borate flux at 1100 °C and dissolved whilst molten in dilute nitric or hydrochloric acid. Prior to chemical separation using ion exchange techniques, Li and B from the flux material and Si from the sample are separated from the remaining major elements, REE and high field strength elements (HFSE) in the sample by Fe-hydroxide co-precipitation. The chemical separation of Hf is a two-stage procedure designed to first remove the remaining matrix elements (e.g. Fe, Ba) in the sample using standard cation exchange techniques, followed by separation of Hf from the REE and HFSE on TEVA extraction chromatographic resin. Hf yields are >90% and total procedural blanks are ca. 50 pg. Hf isotope ratios of a synthetic standard solution and replicate digestions of international rock standards BHVO-1 and BCR-1 measured on multi-collector inductively coupled plasma mass spectrometer (MC-ICPMS) reproduce similarly to ≤50 ppm (2 S.D.). The following elemental ratios are routinely obtained for elements, which interfere isobarically or may affect the ionisation and/or fractionation behaviour of Hf during analysis: 176Yb/176Hf<0.0001; 176Lu/176Hf<0.00001; Ti/Hf<0.05. This technique also provides a means of separating Nd from the REE fraction for isotopic analysis and, potentially, may be adapted for measurement of Lu/Hf ratios by isotope dilution techniques.  相似文献   

8.
Copper is an essential trace metal that shows a vertical recycled-scavenged profile in the ocean. To help elucidate the biogeochemical cycling of Cu in the present and past oceans, it is important to determine the distribution of Cu isotopes in seawater. However, precise isotopic analysis of Cu has been impaired by the low concentrations of Cu as well as co-existing elements that interfere with measurements by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The objective of this study is to develop a simple Cu pre-concentration method using Nobias-chelate PA1 resin (Hitachi High Technologies). This extraction followed by anion exchange, allows precise analysis of the Cu isotopic composition in seawater. Using this method, Cu was quantitatively concentrated from seawater and >99.9999% of the alkali and alkaline earth metals were removed. The technique has a low procedural blank of 0.70 ng for Cu for a 2 L sample and the precision of the Cu isotopic analysis was ±0.07‰ (±2SD, n = 6). We applied this method to seawater reference materials (i.e., CASS-5 and NASS-6) and seawater samples obtained from the northwestern Pacific Ocean. The range of dissolved δ65Cu was 0.40–0.68‰.  相似文献   

9.
Accurate determination of lithium (Li)isotopic composition in natural geological samples is the basis for Li isotope geochemical studies. In this study, a method contained preparation of geological materials (water and rock) and accurate determination of Li isotopic composition was set up. The separation of Li from water and rock samples was implemented by a single column containing 1.5 mL of Bio-Rad AG 50W-X12 (200–400 mesh) resin, with 0.40 M HCl and 1.0 M HCl as eluents. Only 8.5 and 14 mL of eluents were used to separate Li from water and rock samples with this method, respectively. Blank signal of the operation procedure was (2.4 ± 0.1) mV, which was almost same as the 2.3 mV of the 2% HNO3 signal used in this study. Experimental results showed that Li isotopic fractionation during leaching process was significant and deviation of δ7Li values in these samples with incompletely recovered Li reached up to 50‰. Lithium isotopic ratios were determined by multi-collector ICP-MS (Nu Plasma II) using the sample standard bracketing (SSB) method. L-SVEC standard with similar Li concentration to samples (about 80 ng mL?1) was used in this study. The external precision (2σ) of this technique, determined by repeated measurement of pure Li standard solutions and seawater was < ±0.8‰. The measured δ7Li values of seawater and rock standards AGV-2, BCR-2 and GSP-2 were +31.4‰ ± 0.7‰ (n = 18), +7.23‰ ± 0.16‰ (n = 4), +3.7‰ ± 0.7‰ (n = 8) and ?0.10‰ ± 0.18‰ (n = 4), respectively, similar to previously published values. This method could be used to accurately determine Li isotopic composition of various types of geological samples such as waters and rocks. The advantage of this method was that the amount of resin and reagent was reduced to 50% or less of the previous studies, thereby significantly improving the work efficiency and reducing the operation procedure blank.  相似文献   

