首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The design, construction and optimization studies of a continuous flow hydride generation laser-induced breakdown spectroscopic system, HG-LIBS, for the determination of tin in aqueous environments is presented. Optimization of the Laser Induced Breakdown Spectroscopy (LIBS) signal with respect to carrier gas flow rate, analyte, acid (HCl) and reductant (NaBH4) concentrations and flow rates was performed by using spectral emission intensity from the neutral Sn(I) line at 284.0 nm under atmospheric pressures. With flow rates of 5.0 mL/min for NaBH4 and 2.5 mL/min for HCl, optimum NaBH4 and HCl concentrations were determined as 2.0% (w/v) and 1.0% (v/v), respectively. The hydride generation efficiency of the system was tested for tin hydride, stannane (SnH4), by inductively coupled plasma mass spectrometer (ICP-MS). It was found that higher than 99% of the analyte was released into the gaseous phase. Upon optimization, the minimum detectable Sn concentration was found as 0.3 mg/L in water samples. That corresponds to more than two orders of increase in sensitivity compared to methods that employ common sample introduction techniques in liquids analysis by LIBS. Over 90% recoveries were obtained from spiking experiments with river, tap and drinking water samples. Results illustrate potential use of the continuous flow HG-LIBS system for monitoring of Sn concentrations in aqueous environments.  相似文献   

2.
The gas-phase chemiluminescence detection system based on the ozonization of gaseous hydride was exploited and utilized for the determination of total tin in environmental samples. After sample treatment, tin was reduced to stannane by sodium borohydride in a phosphate buffer medium of pH 5.8. Flow injection technique was used to control the reaction precisely and reproducibly. The generated stannane, carried by helium, was separated from liquid and dried using an ice-salt cryogenic bath and subsequently trapped in a glass U-tube immersed in liquid nitrogen. The cryotrapped stannane was vaporized by bringing the tube to room temperature and subsequently carried in a flow of helium to a reaction chamber where ozone was used to oxidize the stannane. Chemiluminescence was produced during the oxidation process, which was utilized for the measurement of tin. Under optimal conditions, a detection limit of 0.32 μg L−1 was achieved with a relative standard deviation of 3.1% (10.0 μg L−1 Sn, n = 11). Interferences from transition metal ions and other hydride forming elements were reduced by the addition of 1,10-phenanthroline and through optimized hydride generation conditions. The proposed system was applied to the determination of Sn in water and soil samples with satisfactory results.  相似文献   

3.
The multivariate optimization of a mixed-gas plasma was conducted in an attempt to find conditions minimizing matrix effects without sacrificing the detection limits that are observed with an all argon plasma optimized for maximum sensitivity in inductively coupled plasma mass spectrometry. Compared to the latter, where 49.1 ± 7.1% (n = 17) analyte signal suppression resulted in the presence of 0.1 M Na, 3.8 ± 3.2% suppression (and 2.8 ± 2.1% enhancement in some cases) was observed in the optimized mixed-gas plasma with 0.13% v/v N2 in the plasma gas and 0.11% in the central channel as a sheath gas around the nebulizer gas flow. Furthermore, improved detection limits were observed for Al, Co, Pd, and V with the optimized mixed-gas plasma compared to an argon plasma at maximum sensitivity. The robustness of this mixed-gas plasma was further demonstrated through the accurate determination of U and Mo in NASS-5 seawater certified reference material using a simple external calibration, without matrix-matching or internal standardization. Indeed, the result obtained for Mo (9.1 ± 1.9 μg/L) was within the 95% confidence interval of the certified value of 9.6 ± 1.0 μg/L, while that obtained for U (3.0 ± 0.2 μg/L) was close to the information value of 2.6 μg/L. Spatial profiling results suggest better energy transfer between the toroidal zone and the central channel in the mixed-gas plasma.  相似文献   