10.
多接收器电感耦合等离子质谱精确测定钕同位素组成   总被引:6,自引:0,他引:6  
报道了本实验室近两年来Neptune MC-ICP-MS测试Nd同位素的结果。测试结果显示样品化学分离中伴随的大量铈对钕同位素组成测定没有影响;而分离后残余少量钐,在一定范围内(钐/钕<0.04)可以直接扣除,获得准确的Nd同位素组成。Neptune MC-ICP-MS和热电离质谱(TIMS)平行测定实际地质样品表明,Neptune MC-ICP-MS可以精确测定Nd同位素组成,与经典的TIMS技术相比,MC-ICP-MS可以获得与TIMS相媲美的数据精度,而且分析时间缩短,效率明显提高。  相似文献   

11.
A novel analytical technique for isotopic analysis of dissolved and particulate iron (Fe) from various marine environments is presented in this paper. It combines coprecipitation of dissolved Fe (DFe) samples with Mg(OH)2, and acid digestion of particulate Fe (PFe) samples with double pass chromatographic separation. Isotopic data were obtained using a Nu Plasma MC-ICP-MS in dry plasma mode, applying a combination of standard-sample bracketing and external normalization by Cu doping. Argon interferences were determined prior to each analysis and automatically subtracted during analysis. Sample size can be varied between 200 and 600 ng of Fe per measurement and total procedural blanks are better than 10 ng of Fe. Typical external precision of replicate analyses (1S.D.) is ±0.07‰ on δ56Fe and ±0.09‰ on δ57Fe while typical internal precision of a measurement (1S.E.) is ±0.03‰ on δ56Fe and ±0.04‰ on δ57Fe. Accuracy and precision were assured by the analysis of reference material IRMM-014, an in-house pure Fe standard, an in-house rock standard, as well as by inter-laboratory comparison using a hematite standard from ETH (Zürich). The lowest amount of Fe (200 ng) at which a reliable isotopic measurement could still be performed corresponds to a DFe or PFe concentration of ∼2 nmol L−1 for a 2 L sample size. To show the versatility of the method, results are presented from contrasting environments characterized by a wide range of Fe concentrations as well as varying salt content: the Scheldt estuary, the North Sea, and Antarctic pack ice. The range of DFe and PFe concentrations encountered in this investigation falls between 2 and 2000 nmol L−1 Fe. The distinct isotopic compositions detected in these environments cover the whole range reported in previous studies of natural Fe isotopic fractionation in the marine environment, i.e. δ56Fe varies between −3.5‰ and +1.5‰. The largest fractionations were observed in environments characterized by redox changes and/or strong Fe cycling. This demonstrates the potential use of Fe isotopes as a tool to trace marine biogeochemical processes involving Fe.  相似文献   

12.
Despite the large number of successful applications of laser ablation, elemental and isotopic fractionation coupled to inductively coupled plasma mass spectrometry (ICP-MS) remain as the main limitations for many applications of this technique in the fields of analytical chemistry and Earth Sciences. A substantial effort has been made to control such fractionations, which are well-established features of nanosecond laser ablation systems. Technological advancements made over the past decade now allow the ablation of solids by femtosecond laser pulses in the deep ultraviolet (UV) region at wavelengths less than 200 nm. Here the use of femtosecond laser ablation and its effects on elemental and isotopic fractionation is investigated. The Pb/U system is used to illustrate elemental fractionation and stable Fe isotopes are used to illustrate isotopic fractionation. No elemental fractionation is observed beyond the precision of the multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements. Without a matrix match between standard and sample, elemental fractionation is absent even when using different laser ablation protocols for standardization and samples (spot versus raster). Furthermore, we found that laser ablation-induced isotope ratio drifts, commonly observed during nanosecond laser ablation, are undetectable during ultraviolet femtosecond laser ablation. So far the precision obtained for Fe isotope ratio determinations is 0.1‰ (2 standard deviation) for the 56Fe/54Fe ratio. This is close to that obtainable by solution multiple-collector inductively coupled plasma mass spectrometry. The accuracy of the results appears to be independent of the matrix used for standardization. The resulting smaller particle sizes reduce fractionation processes. Femtosecond laser ablation carries the potential to solve some of the difficulties encountered during the two prior decades since the introduction of laser ablation.  相似文献   