4.
The feasibility of partial least squares (PLS) regression modeling of X-ray fluorescence (XRF) spectra of estuarine sediments has been evaluated as a tool for rapid trace element content monitoring. Multivariate PLS calibration models were developed to predict the concentration of Al, As, Cd, Co, Cr, Cu, Fe, Mg, Mn, Ni, Pb, Sn, V and Zn in sediments collected from different locations across the estuary of the Nerbioi-Ibaizabal River (Metropolitan Bilbao, Bay of Biscay, Basque Country). The study was carried out on a set of 116 sediment samples, previously lyophilized and sieved with a particle size lower than 63 μm. Sample reference data were obtained by inductively coupled plasma mass spectrometry. 34 samples were selected for building PLS models through a hierarchical cluster analysis. The remaining 82 samples were used as a test set to validate the models. Results obtained in the present study involved relative root mean square errors of prediction varying from 21%, for the determination of Pb at hundreds μg g−1 level, up to 87%, for Ni determination at little tens μg g−1 level. An average prediction error of ±37% for the 14 elements under study was obtained, being in all cases mean differences between predicted and reference results of the same order than the standard deviation of three replicates from a same sample. Residual predictive deviation values obtained ranged from 1.1 to 3.9.  相似文献   

5.
A method for the direct determination (without sample pre-digestion) of microelements in fruit juice by inductively coupled plasma optical emission spectrometry has been developed. The method has been optimized by a 23 factorial design, which evaluated the plasma conditions (nebulization gas flow rate, applied power, and sample flow rate). A 1:1 diluted juice sample with 2% HNO3 (Tetra Packed, peach flavor) and spiked with 0.5 mg L− 1 of Al, Ba, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Sb, Sn, and Zn was employed in the optimization. The results of the factorial design were evaluated by exploratory analysis (Hierarchical Cluster Analysis, HCA, and Principal Component Analysis, PCA) to determine the optimum analytical conditions for all elements. Central point condition differentiation (0.75 L min− 1, 1.3 kW, and 1.25 mL min− 1) was observed for both methods, Principal Component Analysis and Hierarchical Cluster Analysis, with higher analytical signal values, suggesting that these are the optimal analytical conditions. F and t-student tests were used to compare the slopes of the calibration curves for aqueous and matrix-matched standards. No significant differences were observed at 95% confidence level. The correlation coefficient was higher than 0.99 for all the elements evaluated. The limits of quantification were: Al 253, Cu 3.6, Fe 84, Mn 0.4, Zn 71, Ni 67, Cd 69, Pb 129, Sn 206, Cr 79, Co 24, and Ba 2.1 µg L− 1. The spiking experiments with fruit juice samples resulted in recoveries between 80 and 120%, except for Co and Sn. Al, Cd, Pb, Sn and Cr could not be quantified in any of the samples investigated. The method was applied to the determination of several elements in fruit juice samples commercialized in Brazil.  相似文献   

6.
Monobutyltin (MBT), dibutyltin (DBT) and tributyltin (TBT) were determined in natural water samples by aqueous phase ethylation with sodium tetraethylborate (STEB), room temperature trapping of the resulting volatile derivatives on Tenax TA®, followed by gas chromatography-quartz furnace atomic absorption spectrometry (GC-QFAAS). Recoveries of butyltin spikes from natural water samples were 90-109% at concentrations of ∼100 ng Sn/l. The method precision at ∼100 ng Sn/l was ≤6% RSD for butyltins spiked into natural waters. The detection limits for 1 l water samples were <1 ng Sn/l for all butyltin species. Sample throughput of the method is high (greater than three samples per hour) due to the two-stage nature of the procedure, which allows derivatisation/trapping and GC-QFAAS quantitation to be performed separately. Off-line trapping is also advantageous as it extends the life of the GC column and quartz furnace to at least 12 months due to minimisation of carry-over of co-purged material.  相似文献   