13.
Li was extracted completely from the Geological Survey of Japan (GSJ) rock reference samples by HF-HC1 decomposition and separated from other alkali metal ions by cation exchange chromatography. The degree of Li isotope fractionation during the preparations of samples for mass spectrometry for Li isotopic ratio measurements was, therefore, negligible. The isotopic compositions of Li extracted from the GSJ samples were measured by double-filament surface ionization mass spectrometry. The permil (%.) deviation, δ7Li, of the 7Li-to-6Li ratio of one of the GSJ samples (JR-1) from that of the Li isotope standard, IRM-016, was +3.9%., with a 95% confidence limit of 0.7%. The δ7Li values of the 16 GSJ samples varied in the range −2.5 to +6.4%.. These data are probably the first such data obtained for the GSJ rock samples. No clear dependence of the δ7Li value on the kind of rock was observed.  相似文献   

14.
A high-performance liquid chromatography (HPLC) method using a column of 2-(1-pyrenyl) ethyldimethylsilylated silica was developed in this work in order to achieve satisfactory and reproducible fractionation of polychlorinated biphenyls (PCBs) from brominated flame retardants (BFRs) (polybrominated diphenylethers, PBDEs; and polybrominated biphenyls, PBBs). After the study of different chromatographic parameters (mobile phase composition and separation temperature were the most important) an isocratic elution with isooctane:toluene (98:2, v/v) at a flow-rate of 1 mL/min, a temperature of 45 °C, and UV-detection at 225 nm was selected for fractionation of PCBs (time region, 4.0-5.8 min) from PBDEs (5.8-9.0 min) and from PBBs (5.8-11.0 min). The applicability of this method to food samples was demonstrated by fractionating PCBs from PBDEs in three food samples (cheese, milk, and fish). Interferences from PCBs (present in real samples at much higher concentrations than PBDEs) were removed in this way. In addition, by analysing these samples by gas chromatography-mass spectrometry (GC-MS) with and without previous fractionation we were able to observe an improvement in detection sensitivity for PBDEs after HPLC fractionation.  相似文献   

15.
High‐precision on‐line procedure for measurement of calcium isotopic ratio by coupling ion chromatography to multicollector inductively coupled plasma mass spectrometry was developed. Calcium separation from the sample matrix was achieved on an ion chromatography column—IonPac CS16—ID 3 mm connected with CERS 500 2 mm suppressor and followed by multicollector inductively coupled plasma mass spectrometry calcium isotopic ratio determination. Dry plasma mode was used with Aridus II desolvation system. To sustained samples with high level of total dissolved salts as well as account capacity of applied analytical column, the method has been optimized regarding calcium isotope ratio measurements with low‐resolution mass spectrometry. Mass discrimination and instrument drift were corrected by sample‐standard bracketing method using the 44Ca/42Ca isotope ratio of SRM 915a as a standard. Good accuracy and reasonable precision of calcium isotope ratio (generally 0.20‰ [2SD]) were achieved, which are comparable to off‐line Ca separation and continuous measurement. The reproducibility of the proposed analytical procedure was verified by measuring the SRM 915a standard as a sample randomly over 3 months (n = 56). Applicability of the protocol was demonstrated for matrix‐rich natural water samples, coral samples, and bone standard reference materials.  相似文献   

16.
In the last years, the development of new methods for analyzing accurate and precise individual metalloproteins is of increasing importance, since numerous metalloproteins are excellent biomarkers of oxidative stress and diseases. In that way, methods based on the use of post column isotopic dilution analysis (IDA) or enriched protein standards are required to obtain a sufficient degree of accuracy, precision and high limits of detection. This paper reports the identification and absolute quantification of Cu,Zn-superoxide dismutase (Cu,Zn-SOD) in cytosol and mitochondria from mice hepatic cells using a innovative column switching analytical approach. The method consisted of orthogonal chromatographic systems coupled to inductively coupling plasma-mass spectrometry equipped with a octopole reaction systems (ICP-ORS-MS) and UV detectors: size exclusion fractionation (SEC) of the cytosolic and mitochondrial extracts followed by online anion exchange chromatographic (AEC) separation of Cu/Zn containing species. After purification, Cu,Zn-SOD was identified after tryptic digestion by molecular mass spectrometry (MS). The MS/MS spectrum of a doubly charged peptide was used to obtain the sequence of the protein using the MASCOT searching engine. This optimized methodology reduces the time of analysis and avoids the use of sample preconcentration and clean-up procedures, such as cut-off centrifuged filters, solid phase extraction (SPE), precipitation procedures, off-line fractions insolates, etc. In this sense, the method is robust, reliable and fast with typical chromatographic run time less than 20 min. Precision in terms of relative standard deviation (n = 5) is of 3–5% and detection limits is 0.21 ng Cu g−1.  相似文献   