7.
The optimization and application of gas chromatograph coupled with inductively coupled plasma mass spectrometer (GC-ICPMS) (equipped with a commercially available interface) for the speciation of butyltin compounds in freshwater origin sediment and mussel samples is described. Optimization focused on the system parameters that have the greatest effect on signal intensity such as plasma power, ion lenses and make up gas flow (in the interface). Xenon (Xe) containing argon gas (Ar) was applied as tuning gas providing continuous Xe signal for the optimization of system parameters. It was found that plasma power and make up gas are interrelated variables and provide a set of paired optimum values at each power settings. The absolute optimum values obtained at 800 W plasma power and 1.2 L min−1 make up gas flow rate when 7 mm sample depth was adjusted. The optimum settings obtained were then checked by means of a test solution (tetraethyltin dissolved in hexane). Same optimum conditions were found when tin (Sn) transient signals were monitored. Detection limits were calculated for the three species using the optimized system parameters. Detection limits are the following: for monobutyltin (MBT) 5.6 ng Sn kg−1, for dibutyltin (DBT) 6.6 ng Sn kg−1 and for tributyltin (TBT) 3.4 ng Sn kg−1 obtained. Determination of the butyltin compounds were carried out by means of species-specific isotope dilution analysis. The spike solution contained all species investigated but with altered isotopic composition. Each species were enriched in their 119Sn isotope. Concentrations found in Hungarian freshwater origin mussel and sediment samples ranged between 19 and 39 ng g−1for MBT, between 1.2 and 6.3 ng g−1 for DBT and between 1.2 and 3.2 ng g−1 for TBT indicated as Sn in dry weight. Validation of the method was done by means of certified reference materials (BCR CRM 646 and 477). Good agreement was found between certified and experimental values. Normalized deviation (En) was also computed in order to validate the method used. En values obtained ranged between 0.07 and 0.11 for mussel samples and between 0.26 and 0.72 for sediment samples. These values show that isotope dilution-GC-ICPMS methodology is valid for the determination of MBT, DBT and TBT from both types of matrices.  相似文献   

8.
Elevated levels of heavy metals in soil may allow uptake of these toxic species in food plants. Barber Orchard, Haywood County, NC has been designated a U.S. EPA Superfund site, primarily because of elevated levels of lead and arsenic. In this work, carrots, lettuce, and tomatoes were cultivated in a greenhouse in control soil and soil obtained from Barber Orchard. The resulting samples were then analyzed for lead and arsenic using inductively coupled plasma optical emission spectrometry (ICP-OES). Except for carrot roots grown in the contaminated soil, the concentrations of lead and arsenic in the plants were below the ICP-OES detection limit. The concentration of lead in carrot roots was 20 ± 11 μg/g, which represents a bioconcentration factor (BCF) of 0.03.  相似文献   

9.
A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of toxic element concentrations (arsenic, barium, cobalt, copper, lead, nickel, strontium, vanadium and zinc) in ash samples was developed. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg(II) 280.270 nm/Mg(I) 285.213 nm line intensity ratios. The highest line intensity ratios were observed when a nebulizer gas flow of 0.6 L min−1, auxiliary gas flow of 0.2 L min−1 and plasma power of 1400 W were used for radially viewed plasma. The analysis of SRM 1633b showed that the ultrasound-assisted method developed is highly comparable with the microwave digestion method standardized by the United States Environmental Protection Agency (EPA-3052). The ultrasound-assisted digestion with a digestion solution of aqua regia and hydrofluoric acid (HF) resulted in recovery rates of over 81%. One exception is arsenic which resulted in recoveries of about 60% only; however, it could be digested with good recovery (>90%) using a digestion solution of 5 mL of water and 5 mL of aqua regia. The major advantage of the ultrasound-assisted digestion over microwave digestion is the high treatment rate (30 samples simultaneously with a sonication time of 18 min).  相似文献   

10.
A low-flow air-cooled inductively coupled plasma (ICP) design for optical emission spectrometry (OES) with axial plasma viewing is described and an evaluation of its analytical capabilities in trace element determinations is presented. Main advantage is a total argon consumption of 0.6 L min−1 in contrast to 15 L min−1 using conventional ICP sources.The torch was evaluated in trace element determinations and studied in direct comparison with a conventional torch under the same conditions with the same OES system, ultrasonic nebulization (USN) and single-element optimization. A variety of parameters (x-y-position of the torch, rf power, external air cooling, gas flow rates and USN operation parameters) was optimized to achieve limits of detection (LOD) which are competitive to those of a conventional plasma source.Ionic to atomic line intensity ratios for magnesium were studied at different radio frequency (rf) power conditions and different sample carrier gas flows to characterize the robustness of the excitation source. A linear dynamic range of three to five orders of magnitude was determined under compromise conditions in multi-element mode. The accuracy of the system was investigated by the determination of Co, Cr, Mn, Zn in two certified reference materials (CRM): CRM 075c (Copper with added impurities), and CRM 281 (Trace elements in rye grass). With standard addition values of 2.44 ± 0.04 and 3.19 ± 0.21 μg g−1 for Co and Mn in the CRM 075c and 2.32 ± 0.09, 81.8 ± 0.4, 32.2 ± 3.9 for Cr, Mn and Zn, respectively, were determined in the samples and found to be in good agreement with the reported values; recovery rates in the 98-108% range were obtained. No influence on the analysis by the matrix load in the sample was observed.  相似文献   

11.
A rabbit antibody immunoaffinity (IA) column procedure was evaluated as a cleanup method for the determination of atrazine in soil, sediment, and food. Four IA columns were prepared by immobilizing a polyclonal rabbit anti-atrazine antibody solution to HiTrap Sepharose columns. Atrazine was bound to the IA columns when the loading solvents were either 100% water, 2% acetonitrile in water, or 10% methanol in phosphate buffered saline (PBS). Quantitative removal of atrazine from the IA columns was achieved with elution solvents of either 70% ethanol in water, 70% methanol in water, or 100% methanol. One control column was prepared using nonspecific rabbit IgG antibody. This control column did not retain any applied atrazine indicating atrazine did not bind indiscriminately to protein or the Sepharose support. The four IA columns showed reproducible coupling efficiency for the immobilization of the atrazine antibody and consistent binding and releasing of atrazine. The coupling efficiency (4.25 mg of antibody in 1 mL of resin bed) for the four IA columns ranged from 93 to 97% with an average of 96 ± 2% (2.1%). Recoveries of the 500, 50, and 5 ng mL−1 atrazine standard solutions from the four IA columns were 107 ± 7% (6.5%), 122 ± 14% (12%), and 114 ± 9% (8.0%) respectively, based on enzyme-linked immunosorbent assay (ELISA) data. The maximum loading was approximately 700 ng of atrazine for each IA column (∼0.16 μg of atrazine per mg of antibody). The IA columns could withstand 100% methanol as the elution solvent and could be reused more than 50 times with no change in performance. The IA columns were challenged with soil, sediment, and duplicate-diet food samples and effectively removed interferences from these various matrices for subsequent gas chromatography/mass spectrometry (GC/MS) or ELISA analysis. The log-transformed ELISA and GC/MS data were significantly correlated for soil, sediment and food samples although the ELISA values were slightly higher than those obtained by GC/MS. The IA column cleanup procedure coupled with ELISA analysis could be used as an alternative effective analytical method for the determination of atrazine in complex sample media such as soil, sediment, and food samples.  相似文献   

12.
The feasibility of using diluted HNO3 solutions under oxygen pressure for decomposition of whole and non-fat milk powders and whey powder samples has been evaluated. Digestion efficiency was evaluated by determining the carbon content in solution (digests) and the determination of Ca, Cd, Cu, Fe, K, Mg, Mn, Mo, Na, Pb and Zn was performed by inductively coupled plasma optical emission spectrometry and Hg by chemical vapor generation coupled to inductively coupled plasma mass spectrometry. Samples (up to 500 mg) were digested using HNO3 solutions (1 to 14 mol L− 1) and the effect of oxygen pressure was evaluated between 2.5 and 20 bar. It was possible to perform the digestion of 500 mg of milk powder using 2 mol L− 1 HNO3 with oxygen pressure ranging from 7.5 to 20 bar with resultant carbon content in digests lower than 1700 mg L− 1. Using optimized conditions, less than 0.86 mL of concentrated nitric acid (14 mol L− 1) was enough to digest 500 mg of sample. The accuracy was evaluated by determination of metal concentrations in certified reference materials, which presented an agreement better than 95% (Student's t test, P < 0.05) for all the analytes.  相似文献   

13.
A new marine sediment reference material (NMIJ CRM 7301-a) for butyltins analysis was prepared and certified by the National Metrological Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). The original material of the sediment was collected at a bay near industrial activities in Japan. The sediment material was air-dried, sieved, homogenized, and packaged into 1,000 glass bottles (60 g each). Certification of NMIJ CRM 7301-a was carried out at NMIJ using two different types of species-specific isotope dilution mass spectrometry: isotope dilution–ethylation–gas chromatography/inductively coupled plasma mass spectrometry (GC/ICPMS) and isotope dilution–ethylation–gas chromatography/mass spectrometry (GC/MS). A mixture of 118Sn-enriched monobutyltin, dibutyltin, and tributyltin was synthesized in our laboratory and was used as a spike for both techniques. Certified values are given for tributyltin (0.044±0.004 mg kg–1 as Sn), dibutyltin (0.056±0.006 mg kg–1 as Sn, and monobutyltin (0.058±0.013 mg kg–1 as Sn), being at lower levels than currently available sediment CRMs for the analysis of organotins.  相似文献   