17.
An improved technique for precise and accurate determination of boron isotopic composition in Na-rich natural waters (groundwater, seawater) and marine biogenic carbonates was developed. This study used a ‘micro-sublimation’ technique to separate B from natural sample matrices in place of the conventional ion-exchange extraction. By adjusting analyte to appropriate pH, quantitative recovery of boron can be achieved (>98%) and the B procedural blank is limited to <8 pg. An additional mass bias effect in MC-ICP-MS was observed which could not be improved via the standard-sample-standard bracketing or the ‘pseudo internal’ normalization by Li. Therefore a standard other than NBS SRM 951 was used to monitor plasma condition in order to maintain analytical accuracy. An isotope cross-calibration with results from TIMS shows that the space-charge mass bias on MC-ICP-MS can be successfully corrected using off-line mathematical manipulation. Several reference materials, including the seawater IAPSO and two groundwater standards IAEA-B-2 and IAEA-B-3, were used to validate this approach. We found that the δ11B of the reference coral JCp-1 was 24.22 ± 0.28‰, corresponding to seawater pH based on the coral δ11B-pH function.  相似文献   

18.
Here, a two‐stage column separation scheme is developed for the concomitant isolation of Sr, Pb, Nd, and Hf from geological samples. The first column, which consists of three resin layers (AG50W‐X8 ion exchange resin + Ln specific resin + Sr specific resin), separates the high field strength element + rare earth element, Sr and Pb from the matrices. Subsequently, Nd and Hf are further separated from the high field strength element + rare earth element fraction on the second column using 1 mL of Ln specific resin. The two‐stage column process can be completed within about seven and a half hours for a batch of samples (20–30). The separated Sr fraction was ready for isotope ratio measurements by thermal ionization mass spectrometry. The Pb, Nd, and Hf fractions were converted to nitrate prior to isotopic analyses by multi‐collector inductively coupled plasma mass spectrometry. The feasibility of this new procedure is confirmed by the analyses of four international rock standards (BCR‐2, AGV‐2, BHVO‐2, and JB‐3), which yielded isotope ratios that were in good agreement with other published data.  相似文献   

19.
The isotopic composition of lithium in an NIST SRM 924 Li2CO3, isotopically enriched supplied by ORNL and in seawater has been determined by using thermal ionization mass spectrometry (TIMS) based on the use of lithium phosphate as the ion source. In order to minimize isotopic fractionation, the ion ratio was measured by using a triple filament technique. The method produces a stable, high intensity Li+ ion beam that allows measurement of ng quantities of lithium for several hours. Lithium was separated from sample matrix and further converted to LiOH by employing a two-column ion exchange process. The mass ratio of LiOH to phosphoric acid was nearly stoichiometric in relation to Li3PO4. Lithium isotopes in a reference material supplied by NIST (L-SVEC Li2CO3) was measured to check the reproducibility of the method. A comparison was made between two TIMS units equipped with different types of detectors (a Faraday cup and a secondary electron multiplier). This highly sensitive technique can be applied to determine isotopic composition of Li in enriched isotopes as well as in the examination of low concentration Li reservoirs.  相似文献   

20.
Tin isotopes were fractionated by the liquid-liquid extraction technique with a crown ether, dicyclohexano-18-crown-6. The isotopic ratios of mSn/120Sn (m: 116, 117, 118, 119, 122 and 124) were measured by multi-collector inductively coupled plasma spectrometry (MC-ICP-MS) on a Nu Plasma 500 with a precision better than 0.05 permil amu−1 on each isotopic ratio. Odd atomic mass isotopes (117Sn and 119Sn) showed depletions compared to the even atomic mass isotopes (116Sn, 118Sn, 122Sn and 124Sn). We show that this odd-even staggering property originates from the nuclear field shift effect. The contribution of the nuclear field shift effect to the observed isotope enrichment factor was estimated to be ∼35%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号