14.
An analytical procedure for direct introduction of biodiesel samples into an inductively coupled plasma mass spectrometer (ICP-MS) by using microemulsion for sample preparation was developed here. Cadmium, Co, Cu, Mn, Ni, Pb, Ti, and Zn were determined in biodiesel microemulsified samples prepared from different oleaginous sources (African palm, castor beans, palm, soybeans and an unknown oleaginous). Microemulsions were prepared using 0.25 mL Triton X-100, 0.25 mL 20% v v− 1 HNO3, 0.50 mL biodiesel sample and 4.0 mL n-propanol. Argon-oxygen mixture was added to the plasma as auxiliary gas for correcting matrix effects caused by the high carbon load due to biodiesel microemulsions. The oxygen gas flow rate was set in 37.5 mL min− 1. The accuracy of the developed procedure was evaluated by applying addition-recovery experiments for biodiesel samples from different sources. Recoveries varied from 76.5 to 116.2% for all analytes but Zn in castor beans biodiesel sample (65.0 to 76.2%). Recoveries lower than 86.6% were obtained for palm biodiesel sample, probably due to matrix effects. Detection limits calculated by using oxygen in the composition of the auxiliary gas added to the plasma were higher than those calculated without using it, probably due to the highest formation of oxides. Despite oxides formation, best analytical performance was reached by using oxygen as auxiliary gas and by proper correction of transport interferences. The developed procedure based on microemulsion formation was suitable for direct introduction of biodiesel samples in ICP-MS.  相似文献   

15.
Copper is an essential trace metal that shows a vertical recycled-scavenged profile in the ocean. To help elucidate the biogeochemical cycling of Cu in the present and past oceans, it is important to determine the distribution of Cu isotopes in seawater. However, precise isotopic analysis of Cu has been impaired by the low concentrations of Cu as well as co-existing elements that interfere with measurements by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The objective of this study is to develop a simple Cu pre-concentration method using Nobias-chelate PA1 resin (Hitachi High Technologies). This extraction followed by anion exchange, allows precise analysis of the Cu isotopic composition in seawater. Using this method, Cu was quantitatively concentrated from seawater and >99.9999% of the alkali and alkaline earth metals were removed. The technique has a low procedural blank of 0.70 ng for Cu for a 2 L sample and the precision of the Cu isotopic analysis was ±0.07‰ (±2SD, n = 6). We applied this method to seawater reference materials (i.e., CASS-5 and NASS-6) and seawater samples obtained from the northwestern Pacific Ocean. The range of dissolved δ65Cu was 0.40–0.68‰.  相似文献   

16.
Alexander Okorie 《Talanta》2010,82(4):1421-2661
The optimization of a microwave dissolution procedure for potentially toxic elements in a contaminated soil sample has been evaluated using a central composite design approach. By considering the operating parameters of temperature, digestion time, microwave power and acid volume it was possible to identify the following optimum conditions: temperature, 160 °C; power, 750 W; digestion time, 25 min; and, an aqua regia volume of 13 mL. These microwave digestion conditions were then applied to 19 samples obtained from a former industrial site in Newcastle upon Tyne. Of the range of potentially toxic elements present at the site as a consequence of former industrial activity (As, Cd, Cr, Cu, Mo, Ni, Pb and Zn), the majority of topsoil samples indicated elevated concentrations of one or more of these elements. In particular, data obtained using either inductively coupled plasma mass spectrometry or flame atomic absorption spectroscopy indicates the high and wide concentration of Pb on the site (188-60300 mg/kg). Comparing the resulting potentially toxic elements data with UK soil guidelines values (SGVs) suggests at least parts of the site represent areas of potential human health risk. It was found that lead soil values exceeded the SGV on 17 out of the 19 sampling sites; similarly for As 6 out of 19 sampling sites exceeded the SGV. While for Cd, Cr and Ni the soil levels were below the stated SGVs.  相似文献   

17.
The role played by acidity (0.01–5 mol L− 1 HNO3) and l-cysteine (0.1–0.2 mol L− 1) in the formation of stannane by reaction of Sn(IV) solution with aqueous tetrahydroborate(III) (0.05–0.2 mol L− 1), has been investigated by continuous flow hydride generation coupled with atomic absorption spectrometry using a miniature argon–hydrogen diffusion flame as the atomizer. Different mixing sequences and reaction times of the reagents were useful in the identification of those processes which contribute to the generation of stannane in different reaction conditions, both in the absence and in the presence of l-cysteine. The lack of stannane generation at high acidities is due to the formation of Sn substrates and hydridoboron species which are unreactive. The capture of the stannane in solution, following its ionization to SnH3+ from already formed stannane, does not play any role. While the presence of l-cysteine, does not affect the generation efficiency at lower acidities, it expands the optimum range of acidities for stannane generation to higher values. This effect can be addressed to both the buffering capacity of l-cysteine and to the formation of Sn-(l-cysteine) complexes, while the formation of (l-cysteine)–borane complexes do not play a significant role. Formation of Sn-(l-cysteine) complexes also appears to be useful for stabilization of tin solution at low acidities values.  相似文献   

18.
Following a mini-review of crawfish aquaculture, the concentrations (mean in micrograms of analyte per gram of dried sample ± 95% confidence interval, range) determined by inductively coupled plasma-optical emission spectrometry of cadmium (0.49 ± 0.14, 0.34-0.79 ), copper (34.9 ± 5.3, 23.8-44.2), nickel (1.83 ± 0.54, 1.08-3.39), lead (18.0 ± 4.0, 9.9-23.), iron, and zinc (47.3 ± 4.6, 41.3-55.8) were relatively constant with a slight increase in iron (620.4 ± 205.8, 328.8-1072.8) in whole crawfish in a season of 4 months (February through May 2009) in Southwest Louisiana. The temperature of the crawfish ponds was monitored weekly but had no effect on the metal concentration in the crawfish trial. The copper and zinc concentrations in the crawfish pond soil decreased with increasing temperature. The other four metals showing no effect of temperature variations (increase). A comparison with a previous study showed no significant changes in the metal concentrations in the crawfish.  相似文献   

19.
A novel low-blank method is described for the analysis of bismuth in seawater based on preconcentration using an ethylenediaminetriacetic acid chelating resin column followed by determination with inductively coupled plasma sector-field mass spectrometry (ICPSFMS). A sample is siphoned into and drains through the column with the flow rate being kept constant by using a flotation device. Bi in 250 mL of acidified seawater is extracted onto the column in this process and eluted with 2 mL of 3 M HNO3 followed by 3 mL of ultra-high purity water. The concentration of Bi in the eluate is measured by ICPMS. The benefits of the method compared to others are its simplicity, a smaller amount of seawater, and lower procedural blanks and detection limits at pg kg−1 levels. Data on dissolved Bi in open ocean reference samples of SAFe and GEOTRACES programs are presented for the first time.  相似文献   

20.
A quadrupole inductively coupled plasma mass spectrometer (Q-ICP-MS) equipped with a dynamic reaction cell (DRC) and coupled with a desolvating nebulization system (APEX-IR) was employed to determine 17 elements (Al, As, Ba, Cd, Co, Cr, Li, Mn, Mo, Ni, Pb, Sb, Se, Sn, Sr, V, and Zr) in blood samples. Ammonia (for Al, Cr, Mn, and V) and O2 (for As and Se) were used as reacting gases. Selection of the best flow rate of the gases and optimization of the quadrupole dynamic bandpass tuning parameter (RPq) were carried out, using digested blood diluted 1 + 9 with deionized water and spiked with 1 μg L−1 of Al, Cr, Mn, V and 5 μg L−1 of As and Se. Detection limits were determined in digested blood using the 3σ criterion. The desolvating system allowed a sufficient sensitivity to be achieved to determine elements at levels of ng L−1 without detriment of signal stability. The accuracy of the method was tested with the whole blood certified reference material (CRM), certified for Al, As, Cd, Co, Cr, Mn, Mo, Ni, Pb, Sb, Se, and V, and with indicative values for Ba, Li, Sn, Sr, and Zr. The addition calibration approach was chosen for analysis. In order to confirm the DRC data, samples were also analyzed by means of sector field inductively coupled plasma mass spectrometry (SF-ICP-MS), operating in medium (mm = 4000) and high (mm = 10,000) resolution mode and achieving a good agreement between the two techniques.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号